Home

Broan 345SOWW Installation Guide

image

Contents

1. BROAN MODELS 345SOBK 345SOWW INSTALLATION Note This ventilator is capable of replacing an existing 120 volt powered aitic ventilator Only a qualified per son should remove any electrical wiring in accordance with local codes and standards wt 1 Determine the sun s best exposure location on your roof barring shade trees other buildings etc at 4 00pm in the hottest month of the year Generally we recommend a point located 24 36 on center below the roof peak and centrally along the ridgeline on the south southwest or west side of the home 2 Prior to installation we recommend setting up the ventilator to verify operation Take the ventilator to a location exposed to sun Removing the cardboard cover from the solar panel should cause the ventilator to operate Secure cardboard in place over solar panel for safety Page 2 3 Separate the dome from the base by removing four 4 sheet metal screws Set dome aside 4 Working from the inside of your attic find the desired ventilator location and mark a spot halfway between rafters at a point that is 24 36 below the roof ridge 5 Drill a guide hole through the roof at this mark BROAN MODELS 345SOBK 345SOWW Page 3 6 From the roof side using the guide hole as the center point use a nail and string to scribe a 16 1 2 diameter circle on the shingles Note If replacing an ex
2. Esta unidad tiene un impulsor sin protecci n No lo use en sitios f cilmente accesibles para personas o animales Este ventilador se acciona cuando el panel solar se expone a la luz del sol Para reducir el riesgo de lesiones mientras instala da servicio o limpia la unidad cubra el panel solar con cart n o desconecte los cables de las terminales del motor tome nota de las ubicaciones de los cables cuando los desconecte La entrada de aire abierta recomendada para este ventilador es de 2 pies cuadrados 0 19 metros cuadrados La mejor ubicaci n para estas ventilaciones de admisi n de aire es debajo de los aleros con acceso directo al tico De no suministrar estas entradas se podr a ocasionar que se invierta la corriente natural de los electrodom sticos de gas La instalaci n de su ventilador para tico crear una abertura con malla hacia el espacio de su tico Si hubiera una lluvia muy intensa podr a provocarse un ligero rociado de la lluvia en este espacio del tico Esta situaci n es normal con todos los ventiladores de tico y no provocar da os a la estructura Le recomendamos que no guarde art culos de valor directamente debajo de la abertura del ventilador en el techo Este ventilador est dise ado para instalarse en el techo Los ventiladores para montaje en hastial Broan Modelos 353 345GOBK y 345GOWW est n disponibles para aplicaciones en muros laterales El domo del ventilador y la base de pl stico se
3. curit notamment celles publi es par la National Fire Protection Association NFPA l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et les codes des autorit s locales Veillez ne pas endommager le c blage lectrique ou d autres quipements non apparents lors de la d coupe ou du per age du mur ou du plafond OUTILS ET MAT RIEL REQUIS QOOQOOUUUUUOO Perceuse Meche 1 4 po Scie sauteuse ou scie passe partout Marteau R gle ruban mesurer Crayon feutre ou stylet Couteau universel Barre clous pour enlever les clous toiture Douille 5 16 po et rallonge Enduit toiture Clous toiture galvanis s de 4 4 cm 1 po min ATTENTION il 10 11 12 Pour ventilation g n rale uniquement N utilisez pas cet appareil pour vacuer des mati res ou des vapeurs dangereuses ou explosives Pour viter d endommager les roulements de moteur de d s quilibrer les pales ou de les rendre bruyantes d barrassez l appareil de la poussi re de platre de construction etc Cet appareil comporte une h lice non prot g e Ne l utilisez pas dans un endroit facilement accessible aux personnes ou aux animaux Ce ventilateur se met en marche lorsque le panneau solaire est expos au soleil Pour r duire les risques de blessure lors de l installation de l entretien ou du nettoyage de l appareil couvrez le panneau solaire d un carton ou d branchez les fils
4. l tape 3 Retirez le carton du panneau solaire et v rifiez le fonctionnement du ventilateur 13 Assurez vous que la base du ventilateur est parall le la ligne du fa te soulevez d licatement les bardeaux et clouez ou vissez la base sur le toit l aide de clous toiture galvanis s ou de vis Clouez ou vissez le pourtour de la base tous les 15 cm 6 pouces BROAN MOD LES 345SOBK 345SOWW PIECES DE RECHANGE Les pi ces de rechange peuvent tre command es sur notre site Web Visitez notre site a www Broan com Modele Rep re 345SOBK a A N noir 77001311 CWT45 79310005 79080082 77001284 Mod le 345SOWW bois intemp ris 77001313 CWT45 79310005 79080082 77001287 Page 11 Description Ensemble de panneau solaire d me Thermostat optionnel H lice de ventilateur avec vis d arr t Moteur CC Panneau de base BROAN MOD LES 345SOBK 345SOWW Page 12 GARANTIE BROAN NUTONE LLC Garantie exclusive limit e Le contrat de garantie exclusive limit e la Garantie est conclu entre le client et Broan NuTone LLC Broan Le client a lu attentivement cette garantie et convient que l ex cution des obligations de Broan ci dessous lui fournira un recours ad quat qui servira aux fins essentielles de l accord des parties relativement aux produits fabriqu s par Broan et identifi s au verso de la pr sente les Produits Le client reco
5. 6 a os a partir de la fecha de entrega al Cliente de manera colectiva el Periodo de garant a libre de defectos en materiales y mano de obra siempre y cuando dichos Productos se usen para el prop sito para el que fueron dise ados y reciban el servicio adecuado de conformidad con el Manual del usuario que se entreg al Cliente Sujeto a lo anterior si en alg n momento durante el Periodo de garant a alg n Producto deje de apegarse a la garant a anterior por una raz n de defecto en materiales o mano de obra el Cliente deber notificar adecuadamente por escrito a Broan e incluir con dicho aviso un recibo de venta o un comprobante de compra del Producto defectuoso y Broan a su discreci n reparar o reemplazar el Producto o componente defectuoso sin cargo al Cliente excepto por A Costos incurridos en el transporte de los Productos o piezas componentes hacia y desde el distribuidor designado por Broan o su planta de manufactura en Hartford Wisconsin y B Cargos por mano de obra u otros costos incidentales al retiro o remontaje de piezas componentes reparadas o reemplazadas al amparo de esta Garant a ambos correr n a cargo del Cliente No obstante cualquier disposici n en la presente que se ale otra cosa esta Garant a no se ampliar para Broan ni la obligar a tomar medida alguna con respecto a A Productos que hayan sido modificados alterados instalados usados u operados de una manera que no sea recomendada por Broan
6. incluyendo cualesquiera Productos en los cuales se hayan instalado piezas no fabricadas ni aprobadas por Broan B Productos que no hayan recibido el servicio de manera regular o adecuada de acuerdo con el Manual del usuario o que de otra manera se hayan desatendido y C El uso y desgaste servicio y mantenimiento y elementos de reemplazo ordinarios ESTA GARANT A SE APLICA NICAMENTE A MAQUINARIA EQUIPO Y PIEZAS COMPONENTES FABRICADAS POR BROAN ESTA GARANT A NO SE APLICA NI EXTIENDE A A PIEZAS COMPRADAS POR SEPARADO DE DICHA MAQUINARIA Y EQUIPO CUBIERTAS POR UNA GARANT A ESCRITA POR SEPARADO O B ELEMENTOS DEL EQUIPO O ACCESORIOS FABRICADOS POR ENTIDADES AJENAS A BROAN EXCEPTO COMO SE DECLARE ESPEC FICAMENTE EN EL P RRAFO INMEDIATO ANTERIOR BROAN NO OTORGA GARANT A NI HACE UNA DECLARACI N EXPRESA O IMPL CITA QUE INCLUYA SIN LIMITACIONES ALGUNA GARANT A DE COMERCIALIZACI N O APTITUD PARA UN FIN EN PARTICULAR LA GARANT A ESTABLECIDA EN EL P RRAFO ANTERIOR Y LAS OBLIGACIONES Y RESPONSABILIDADES DE BROAN SEG N ESTE DOCUMENTO REPRESENTAN LOS NICOS Y EXCLUSIVOS REMEDIOS DEL CLIENTE Y EST N EXPRESAMENTE EN LUGAR DE CUALQUIERA Y TODOS LOS DEM S REMEDIOS GARANT AS O RESPONSABILIDADES EXPRESOS O IMPL CITOS Y DE TODOS LOS CUALES EL CLIENTE SE EXIME EXPRESAMENTE NO HAY GARANT AS QUE SE EXTIENDAN M S ALL DE LA DESCRIPCI N DEL TEXTO DE LA PRESENTE EN NING N CASO LA RESPONSABILIDAD DE BROAN AL AMPARO DE LA PRESENTE EXCED
7. ou ouest du toit 2 Avant l installation il est conseill d essayer le ventilateur pour v rifier son fonctionnement Placez le ventilateur un endroit expos au soleil Enlever le carton qui couvre le panneau solaire devrait faire d marrer le ventilateur Fixez le carton en place sur le panneau solaire pour des raisons de s curit Page 8 3 S parez le d me du ventilateur de sa base en enlevant les quatre 4 vis t le Mettez le d me de c t 4 De l int rieur du grenier trouvez l endroit voulu et marquez un point mi chemin entre deux chevrons environ 61 91 cm 24 36 po en dessous du fa te du toit 5 Percez un avant trou dans le toit au niveau du rep re BROAN MOD LES 345SOBK 345SOWW Page 9 6 De l ext rieur du toit et en utilisant l avant trou comme point central a l aide d un clou et d une corde tracez un cercle de 42 cm 16 1 2 po de diam tre sur les 9 Percez un grand trou de d part pour la scie sauteuse bardeaux Remarque Si vous remplacez un ancien juste l int rieur de la ligne du cercle de 35 6 cm 14 po ventilateur l ouverture peut tre plus grande que 42 cm trac l tape 8 16 1 2 po ce qui ne pose pas de probl me tant que le rev tement du toit chevauche le contour du ventilateur d au moins 5 cm 2 po sur tous les c t s A 10 Coupez le ou les panneaux du toit a l int rieur de la ligne 8 En utilis
8. pueden pintar con pintura de alta calidad Siga las recomendaciones del fabricante de pintura para el acr lico y el pl stico ABS seg n corresponda Tenga cuidado de evitar que le caiga pintura al panel solar Este ventilador incluye un motor lubricado permanentemente No lo lubrique ni lo desarme Las instrucciones de instalaci n contenidas en este documento son solamente recomendaciones y cada profesional en particular puede tener sus propios m todos de instalaci n Si el techo ya cuenta con una garant a la instalaci n de este producto realizada por otra persona diferente al instalador del techo puede poner en riesgo cualquier reclamo de garant a en el futuro Verifique con el instalador original del techo por si esto fuera motivo de preocupaci n Cuando trabaje con tejas de asfalto en clima fr o por debajo de 40 F 4 C tenga cuidado de no da ar los bordes y las esquinas de las tejas Para las instalaciones en climas donde la condensaci n fr o no es una preocupaci n Modelo Broan CWT45 termostato est disponible Se desconecta la electricidad al motor cuando la temperatura disminuye por debajo de 50 F 10 C Cuando la temperatura alcanza 61 F 16 C se aplica electricidad al motor Registre su producto en el sitio web www broan com register BROAN MODELOS 345SOBK 345SOWW INSTALACI N Nota Este ventilador tiene capacidad para reemplazar un ventilador para tico existente de 120 voltios S l
9. BROAN MODELS 345SOBK 345SOWW ROOF MOUNT SOLAR POWERED ATTIC VENTILATOR READ AND SAVE THESE INSTRUCTIONS WARNING A TO TO 4 REDUCETHE RISK OF FIRE ELECTRIC SHOCK OR INJURY PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty Before servicing or cleaning unit disable the ventilator by cover ing the solar panel with cardboard or disconnecting the wires from the motor terminals note wire locations when disconnect ing Installation work must be done by a qualified person s in ac cordance with all applicable codes and standards including fire rated construction codes and standards If removing an existing 120 VAC powered attic ventilator use only a qualified person s to remove any electrical wiring in accordance with all applicable codes and standards Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufac turer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Condition ing Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidde
10. CEDENT BROAN N OFFRE AUCUNE GARANTIE NI REPRESENTATION EXPRESSE OU IMPLICITE Y COMPRIS ENTRE AUTRES TOUTE GARANTIE DE VALEUR MARCHANDE OU D ADAPTATION A UN USAGE PARTICULIER LA GARANTIE STIPULEE DANS LE PARAGRAPHE PRECEDENT ET LES OBLIGATIONS ET RESPONSABILITES DE BROAN QUI EN DECOULENT REPRESENTENT LE SEUL ET UNIQUE RECOURS DU CLIENT ET REMPLACENT TOUT AUTRE RECOURS GARANTIE OU RESPONSABILITE EXPRESSE OU IMPLICITE AUXQUELS LE CLIENT RENONCE EXPRESSEMENT IL N Y A AUCUNE GARANTIE DEPASSANT LA DESCRIPTION QUI SUIT LA RESPONSABILITE DE BROAN NE SAURAIT EN AUCUN CAS D PASSER LA VALEUR DU PRIX D ACHAT DU PRODUIT DE PLUS BROAN DECLINE TOUTE RESPONSABILITE QUANT AUX DOMMAGES SPECIAUX INDIRECTS ACCESSOIRES OU CONSECUTIFS DE QUELQUE NATURE QUE CE SOIT Broan se r serve le droit de modifier alt rer ou am liorer tout produit ou quipement qu elle fabrique sans avoir le devoir ni l obligation de modifier alt rer am liorer ou remplacer aucun des produits couverts par la pr sente CETTE GARANTIE ENONCE L ENTENTE FINALE COMPLETE ET EXCLUSIVE ENTRE LES PARTIES AU SUJET DES PRODUITS AINSI QUE LES OBLIGATIONS DE BROAN EN MATIERE DE GARANTIE AUCUNE AFFIRMATION RELATIVE A DES FAITS NI PROMESSE DESCRIPTION DEMONSTRATION EXEMPLE OU MODELE NE CONSTITUE UNE GARANTIE NI AUTREMENT NE MODIFIE NE COUVRE OU N ALT RE CETTE GARANTIE A MOINS QUE CE SOIT DANS UN INSTRUMENT ECRIT SIGNE PAR UN RESPONSABLE AUTORISE PAR BROAN Cette garantie est s
11. ELOS 345SOBK 345SOWW P gina 18 GARANT A BROAN NUTONE LLC Garant a limitada exclusiva El Convenio de Garant a Limitada Exclusiva la Garant a se celebra entre el Cliente y Broan NuTone LLC Broan El Cliente ha revisado cuidadosamente esta Garant a y est de acuerdo en que el desempe o de las obligaciones de Broan al amparo de este documento brindar al Cliente un remedio adecuado que servir para el prop sito esencial del acuerdo de las partes relacionado con los productos fabricados por Broan e identificados al reverso de la presente los Productos El Cliente reconoce y acepta que est comprando los Productos para fines residenciales y no para fines industriales o comerciales despu s de una cuidadosa inspecci n de los mismos Los derechos y los beneficios del Cliente al amparo de este documento incumben exclusivamente al Cliente como comprador original de los Productos y no se pueden ceder ni transferir Ninguna otra parte o entidad lo cual incluye entre otros a los compradores o propietarios subsiguientes de los Productos tendr derecho de hacer valer ning n derecho o beneficio al amparo de la presente GARANT A LIMITADA EXCLUSIVA LIMITACI N DE REMEDIOS Por la presente Broan garantiza al Cliente que los motores de los Productos est n y se mantendr n por un periodo de dos 2 meses a partir de la fecha de entrega al Cliente y que los productos est n y se mantendr n por un periodo de seis
12. ER EL PRECIO DE COMPRA DE LOS PRODUCTOS ADEM S BROAN NO SER RESPONSABLE DE DA OS ESPECIALES INDIRECTOS INCIDENTALES O DE CONSECUENCIA DE NINGUNA NATURALEZA EN LO ABSOLUTO Broan se reserva el derecho de modificar alterar o mejorar cualquier producto o equipo fabricado por Broan sin incurrir en ning n deber u obligaci n de modificar alterar mejorar o reemplazar cualquiera de los productos cubiertos por la presente ESTA GARANT A ESTABLECE EL ACUERDO FINAL COMPLETO Y EXCLUSIVO DE LAS PARTES RELACIONADO CON LOS PRODUCTOS Y LAS OBLIGACIONES DE GARANT A DE BROAN NINGUNA AFIRMACI N DE HECHO PROMESA DESCRIPCI N DEMOSTRACI N MUESTRA O MODELO CONSTITUYE UNA GARANT A NI DE OTRA MANERA MODIFICA EXTIENDE O ALTERA ESTA GARANT A A MENOS QUE SEA MEDIANTE UN INSTRUMENTO POR ESCRITO FIRMADO POR UN FUNCIONARIO AUTORIZADO DE BROAN Esta Garant a estar regida e interpretada de conformidad con las leyes del estado de Wisconsin El medio para cualquier acci n que surja o se relacione con esta Garant a deber ser en el Condado de Washington Wisconsin Broan NuTone LLC Hartford Wisconsin www broan com 800 558 1711 79040170C
13. RANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THE WARRANTY SET FORTH IN THE PRECEDING PARAGRAPH AND THE OB LIGATIONS AND LIABILITIES OF BROAN THEREUNDER REPRESENT CUSTOMER S SOLE AND EXCLUSIVE REMEDIES AND ARE EXPRESSLY MADE IN LIEU OF ANY AND ALL OTHER REMEDIES WARRANTIES GUARANTIES OR LIABILITIES EXPRESS OR IMPLIED ALL OF WHICH ARE HEREBY EXPRESSLY WAIVED BY CUSTOMER THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO EVENT SHALL BROAN S LIABILITY HERE UNDER EXCEED THE PURCHASE PRICE FOR THE PRODUCTS ADDITIONALLY BROAN SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER Broan reserves the right to modify alter or improve any products or equipment manufactured by Broan without incurring any duty or obligation to modify alter improve or replace any of the Products covered hereby THIS WARRANTY SETS FORTH THE PARTIES FINAL COMPLETE AND EXCLUSIVE AGREEMENT CONCERNING THE PRODUCTS AND BROAN S WARRANTY OBLIGATIONS NO AFFIRMATION OF FACT PROMISE DESCRIPTION DEMON STRATION SAMPLE OR MODEL CONSTITUTES A WARRANTY OR OTHERWISE MODIFIES EXTENDS OR ALTERS THIS WARRANTY UNLESS IN A WRITTEN INSTRUMENT SIGNED BY AN AUTHORIZED BROAN OFFICER This Warranty shall be governed by and construed in accordance with the laws of the State of Wisconsin The venue for any action arising out of or related to this Warranty shall be in Washington Cou
14. ant toujours l avant trou de l tape 6 comme point central l aide d un clou et d une corde tracez un cercle de 35 6 cm 14 po de diam tre sur le papier noir ou le panneau du toit Remarque Si vous remplacez un ancien ventilateur le diam tre de l ouverture peut tre plus grand que 35 6 cm 14 po ce qui ne pose pas de probl me tant que la base du ventilateur est bien soutenue par les panneaux du toit 11 Pour enlever correctement les clous toiture tracez un carr de 68 6 cm 27 po de c t centr sur l ouverture Enlevez les clous retenant les bardeaux sur les deux tiers sup rieurs du carr MODELES 345SOBK 345SOWW Page 10 12 Appliquez un gros cordon d enduit a toiture dans la 14 Imperm abilisez les bardeaux et les t tes de clou rainure du dessous de la base du ventilateur Assurez a l aide d un enduit a toiture de bonne qualit vous que la base du ventilateur est parall le a la ligne N IMPERM ABILISEZ PAS le bord inf rieur de la base du faite glissez la base du ventilateur sous les bardeaux du ventilateur des deux tiers sup rieurs du carr de 68 6 cm 27 po Ne pliez pas les bardeaux plus que n cessaire Centrez la base du ventilateur sur l ouverture CLOUS SOUS LES BARDEAUX 15 Positionner le d me ventilateur de sorte que les points sup rieurs vers l ar te de toit Installez le d me du ventilateur sur la base du ventilateur l aide des quatre 4 vise t le enlev es
15. as Nota Si reemplaza un ventilador existente el di metro del orificio puede ser mayor de 16 1 2 pulg 42 cm Esto es aceptable siempre y cuando el material del techo se traslapa al ventilador por lo menos 2 pulg 5 cm en todos los lados 7 Recorte las tejas dentro del c rculo 8 Usando el mismo clavo y el cord n indicados en el paso 6 marque un c rculo de 14 pulg 35 6 cm de di metro sobre el papel negro o la cubierta del techo Nota Si reemplaza un ventilador existente el di metro del orificio puede ser mayor de 14 pulg 35 6 cm Esto es aceptable siempre y cuando la base del ventilador tenga un buen soporte en la cubierta del techo P gina 15 9 Perfore un orificio iniciador grande para la sierra de vaiv n justo dentro de la l nea o del c rculo de 14 pulg 35 6 cm creado en el paso 8 a Y 10 Recorte las tablas del techo dentro de la l nea 11 Para poder quitar adecuadamente los clavos del techo dibuje un cuadrado de 27 pulg 68 6 cm centrado alrededor del orificio Retire los clavos que sostienen las tejas desde los dos tercios superiores del cuadrado MODELOS 345SOBK 345SOWW P gina 16 12 Aplique un cord n grande de cemento para techo en 14 Con un buen cemento con grado para techo selle todas la ranura moldeada en la parte inferior de la base del las tejas y las cabezas de los clavos NO selle el borde ventilador Aseg rese de que la base del ventilador est in
16. ators and will not cause any damage to the structure We recommend that you do not store any valu able articles directly under the fan opening in the roof This ventilator is intended for roof installation Broan Models 353 345GOBK amp 345GOWW Gable Mount Ventilators are available for side wall applications The plastic ventilator dome and base may be painted with high quality paint Follow the paint manufacturer s recommen dations for acrylic and ABS plastic as appropriate Take care to avoid getting paint on the solar panel This ventilator includes a permanently lubricated motor Do not oil or disassemble The installation instructions contained in this document are only a recommendation and individual professionals may have their own methods of installation If your roof has an existing warranty installation of this product by anyone other than those who installed the roof may jeopardize any future warranty claim Please check with the original installer of your roof if this is a concern When working with asphalt shingles in cold weather below 40 F take care to avoid damage to the shingle edges and corners For installations in climates where cold weather condensation is not a concern Broan Model CWT45 thermostat is available It disconnects power to the motor when the temperature drops below 50 F Power is applied to the motor when the tempera ture reaches 61 F Register your product online at www broan com register
17. des bornes du moteur notez leur position en les d branchant L entr e d air recommand e pour ce ventilateur est de 0 19 m 2 pi Le meilleur emplacement de ces entr es d air est sous les avant toit acc dant directement au grenier N gliger d am nager de telles entr es d air risque d entra ner le refoulement des gaz des appareils de combustion L installation cr era une ouverture grillag e acc dant l espace du grenier Lors d un orage violent une fine bruine de pluie pourrait p n trer dans le grenier Ceci est normal pour tous les ventilateurs de grenier et n entra nera aucun dommage la structure Nous vous conseillons de ne pas ranger d objets de valeur directement sous l ouverture du ventilateur dans le toit Ce ventilateur est con u pour tre install sur un toit Les ventilateurs de pignon Broan mod les 353 345GOBK et 345GOWW sont disponibles pour les applications murales Le d me et la base en plastique du ventilateur peuvent tre peints avec une peinture de qualit sup rieure Suivez les recommandations du fabricant de la peinture pour l acrylique et le plastique ABS Evitez de mettre de la peinture sur le panneau solaire Ce ventilateur comporte un moteur lubrifi en permanence Il ne doit pas tre huil ni d mont Les directives d installation contenues dans ce document ne sont que des recommandations et des professionnels peuvent avoir leur propre m thode d installation Si votre toit est l
18. e side hereof the Products Customer acknowledges and agrees that he she is purchasing the Products for residential purposes and not for industrial or commercial purposes after careful inspection of the same Customer s rights and benefits hereunder inure solely to Customer as the original purchaser of the Products and are non assignable and non transferable No other party or entity including without limitation subsequent purchasers or owners of the Products shall have or be entitled to assert any rights or benefits hereunder EXCLUSIVE LIMITED WARRANTY LIMITATION OF REMEDIES Broan hereby warrants the Customer that the Products motors are and will remain for a period of two 2 years from the date of delivery to Customer and the Products are and will remain for a period of six 6 years from the date of delivery to Customer collectively the Warranty Period free of defects in materials and workmanship provided that such Products are used for their intended purpose and are properly serviced in accordance with the User s Manual provided to Customer Subject to the foregoing if at any time during the Warranty Period any Product fails to conform to the foregoing warranty by reason of defects in materials or workmanship Customer shall properly notify Broan in writing and shall include with such notice a sales receipt or proof of purchase of the defective Product and Broan at its option shall repair or replace the defective Product o
19. ferior de la base del ventilador paralela a la saliente del techo inicie en los dos tercios inferiores del cuadrado de 27 pulg 68 6 cm y deslice la base del ventilador debajo de las tejas No doble las tejas m s de lo necesario Centre la base del ventilador sobre el orificio CLAVE DEBAJO DE LAS TEJAS 15 Coloque el domo del ventilador por lo que los puntos principales hacia el caballete del tejado Instale el domo sobre la base del ventilador usando los cuatro 4 tornillos de l mina met lica que quit en el paso 3 Quite el cart n del panel solar y aseg rese de que el ventilador funcione 13 Aseg rese de que la base del ventilador est paralela a la saliente del techo y con cuidado levante las tejas y clave o atornille la base firmemente al techo usando clavos o tornillos galvanizados para techo Clave todas las esquinas y alrededor el per metro de la base cada 6 pulgadas 15 cm BROAN MODELOS 345SOBK 345SOWW PIEZAS DE SERVICIO Ahora se pueden hacer los pedidos de las piezas de repuesto en nuestro sitio Web Vis tenos en www Broan com Modelo Clave 345SOBK a A N Negro 77001311 CWT45 79310005 79080082 77001284 Modelo 345SOWW Madera curtida 77001313 CWT45 79310005 79080082 77001287 P gina 17 Descripci n Conjunto del panel solar domo Termostato opcional Aspa del ventilador con tornillo de fijaci n Motor CC Panel de hoja del techo BROAN MOD
20. isting 9 Drill a large starting hole for the sabre saw just inside of ventilator the hole diameter may be larger than 16 1 2 the line or the 14 circle created in Step 8 This is acceptable provided the roofing material overlaps the ventilator by at least 2 on all sides a Y 7 Cut out the shingles inside of the circle 10 Cut out the roof board s inside of the line 8 Using the same nail and string shown in step 6 scribe a 14 diameter circle on the black paper or roof decking Note if replacing an existing ventilator the hole diameter 11 For proper removal of roofing nails draw a 27 square may be larger than 14 This is acceptable provided the centered around the hole Remove nails holding shingles ventilator base is adequately supported by the roof down from top two thirds of square decking MODELS 345SOBK 345SOWW Page 4 12 Apply a large bead of roofing cement in the molded 14 Using a good grade of roofing cement material seal groove on the bottom side of ventilator base Make sure shingles and all nail heads DO NOT seal the bottom the arrow on the ventilator base is pointed toward the edge of the ventilator base roof ridge Start two thirds of the way down from the top of the 27 square and slide the ventilator base under the shingles Do not bend the shingles any more than necessary Center the ventilator base over the hole NAIL UNDER SHINGLES 15 Position the ventilator dome s
21. n utilities TOOLS AND MATERIALS REQUIRED O O O O O O O O O O O Drill 1 4 Drill Bit Sabre Saw or Keyhole Saw Hammer Ruler Tape Measure Pencil Marker or Scribe Utility Knife Pry Bar to remove roofing nails 5 16 Socket and Extension Roofing Cement Galvanized Roofing Nails 13 min Page 1 CAUTION 1 2 10 11 12 For general ventilating use only Do not use to exhaust hazard ous or explosive materials and vapors To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit This unit has an unguarded impeller Do not use in locations readily accessible to people or animals This ventilator operates when the solar panel is exposed to sun light To reduce risk of injury while installing servicing or cleaning unit cover the solar panel with cardboard or discon nect the wires from the motor terminals note wire locations when disconnecting The recommended open air inlet for this ventilator is 2 square feet The best location for these air intake vents are under the eaves with direct access to the attic Failure to provide these intakes could cause natural draft gas appliances to backdratt Your attic fan installation will create a screened opening into your attic space During a heavy rain storm there could be a light spray of rain into this attic space This is a normal condi tion with all attic ventil
22. nnait et convient qu il a achet les produits a des fins r sidentielles et non industrielles ou commerciales apr s les avoir soigneusement inspect s Les droits et avantages du client tels que stipul s ci dessous incombent uniquement au client en tant qu acheteur original des produits et ne sont ni cessibles ni transf rables Aucune autre partie ou entit y compris entre autres tout acheteur ou propri taire ult rieur des produits ne pourra pr tendre a aucun des droits et avantages ci dessous GARANTIE EXCLUSIVE LIMITEE LIMITATION DES RECOURS Par la pr sente Broan garantit au client que le moteur des produits est et demeurera pour une p riode de deux 2 ans a compter de la date de livraison au client et que les produits sont et demeureront pour une p riode de six 6 ans a compter de la date de livraison au client collectivement la p riode de garantie libres de tout vice de mat riau ou de fabrication condition que ces produits soient utilis s aux fins pour lesquelles ils ont t con us et aient t correctement entretenus conform ment au Manuel de l utilisateur fourni au client Eu gard ce qui suit si tout moment au cours de la p riode de garantie le produit n est pas conforme a la pr sente garantie en raison d un vice de mat riau ou de fabrication le client en informera Broan par crit en joignant le regu ou la preuve d achat du produit d fectueux afin que Broan puisse a sa discr tion r
23. nty Wisconsin Broan NuTone LLC Hartford Wisconsin www broan com 800 558 1711 79040170C BROAN MOD LES 345SOBK 345SOWW VENTILATEUR DE GRENIER A ENERGIE SOLAIRE MONTE SUR LE TOIT Page 7 AVERTISSEMENT A OBSERVEZ LES DIRECTIVES CI DESSOUS AFIN DE R DUIRE LES RISQUES D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES CORPORELLES 1 o N utilisez cet appareil que de la mani re pr vue par le fabricant Si vous avez des questions communiquez avec le fabricant a l adresse ou au num ro de t l phone indiqu s dans la garantie Avant d entretenir ou de nettoyer l appareil d sactivez le ventilateur en couvrant le panneau solaire d un carton ou en d branchant les fils des bornes du moteur notez leur position en les d branchant Les travaux d installation doivent tre effectu s par des personnes qualifi es conform ment a la r glementation et aux codes en vigueur notamment les normes de la construction ayant trait a la protection contre les incendies Si vous enlevez un ancien ventilateur lectrique de 120 VCA ne faites appel qu des personnes qualifi es pour enlever le c blage conform ment aux codes et aux normes en vigueur Pour viter les refoulements l apport d air doit tre suffisant pour br ler les gaz produits par les appareils combustion et les vacuer dans le conduit de fum e chemin e Respectez les directives du fabricant de l appareil de chauffage et les normes de s
24. o el personal calificado debe quitar el cableado el ctrico de acuerdo con los c digos y las normas locales wt 1 Determine la ubicaci n del techo con la mejor exposici n al sol y que no tenga sombra de rboles otros edificios etc a las 4 00 p m en el mes m s c lido del a o Por lo general recomendamos un punto situado de 24 a 36 pulg 61 a 91 cm por debajo del punto m s alto del techo y centrado a lo largo de la l nea del reborde sobre el lado sur suroeste u oeste de la casa 2 Antes de realizar la instalaci n recomendamos configurar el ventilador para verificar el funcionamiento Lleve el ventilador a un sitio expuesto al sol Quitar la cubierta de cart n del panel solar debe hacer que el ventilador funcione Asegure el cart n en su lugar sobre el panel solar por seguridad P gina 14 3 Separe el domo de la base quitando los cuatro 4 tornillos para l mina met lica Deje el domo a un lado 4 Desde el interior del tico encuentre la ubicaci n deseada para el ventilador y marque un punto a la mitad entre las vigas que se encuentre de 24 a 36 pulg 61 a 91 cm debajo del saliente del techo 5 Haga un orificio gu a a trav s del techo en esta marca MODELOS 345SOBK 345SOWW 6 Desde el lado del techo usando el orificio gu a como punto central use un clavo y un cord n para marcar un c rculo de 16 1 2 pulg 42 cm de di metro sobre las tej
25. o the top points toward the roof ridge Install the dome to the ventilator base using the four 4 sheet metal screws removed during step 3 Remove cardboard from the solar panel and make sure the ventilator operates 13 Make sure the ventilator base is parallel to the roof ridge carefully lift shingles and nail or screw base securely to the roof using galvanized roofing nails or screws Nail all corners and around perimeter of base every 6 inches BROAN MODELS 345SOBK 345SOWW SERVICE PARTS Replacement parts can now be ordered on our website Please visit us at www Broan com Model Key 345SOBK No Black 77001311 CWT45 79310005 79080082 77001284 a A N Model 345SOWW Weathered Wood 77001313 CWT45 79310005 79080082 77001287 Page 5 Description Solar Panel Assembly Dome Thermostat Optional Fan Blade w Set Screw Motor DC Roof Sheet Panel BROAN MODELS 345SOBK 345SOWW Page 6 WARRANTY BROAN NUTONE LLC Exclusive Limited Warranty The Exclusive Limited Warranty Agreement the Warranty is entered into by and between Customer and Broan NuTone LLC Broan Customer has carefully reviewed this Warranty and agrees that Broan s performance of its obligations hereunder will provide Customer with an adequate remedy which will serve the essential purpose of the parties agreement relating to the products manufactured by Broan and identified on the revers
26. objet d une garantie l installation de ce produit par des personnes autres que les couvreurs qui ont effectu les travaux du toit risque de compliquer toute r clamation future Veuillez consulter le couvreur original de votre toit pour d terminer s il peut y avoir un probl me ce sujet Si vous travaillez sur des bardeaux d asphalte par temps froid moins de 4 C prenez garde de ne pas ab mer les bords et les coins des bardeaux Pour les installations dans les r gions o la condensation par temps froid n est pas un probl me le mod le Broan CWT45 thermostat est disponible ll coupe le courant du moteur lorsque latemp rature descend moins de 10 C Le moteurestaliment en lectricit lorsque la temp rature atteint 16 C Enregistrez votre produit en ligne a www broan com register BROAN MOD LES 345SOBK 345SOWW INSTALLATION Remarque Ce ventilateur peut remplacer un ventila teur lectrique de 120 volts pour grenier Seule une personne qualifi e peut enlever le cablage conform ment aux codes et aux normes en vigueur OPT 3 DLLN A SS EA ETE el ee 1 D terminez l emplacement le plus expos au soleil sur le toit et sans ombre arbres autres batiments etc a 16 h dans le mois le plus chaud de l ann e En r gle g n rale nous recommandons un point situ a environ 61 a 91 cm 24 a 36 po au centre en dessous du faite du toit et centr sur le pan sud sud ouest
27. ombusti n y una extracci n adecuadas de los gases a trav s del tubo de humos chimenea del equipo quemador de combustible con el fin de evitar el contratiro Siga las directrices y las normas de seguridad del fabricante del equipo de calefacci n como las publicadas por la Asociaci n Nacional de Protecci n contra Incendios National Fire Protection Association NFPA y la Sociedad Americana de Ingenieros en Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las autoridades de los c digos locales Alcortaro perforar atrav s de la pared o del techo tenga cuidado de no da ar el cableado el ctrico ni otros servicios ocultos HERRAMIENTAS Y MATERIALES REQUERIDOS 0 00 0 IS 0 Taladro Broca para taladro de 1 4 pulg Sierra de vaiv n o sierra de calar Martillo Regla cinta de medir L piz o marcador Navaja utilitaria Barra de palanca para quitar los clavos del techo Dado de 5 16 pulg y extensi n Cemento para techo Clavos galvanizados para techo m nimo de 1 pulg 4 4 cm PRECAUCI N A 1 10 11 12 Solo para usarse como medio de ventilaci n general No debe usarse para la extracci n de materiales o vapores peligrosos o explosivos Para evitar da os a los cojinetes del motor y rotores ruidosos o desbalanceados mantenga la unidad de potencia protegida contra rociados de yeso polvos de construcci n etc
28. oumise et doit tre interpr t e conform ment aux lois de l tat du Wisconsin Toute action en justice d coulant de cette garantie ou y tant associ e doit avoir lieu dans le comt de Washington Wisconsin Broan NuTone LLC Hartford Wisconsin www broan com 800 558 1711 79040170C BROAN MODELOS 345SOBK 345SOWW VENTILADOR SOLAR PARA TICO DE MONTAJE EN EL TECHO P gina 13 ADVERTENCIA A PARA REDUCIR EL RIESGO DE INCENDIOS DESCARGAS ELECTRICAS O LESIONES PERSONALES SIGA LAS SIGUIENTES PRECAUCIONES 1 Use la unidad solo de la manera indicada por el fabricante Si tiene preguntas comun quese con el fabricante a la direcci n o al n mero telef nico que se incluye en la garant a Antes de dar servicio o de limpiar la unidad desactive el ventilador cubriendo el panel solar con cart n o desconectando los cables de las terminales del motor tome nota de las ubicaciones de los cables al desconectarlos Una o m s personas calificadas deben realizar el trabajo de instalaci n de acuerdo con todos los c digos y normas correspondientes incluidos los c digos y las normas de construcci n espec ficos de protecci n contra incendios Si va a quitar un ventilador el ctrico para tico de 120 VCA ya existente s lo personas calificadas deben quitar el cableado el ctrico de acuerdo con todos los c digos y las normas correspondientes Es necesario suficiente aire para que se lleve a cabo una c
29. parer ou remplacer ce produit ou l une de ses pi ces sans frais pour le client l exception A des co ts de transport du produit ou de ses pi ces du et au concessionnaire d sign par Broan ou a son usine de Hartford Wisconsin et B des frais de main d uvre ou autres co ts indirects relatifs a l enl vement ou au remontage des pi ces r par es ou remplac es en vertu de cette garantie lesquels sont a la charge du client Nonobstant toute disposition contraire des pr sentes cette garantie ne saurait obliger Broan a prendre des dispositions en ce qui a trait A des produits ayant t modifi s alt r s install s utilis s ou ayant servi d une mani re non recommand e par Broan y compris tout produit dans lequel des pi ces qui n ont pas t fabriqu es ou approuv es par Broan ont t install es B des produits qui n ont pas t r guli rement ou ad quatement entretenus conform ment au Manuel de l utilisateur ou qui ont t autrement n glig s et C usure normale les travaux de service et d entretien et les articles a remplacer CETTE GARANTIE NE SAPPLIQUE QUA LA MACHINERIE A LEQUIPEMENT ET AUX PIECES FABRIQUEES PAR BROAN ELLE NE SAPPLIQUE PAS A AUX PIECES ACHETEES SEPAREMENT DE LADITE MACHINERIE OU DUDIT EQUIPEMENT QUI SONT COUVERTES PAR UNE GARANTIE ECRITE DISTINCTE NI B AUX ARTICLES EQUIPEMENTS OU ACCESSOIRES FABRIQUES PAR DAUTRES PARTIES QUE BROAN SAUF CE QUI EST STIPULE AU PARAGRAPHE PRE
30. r component part without charge to Customer except for A costs incurred in transporting the Products or component parts to and from Broan s designated dealer or its manufacturing plant in Hartford Wisconsin and B charges for labor or other costs incidental to the removal or remounting of component parts repaired or replaced under this Warranty both of which shall be borne by Customer Notwithstanding any provision herein to the contrary this Warranty shall not extend or obligate Broan to take any action with respect to A Products which have been modified altered installed used or operated in a manner which is not recommended by Broan including any Products in which parts not manufactured or approved by Broan have been installed B Products which have not been regularly or properly serviced in accordance with the User s Manual or which have otherwise been neglected and C ordinary wear and tear service and maintenance and replacement items THIS WARRANTY APPLIES ONLY TO MACHINERY EQUIPMENT AND COMPONENT PARTS MANUFACTURED BY BROAN THIS WARRANTY DOES NOT APPLY OR EXTEND TO A PARTS PURCHASED SEPARATELY FROM SUCH MACHINERY AND EQUIPMENT WHICH ARE COVERED BY A SEPARATE WRITTEN WARRANTY OR B ITEMS OF EQUIPMENT OR ACCESSORIES MANUFACTURED BY PARTIES OTHER THAN BROAN EXCEPT AS SPECIFICALLY STATED IN THE PARAGRAPH IMMEDIATELY ABOVE BROAN MAKES NO WARRANTY OR REP RESENTATION EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WAR