1. Mounting Bracket Screw z Mounting Bolt gt yan Fi SS BOX CONTENTS e Towel Warmer 4 Mounting screws e 4 Mounting brackets e 4 Mounting bracket knurled thumb screw e 4 Mounting bolts JUIN Plug into a grounded 3 prong outlet DO NOT remove ground prong DO NOT use an adapter DO NOT use an extension cord 1 Remove Towel Warmer and parts from the packing materials 2 An outlet should be provided per National and local electrical Codes such that when plugged in the cord is not stretched pinched or routed in such a manner as to cause a hazard 3 Locate the mounting brackets on the wall by measuring the mounting holes on the towel warmer 4 Using the screws provided secure the brackets to the wall 5 Insert the sleeves into the extensions Using the mounting bolts secure the extensions and sleeves to the 4 threaded holes on the towel warmer 6 Slide the towel warmer onto the mounting brackets and secure in place using the knurled thumb screws provided with the cord connection kit NIGSRIN Towel Warmers in upright position only Locate with cord on bottom as shown Failure to install properly may result in a hazardous condition See page 4 JINN Do not fasten power supply cord to wall surface yrs Towel Warmer e 4 Sleeves e 4 Extensions e Allen wrench e Instructions e Warranty Mounting Bracket Mounting Screw Mounting Bolt Sleeve Extension Knurled Thumb Sc
2. are based on the latest product information available at the time of publication Sussman Automatic Corporation reserves the right to make changes at any time without notice mr steam Sussman Automatic Corporation hello mrsteam com www mrsteam com 43 20 34th Street Long Island City NY 11101 1 800 76 STEAM Fax 718 472 3256 9410 S La Cienega Blvd Inglewood CA 90301 1 800 72 STEAM Fax 310 216 2944 W336 W348 W336CORD W348CORD c US LISTED 2013 Sussman Automatic Corporation Mr Steam and des AromaFlo AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy Digital 1 Express Steam iGenie Sizing iSteam MusicTherapy Spa Package Steam Genie Steam on Demand Steam Home SteamTherapy Sussman Valet Package Virtual Spa System Voice Genie and Voice Wizard are registered trademarks of Sussman Automatic Corporation AudioWizard Home Wizard iButler iSteamTV Tempo iTempo Plus MySteam Smart Sizing Steam in a Box SteamStart SteamStop The Intelligent Steambath are trademarks of Sussman Automatic Corporation PUR 100559 REV 11 13 mr steam HOMEOWNER THANK YOU for selecting Mr Steam Towel Warmer the per fect addition to bathrooms family spas and exercise rooms within your home Our products have been a standard for quality and comfort and we are sure that you will experience continued enjoyment from the Towel Warmer you have pur chased by following these instructions T
3. required if the finished wall surface prevents adequate mounting with the screws provided e Provide a clearance hole in the lower header as required to route field wiring to the Towel Warmer wiring box not applicable for cord connected models IMPORTANT NOTE See electrical rough in instruc tions on page 6 IMPORTANT NOTE Towel Warmers may have small dimensional variations and must be measured prior to installation Do not use dimensions to determine location of mounting holes MOUNTING DIMENSIONS inches Hard Wired amp Cord Connected X min Y Z min Header horizontal length Header vertical length Header size 19 o 9 o W336 25 hs 2x6 MOUNTING DIMENSIONS MOUNTING DIMENSIONS inches Hard Wired amp Cord Connected A B 18 16 176 NOTE C dimension is not applicable for cord con nected models IMPORTANT NOTE Towel Warmers may have small dimensional variations and must be measured prior to installation Do not use dimensions to determine location of mounting holes Installation Operation amp Maintenance Instructions Finished wall surface Towel Warmer For Technical Service Assistance East Coast Tel 1 800 767 8326 West Coast Tel 1 800 727 8326 mr steam INSTALLATION W328 W336 W348 TO PREVENT SHOCK HAZARD THE ELECTRICITY MUST BE TURNED OFF AT THE MAIN PANEL BEFORE ANY WIR
4. 4A Jo N Installation Operation amp Maintenance Manual Series 300 Electric Towel Warmers mr steam Feel Good Inc Series 300 Electric Towel Warmers Models W328 W328CORD F328 W336 W336CORD W348 W348CORD Model Serial TABLE OF CONTENTS General Information cccccccccecseseseeseeees 3 Specifications Wall Preparation Mounting Dimensions ccceeeeeeees 4 Installation W328 W336 W348 5 Electrical Connections 6 Optional Programmable Timer 7 W328 7 Installation F328 ccce Installation Cord Models cccccccceeees 8 JAA WARNING The towel warmer is an electric device It must be installed by a licensed electrician in accordance with the National Electrical Code NEC and local code W328CORD IMPORTANT NOTE As you follow these instructions you will notice warning and caution symbols This blocked information is important for the safe and efficient installation and operation of this Towel Warmer These are types of potential hazards that may occur during this installation and operation states a hazard may cause serious injury or death if precautions are not followed signals a situation where minor injury or product damage may occur if you do not follow instructions F328 IMPORTANT NOTE This highlights infor mation that is especially relevant to a prob lem free installation All information in these instructions
5. ING IS DONE IMPORTANT NOTE See electrical rough in instructions on page 6 Install Towel Warmers in upright position only Locate with wiring box on bottom as shown Failure to install properly may result in a hazardous condition See page 4 Allen Wrench E Wiring Box 1 Remove Towel Warmer and parts from the packing materials 2 Using the allen key provided loosen the wiring box set screw DO NOT remove the wiring box 3 Gently rotate the wiring box Installation Operation amp Maintenance Instructions BOX CONTENTS e Towel Warmer e 4 Mounting Screws e 3 Wiring Box Mounting Screws e 2 Wiring Box Set Screws e 4 Mounting Brackets e 4 Mounting bracket Set Screw NOTE Cord connected models use 4 knurled thumb screws e 4 Mounting bolts 4 Sleeves e 4 Extensions e Wiring box escutcheon e 2 Allen wrenches e Instructions e Warranty 7 Slide the towel warmer onto the mounting brackets Mark the location for the wiring box escutcheon 8 Remove the towel warmer and secure the escutcheon to the wall per the instructions on page 6 Wiring Box Escutcheon P Wiring Box Mounting Screws as shown Tighten the set screw firmly to prevent the wiring box from rotating 9 Slide the towel warmer onto the mounting brackets Secure the towel warmer in place using the mounting bracket
6. OWEL WARMERS ARE HOT The Towel Warmer is an electrical heating appliance intended only for indoor residential applications and as such should be installed and used with certain precautions for your safety 1 INSTALLATION PROCEDURES FOR WALL MOUNTED UNITS MUST BE ACCOMPLISHED BY QUALIFIED PERSON NEL IN STRICT ACCORD WITH APPLICABLE NATIONAL AND LOCAL BUILDING AND ELECTRICAL CODES 2 DO NOT place TOWEL WARMER units inside a shower sauna or steam room enclosure or any other wet location or with elevated temperature because the towel warmer may be an electrocution hazard 3 CAUTION is advised when a Towel Warmer is accessible to children because the towel warmer is hot 4 A dedicated wall switch or timer should be used to control the TOWEL WARMER unit Contact Mr Steam for an in wall 24 hour 7 day timer PN W 103588DIG Note All switches and control devices must be installed on the load black side of the Towel Warmer circuit in compliance with the National Electrical Code NEC and local code see page 6 for installation instructions IMPORTANT The finish of your Towel Warmer can be pro tected and maintained by an occasional wiping with a soft non abrasive damp cloth and lightly polished thereafter with a soft dry cloth when the Towel Warmer is cold Under no cir cumstances should abrasive cleaning powders metal polish or chlorine based cleaners be used on any part of this product IMPORTANT This appliance is for wa
7. ace may continue to be hot for a period of time after it has been turned off AVAILABLE DECORATIVE FACE PLATES FOR TIMER Brushed Stainless Steel 103872D SB Polished Stainless Steel 103872D SP 3 Damage to the contacts caused by short circuiting will void the warranty 4 Wire in accordance with National Electrical and Local Code requirements Be sure all connections are secure Double check all twist on wire connectors 5 Mount timer into a single gang wall box using supplied screws 6 If timer does not operate check that the timer s black wire is connected to hot line and not the load If necessary reverse connections to red and black wires 7 When the indicator light on the towel warmer is illuminated the towel warmer is energized INSTALLATION MODEL F328 BOX CONTENTS e Towel Warmer with 6 Grounding Type Power Cord e 2 Legs e 2 Leg Screws e 1 Large Allen Key e 2 Spacers e Instruction amp Operation Manual e Warranty 1 With the unit unplugged assemble the tubular legs to the bottom of the Towel Warmer as shown 2 DO NOT OVERTIGHTEN Ay CAUTION Locate F328 on a flat hard sur face Failure to do so may result in an unstable installation resulting in a hazardous condition IMPORTANT DO NOT OVERTIGHTEN L Towel Warmer SS Allen Wrench mr ste am Installation Operation amp Maintenance Instructions p INSTALLATION W328CORD W336CORD W348CORD Mounting a
8. eating and a hazardous condition All wiring must conform to National Electrical Code NEC and local code DO NOT alter or modify any Mr Steam products Doing so may result in an inoperable or hazardous installation and will void the warranty Installation Operation amp Maintenance Instructions 1 Assemble the BX cable connector to the wiring box erie escutcheon as shown Wiring Box ag Escutcheon NOTE NM non metallic cable if permitted by National and ore eae Local Codes may be used instead of BX cable D Z 2 Secure wiring box ss escutcheon to the wall with screws provided Use longer screws as required by con struction conditions 3 Connect wiring per instructions Wires from wiring box _ Wiring Box 4 Slide the wiring box into the Bstuteheon Ps wiring box escutcheon and tighten the set screw firmly Secure the upper and lower brackets per the instructions on page 5 Wiring Box INSTRUCTIONS FOR INSTALLING A 300 SERIES TOWEL WARMER WITH A JUNCTION BOX A wall plate is required to complete this installation Available wall plates Polished Chrome 104093PC Oil Rubbed Bronze 104093ORB White 104093WH 2 Secure the assembly to the junction box using the screws pro vided with the wall plate 1 Assemble the bushing to the wall plate and wiring box escutcheon as shown me Wiring Box Ns Wiring Box F Esc
9. l warmer within the shower tub zone No w For illustrative purposes only the shower or tub zone See illustration 4 All models are to be protected by dedicated and suitably rated GFCI circuit breaker or equal TO ENSURE CORRECT OPERATION OF YOUR TOWEL WARMER PLEASE FOLLOW ALL INSTRUCTIONS CAREFULLY OBSERVING THE CAUTION and WARNING NOTATIONS FOR EACH STEP Inspect Towel Warmer Unpack the Towel Warmer carefully to avoid any damage or loss of any part When opening the box be sure that the parts are not accidentally discarded Towel Warmers are shipped in specially designed shipping cartons The entire surface of the Towel Warmer is hand wrapped to protect the finish It is your responsi bility to immediately inspect for any damage TOWEL WARMER SPECIFICATIONS Volts Phase Weight Ibs Model Dimensions inches Amps WxHxD W328 20x31 x4 0 82 120 1 10 F328 19 x 34 x 11 0 82 120 1 10 W336 20x 38 4 x 4 1 11 120 1 14 W348 20x 49 x 4 1 40 120 1 18 NOTE Dimensions are approximate NOTE Hard wired and cord connected models have the same dimensions amps and weight Cord connected models include an integral 6 foot power cord mr steam WALL PREPARATION e DO NOT mount the Towel Warmer without providing structurally secure upper and lower headers as shown DO NOT mount the Towel Warmer directly to sheet rock or any other non structural surface e Use longer fasteners as
10. rew USING MR STEAM ESSENTIAL OILS Enjoy AromaSteam essential oils by placing one or two drops of oil into AromaSteam 10ml bottle your 300 series towel warmer aroma well as shown in the illustration with integrated dropper Only use Mr Steam AromaSteam essential oils os JAA WARNING Use essential oils with caution Essential oils are for external use only Keep out of reach of children Essential oils are highly concentrated and are potent substances and should not be applied directly to the skin as they can be irritants Use essential oils with caution Ay CAUTION Start with one drop to gauge strength and suitability ANJAWI Some people may find that the aroma makes them dizzy and the user should turn off the towel warmer and exit the room IMMEDIATELY If skin irritation occurs stop using the oils immediately Remove any excess oil by washing in mild soap and water If ingested rinse mouth with water T Administer water or milk to dilute Contact a physician immediately ARAIAN Use care not to allow oil to contact towels Tightly close oil bottles when storing oils Keep oil bottles away from sources of ignition 8
11. rming towels only DO NOT use this appliance to dry wet towels IMPORTANT This appliance is intended for towels washed in water Fabrics that contain soap or detergent residue may show what appears to be scorch marks However this may be the discoloration of the residue Mr Steam is not responsible for discoloring or damage of any fabrics Refer to the Mr Steam towel warmer warranty for additional terms and con ditions This picture shows the recommended method of draping a towel on a towel warmer Ensure as much as possible of the towel s surface is touching the towel warmer for optimum towel warming Installation Operation amp Maintenance Instructions INSTALLER READ THIS ENTIRE INSTRUCTION MANUAL THOROUGHLY BEFORE BEGINNING INSTALLATION LEAVE THESE INSTRUC TIONS WITH HOMEOWNER e BE CERTAIN ELECTRICITY IS SHUT OFF AT MAIN PANEL BEFORE ATTEMPTING TO WIRE OR SERVICE THE TOWEL WARMER Follow instructions to make certain the Towel Warmer is properly mounted and secured to the wall FAILURE TO FOLLOW THESE STEPS COULD RESULT IN HAZARDOUS CONDITIONS INCLUDING ELECTROCUTION e DO NOT alter or modify any Mr Steam products Doing so may result in an inoperable or hazardous installation and will void the warranty 1 Install in accordance with National and local codes Do not locate in show er stall tub or near water spray Do not locate within Shower Tub Zone Do not locate the towe
12. set screws N Mounting Bracket Il Mounting Screw m P 6 Bolt Sleeve r _ Towel Warmer 4 Locate the mounting brackets on the wall by measuring the mounting holes on the towel warmer 5 Using the screws provided secure the brackets to the wall 6 Insert the sleeves into the extensions Using the mounting bolts secure the extensions and sleeves to the 4 threaded holes on the towel warmer Mounting Bracket Extension s Mounting Bracket Set Screw Wiring Box G E eon Escutcheon KRJ Set Screw Wiring Box mr steam ELECTRICAL CONNECTIONS ANAGNI To PREVENT SHOCK HAZARD THE ELECTRICITY MUST BE TURNED OFF AT THE MAIN PANEL BEFORE ANY WIRING IS ATTEMPTED JANI The towel warmer is an electric device It must be installed by a licensed electrician in accordance with the National Electrical Code NEC and local code ARAIAN Installation of a wall switch or timer to turn the towel warmer on and off is required NOTE When the towel warmer is energized ON the indicator light on the towel warmer will illuminate Note The Towel Warmer wires are color coded BLACK for LINE WHITE for NEUTRAL GREEN YELLOW for EQUIPMENT GROUND ANSANTE Install Towel Warmers in upright position only Locate with wiring box and pilot light on bottom as shown on pages 4 amp 5 Failure to install properly may result in overh
13. utcheons Wires from Wiring Box Wiring Box Set Screw 3 Connect wires 4 Slide the wiring box into the per instructions wiring box escutcheon and tighten the set screw firmly Secure the upper threaded flanges and lower brackets with screws provided mr steam GENERAL The Towel Warmer requires 120 VAC 50 60 Hz power Specific amperage needed is list ed in the Towel Warmer Specifications Chart on page 3 of this manual A Electrical connections should be made as prescribed by the National Electrical Code and local code The unit should be field wired using 14 AWG min 90 C rated insu lated copper wire All models are to be protected by a separate 15 amp circuit breaker GFCI or equal B Make connections between Towel Warmer and house wiring using approved connections to comply with the National Electrical Code and local codes LINE black NEUTRAL white and GROUND AVAILABLE DIGITAL PROGRAMMABLE TIMER 1 Read the operating instructions provided with the timer 2 Disconnect power supply prior to installation to prevent electrical shock rc Installation Operation amp Maintenance Instructions Field Installed Wall Switch or Mr Steam Digital Programmable Timer PN 103588DIG E Electric Towel Warmer ANNIN TO PREVENT ELECTRIC SHOCK HAZARD NO BARE WIRE OR WIRE STRANDS SHALL BE EXPOSED AFTER MAKING CON NECTIONS ANZ SG Towel Warmer surf