Home
NuTone 605RP Installation Guide
Contents
1. removed in Step 4 under PRE PARE THE UNIT on Page 2 Plug fan assembly into recep tacle C on the the side of the wiring cover Direct wires away from blower inlets 7 Replace the heater assembly removed in Steps 2 3 under PREPARE THE UNIT on Page 2 Plug heater assembly into receptacle A Direct wires away from blower inlets 8 Install grille and grille bracket Tighten acorn nut securely Be careful not to overtighten nut Install grille cover Gently squeeze tabs on cover and insert them into the slots in the grille N ulo n e MODEL 605RP SERVICE PARTS KEY NO PART NO DESCRIPTION 1 97017451 Housing 2 101183000 Damper Duct Connector 3 44388000 Mounting Bracket 4 Req 4 99270982 Receptacle Black 99270489 Receptacle Red 5 82403000 Fan Blower Wheel 6 99080592 Fan Motor 7 97017080 Fan Motor Plate Assembly 8 99260428 Nut 4 Req 9 97017824 Grille Assembly includes Key No 12 10 85604000 Grille Bracket 11 97005316 Acorn Nut 12 53741000 Grille Cover 13 97005058 Bolt Assembly 14 99020134 Heater Blower Wheel 15 99150576 8 x 3 8 Sheet Metal Screw 9 Req 16 93260457 10 32 Nut 7 Req 2 included in Key No 16 17 99270107 Heater Hooks 5 Req 18 98010295 Heater Scroll Cover 19 97017070 Heater Scroll Housing 20 99080593 Heater Motor 21 98004514 Heater Element 22 99260512 Tinnerman Nut 23 99420666 Wire Clip 2 Req 24 98010286 Exhaust Fan Scroll Band WARRAN
2. NuTone MODEL 605RP HEATER FAN WARNING A TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR IN JURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufac turer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the ser vice disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhaust ing of gases through the flue chimney of fuel burning equip ment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code au thorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Do not use this unit with any solid st
3. SPECIAL DAMAGES ARISING OUT OF ORIN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states donot allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties WARRANTY SERVICE To qualify for warranty service you must a notify Broan NuTone at the address or telephone number below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Date of Installation Builder or installer Model No and Product Description IF YOU NEED ASSISTANCE OR SERVICE CONTACT Broan NuTone LLC Hartford Wisconsin www nutone com 888 336 3948 Rev 08 2007 99044042F
4. TY One Year Limited Warranty WARRANTY OWNER Broan NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one 1 year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES FILTERS DUCT ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR
5. ate speed control de vice 8 Never place a switch where it can be reached from a tub or shower 9 Use this unit only in the manner intended by the manufac turer If you have questions contact the manufacturer 10 This unit must be grounded CAUTION 1 Provide a separate 15 AMP circuit Use 14 GA power cable of type which meets code 2 This product is designed for ceiling installation only This product is designed for installation in ceilings up to a 12 12 pitch Ductwork must point up DO NOT MOUNT THIS PRODUCT IN A WALL Install in ceiling only at least 12 from any wall 4 For greatest efficiency install heater so heat is directed to ward tub or shower area Avoid directing toward walls or win dows 5 For general ventilating use only Do not use to exhaust haz ardous or explosive materials and vapors 6 To avoid motor bearing damage and noisy and or unbal anced impellers keep drywall spray construction dust etc off power unit 7 Please read specification label on product for further infor mation and requirements w READ AND SAVE THESE INSTRUCTIONS Page 1 To register this product visit www nutone com USE AND CARE DISCONNECT ELECTRIC POWER SUPPLY BEFORE CLEAN ING OR SERVICING THIS UNIT TO CLEAN LENS AND GRILLE Remove lens as explained above Remove bulb Remove acorn nut in center of light reflector and lower assembly Unplug light CAUTION Grille and reflecto
6. he slots on each end of the housing 2 hanger bars per side INSTALL THE UNIT For best results choose a location which allows fan to be vented outside with the shortest possible duct run and the fewest num ber of elbows 1 Position unit between joists and extend mount ing brackets Position brackets such that the Page 2 bottom edge of housing will be flush with finished ceiling Mark the top of keyhole slot on all four mounting brackets 2 Remove unit tem porarily and pound nails partially into joists at all four marked locations Hang unit from nails and check if unit will be flush with finished ceiling Pound nails tight For wide joist centers A 8 x 3 8 self tapping screw can be used to join extended brackets together and cre ate a rigid mount To ensure a noise free mount crimp the bracket channels tightly around mounting brackets MODEL 605RP 4 Use a flat bladed screwdriver to remove the proper electrical knockouts Connect electrical wiring as 2 GROUND WIRES DEA S awae Le 5 g WIRES ATA 3 GROUND WIRES 120 VAC LINE IN Page 3 If the switch has not been wired properly and wires need to be moved Each wire opening has a release slot Push a smal nail or screwdriver into release slot while gently removing wire DO NOT pull any wire out of the switch without using the release slot The switch may be damaged 6 Replace the fan assembly
7. r are separate units Plastic parts can be cleaned with mild soapy water and dried with a soft cloth DO NOT USE ABRASIVE CLOTHS STEEL WOOL PADS OR SCOURING POWDERS TO CLEAN FAN ASSEMBLY Unplug fan motor Remove retaining screws CAUTION Fan assembly will swing downward when screws are removed Support the fan assembly with a free hand while re moving retaining screws Gently vacuum fan motor and interior of housing Motor is per manently lubricated and never needs oiling TO CLEAN HEATER ASSEMBLY Unplug heater Remove retaining screw Place a screwdriver tip between outer wall of housing and heater exhaust opening Gently pry outward until exhaust housing slips out CAUTION Unit will swing downward when released Support with the heater assembly with a free hand while prying with screwdriver Gently vacuum blower motor and interior of housing Motor is permanently lubricated never needs oiling METAL AND ELECTRICAL PARTS SHOULD NEVER BE IM MERSED IN WATER TO REASSEMBLE ALL ABOVE PARTS Reverse all procedures explained above Assemblies should not be disassembled any further than explained above Nulone MODEL 605RP PREPARE THE UNIT 1 Remove the grille bracket Remove the heater assembly retaining screw 3 Rotate heater assembly and lift it up and out of the housing Remove fan assembly retaining screws Lift fan assembly out of the housing Slide the 4 hanger bars into t