Home
Broan 671 Instructions / Assembly
Contents
1. MAKE SURE HOUSING WILLBE FLUSH WITH FIN ISHED CEILING OR WALL Slotted tabs are provided tolocate housing flush with 1 2 ceiling or wall material Bend tabs outward 90 Use a screw driver if desired and position housing so that tabs rest against bottom edge of joists or front of stud Nail housing to joist or stud using four nails to ensure a solid quiet installation Ceiling installations Tabs on opposite side of hous ing can be bent outward to rest on top of 1 2 ceiling materia and provide extra stability FIG 4 5 Replacement installation Position housing so that it is centered in existing opening MAKE SURE HOUSING IS FLUSH WITH FINISHED CEILING OR WALL After making electri cal and ductwork connections see steps 4 5 and 6 na l housing in place Drive nails through the housing where indicated by arrows FIG 5 5 New installation in an existing ceiling or wall From above ceiling or behind wall position housing against stud or joist Trace outline of housing on ceiling or wali material FIG 6 Set housing aside and cut opening Place housing in opening such that its BOT TOM EDGE IS FLUSH WITH FINISHED CEILING OR WALL 1 2 ceiling or wall material Bend tabs outward 90 use a screwdriver if desired to rest on top of ceiling or wall material and provide extra stability Nail in place using four nails to ensure a solid quiet instal lation FIG 7 6 instali 3 round duct onto damper duct connector If
2. rigid ductworkis used its seam shoutd be positioned at top of damper duct connector Tape the joint and extend ducting to a wall cap or roof cap Make sure the damper operates freely Ceiling or wall can now be finished NOTE if damper detaches from duct connector re insertitby squeezing duct connector top to bottom while guiding posts on damper flap into holders in duct connector The horizontal rib should be on the outside surface of damper flap and damper flap should move freely inside of duct connector 7 Replace the motor plate removed in Step 1 Insert two motor plate tabs into slots in housing and then pivot motor plate up until the third tab on plate snaps into matching slot in housing Make sure tabs hold motor plate securely in place Plug in motor FIG 8 8 Squeeze grille springs together and insert springs into slots in motor plate FIG 9 Push grille up against ceiling or wali FIG 10 BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date oforiginal purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOTLIMITEDTO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Duringthis one year period Broan will at its option repair or replace without charge any product or part which is tound to be defective under n
3. al tiempo que gu a los postes de la aleta para introducirlos en el soporte del conectador El saliente horizontal debe quedar en la superficie externa de la aleta del regulador de tiro y sta debe poder moverse libremente dentro del conectador del conducto Reemplace la placa del motor que fue removida en el paso 1 Inserte dos pesta as de la placa del motor dentro de las ranuras en la caja y entonces jale usando la placa del motor como pivote hasta que la tercera pata de la placa encaja en la ranura correspondiente de la caja Aseg rese de que las pesta as sostienen la placa del motor de forma segura Conecte el motor FIG 8 Presione conjuntamente los resortes de la parrilla e ins rtelos dentro de las ranuras de la placa del motor FIG 9 Empuje la parrilla contra el techo o pared FIG 10 GARANT A BROAN LIMITADA POR UN A O Broan garantiza al consumidor comprador original de sus productos que dichos productos carecer n de defectos en materiales o en mano de obra por un periodo de un a o a partir de la fecha original de compra NO EXISTEN OTRAS GARANTIAS EXPRESAS O IMPL CITAS INCLUYENDO PERO NO LIMITADAS A GARANT AS IMPL CITAS DE COMERCIALIZACION O APTITUD PARA UN PROP SITO PARTICULAR Durante el per odo de un a o y a su propio criterio Broan reparar o reemplazar sin costo alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso ESTA GARANT A NO
4. present evidence of the original purchase dale Broan NuTone LLC 926 West State Street Hartford Wi 53027 97011723 Grille Assembly Includes Key Nos 2 12 Grille Spring 2 Required 99140187 Motor Model 670 99080254 Motor Model 671 671MX 99080255 Motor Model 688 97012041 Motor Model 689 97012042 Motor Plate 98006791 Blower Wheel Model 670 671 671MX 99020292 Blower Wheel Model 688 amp 689 99111002 Nut 46 32 2 Required 99260428 Damper Duct Connector 97016377 Models 670 671 671MX 688 689 Damper Duct Connector 97015577 Model 1667HMTL Receptacle 99271252 Wiring Cover 98006773 Housing Assembly 97008319 Screw 8 18 99150478 Always order replacement parts by PART NUMBER not by KEY NO SERVICE PARTS KEY PART NUMBER NO NO PIEZ FIG 10 SERVICE PARTS PIEZAS DE SERVICIO Replacement parts can now be ordered on our website Please visit us atwww Broan com Las piezas de recambio se pueden ahora pedir en nuestro Web site Visitenos por favor en www Broan com NO C DIGO 1 Ensamble de la parrilla incluye c digo Nos 1 y 2 Resorte de la parrilla Son necesarios 2 Motor Modelo 670 Motor Modelo 671 671MX Motor Modelo 688 Motor Modelo 689 Placa del motor Rotor de soplo Modelo 670 671 671MX Rotor de soplo Modelo 688 y 689 Tuerca No 6 32 Son necesarias 2 Co
5. ALACI N 1 Remueva la placa del motor de la caja empujando hacia abajo sobre la costilla de la placa a la vez que se jala hacia afuera del lado de la caja La placa del motor puede tambi n removerse introduciendo un desarmador en la ranura de la caja y haci ndolo girar FIG 1 2 Retire la cubierta de la caja empujando directamente hacia el exterior La unidad se env a lista para tender el alambrado desde la parte superior de la caja Para alambrar a trav s de uno delos lados doble la solapa de la caja hasta cubrir el agujero superior y exponer el agujero lateral NO ROMPA LA SOLAPA Si la solapa se rompe cubra el agujero que no se utiliza con tapones el ctricos estan FIG 3 Apaque la fuente de energ a el ctrica de la entrada de servicio y conecte el cable de energ a el trica en la caja usando la conexi n appropiada El alambre negro con nergo y el blanco con blanco y verde a verde o alambra desnudo Empuje todo el alambre hacia arriba y hacia la esquina de la unidad y reemplace la cubierta de la unidad Aseg rese de que la cubierta sostiene la solapa de la caja en su lugar contra la parte lateral o superior de la caja PRECAUCI N NO PERMITA QUE LOS ALAMBRES SE EXTIENDAN HACIA EL EXTERIOR DE LA CAJA DE ALAMBRADO El alambre que quede expuesto puede ser rasgado o cortado cuando se instale la placa del motor Esto puede dar como resultado una descarga el ctrica FIG 3 v Nur install xtion priorto finishing the ceiling or wall
6. CUENTRE AL NIVEL DEL TECHO O LA PARED Despu s de hacer las conexiones el ctricas y del ducto de trabajo Vea los pasos 4 5 y 6 clave la caja en el lugar escogido Coloque los clavos en los lugares marcados con una flecha FIG 5 Instalaci n nueva en un techo o pared existentes Desde arriba del techo o detr s de la pared coloque la caja contra la viga o travesa o Marque los contornos de la caja en el material deltecho o pared FIG 6 Ponga de lado la caja y corte la abertura Coloque la caja en la abertura de forma que EL EXTREMO DEL FONDO SE ENCUENTRE A NIVEL CON EL TECHO ACABADO O LA PARED 1 2 de techo o material de pared Doble las pesta as 90 grados hacia el exterior use un desarmador si as lo desea para descansar encima de techo o material de pared y proporcionar as una mayor estabil idad Clave en su lugar utilizando cuatro clavos para asegurar una instalaci n s lida y silenciosa FIG 7 Instale ducto redondo de 3 en la conexi n del humidifi cador ducto Si se utiliza ducto de trabajo r gido su costura debera colocarse en la parte superior del humid ificador ducto Encinte la uni n y extienda el ducto hacia latapa de la pared o la tapa del techo Aseg rese de que el humidificador funciona libremente El techo o pared pueden entonces ser acabados NOTA Sila aleta del regulador de tiro se desprende del conectador del conducto vuelva a introducirla comprimiendo el conectador de arriba a bajo
7. E DAR SERVICIO A LA UNIDAD Po WIRING COVER CUBIERTA DEL ALAMBRADO 0 VERDE O a PLACKTO lane BLACK DESNUDO NEGRO A Un ventilador limpio proporciona mejor servicio Desconecte el suministro el ctrico y limpie el ventilador de la siguiente manera PARA LIMPIAR LA REJILLA L vela con detergente suave tal como liquido para lavar vajilla s quela con un pa o suave NO USE PANOS ABRASIVOS ALMOHADILLAS DE LANA DE ACERO NI POLVOS ABRASIVOS PARA LIMPIAR El CONJUNTO DEL VENTILADOR Desconecte el cable del motor de su recept culo Para quitar la placa del motor Localice la aleta nica de la placa del motor se encuentra junto al recept culo Empuje hacia arriba cerca de la aleta de la placa del motor mientras empuja hacia afuera el costado de la cubierta O bien introduzca un destornillador de punta recta en la ranura de la cubierta junto a la aleta y haga girar el destornillador Con una aspiradora limpie suavemente el ventilador el motor y el interior de la cubierta NO SUMERJA NUNCA EN AGUA LAS PIEZAS METALICAS NI LAS EL CTRICAS PARA VOLVER A MONTAR TODAS LAS PIEZAS ANTERIORES Haga el procedimiento que se acaba de explicar pero en orden invertido MANTENIMIENTO El motor est permanentemente lubricado y nunca necesitar aceite Si los cojinetes del motor est n haciendo ruido excesivo o inusitado reemplace el motor con el motor de servicio exacto Al mismo tiempo debe reemplazar el pist n impulsor INST
8. M DEI S a10 671 671MX 688 amp 689 CEILING WALL FANS READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent waming device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards 4 Sufficient airis needed for proper combustion and exhausting of gases through the flue chimney of fuel buming equipment to prevent backdrafting Follow the heating equipment manufactur er s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the Amer ican Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Accepta
9. SE APLICA A TUBOS Y ARRANCADORES DE LAMPARAS FLUORESCENTES Esta garantia no cubre a mantenimiento y servicio normales o b cualquier producto o piezas que hayan sido utilizadas de torma err nea negligente que hayan causado un accidente o que hayan sido mantenidas o reparadas inapropladamente por otras compa as que no sea Broan instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a un periodo de un a o como se especifica en la garantia expresa Algunos estados no permiten limitaciones en cuanto altiempo de expiraci n de una garantia implicita porlo quelalimitacion antes mencionada puede no aplicarse a usted OBLIGACI N DE BROAN DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITE RIO DE BROAN DEBERA SER EL NICO Y EXCLUSIVO RECURSO LEGAL DEL COMPRADOR BAJO ESTA GARANT A BROAN NO SER RESPONSABLE POR DANOS ACCIDENTALES CONSIGUIENTES O POR DANOS ESPECIALES SURGI DOS O EN CONEXI N CON EL USO O EL RENDIMIENTO DEL PRODUCTO Algunos estados no permiten ta exclusi n o limitaci n de da os accidentales o consiguientes por lo que la imitaci n antes mencionada puede no aplicarse a usted Esta garantia le proporciona derechos legales espec ficos y usted puede tambi n lener otros derechos los cuales var an de estado a estado Esta garantia reemplaza todas las garantias anteriores Para calificar en el servicio de garantia usted debe a no
10. ble for use over a bathtub or shower when installed in a GFC protected branch circuit 8 Install fan at least five feet 1 52 m above the floor 9 Never place a switch where it can be reached from a tub or shower 10 This unit must be grounded CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 3 Please read specification label on product for further information and requirements USE AND CARE DISCONNECT ELECTRIC POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SER VICING THE UNIT PREVENTATIVE MAINTENANCE A clean fan provides better service Disconnect the power supply and clean the fan as described below TO CLEAN GRILLE Use a mild detergent such as dishwashing ligquid and dry with a soft cloth DO NOT USE ABRASIVE CLOTHS STEEL WOOL PADS OR SCOURING POWDERS TO CLEAN FAN ASSEMBLY Unplug motor cord from receptacle To remove motor plate Find the single tab on the motor plate located next to the receptacle Push up near motor plate tab while pushing out on side of housing Or insert a straight blade screwdriver into slot in housing next to tab and twist screwdriver Gently vacuum fan motor and interior of housing METAL AND ELEC TRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER TO REASSEMBLE ALL ABOVE PARTS Reverse all proced
11. nexi n humidificador Ducto Modelos 670 671 671MX 688 y 689 Conexi n humidificador Ducto Modelos 1667HMTL Recept culo Cubierta del alambrado Ensamble de la caja Tornillo 8 18 Siempre encargue piezas de reemplazo por NO PIEZA y no por NO C DIGO 4 Escoja la posici n de su ventilador PIEZAS DE SERVICIO Para un mayor rendimiento use el ducto m s corto posible y un n mero m nimo decodos Para instalaciones enla pared Coloque la unidad de forma que la tapa del humidificador se cierre cuando la unidad se encuentre apagada Instalaci n nueva antes de poner los acabados del techo o la pared ASEGURESE DE QUE LA CAJA SE ENCUENTRE AL NIVEL DEL TECHO O LA PARED Se proporcionan pesta as ranuradas para nivelar la caja con 1 2 del techo o material de la pared Doble las pesta as hacia afuera a 90 grados use un desarmador si asilo desea y coloque la caja de forma que las pesta as descansen contra el extremo delfondo de los travesa os o del frente de la viga Clave la caja al travesa o usando cuatro clavos para asegurar una instalaci n s lida y silenciosa instalaciones en techos las pesta as que se encuen tran en la parte opuesta de la caja pueden doblarse hacia afuera hasta descansar encima de 1 2 de material de techo para proveer estabilidad adicional FIG 4 Instalaci n de reemplazo Coloque la caja de forma que est centrada en la abertura existente ASEGURESE DE QUE SE EN
12. on unit so damper flap closes when unit is off FIG 1 SCREWDRIVER SLOT RANURA PARA DESARMADOR 4 HOUSING FLAP SOLAPA DE LA CAJA SWITCH BOX SWITCH OR TIMER INTERRUPTOR O BRSOAN To register this product visit www broan com RECEPTACLE a RECEPT CULO HTI INTERAUPTORES E BA 120 VAC LINE IN LINEA DE ENTRADA A120 VCA MODELOS 670 671 671MX 688 Y 689 VENTILADORES DE TECHO LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA EL CTRI cao LESIONES A PERSONAS CUMPLA LOS SIGUIENTES PUN 1 Solamente use esta unidad de la manera propuesta por el fabri cante Si tiene alguna pregunta p ngase en contacto con el fabricante en la direcci n o tel fono anotados en la garant a Antes de limpiar o de poner en servicio la unidad apague el interruptor en el panel de servicio y asegure el panel de servicio para evitar que se encienda accidentalmente Cuando el dispositivo para desconectar el servicio el ctrico no puede ser cerrado con alg n tipo de traba sujete fuertemente al panel de servicio una etiqueta de advertencia prominente El trabajo de instalaci n y el alambrado el ctrico deben llevarse a cabo por personal calificado de acuerdo con todos los c digos y las normas aplicables incluyendo los c digos y normas de construcci n contra incendios 4 Se requiere una cantidad de aire suficiente para la combusti n y escape de gazes por l
13. ormal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This waranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited lo the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so Ihe above limitation may not apply to you BROAN SOBLIGATIONTO REPAIR OR REPLACE AT BROAN S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan at the address stated below or telephone 1 800 637 1453 El que the model number and part identification and c describe the nature ol any delectin the product or part At the time of requesting warranty service you must
14. tificar a Broan al domicilio que se menciona abajo o al telefono 1 800 637 1453 b dar el n mero del modelo y la identificaci n de la pieza y c describir la naturaleza de cualquier defecto en elproducto opieza Enelmomento de solicitar servicio cubierto porta garantia usteddebe presentar evidencia de la fecha original de compra Broan NuTone LLC 926 West State Streel Harttord Wi 53027 U S A 61574 99043688B
15. ures explained above MAINTENANCE The motor is permanently lubricated and never needs oiling if the motor bearings are making excessive or unusual noises replace the motor with the exact service motor You should replace the impeller at the same time INSTALLATION 1 Remove motor plate from housing by pushing down on rib in plate while pulling out on side of housing Motor plate may also be removed by inserting a straight blade screw driver into slot in housing and twisting screw driver FIG 1 2 Remove wiring cover from housing by pulling straight out Unit is shipped ready to wire through the top of housing To wire through the side bend housing flap to cover top hole and expose side hole DO NOT BREAK OFF FLAP if flap breaks Plug unused hole using standard electrical hole plug FIG 2 3 Turn off electrical power at service entrance and connect power cable to housing using appropriate connector Wire black to black white to white and green to green or bare wire Push all wiring up into comer of unit and replace wiring cover Make sure cover holds housing flap in place against side or top of housing CAUTION DO NOT ALLOW WIRES TO EXTEND OUTSIDE OF WIRING BOX Wire left exposed will become pinched or cut when motor plate is installed Electrical shock may result FIG 3 4 Choose the location for your tan For best performance use the shortest possible duct run and a minimum number of elbows For wall installations Positi
16. z chimenea del equipo de quemado de combustible para evitar salirse de las especificaciones y est ndares de seguridad del fabricante tales como los publicados por la Asociaci n nacional de proteci n contra incendios NFPA por sus siglas en Ingl s y la Sociedad americana de ingenieros de calefac ci n refrigeraci n y aire acondicionado ASHRAE por sus siglas en Ingl s y los c digos de las autoridades locales WHITE TO 5 Cuande corte o taladre en una pared o techo no da e los cables el ctricos ni otras instalaciones ocultas 6 Los ventiladores con ductos siempre deben de ventilar hacia el exterior 7 Aceptable si se lo usa por encima de una tina o ducha instaladas en un circuito derivado protegido GFCI con interruptor accionado por corriente de p rdida a tierra 8 Inst lelo por lo menos a 152 cm sobre el piso 9 NUNCA coloque un interruptor donde pueda ser alcanzado desde la ba era o la ducha 10 Esta unidad debe conectarse a tierra PRECAUCI N 1 S lo para uso de ventilaci n general No se use para extraer materiales o vapores peligrosos o explosivos 2 Para evitar da os al cojinete del motor y o impulsores ruidosos o desequilibrados mantenga la fuente de potencia lejos de rocfos de pared seca de polvo de construcci n etc 3 Lea la etiqueta de especificaciones en el producto para mayor informaci n y requisitos USO Y CUIDADO DESCONECTE EL SUMINISTRO EL CTRICO Y BLOQUEE EL PANEL DE SERVICIO ANTES D