Home

American Standard 2832.128.021 Installation Guide

image

Contents

1. 5332 016 XXX Elongated Seat 738565 442 0070A Fluidmaster 400A Inlet 5331 016 XXX Round Front Seat 7381043 400 0070A Flapper Assembly 1 28 GPF w Float 735122 400 XXX0A 10 Tank Cover 735121 400 XXX0A 12 Tank Cover 735123 400 XXX0A_ 14 Tank Cover In the United States American Standard Brands P O Box 6820 Piscataway New Jersey 08855 Attention Director of Consumer Affairs For residents of the United States warranty information may also be obtained by calling the following toll free number 800 442 1902 www americanstandard us com In Canada AS Canada ULC 2480 Stanfield Rd Mississauga Ontario Canada L4Y 1S2 Toll Free 800 387 0369 In Mexico Customer Service Manager AS Maauila S A de C V Via Morelos 330 Col Santa Clara Ecatepec 55540 Edo Mexico www americanstandard com mx www americanstandard ca 730928 100 Rev K
2. Toilet does not shut off Sand or debris lodged in water control REPAIR PARTS LIST Repair parts are determined by toilet tank number which can be found marked inside tank NOTE XXX represents color or trim finish options Specify when ordering PART NUMBER 738903 XXX0A DESCRIPTION Tank Lever LH Flush valve chain too tight holding flush valve open Flush valve seat and or flapper worn or deformed Readjust chain length as needed Review Step 10 Shut off water supply Replace flush valve Shut off water supply Remove cap and clean per Step 13 Complete 3305 3378 3339 Complete 2880 2852 3377 3329 Complete 2447 3379 Complete 2447 Complete 2880 2852 Complete 3305 034783 XXX0A Bolt Cap Kit lt e e 4019 128 e e 4021 513 738565 423 0070A Fluidmaster 400A Inlet J J J 4021 128 4027 128 738921 100 0070A Flushvalve Assembly 1 6 GPF ajeje je 4021 738921 101 0070A Flushvalve Assembly 1 6 GPF 738921 102 0070A Flushvalve Assembly 1 6 GPF 738920 100 0070A Flapper Assembly 1 6 GPF SoS Mi 4021 500 738921 103 0070A Flushvalve Assembly 1 28 GPF 738921 104 0070A Flushvalve Assembly 1 28 GPF 738921 105 0070A Flushvalve Assembly 1 28 GPF 7381026 400 0070A 7301021 0070A Flapper Assembly 1 28 GPF Tank Coupling Kit 252 738916 100 0070A Refill Tube 5 inch 738916 101 0070A Refill Tube 9 inch
3. INSTALL TANK a Install large rubber gasket over threaded outlet on bottom of tank and lower tank INSTALL TOILET onto bowl so that tapered end of gasket fits evenly into bowl water inlet opening a Position toilet squarely to wall and with a rocking and tank mounting bolts go through motion press bowl down fully on wax ring and flange mounting holes Secure with metal Alternately tighten nuts until toilet is firmly seated on floor washer nut combo WASHER NUT With tank parallel to wall alternately tighten nuts until tank is snugged down A CAUTION evenly against bowl surface DO NOT OVERTIGHTEN NUTS OR BASE MAYBE DAMAGEDI USE INCLUDED TOOL NUT DRIVER OR DEEP SOCKET RACHET Install caps on washers If necessary cut bolt height to size before installing caps A CAUTION DO NOT OVERTIGHTEN NUTS MORE c Smooth off the bead of sealant around base THAN REQUIRED FOR A SNUG FIT Remove excess sealant INSTALL TOILET SEAT Install toilet seat in accordance with manufacturer s directions Before continuing determine the type of water supply connecation you have from the chart below and use the appropriate assembly parts required to properly reconnect the water supply DO NOT use plumber s putty to seal these fittings METAL COPPER METAL FLANGED METAL SPIRAL VINYL BRAIDED FLARED TUBING TUBING TUBING CONNECTOR E LOCK NUT N LOCK NUT EPS Lock NUT N LOCK NUT CONE EXISTING EXISTING lt
4. TO LEAK SLOWLY repeat Step 13 IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF NON USE it is a signal you are wasting water because e The end of the refill tube is inserted into overflow pipe below water level in tank Attach refill tube to overflow pipe using S clip provided e The flush valve is leaking because it s worn dirty or misaligned with tank ball or flapper replace with a new flapper IF FILL VALVE WON T TURN ON OR SHUT OFF or REFILL OF TANK WATER IS SLOW after valve has been in use for some time Fluidmaster Model 242 Replacement Seal may be needed Go to our website at www fluidmaster com for more solutions IMPORTANT Always clear to toilet problems e While holding a container sand and rust from system over the uncapped VALVE e Replace TOP by engaging lugs and rotating 1 8 turn clockwise MAKE CERTAIN For troubleshooting information please contact e Make sure water supply is off Remove valve TOP by lifting arm and rotating top and arm 1 8 turn counterclockwise pressing down slightly on cap to prevent splashing turn water supply on and off a few times Leave water supply off TIP IS TURNED TO THE LOCKED POSITION VALVE MAY NOT TURN ON IF TOP IS NOT FULLY TURNED TO THE LOCKED POSITION Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products Fluidmaster shall not be responsible or liable for any damages caused by products used with Fluidmaster valves th
5. WASHER WASHER GONE COUPLING EXISTING WASHER NUT 7 COUPLING COUPLING NUT NUT WATER WATER 9 WATER SHUT OFF SHUT OFF SHUT OFF ge SHUT OFF These parts must be used as Use existing Use existing spiral Captive cone illustrated to insure water tight coupling nut cone washer washers already connection Use of existing and washer Fluidmaster cone included No coupling nut may result in washer may not additional washers water leakage Water supply seal completely on needed A tube or pipe must extend at spiral type supply With correct washers in least 1 2 inside threaded line place see Step 9a shank of valve does not tighten COUPLING NUT apply to flanged tubing 1 4 turn beyond hand tight s CAUTION Overtightening of CAUTION DO NOT USE LOCK NUT or COUPLING NUT DO NOT OVERTIGHTEN CONE WASHER WITH could result in breakage and PLASTIC SUPPLY LINE potential flooding WARNING Do not use plumber s putty pipe dope or any other sealant on the water supply connection to this tank If the connection leaks after hand tightening replace the supply line If the connection continues to leak with the new supply line replace the fill valve Warranty is void if any type of sealant is used on the water supply connection D a 730928 100 Rev K ADJUSTMENTS a Adjust water level Water level should be adjusted to level indicated on tank by adjusting float cup CRITICAL LEVEL MARK
6. new toilet is installed NOTE Distance from wall to closet flange centerline must be as listed on chart MODELS DIMENSION A 2383 010 2384 010 254mm 10 2386 010 3379 128 2383 012 2829 128 2386 012 2832 128 2384 012 2835 128 3305 000 2838 128 305mm 12 2431 012 2852 000 SURELY 2447 000 2852 128 REQ D 2880 000 2447 128 3377 128 2880 128 3378 128 3329 128 FINISHED 3339 128 amp S ricn ot 10 ROUGHS FINISHED WALL FLOOR 3 2383 014 2384 014 356mm 14 5 2386 014 CLOSET SEALANT FLANGE TAPERED CLOSET BOLT ane FLANGE Pa INSTALL WAX SEAL INSTALL CLOSET BOLTS Invert toilet on floor cushion to prevent POSITION TOILET ON FLANGE Install closet bolts in flange damage and install wax ring evenly a Unplug floor waste opening and install toilet on closet flange channel turn 90 and slide around waste flange horn with tapered so bolts project through mounting holes into place 6 152mm apart end of ring facing toilet Apply a thin bead b Loosely install retainer washers and nuts Side of washers and parallel to wall of sealant around toilet base marked THIS SIDE UP must face up Product names listed herein are trademarks of AS America Inc 730928 100 Rev K AS America Inc 2009 U S FUTURE R FO SAVE For Tanks Bowls using Speed Connect System Tank mounting bolts pre installed TANK MTG 7 BEER BOLTS PRE BOLT CAP INSTALLED WASHER NUT COMBO
7. C L See Step 11 for water level adjustment method b If bowl fails to siphon an adjustment may be required with the lift chain Simply remove the bead chain from the retainment clip and take up slack on the chain and reinsert on lift rod Make sure the chain is not too taught WATERLEVEL ADJUSTMENT 3 a a4 Y ADJUSTABLE HEIGHT J e Sr _I Turn on water supply Submerge the FLOAT CUP under the water for 30 THREADED seconds Adjust the water to ae desired level by turning WATER LEVEL ADJUSTMENT ROD and moving FLOAT CUP up or down LOCK NUT CONE WASHER ry PARTS FOR WATER CONNECTION COUPLING NUT WW SEE STEP 9 HAND TIGHT ONLY T Diagram 1 CARE AND CLEANING When cleaning your toilet wash it with mild soapy water rinse thoroughly with clear water and dry with a soft cloth Avoid detergents disinfectants or cleaning products in aerosol cans NEVER use abrasive scouring powders or abrasive pads on your toilet seat Some bathroom chemicals and cosmetics may damage the seat s finish WARNING Do not use in tank cleaners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage American Standard shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing chlorine calcium hypochlorite TROUBLESHOOTING IF FILL VALVE SHUTS OFF BUT CONTINUES
8. INSTALLATION INSTRUCTIONS Americam Standard CARE AND MAINTENANCE Style That Works Better CADET 3 1 6 GPF TWO PIECE TOILET CADET Models 2383 2384 2386 2447 2431 2880 3305 2852 shing System CADET 3 FloWise 1 28 GPF TWO PIECE TOILET Models 2829 2832 2835 2838 2880 3305 2447 2852 3329 3339 3377 3378 3379 Thank you for selecting American Standard the benchmark of fine quality for over 100 years To ensure this product is installed properly please read these instructions carefully before you begin Certain installations may require professional help Also be sure your installation conforms to local codes A CAUTION PRODUCT IS FRAGILE TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE NOTE Pictures may not exactly define contour of china and components RECOMMENDED TOOLS AND MATERIALS Putty Knife Regular Screwdriver Adjustable Wrench Sealant Tape Measure Hacksaw Wax Ring Gasket Flexible Supply Tube Closet Bolts Carpenters Level REMOVE OLD TOILET Close toilet supply valve and flush tank completely Towel or sponge remaining water from tank and bowl Disconnect and remove supply line NOTE f replacing valve first shut off main water supply Remove old mounting hardware remove toilet and plug floor waste opening to prevent escaping sewer gases Remove closet bolts from flange and clean away old wax putty etc from base area NOTE Mounting surface must be clean and level before
9. at were not manufactured by Fluidmaster Inc Fluidmasterlme 30800 Rancho Viejo Road San Juan Capistrano CA 92675 949 728 2000 800 631 2011 www fluidmaster com 2001 Fluidmaster Inc Registered trademark of Fluidmaster Inc 730928 100 Rev K TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Does not flush Water supply valve closed Supply line blocked Sand or debris lodged in water control Flush valve chain too loose or disconnected Open valve and allow water to fill tank Shut off water supply disconnect supply line and inspect all gaskets and washers Reassemble Also see Fluidmaster maintenance see Step 13 Readjust chain length as required Shut off water supply Remove cap and clean as per Step 13 Poor or sluggish flush Bowl water level too low Supply valve partly closed Supply pressure too low Partially clogged trapway and or drain pipe and or vent Check that refill tube is connected to water control and inserted into tank overflow without being kinked or damaged b Open supply valve fully Be sure that proper supply tube size is used Remove obstruction Consult a plumber if necessary Normal supply pressure must be at least 20 psi Toilet leaks Poor supply line connection Poor bowl to tank floor connection Review Step 9 of installation procedure Review Step 4 through 7 of installation procedure

Download Pdf Manuals

image

Related Search

Related Contents

Siig 2-port FireWire 800 ExpressCard  Instructions - RS Components International    - A.J.Pinto  Honda EB11000 User's Manual  NSD8-C8I(八郎潟仕様)取扱説明書  

Copyright © All rights reserved.