Home

Vigo VG6042RBCL60 Installation Guide

image

Contents

1. Prior to any installation mark lines on the floor and wall for proper dry fit Using painter s tape is a suggested method Although the panels are parallel the fixed panel does not sit in alignment with the door and side panel Proper planning is imperative for proper installation SEE FIG 1A INSTALLATION STEPS USING TYPE A FOR ILLUSTRATION A INSTALLING THE FRONT FIXED PANEL 1 Arrange the front fixed panel 5 to the preferred configuration to determine the orientation of glass supports 29 2 Install the side seal strip 7 to the wall side of the front fixed panel SEE FIG 2 3 Screw in the glass support with the hex key to the front fixed panel Be sure to use washers on both sides of the panel SEE FIG 2 4 Mark holes on the wall for the mounting screws after leveling panel SEE FIG 2 5 Remove the front fixed panel and drill holes into the wall Insert plastic anchors 17 into the holes Not necessary if installing into studs Studs are the preferred means of installation anchors can pull out of the wall causing property damage and bodily harm There is a 10mm adjustment built into the glass supports for minor modifications 6 Replace the front fixed panel Screw into the wall with 1 5 8 hex screws 13 STUD 3 8 5 8 THIN GASKETS WALL SIDE FIG 2 MODEL VG06042 bh N INSTALLING THE TURNING HINGE BASE Unscrew the plate on the turning hinge base mirrored 2
2. and mount the turning hinge base mirrored into the lower corner of the front fixed panel 5 Mark a hole on the floor for the mounting screw for the turning hinge base mirrored Remove the turning hinge base mirrored and drill a hole into the floor on the marked location Insert plastic anchor 16 into the hole Mount the turning hinge base mirrored again carefully cover the plate and tighten the screw supplied from inside the shower SEE FIG 3 Screw the turning hinge base mirrored into the floor with 1 1 8 Phillips screw 15 Make sure the glass panel is perpendicular to the wall Remove the screw that connects the structural arm on the floor mount portion of part 2 Removing this is to prevent personal injury silicone the void to prevent water entry SEE FIG 3A Mount the turning hinge base 1 to the upper corner of the front fixed panel cover the plate and tighten the screw supplied from inside the shower FIG 3A MODEL VG06042 INSTALLING THE STRUCTURAL ARM Attach the structural arm 30 to the top turning hinge base 1 Note that the structural arm has an adjustable screw hole of 1 2 length This will allow for flexibility and proper install placement SEE FIG 4 amp 4A Mark two holes on determined locations on the wall for the mounting screws and insert plastic anchors 16 into them Resecure the structural arm to the turning hinge base and tighten the screw supplied c
3. user may also have other rights which can vary from one state or province to another Warranty Service In order to obtain service provided under this warranty during regular business hours contact the dealer or distributor who sold the unit or contact VIGO directly VIGO will provide the warranty service described above when the following conditions have been met the failure is of the nature or type covered by the warranty the user has informed an authorized VIGO Agent or VIGO s warranty service department representative of the nature of the problem during the warranty period conclusive evidence e g proof of purchase or installation is provided to the foregoing by the user proving that the failure occurred or was discovered within the warranty period an authorized independent service person or company representative has been permitted to inspect the product during regular business hours within a reasonable time after the problem was reported by the user VIGOs warranty obligation shall be discharged upon tender of replacement or repair The customer s refusal to accept the tender terminates VIGO s warranty obligations Certain models are pending approval Certification may be ended by VIGO or certification agencies without notice 15 MODEL VG06042
4. IC ANCHORS WHITE 98038 a 18 SIDE PANEL 97025 12 97025 24 21 SHELF GLASS HOLDER TO WALL 98055 Y 6 22 SHELF GLASS HOLDER TO GLASS 98056 9 Y 23 F SHAPED SEAL STRIP 73 96015 19 DOOR MAGNETIC SEAL STRIP 73 9601 1 24 SCREW COVER D 9 9 98050 98049 TYPEA 98048 20 SHELF GLASS 97026 25 RIGHT THRESHOLD CLIP W SCREW HOLE 98057 E 26 LEFT THRESHOLD CLIP W SCHEW HOLE 98058 Y 27 RIGHT THRESHOLD END CUP A 98051 29 GLASS SUPPORT 98053 28 LEFT THRESHOLD END CUP OR 98052 d 30 STRUCTURAL ARM 98054 31 ALLEN KEY PACK MISC PART USED IN REPLACEMENT OF 19 MAGNETIC SEAL STRIPS ONLY WHEN PART 18 SIDE PANEL IS NOT INSTALLED THIS IS AN OPTION THE VGOG042 MODEL OFFERS MODEL VG06042 CONFIGURATIONS LIST DIMENSION A DIMENSION DIMENSION HEIGHT DIMENSIONS DOOR PANEL FRONT FIXED SIDE PANEL PANEL 1 a2 48 x 72 28 3 4 x 71 1 4 7 7 8 x 72 12 x 72 48 54 x 72 34 3 4 71 1 4 7 7 8 x 72 ia 54 60 x 72 60 66 x 72 34 3 4 x 71 1 4 7 7 3 72 24 x 72 A means the door panel opens to the left while Type B means to the right Vigo brand shower bases are available for the VGO6042CL48 and VGO6042CL60 models They can only be used when the shower enclosure is installed at max
5. S 15 e DOOR THRESHOLD 28 p ALIGNS WITH 11 P d 1 lt SIDE PANEL 16 d 12 MODEL VG06042 J K INSTALLING SCREW COVERS 1 Install screw covers 24 to the unit Please pay attention that there are three types of covers Type A is for structural arm 3pc and left threshold clip with screw hole 1pc Type B is for turning hinges 6pc Type C is for glass supports 8pc APPLYING THE SILICONE 1 Apply clear silicone caulking to the inside between the wall and side seal strip Repeat for the other side SEE FIG 1 1 2 Apply clear silicone caulking to the inside between the floor and the fixed front panel Continue applying the silicone caulking around the turning hinge base mirrored to seal any place that may cause leaking 3 Apply clear silicone caulking to the inside between the floor and left threshold end cup door threshold right threshold clip with hole and the bottom of side panel 6 y p Bu S O O N IMPORTANT e WAIT 24 HOURS BEFORE USING SHOWER e DO NOT ALLOW WATER TO DIRECTLY HIT DOOR SEAL STRIPS CLEANING INSTRUCTIONS FOR THE SHOWER CABIN AND DOOR PANEL A Use mild liquid household cleaners to keep metal surface bright and clean Rinse well and dry with a clean cloth Hemove dust with a soft damp cloth Use rubbing alcohol to clean and remove grease oil paint and ink Accidental scratches or stains will rarely show If they do sho
6. Turning hinge mirrored 1pc b iud dii Spc 16 Plastic anchor green 9pc 5 Front fixed panel 1pc 17 Plastic anchor white 4pc oo 18 Side panel 1pc Si strip 2 30 REED 19 Door magnetic seal strip 2pc 20 Shelf glass 2pc 4 14 21 Shelf glass holder to wall 4pc 22 Shelf glass holder to glass 2pc 23 F shaped seal strip 1pc optional 24 Screw cover Type A 3pc Type B 8pc 9 or 12 Type C 8pc 25 Right threshold clip w screw hole 1pc 3 6 26 1 threshold clip w screw hole 1pc 27 Right threshold end cup 1pc 28 Left threshold end cup 1pc 23 29 Glass support 4pc 80 Structural arm 1pc 31 Allen key pack 1 pack GLASS THICKNESS 3 8 NOTE INSTALLATION MUST BE DONE BY A QUALIFIED LICENSED PROFESSIONAL D MODEL VG06042 VIGO 1 TURNING HINGE BASE 98041 4 2 TURNING HINGE BASE MIRRORED yo 98042 3 TURNING HINGE 98043 4 TURNING HINGE MIRRORED 98044 5 FRONT FIXED PANEL 97023 6 DOOR 97024 28 97024 34 7 SIDE SEAL STHIP 73 96001 8 HANDLE ASSEMBLY 98012 18 9 SIDE SEAL STRIP W OUT BUMP 73 96014 10 DOOR BOTTOM SEAL STRIP 36 96004 A 11 DOOR THRESHOLD 98046 12 DOOR SIDE SEAL STRIP 73 96013 13 HEX SCHEW 1 5 8 98047 14 PHILLIPS SCREW 1 5 8 98039 15 PHILLIPS SCHEW 1 1 8 16 PLASTIC ANCHORS GREEN 98037 N 17 PLAST
7. VIGO INDUSTRIES INSTALLATION GUIDE FOR SHOWER ENCLOSURE MODEL VG06042B SAFETY PRECAUTIONS This Installation Guide uses the following symbols to indicate important information Always observe the instructions indicated by these symbols N WARNING Instructions that if ignored could result in death or serious personal injury caused by incorrect handling or installation of the product These instructions must be observed for safe installation N CAUTION The instructions can not be provided for any other installation other than that of the Vigo brand The warranty will be voided if the following was not performed properly J IMPORTANT Maintenance and other important non personal injury and non material damage instructions or statements that should be observed It is highly advised to dry fit the unit prior to any installation INSTALLATION INSTRUCTIONS FOR SHOWER DOOR OWNER S MANUAL 8 Handle assembly 1pc 9 Side seal strip w out bump 1pc PLEASE READ INSTRUCTIONS BEFORE PROCEEDING 10 Door bottom seal strip 1pc 1pc extra 11 Door threshold 1pc VIGO ac EISE 12 Door side seal strip 1 1 Turning hinge base 1pc 13 y 1 5 8 4 2 Turning hinge base mirrored 1pc on 14 Phillips screw 1 5 8 6pc 3 Turning hinge 1pc 15 Phill 1 1 8 3 4
8. d VIGO dealer VIGO warrants the seal strip components of the Product to be free from defects in workmanship and materials under normal use and service for a period of one 1 year from the initial date of purchase by the owner or end user contractor or builder from VIGO or an authorized VIGO dealer Subject to the Warranty Service provision below any product reported to the authorized dealer or to VIGO as being defective within the warranty period will be repaired or replaced with a product of equal value at the option of VIGO This warranty extends to the original owner or end user and is not transferable to a subsequent owner Neither the distributor authorized VIGO dealer nor any other person has been authorized to make any affirmation representation or warranty other than those contained in this warranty Any affirmation representation or warranty other than those contained in this warranty shall not be enforceable against VIGO or any other person VIGO reserves the right to modify this warranty at any time it being understood that such modifications will not alter the warranty conditions applicable at the time of sale of the products in question Limitations This warranty shall not apply to instances of incorrect operating procedures breakages or damages caused by fault through improper installation carelessness abuse misuse misapplication improper maintenance or alteration of the Product as well as chemical or natural corro
9. e of the stall to provide a secure mounting to the door Apply a bead of silicone between the walls and base of the stall e For optimum performance you should install the shower door perfectly level on a level surface By not leveling the unit during construction the unit may leak causing possible water damage IMPORTANT THE CLEAR GLASS MODEL HAS A REVERSIBLE DOOR AND CAN BE INSTALLED TO THE RIGHT CONFIGURATION A OR LEFT SIDE CONFIGURATION B SEE CONFIGURATION DIAGRAMS ON PAGE 4 INSTALLATION INSTRUCTIONS Installer is responsible for determining attachment method Anchors are provided as one means of installation Recommended installation is into studs behind the wall This is the strongest means of installation PREPARATION STEPS TO FOLLOW BEFORE INSTALLATION 1 Remove the plastic layer from the base border if needed Do NOT remove the plastic layer off the plastic platform of the base or from the face of the hardware until installation is complete 2 Properly apply silicone to the wall and base joints J IMPORTANT e oprevent damage to the finish you should protect the shower cabin bottom with a cardboard protector before beginning the installation e Ensure that there is sufficient structural support behind the shower wall to hold the weight of the shower door If there is insufficient support then reinforce the shower walls with wooden studs prior to shower door installation SEE FIG 1 MODEL VG06042 J IMPORTANT
10. er length Note that there are screw holes on both sides of the threshold this makes the unit reversible Please make sure the threshold end with a screw hole that was not cut off during the sizing process should be always placed by the side of hinge base mirrored 2 2 Slide the right threshold clip 25 to the bottom corner of the side panel 18 Mark a hole on the floor for the mounting screw Drill a hole into the floor and insert plastic anchor 16 Replace the right threshold clip and screw it into the floor with 1 1 8 phillips screw 15 Applying silicone underneath 3 Slide the right end of the door threshold 11 into the right threshold clip that has been screwed to the floor Place the left threshold end cup 28 on the left end of the door threshold Then carefully align the door threshold and threshold end cup under the door panel The threshold end cup should be placed against the turning point of the hinge base mirrored Make sure the door threshold is in alignment with the side panel SEE FIG 10 AND 10 4 Remove the threshold end cup and mark a hole on the floor for the threshold screw Remove the door threshold and drill hole into the floor Insert plastic anchor 16 into the hole Replace the door threshold and screw into the floor with 1 1 8 phillips screws 15 Recover the threshold end cup VIEW WITH PART 25 4 REMOVED 11 Pk x SCREW HOLE TOP VIEW gt FIG 10A E
11. extents See suggestion of configuration below CONFIGURATION 1A CONFIGURATION 1B NN CONFIGURATION 2A CONFIGURATION 2B B B CONFIGURATION 3A B CONFIGURATION 3B B B CONFIGURATION 4A B B CONFIGURATION 4B FIG 1A GLASS CONFIGURATION DIAGRAM MODEL VG06042 WARNING e WE STRONGLY RECOMMEND THAT A LICENSED PROFESSIONAL INSTALL THIS STANDING SHOWER CABIN AND INCLUDE THE ASSISTANCE OF A SECOND PERSON TO INSTALL THE DOOR UNIT INSTALLATION OF THE SHOWER DOORS BY AN INEXPERIENCED PERSON MAY RESULT IN GLASS BREAKAGE AND CONSEQUENTLY CAUSE PERSONAL INJURY OR DEATH BEFORE STARTING Compare items on your invoice with what you have received Carefully review the Packing List on page 2 If any items are missing please call Vigo Industries at 1 866 591 7792 REQUIRED TOOLS Square and or Phillips 1 and 2 screwdriver Flat head screwdriver Electric drill 3 32 1 8 3 16 or 7 32 drill bit According to wall Level Measuring tape Non permanent pencil Clear silicone caulking Utility knife Hacksaw WARNING Handle fragile items with care to prevent personal injury or material damage Glass on panels and doors in tempered and must never be cut to prevent personal injury J IMPORTANT e Fiberglass or acrylic construction might not be sufficiently strong enough to support the shower door enclosure You should use the wood framing from behind the face edg
12. install the lower shelf glass 10 MODEL VG06042 G INSTALLING THE HANDLE ven h Unscrew the handle holders from the handle assembly 8 2 Place the handle to to position on the door Place plastic washers supplied on each side of the door SEE FIG 8 3 Tighten the handle nuts from inside the shower INSIDE HANDLE SY METAL WASHER E 9 CLEAR WASHER 59 METAL WASHER m SCREW Y WHITE TUBE 9 e OUTSIDE HANDLE GLASS SUPPORT THREADED SCREW FIG 8 H INSTALLING SEAL STRIPS 1 Install the door side seal strip 12 to the door when the door edge towards the wall is away from the turning hinge base 1 If maximum length of the shower enclosure is required and the door edge is within rubbing distance of the glass support install the side seal strip without bump 9 SEE FIG 9 2 Install the door bottom seal strip 10 onto the bottom of the door panel 3 Install the magnetic seal strips 19 onto the door panel and the side panel Note F shaped seal strip 23 may be installed to the door panel at this point if customers choose not to install the side panel due to space constraints threshold clip with screw hole 25 should not be installed in this case either 9 or 12 E r EN N 18 FIG 9 MODEL VG06042 11 l INSTALLING THE DOOR THRESHOLD 1 Measure the distance from side to side under the door and cut the threshold to the prop
13. lass sinks by an inexperienced person may result in glass breakage and consequently cause personal injury or death VIGO is not liable for personal injuries or deaths to any persons or for any direct special incidental or consequential damage loss of time loss of profits inconvenience incidental expenses labor or material charges or any other costs resulting from the use of the product or equipment or pertaining to the application of the present warranty or resulting from the removal or replacement of any product or element or part covered by this warranty EXCEPT AS OTHERWISE PROVIDED ABOVE VIGO MAKES NO WARRANTIES EXPRESSED OH IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE OR COMPLIANCE WITH ANY CODE In any case VIGO cannot be held liable for any amount over and above the purchase price paid for the Product by the owner end user contractor or builder Commercial Limitations In addition to the above conditions and limitations the warranty period for products installed for commercial applications or used in commercial ventures is one 1 year from the initial date of purchase by the owner end user contractor or builder from an authorized dealer VIGO is not responsible for loss of use or profit under any circumstances If the product is used as a display the warranty period begins when the product is placed on display This warranty gives the owner end user specific legal rights The owner end
14. onnecting the turning hinge base and the structural arm Screw the structural arm making sure it is firm and plum to the wall keeping the front fixed panel at a 90 angle with 1 5 8 phillips screws 14 and push screw covers into place SEE FIG 4A 1 2 TOLERANCE ADJUSTMENT MODEL VG06042 INSTALLING THE DOOR PANEL Insert the convex portion of the turning hinge mirrored 4 into the concave point of the turning hinge base mirrored 2 SEE FIG 5 One installer manually inserts the convex portion of the turning hinge 3 into the concave portion of the turning hinge base 1 and holds the position The hinges should be turned to a slightly open position The other installer lifts the door panel 6 and gently slides it into both turning hinges at the same time SEE FIG 5A otop the sliding of the door panel at the proper location based on the pre determined configuration or the specific site space requirements Tighten three screws supplied on both turning hinges from inside the shower respectively making sure the door panel is tightly secured by these two hinges and level FIG 5 FIG 5A MODEL VG06042 N INSTALLING THE SIDE PANEL Install the side seal strip 7 to the wall side of the side panel 18 Do not cut around the glass supports 29 SEE FIG 6 Screw in the glass support 29 with the hex key to the front fixed panel Be sure
15. sion accident fire flood an act of God or any other casualty Avoid abrasive cleaners steel wools and harsh chemicals as these will scratch damage and or dull the product and or finish and void this warranty The owner end user of the Product covered by the present warranty is entirely responsible for its proper installation and any applicable plumbing or electrical wiring VIGO neither installs nor supervises the installation nor hires a contractor for this purpose consequently VIGO cannot be held responsible for any default breakage or damages caused thereby or resulting thereof either directly or indirectly The owner end user must provide access to the components of the Product as described in the installation guide so that VIGO can execute the warranty specified herein If such access is not available all expenses to provide said access will be the responsibility of the owner end user This warranty does not apply to Products that have not been installed or operated in accordance with instructions supplied by VIGO and all applicable rules regulations and legislation pertaining to such installations This warranty does not apply unless the VIGO Product is installed by fully insured licensed professionals Vigo strongly recommenas that such licensed professionals have experience in the installation of bathroom and kitchen products Installation of certain products including without limitation glass products i e shower doors and g
16. to use washers on both sides of the panel and make sure the glass shelf holes are closer to the top of the panel Arrange the side panel in alignment with the door panel 6 Keep both panels perpendicular to the walls Mark holes on the wall for the mounting screws for the glass support Remove the side panel and drill holes into the wall Insert plastic anchors 17 into the holes Replace the side panel Screw into the wall with 1 5 8 hex screws 13 SEE FIG 6 SIDE sane _ FIG 6 ALIGNS WITH DOOR PANEL INSTALLING THE GLASS SHELF Unscrew the shelf glass holder cap 22 insert threaded portion of shelf holder into the hole of the side glass panel 18 and then screw the holder cap back The upper glass shelf sh ould be installed first SEE FIG 7 Slide the glass shelf into the holder and tighten the screw supplied from underneath part 22 to firmly hold the glass shelf in place Use a level to make sure that glass shelf is level against the wall Mark holes on the wall for the mounting screws for the glass shelf holder to wall 21 Loosen the screw of the shelf glass holder to glass from underneath and remove the shelf glass from the side panel Drill holes into the wall Insert plastic anchors 16 into the holes Install two shelf glass holders to wall with 1 5 8 phillips screws 14 Slide the shelf glass into the three shelf glass holders and tighten the screws from underneath Repart 1 6 to
17. w they can be easily removed with a liquid automobile polish IMPORTANT e Do NOT use abrasive cleaners scrapers metal brushes or any item products that would scratch and or dull surface e Do NOT allow surface to come in contact with acetone nail polish remover dry cleaning solution lacquer thinner gasoline or any other similar product OO UJ 13 MODEL VG06042 V606042B RIGHT DOOR MODEL VG06042 VG06042B LEFT DOOR 14 VIGO VIGO INDUSTRIES LL C VIGO SHOWER ENCLOSURE LIMITED LIFETIME WARRANTY EFFECTIVE JANUARY 1 2010 VIGO offers the following limited warranty on each of its Shower Enclosure products the Product and the components thereof This warranty extends only to the original owner or end user for personal household use For commercial uses additional limitations apply VIGO warrants the structural glass component of the Product to be free from defects in workmanship and materials under normal use and service for the period commencing from the initial date of purchase by the owner or end user contractor or builder from VIGO or an authorized VIGO dealer through the lifetime of the original owner or end user VIGO warrants the hardware components of the Product to be free from defects in workmanship and materials under normal use and service for a period of two 2 years from the initial date of purchase by the owner or end user contractor or builder from VIGO or an authorize

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書    Kenroy Home 32438BLU Instructions / Assembly  lire - HapsatouSy  Manual del usuario  Versión 1.1.1 de Actualización de Firmware para EOS 40D  Qualidade - Dispositivo Móvel  Arat NS1376 holder    PICkit 1 FLASH Starter Kit User's Guide  

Copyright © All rights reserved.
Failed to retrieve file