1. Follow instructions accurately to make certain the Towel Warmer is properly attached to the wall FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS 3 Do not use an abrasive cleaner on the Towel Warmer A mild detergent will clean and restore most units to their original beauty 4 TO ENSURE FULL EFFICIENCY OF YOUR TOWEL WARMER PLEASE FOLLOW ALL THE INSTRUCTIONS CAREFULLY OBSERVING THE CAUTION NOTATIONS FOR EACH STEP Inlet water temperature should be between 120 F and 158 F DO NOT exceed this limit A burn hazard may result N o1 DO NOT alter or modify any Mr Steam products Doing so may result in an inoperable or hazardous installation and will void the warranty Optional Brackets ZA cS Screws Additional towel warmer support brackets are available for installations where plumbing does not provide a rigid support to secure the towel warmer to the wall Bracket Part Numbers and Optional Finishes Polished Chrome 103959PC Polished Nickel 103959BN Towel Warmer Installation Parts Figure 1 Escutcheons Brass Inserts QD QO SO ZZ OG YA SY Washers Set Screws Mounting Backet Escutcheons Eccentric Coupling mr steam Hydronic Towel Warmers Installation and Operating Instructions STEP 1 PRE INSTALLATION A Select Installation Site Make certain there is ample clear ance on both sides and back of the Towel Warmer NOTE This unit is supplied with the proper hardware for installation Be sure wa
2. vane Towel Warmer AVAILABLE DIGITAL PROGRAMMABLE TIMER Installation To The Installer 1 Read the operating instructions provided with the timer 5 Mount timer into wall box using supplied screws 2 Disconnect power supply prior to installation to prevent 6 If timer does not operate check that the timer s black electrical shock wire is connected to hot line and not the load If necessary reverse connec 3 Damage to the contacts caused by short circuiting will tions to red and black wires void the warranty 4 Wire in accordance with National Electrical and Local 7 When the indicator light on the towel warmer is illumi Code requirements Be sure all connections are secure nated the towel warmer is energized Double check all twist on wire connectors AVAILABLE DECORATIVE FACEPLATE FOR TIMER Polished Chrome 103872D PC Polished Nickel 103872D PN Brushed Nickel 103872D BN Oil Rubbed Bronze 103872D ORB mr steam Hydronic Towel Warmers Installation and Operating Instructions HYDRONIC MODEL H542 Suitable only for closed loop non potable hot water systems Tighten Towel Warmer unions only Do not turn valves as leaking may result Do not use with water over 158 degrees F 70 C Do not use with steam Using with steam or water over 158 degrees F or 20 psig may result in scalding or hazardous conditions 1 Read this entire instruction manual thoroughly before beginning installation and save these instructions
3. THAT ELECTRICITY IS TURNED OFF AT THE MAIN PANEL BEFORE ANY WIRING IS DONE Nona The towel warmer is an electronically operated device It must be installed by a licensed electrician in accordance with local code and the National Electric Code NEC JAX CAUTION Install a wall switch or timer to turn the towel warmer on and off NOTE When the towel warmer is energized the indicator light on the towel warmer will illuminate DO NOT alter or modify any Mr Steam products Doing so may result in an inoperable or hazardous installation and will void the warranty 1 Assemble the BX cable connector to the wiring flange as 2 Secure wiring flange to the wall with screws provided shown Use longer screws as required by construction conditions BX Cable or greenfield BX Connector Lock Nut NOTE NM non metallic cable if permitted by National and Local Codes may be used instead of BX cable 4 Slide the wiring box onto the wiring flange and tighten the set screw firmly Secure the upper threaded flanges and lower bracket with screws provided 3 Connect wiring per instructions page 8 i Wiring Box Wiring Box Wirina Ray Sat Srrowle NOTE The Towel Warmer wires are color coded BLACK for LINE WHITE for NEUTRAL GREEN YELLOW for EQUIPMENT GROUND If a single gang electric box has been roughed in see page 3 for instructions NIE Install Towel Warmers in upright position only Locate with swit
4. cleaning powders metal polish or chlorine based cleaners be used on any part of this product IMPORTANT This appliance is intended for towels washed in water Fabrics that contain soap or deter gent residue may show what appears to be scorch marks However this is simply the discoloration of the residue The Towel Warmer unit does not reach suffi cient temperature to scorch fabric We are not respon sible for discoloring or damage of any fabrics This picture shows the recom mended method of draping a towel on a towel warmer Ensure that as much as possible of the towel s surface is touching the towel warmer to ensure fast even warming of the towel Electric Towel Warmers Installation and Operating Instructions INSTALLER READ THIS ENTIRE INSTRUCTION MANUAL THOROUGHLY BEFORE BEGINNING INSTALLATION LEAVE THESE INSTRUCTIONS WITH HOMEOWNER BE CERTAIN ELECTRICITY IS SHUT OFF AT MAIN PANEL BEFORE WIRING OR SERVICING YOUR TOWEL WARMER Follow instructions to make certain your Towel Warmer is properly attached to the wall FAILURE TO FOLLOW THESE STEPS COULD RESULT IN HAZARDOUS CONDITIONS To avoid possible fire hazard the Towel Warmer must remain in its intended position MOUNT THIS UNIT ONLY AS SHOWN IN THESE INSTRUCTIONS DO NOT alter or modify any Mr Steam products Doing so may result in an inoperable or hazardous installation and will void the warranty 1 Install in accordance with National and local
5. codes Shower Tub Zone 2 Do not locate in shower i l l l stall or near shower spray l Do not locate the towel warmer within the shower tub zone 3 Do not locate within the shower or tub zone 4 All models are to be pro tected by dedicated and suitably rated GFCI circuit breaker or equal For illustrative purposes only TO ENSURE CORRECT OPERATION OF YOUR TOWEL WARMER PLEASE FOLLOW ALL THE INSTRUCTIONS CAREFULLY OBSERVING THE CAUTION NOTATIONS FOR EACH STEP Inspect Towel Warmer Unpack the Towel Warmer carefully to avoid any damage or loss of any part When opening the box be sure that the parts are not accidentally discarded Towel Warmers are shipped in specially designed shipping cartons The entire surface of the Towel Warmer is hand wrapped to protect the finish It is your responsibility to immediately inspect for any damage TOWEL WARMER SPECIFICATIONS Dimensions inches Model No WxHxD Amps _ Volts Phase Weight Ibs W500 22 5x25x5 0 83 120 1 20 W542 23 75 x 26x5 25 1 25 120 1 25 W634 19 5x27 5x7 25 1 67 120 1 25 mr steam Electric Towel Warmers Installation and Operating Instructions WALL PREPARATION NN S4 DO NOT mount the Towel Warmer without providing structurally secure headers as shown Finished wall surface e DO NOT mount the Towel Warmer directly to sheet rock or any other non structural surface e Use longer fasteners as required if the
6. wall 7 Gently slide the towel warmer onto the brass inserts as shown and mark the location for the wiring flange 8 Remove the towel warmer and secure the flange to the wall per the instructions on page 7 9 Before securing the towel warmer to the wall put an escutcheon on each of the 4 brackets The open end of the escutcheon should face the wall as shown 10 Secure the towel warmer to the brass inserts using the set screws provided When the towel warmer is secured to the wall slide the escutcheons against the wall to hide the mounting point If a single gang electric box has been roughed in See page 3 for instructions Install Towel Warmers in upright position only Locate with indicator light on bottom as shown Failure to install properly may result in a hazardous condition Electric Towel Warmers Installation and Operating Instructions IMPORTANT DO NOT LOOSEN SCREWS ON TOP OR BOTTOM BRACKETS LOOSENING SCREWS WILL CAUSE INTERNAL LIQUID TO ESCAPE AND CAUSE PRODUCT DAMAGE Pate Insert Bracket Escutcheons Wiring Box Flange Wiring Box Escutcheon Wirin Box 3 Finished surface of wall Brass Insert Screw Sliding Escutcheon 5 Set Screw Towel Warmer mr steam Electric Towel Warmers Installation and Operating Instructions MODELS W500 TO PREVENT SHOCK HAZARD BE CERTAIN THAT ELECTRICITY IS TURNED OFF AT THE MAIN PANEL BEFORE ZA ANY WIRING IS DONE Upper T
7. AL 4 Installation Operation and Maintenance Manual Fifth Avenue Collection Electric amp Hydronic Towel Warmers Models W500 W542 H542 W634 mr steam Feel Good Inc Table of Contents Electric Models General Information amp Specifications 2 Serial No So Wall Preparation Mounting Installation Models 542 634 Model 500 Electrical Connections Digital Programmable Timer Models W500 W542 H542 W634 Hydronic Model General Information Pre Installation amp Wall Pre Plumbing Preparation Hook up and Installation INS SS re L7 as AY W Q lt i a ON YP Dy Operation amp Maintenance IMPORTANT NOTE As you follow these instructions you will notice warning and caution symbols PRIO BOSZ REV This blocked information is important for the safe and efficient installation and operation of this Towel Warmer These are types of potential hazards that may occur during this installation and operation states a hazard NESIN signals a situation IMPORTANT NOTE This highlights may cause serious injury or death if where minor injury or product damage information that is especially relevant precautions are not followed may occur if you do not follow instructions to a problem free installation LISTED US mr steam HOMEOWNER THANK YOU for selecting Mr Steam Towel Warmer the perfect addition to bathrooms family spas and exercise rooms within your home Our products have long be
8. apter to be flush be with finished face of wall STEP 3 INSTALLATION A Mounting 1 The Mr Steam Towel Warmer has been designed with integral mounting brackets These will facilitate a permanent and secure mounting of the Towel Warmer to the wall using the screws provided 2 Locate the brass inserts according to the following chart Vertical Distance from Inlet Outlet Pipe centerline H542 6 7 16 All inlet outlet pipes are 18 1 2 apart 3 Slide a bracket escutcheon with the O ring facing the towel warmer on each of the mounting brackets 4 Slide the towel warmer on the brass inserts and tighten the set screws on both brackets Slide the escutcheons against the wall to hide the joint 5 The recommended location for optional lower brackets is on the bottom rung of the Towel Warmer a sufficient header should be provided for these brackets 11 mr steam Hydronic Towel Warmers Installation and Operating Instructions STEP 3 INSTALLATION cont B Valve Installation 1 Place a washer between the threaded portion of the valve and the Towel Warmer union carefully tighten the union to secure the valve to the Towel Warmer 2 Slide the escutcheon onto the valve over the valve union 3 After the plumbing has been prepared as described ace a washer between the valve union and coupling arefully tighten the union to connect the valve to the plumbing 4 Slide the escutcheon over the valve
9. ch on bottom as shown Failure to install properly may result in overheating and a hazardous condition 7 mr steam Electric Towel Warmers Installation and Operating Instructions ELECTRICAL SPECIFICATIONS Field Wired Models W500 W542 W634 Electrical Connections TO PREVENT SHOCK HAZARD BE CERTAIN THAT ELECTRICITY IS TURNED OFF AT THE MAIN PANEL BEFORE ANY WIRING IS DONE All wiring must conform to National Electrical and Local Codes GENERAL The Towel Warmer requires 120VAC 60 Hz power supply Specific amperage needed is listed in the Towel Warmer Specifications Chart on page 2 of pur 103852 A Electrical connections should be made as prescribed by the National Electric and Local Codes The unit should be field wired using 14 AWG min 90 C rated copper wire All models are to be protected by a separate 15 amp circuit breaker or equal B Make connections between Towel Warmer and house wiring using approved connections to comply with National Electrical Local Codes LINE black NEUTRAL white and GROUND C Install the Towel Warmer according to the specific instructions for each model TO PREVENT SHOCK HAZARD NO BARE WIRE OR WIRE STRANDS SHOULD BE VISIBLE AFTER MAKING CONNECTIONS om a Field Installed Wall Switch or Mr Steam Digital Programmable Timer par ara PN 103588DIG l Thermal Fuse L L DOO mo N a a Thermostat Element GRND GRD _ _ T Heating Element Wiring Box l g g
10. en a standard for quality and comfort and we are sure that you will experience continued enjoyment from the Towel Warmer you have purchased by following these simple instructions TOWEL WARMERS ARE HOT The Towel Warmer is an electrical heating appliance intended only for indoor residential applications and as such should be installed and used with certain precautions for your safety 1 INSTALLATION PROCEDURES FOR PERMANENTLY WIRED WALL MOUNTED UNITS MUST BE ACCOMPLISHED BY QUALIFIED PERSONNEL IN STRICT ACCORD WITH APPLICABLE NATIONAL AND LOCAL BUILDING AND ELECTRICAL CODES 2 DO NOT place TOWEL WARMER units inside a shower sauna or steam room enclosure or any other wet loca tion or with elevated temperatures 3 CAUTION is advised when Towel Warmer is accessible to children 4 For the ultimate ease in use a dedicated wall switch or timer can be used to control the TOWEL WARMER unit Contact Mr Steam for an in wall 24 hour 7 day timer PN W 103588 NOTE All switches and control devices must be installed on the load black side of the Towel Warmer circuit in compliance with the National Electric Code and Local Codes see page 8 for installa tion instructions IMPORTANT The finish of your Towel Warmer can be protected and maintained by an occasional wiping with a soft non abrasive damp cloth and lightly polished thereafter with a soft dry cloth when the Towel Warmer is cold Under no circumstances should abrasive
11. finished wall surface prevents adequate mounting with the screws provided e Provide a clearance hole in the lower header as required to route field wiring to the Towel Warmer wiring box Sg If a single gang electric box has been roughed in install cover plate PN103877 See part numbers below for decora tive finish information DO NOT install the Towel Warmer y without these instructions Cover Plate Part Numbers amp Decorative Finishes Polished Chrome 103877PC Polished Brass 103877PB Polished Nickel 103877PN Pewter 103877P wig 5s Satin Nickel 103877SN i Polished Gold 103877PG Satin Gold 103877SG Antique Brass 103877AB Oil Rubbed Bronze 103877ORB MOUNTING DIMENSIONS inches MODEL X min Y Z min HEADER HEADER HEADER SIZE HORIZONTAL LENGTH VERTICAL LENGTH wo s 2 e Ds wall surface gt IMPORTANT NOTE Towel Warmers may have small dimensional variations and must be measured prior to installation For Technical Service Assistance East Coast Tel 1 800 767 8326 West Coast Tel 1 800 727 8326 For illustrative purposes only mr steam Electric Towel Warmers Installation and Operating Instructions MOUNTING MOUNTING DIMENSIONS inches MODEL A B Cc W 634 2 14 6 Install Towel Warmers in upright position only Locate with indicator light on bottom as shown Failure to install properly may result in overheating and a haz ardous co
12. hreaded Flange Upper Support Bracket Box Contents e Towel Warmer o e 6 Screws Up e 1 Upper Threaded Flange e 1 Lower Wiring Flange e 1 Small Allen Key Level e 1 Large Allen Key e Instruction amp Operation Manual e Warranty 1 Remove the Towel Warmer and parts from the packing materials 2 Rotate the upper bracket as shown IMPORTANT DO NOT LOOSEN SCREWS TO SWIVEL BRACKETS LOOSENING SCREWS WILL CAUSE INTERNAL Wiring LIQUID TO ESCAPE AND CAUSE PRODUCT DAMAGE Box 3 Spin on upper threaded flange as shown 4 Using the smaller allen key provided loosen the wiring box set screw DO NOT remove the wiring box 5 Rotate the wiring box as shown Tighten the set screw firmly to prevent the wiring box from rotating 6 Place the Towel Warmer in the desired location and mark the location of the upper threaded flange and wiring box Use a level to insure proper alignment NOTE the Towel Warmer swing range 7 Mount the lower wiring box per instructions on page 7 If a single gang electric box has been roughed in then see page 3 for installation instructions Install Towel Warmers in upright position only Locate with indicator light on bottom as shown Failure to install properly may result in overheating and a hazardous condition mr steam Electric Towel Warmers Installation and Operating Instructions ELECTRICAL CONNECTIONS Models W500 W542 W634 TO PREVENT SHOCK HAZARD BE CERTAIN
13. htly polished thereafter with a soft dry cloth Under no circumstances should abrasive cleaning pow ders or metal polish be used on any part of a chrome or gold plated Towel Warmer WARRANTY To view or download the Mr Steam Towel Warmer Warranty and register your product go to blog mrsteam com wr ee Ee og m mr S te am Sussman Automatic Corporation hello mrsteam com www mrsteam com 43 20 34th Street Long Island City NY 11101 TeL 1 800 76 STEAM Fax 718 472 3256 9410 S La Cienega Blvd Inglewood CA 90301 Tet 1 800 72 STEAM Fax 310 216 2944 2013 Sussman Automatic Corporation Mr Steam and des AromaFlo AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy Digital 1 Express Steam From Bathroom to Spa iGenie iSizing iSteam iSteam Plus MusicTherapy Spa Package Steam Genie Steam Home SteamTherapy Sussman Valet Package Virtual Spa System Voice Genie and Voice Wizard are registered trademarks of Sussman Automatic Corporation AudioWizard A Lifetime of Pleasure Home Wizard iButler iSteamTV iTempo iTempo Plus MySteam Smart Sizing Steam in a Box SteamStart SteamStop and The Intelligent Steambath are trademarks of Sussman Automatic Corporation PUR 103852 1 15
14. ll construction is appropriate for hang ing see Step 3A pg 11 B Before beginning the installation of any Mr Steam Hydronic Towel Warmer please note the following Maximum operating temperature should not exceed 158 F Any working water temperature higher than 158 F could create a potential burn hazard NOTE A closed loop non potable hot water system is rec ommended Consult an authorized hot water system installer for hot water system types STEP 2 INSPECT THE TOWEL WARMER A Unpack the Mr Steam Towel Warmer carefully to avoid any damage or loss of any part When opening the box and unwrapping the Towel Warmer be sure that parts are not accidentally discarded see illustration Fig 1 pg 9 B Mr Steam Hydronic Towel Warmers are shipped in spe cially designed shipping cartons The entire surface of the Towel Warmer is hand wrapped to protect the finish Check the for any sign of damage HOT WATER TOWEL WARMERS Dimensions inches CH wT D BTU weight ths 2976 21 5 500 20 tAt 158 F without water N m7 F Roo cc O Q be Q I gt Q H pe Q ie ie mil w D WALL PREPARATION e DO NOT mount the Towel Warmer without providing structurally secure headers as shown e DO NOT mount the Towel Warmer directly to sheet rock or any other non structural surface e Use longer fasteners as required if the finished wall su
15. ndition IMPORTANT NOTE Towel Warmers may have small dimensional variations and must be measured 1 prior to installation F Wiring Box This End Up oe Wiring Box mr steam MODELS W542 amp W634 Box Contents e Towel Warmer e 4 Bracket Escutcheons e 3 Small Screws e 1 Wire Box Escutcheon 1 e 4 Large Screw e 4 Bracket Set Screws e 1 Wiring Box Set Screw 4 Brass Inserts e 1 Wire Box Flange e 1 Allen Key e Warranty e Instruction amp Operation Manual 1 Remove Towel Warmer and parts from the packing materials 2 Rotate the two upper and two lower brackets into position as shown IMPORTANT DO NOT LOOSEN SCREWS TO SWIVEL BRACKETS LOOSENING SCREWS WILL CAUSE INTERNAL LIQUID TO ESCAPE AND CAUSE PRODUCT DAMAGE 3 Using the allen key provided loosen the wiring box set screw DO NOT remove the wiring box 4 Rotate the wiring box as shown Tighten the set screw firmly to prevent the wiring box from rotating NOTE The wiring box and brackets on model W542 can be rotated in either direction to result in a right or left handed wiring box 5 Measure the towel warmer and mark the location where the brass inserts will be mounted to hang the towel warmer Before securing the towel warmer to the wall check to ensure the mounting points are level 6 Using the screws provided secure the brass inserts to the
16. rface prevents adequate mounting with the screws provided e The recommended location for the optional lower brackets is on the bottom most rung of the Towel Warmer as shown MOUNTING DIMENSIONS inches MODEL Inlet outlet pipe to be 18 2 apart for all models IMPORTANT NOTE Towel Warmers may have small dimen sional variations and must be measured prior to installation For Technical Service Assistance East Coast Tel 1 800 767 8326 West Coast Tel 1 800 727 8326 L _Inlet Outlet Pipe ___ Center to Center 22 Min Header Length Set Screw Towel Warmer 10 mr steam Hydronic Towel Warmers Installation and Operating Instructions PLUMBING PREPARATION e If the eccentric coupling is used a female 1 2 NPT coupling or thread to sweat adapter should be flush with the finished face of the wall e If the eccentric coupling is not used a male 3 4 NPT pipe coupling or thread to sweat adapter shall be 1 2 an inch beyond the finished face of the wall 2 nh rsh Yi E oy U U HYDRONIC HOOK UP Hydronic Towel Warmer Supplied with Field Supplied CS Towel Warmer Field Plumbing Eccentric O coupling optional Taal Escutcheon D Warmer Union S idee coupling Washer or similar Valve S 1 2 NPT Coupling Z or thread to sweat H ad
17. union to cover the inlet and outlet plumbing IMPORTANT There are two valves which come with Mr Steam Hydronic Towel Warmers One valve should always be left open the other valve can be opened or closed These valves seal only in the fully open turn valve handle counter clockwise or full closed turn valve handle clockwise position Using the valve to throttle the water flow will result in a leak at the valve stem aT 5 When all connections are complete vent the unit using the bleed valve as shown DO NOT TURN THE VALVE BODY TURN THE UNION ONLY TURNING THE VALVE MAY RESULT IN LEAKS 6 Check all connections for leaks DO NOT open the bleed screw when the unit is pressurized as hot water may present a scalding hazard see Step 6 in installation Bleed screw location for models H542 Make sure the bleed screw is securely tightened and not leaking VALVE INSTALLATION L dina be afad Union Escutcheon 1 2 Pipe WARNING field supplied Turn this union only i to assemble the valve to the upright tube Valve Washer Optional eccentric coupling supplied VL Do not spin this valve onto the upright tube as this may cause upright joints to loosen and leak STEP 4 OPERATION amp MAINTENANCE CLEANING The finish of your Mr Steam Towel Warmer can be protected and maintained by an occasional wiping with a dampened cloth and lig