1. Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc www symmons com gethelp symmons com ZV 3072 REV A 09 25 14 Installation Note For valve body installation please see valve body installation guide 1 Attach secondary integral diverter R to shower escutcheon K 3 Install shower dome cover I to shower valve and secure with lock nut H 5 Install tub spout S to pipe fitting Turn clockwise to secure O 1 6 Install wall elbow B and flange C to recessed pipe fitting Turn elbow clockwise to tighten 2 Install shower escutcheon K to shower valve Secure with two screws J 4 Install handle G to valve Secure handle with star washer E and screw F Attach plug button D to handle Notes Handles should be facing the 6 o clock position 7 Press tab to remove mounting plate L2 from cradle mount cover L1 Ai Note Mounting plate L2 center tabs must be horizontal for removal Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc www symmons com gethelp symmons com ZV 3072 REV A 09 25 14 Installation 8 Place mounting plate L2 in
2. position mark and drill 1 8 pilot holes into stud 9 Install mounting plate L2 Secure with two screws M Replace cradle mount cover L1 Option Place mounting plate L2 in position mark and drill 3 16 holes into wall Install anchors OD Note Mounting plate L2 center tabs must be horizontal for installation 10 Attach cradle arm O and washer N to cradle mount L Secure with screw P 11 Attach large end of hand shower hose T to hand shower Q Attach small end of hand shower hose T and gasket to in line vacuum breaker A Connect in line vacuum breaker to wall elbow B Turn clockwise to tighten Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc www symmons com gethelp symmons com ZV 3072 REV A 09 25 14 Operation Temperature Control Diverter Control 1 Turn shower handle counterclockwise approximately 1 Turn diverter left for tub spout operation 1 4 turn to put valve in cold position 2 Turn diverter right for hand shower operation 2 Turn shower handle counterclockwise approximately 1 2 turn to put valve in warm position 3 Turn shower handle counterclockwise approximately
3. 3 4 turn to put valve in hot position Oj Care and Cleaning 1 Clean finished trim area with a soft cloth using mild soap and water or a non abrasive cleaner and then quickly rinse with water Troubleshooting Chart Problem Solution Finish is spotting Elements in water supply may cause Clean finished trim area with a soft water staining on finish cloth using mild soap and water or a non abrasive cleaner and then quickly rinse with water Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc www symmons com gethelp symmons com ZV 3072 REV A 09 25 14
4. EEA EEA ad SYMMONS the smart choice S 4304 TRM Sereno Tub Hand Shower Trim Operation amp Maintenance Manual Model Numbers O S 4304 TRM Tub Hand Shower Trim Specifications Tub hand shower trim with lever handle and secondary integral diverter handle includes wall connection cradle for hand shower mounting non diverter tub spout in line vacuum breaker flexible metal hose and 1 mode hand shower with 2 5 gpm 9 5 L min flow restrictor Components made from metal and nonmetallic materials plated in standard polished chrome finish Modifications Warranty O 1 5 amp 1 5 gom 8 7 L min flow restrictor O 2 0 e 2 0 gpm 7 6 L min flow restrictor O 432HSB 30 slide bar in place of wall cradle on hand shower units O STN Satin nickel finish Note Append appropriate suffix to model number Limited Lifetime to the original end purchaser in consumer installations 5 Years for commercial installations Refer to www symmons com warranty for complete warranty information Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc www symmons com gethelp symmons com ZV 3072 REV A 09 25 14 Dimensions LLELLL LLL A 5 LLLELL LEE n T H Pii ae i i i ZIZ
5. I X eg VLZLLLLLL i N N Floor 1 Notes 1 All dimensions measured from nominal rough in see J as reference 2 Dimensions are subject to change without notice Measurements 2 1 4 57 mm Female 1 2 IPS thread must be recessed 7 8 from finished wall 5 3 4 146 mm 9 1 4 235 mm 3 1 2 89 mm 32 813 mm IIOIni miIoJlIO 12 305 mm 4 1 2 114 mm 3 1 4 83 mm jC Rough in 2 3 8 1 2 60 mm 13mm 2 3 8 60 mm 1 2 NPT 1 2 13 mm 8 1 2 216 mm Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc www symmons com gethelp symmons com ZV 3072 REV A 09 25 14 Parts Breakdown Replacement Parts Vacuum Breaker 60 Hose Erie Wall Elbow Flange T 444 KIT Plug Button O ring Set Screw Handle Locknut Dome Cover ZTrsl oOomnmMmMoo oOW AyS T 19 20 PL Mounting Screws Shower Escutcheon T 249A Cradle Mount Cradle Mounting Screws Washer T 545 Cradle Arm Set Screw Hand Shower 432W Diverter Handle T 30M ollo vozzrj xcec Tub Spout 432TS Notes 1 Append STN to part number for satin nickel finish 2 Append 1 5 or 2 0 to hand shower for low flow Required for Installation Adjustable wrench Phillips head screwdriver Plumber tape
Download Pdf Manuals
Related Search
Related Contents
Melissa 245067 Coffeemaker User Manual User manual for T06A - Bea-fon Thiel Audio Products CS2.3 User's Manual GoTalk 9+ Bedienungsanleitung La Fundación Damián en Burundi RayBio® Human Follistatin ELISA Kit Samsung ME71A/AND User Manual Copyright © All rights reserved.
Failed to retrieve file