1. connections with a wrench 6B 5 16 in to 3 1 8 ny Wall 6D INSTALLATION PROCEDURE 7 FOR TUB SPOUT INSTALLATION Place the spout 7A onto quick connection until the spout 7A becomes flush with the finished wall and tighten the screw 7B with with the Hex wrench Hex 3 97mm provided 8 CHECKING FOR LEAKS Place the handle 8A on the valve body connector 8B and turn the handle to the full on mixed position When the valve is turned on water normally flows through the tub spout 8C To activate the shower turn the valve on and pull the knob 8D up Hold the knob 8D until the water flows continiously from the shower arm 8E Check for leaks Shut off the water at the faucet and supply lines Remove the handle 8A 9 ESCUTCHEON AND HANDLE INSTALLATION Install the escutcheon 9A onto the valve body 9B using the escutcheon screws 9C Place the handle 9D onto the valve body 9B and secure it with the screw 9E Use a phillips screwdriver to tighten the screws Insert the index 9F into the handle 9D f UP FOR SHOWER ies e0 8c 8c 9A OF 10 SHOWER HEAD INSTALLATION Thread the shower head 10A to the shower arm 10B 10 10B TA ZY L TROUBLE SHOOTING o 545921 Polished Chrome o 545939 Polished Chrome Problem Faucet leaks from
2. Design House is a registered brand of DHI Corp el DESIGNHOUSE Mequon WI 53092 1 800 558 8700 MILLBRIDGE SINGLE HANDLE TUB amp SHOWER FAUCET and MILLBRIDGE SINGLE HANDLE SHOWER ONLY FAUCET lt Models 545921 545939 Your new Design House faucet will give you years of trouble free performance Thank you for choosing our product for your home Please read all of these instructions carefully before installing your new faucet Helpful tools to install this faucet e basin wrench e silicon sealer e Teflon tape e flashlight e 2 crescent wrenches e faucet supply tubes IMPORTANT POINTS e When installing your new faucet hand tighten the connector nuts then use one wrench to anchor the fitting and a second wrench to tighten the nut one additional turn Connections that are too tight will reduce the integrity of the system e Wrap threaded connections except aerator thread in spout or where o ring or rubber sealant are present with Teflon tape available from your local hardware or plumbing supply store Always wrap in a clockwise direction SAFETY TIPS e ALWAYS protect your eyes with safety glasses INSTALLATION PROCEDURE 1 Shut off the water supply to the tub and shower Verify that the hole sizes and positions of the holes in the wall are correct a The shower and tub spout outlet holes should be 1 1 4 in diameter b The valve access hole should be 6 in diameter c The recommended valve
3. depth to the finished wall is 2 in min to 2 1 2 in max Ensure that the valve body 1A cover is flush with the finished exterior surface of the wall Position the valve body 1A correctly in the wall with the UP pointing up The 8 in minimum from the valve body to the tub spout is required for proper operation 2 Fasten the body assembly 2A to crass brace with mounting screws 2B not included Note Be sure to position the body 2A correctly in the wall with the markings UP facing upward 3 TUB amp SHOWER OUTLET CONNECTIONS Wrap thread sealant tape around the pipe threads in a clockwise direction as shown Connect the hot and cold water supply lines 3A not included the shower 3B not included and tub outlet pipes 3C not included to the valve body 3D Connect the pipe elbows 3E not included to the ends of both pipes and tighten with a wrench Note a The hot water supply lines go into the H inlet and the cold water supply lines go into the C inlet b Do not use PEX or CPVC between the valve and spout 1 1 4 in Diameter 1 i 30 in Shower Only 48 in Tub amp Shower 6 in Diameter ii S ain Shower Only 1A Bin Min Y 30 in 1 1 4 in Tub amp Shower Diameter 2B 3 4 SHOWER ONLY OUTLET CONNECTIONS Wrap thread sealant tape around the pipe threads in a clockwise direction as shown Connect the hot and cold water supply li
4. then dry with a soft cloth CONSUMER PROTECTION WARNING Under the Safe Drinking Water Act the U S Environmental Protection Agency restricts the amount of lead used in brass and solder Your new faucet is made in strict compliance with all government standards The materials used in the manufacture of this faucet are of industry standard quality and are similar to other plumbing products having brass fittings To reduce the amount of lead in your drinking water allow the water to run for a moment before filling your glass and remember to always use cold water for drinking purposes
5. nes 4A not included the shower outlet pipe 4B not included to valve body 4C Wrap thread sealant tape around the threads of the plug 4D and insert it into the bottom outlet 4E Connect the pipe elbows 4F not included to the end of the pipe and tighten with a wrench Note The hot water supply lines go into the H inlet and the cold water supply lines go into the C inlet 5 FLUSHING Place the handle 5A on the valve body connector 5B and turn the handle 5A to the full on mixed position Turn on the hot and cold water supply lines and allow the water to flow from the outlets for one minute or until all foreign matter has been flushed out Check for leaks Shut off the water at the faucet and supply lines Remove the handle 5A 6 SHOWER FLANGE AND SHOWER ARM INSTALLATION Insert the long end of the shower arm 6A through the flange 6B then wrap thread sealant tape around long end of the shower arm 6A in a clockwise direction as shown Install the long end of the shower arm 6A into the pipe elbow inside the wall Tighten the shower arm 6A do not over tighten Wrap thread sealant tape around the pipe threads of the tub spout outlet 6C not included in a clockwise direction as shown Connect the tub spout outlet pipe the tub spout outlet pipe should project 1 5 16 in to 3 1 8 in from the finished wall to the lower pipe elbow 6D not included Tighten the elbow and tub spout outlet pipe
6. under handle Cause Adjusting ring or cap assembly has loosened Action 1 Move the handle to OFF position Remove the index unscrew the screw and remove the handle Unscrew the escutcheon screw and set screw then remove the escutcheon and connector 2 Tighten the adjusting ring by turning it clockwise with a small screwdriver Move the ball stem to the on position and continually tighten the adjusting ring until the leak stops draining out from around the ball stem 3 If the leak does not stop loosen the adjusting ring and tighten the entire cap assembly by turning it clockwise Re tighten the adjusting ring as before 4 Reinstall the handle Many of these parts come preassembled This exploded diagram is to assist in trouble shooting Escutcheon screw e Handle Screw Index Mixer ball Cam Cap oy a Adjusting ring N y Disc Connector Cam packing Set screw Escutcheon Disc spring MAINTENANCE Your new Design House faucet is designed to give you years of trouble free performance Avoid abrasive cleaners steel wool and harsh chemicals that will dull the finish and void your warranty Brass finishes are polished then protected with a lacquer coating to help prevent tarnishing Clean these surfaces only with a damp soft cloth Keep it looking like new by cleaning it periodically with a mild solution of soapy water Rinse thoroughly and