1. m POP UP KNOB 1 must be fully down Fig B M968625 Rev 1 1 r ATTACH CABLE CONNECTOR E Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 O D Fig B 8 CHECK OPERATION OF POP UP E Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions 9 MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY Thread TEE BODY 4 to SPOUT SHANK 5 m Thread HOSE CONNECTOR 6 6A to VALVE CONNECTIONS 7 7A m Connect water supply to VALVE BODIES 1 1A with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 0 D BULL NOSE RISERS 3 Use 3 adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length E Connect HOT water supply to inlet of left SHANK and COLD water supply to right SHANK using sealant appropriate connectors and COUPLING NUTS COUPLING m Connect 1 1 4 O D tailpiece on POP UP DRAIN to 3 waste outlet 1 3 8 0 D BULL NOSE 1 2 PIPE THREAD RISERS COMPRESSION NUT FERRULE c q FLEXIBLE SUPPLIES 3 8 COMPRESSION CONNECTIO
2. BODY 13 through valve mounting holes Threads of VALVE BODY 13 should extent at least 5 16 of a inch above mounting surface top Fig B Thread ADAPTER 10 onto VALVE BODY 13 until snug against internal stop If necessary adjust LOCKNUT 191 m Tighten LOCKNUT 11 with WRENCH 8 supplied to secure VALVE BODY 13 Repeat above steps for opposite VALVE BODY 134A MOUNTING SURFACE P POP UP DRAIN Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B 3 REMOVE FLANGE mM Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2 from drain body Fig A mM Thread LOCKNUT 3 clockwise to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE 5 TIGHTEN LOCKNUT E From under side of SINK install DRAIN BODY 1 up through drain outlet m Tighten LOCKNUT 1 firmly with Adjustable Wrench or Channel Locks Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK E Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly 6 FLANGE GASKET AND POP UP KNOB m Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible Fig A
3. ANDLE BASE 1 from DECK ADAPTER 2 VALT AE er eee Pull HANDLE ASSEMBLY off VALVE STEM 3 CLOTH Remove SPRING CLIP 4 Lift STOP WASHER 5 turn 90 and replace Replace SPRING CLIP 4 DO NOT DO NOT CLEAN THE Find correct position of HANDLE ASSEMBLY by adjusting male teeth on VALVE STEM 3 to female teeth in HANDLE ee Ae Thread HANDLE ASSEMBLY onto DECK ADAPTER 2 POLISH ABRASIVES HARSH until snug against mounting surface CLEANERS OR A CLOTH WITH f t dri erd iu spout drips operate handles several times from A COARSE SURFACE OFF to ON position Do not force handles turn only 90 968625 Rev 1 1 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If Stopper does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwi
4. Americam Standard Installation Instructions STUDIO 2990 801 Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American Standard faucets Speed Connect Drain e Fewer parts installs in less time e Never needs adjustment Certified to comply with ANSI A112 18 1 Guaranteed to seal properly the first time every time M968625 Rev 1 1 Your new American Standard faucet is designed to work only with the Speed Connect drain To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Recommended tools LE L Screwdriver Channel Locks Adjustable Wrench Tubing Cutter Turn off hot and cold water CAUTION supplies before beginning 1 INSTALL SPOUT E Insert SPOUT 1 and CABLE CONNECTOR 2 through center hole making sure the SEAL WASHER 3 is properly seated Assemble RUBBER WASHER 4 with BRASS WASHER 5 and LOCKNUT 6 onto SPOUT SHANK 7 from under side of sink Make sure SPOUT 1 is centered in the mounting hole and the slot in the BRASS WASHER 5 faces toward the rear of the sink m Tighten LOCKNUT 6 firmly Fig A 1 A INSTALL VALVE BODY m Place RUBBER RING 9 into ADAPTER 10 E Install LOCKNUT 11 and RUBBER WASHER 12 onto VALVE BODY 13 From under side of mounting surface install VALVE
5. N M968625 Rev 1 1 INSTALL HANDLES Push ADAPTER 1 on VALVE STEM 2 so that the hole of the ADAPTER 1 without a spline is facing up Fig A Tighten STEM SCREW 3 to secure ADAPTER 1 THREAD ON TO DECK ADAPTER m Find correct position of LEVER HANDLE ASSEMBLY 4 by adjusting male teeth on ADAPTER 1 to female teeth in HANDLE 4 Thread LEVER HANDLE ASSEMBLY 4 onto DECK ADAPTER 5 until snug against mounting surface SPLINE END DOW 1 1 TEST INSTALLED FITTING m With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks gt mM Remove AERATOR 3 Cc mM Operate both HANDLES 1 to flush water r CD lines thoroughly SS iN Pol E Replace AERATOR 3 1 P CHECK DRAIN CONNECTIONS I E Operate POP UP KNOB 5 and fill Sink with water Check that DRAIN STOPPER 4 makes a good seal and retains water in Sink If STOPPER 4 does not seal properly please refer to Troubleshooting Guide in these instructions I VVS AA D N E Release POP UP KNOB 5 down and check all drain connections and P trap for leaks m Tighten if necessary VVVVVVVVVVVP NM Pp TRAP 1 3 CARE INSTRUCTIONS HANDLE E To change direction of handle rotation ASSEMBLY DO SIMPLY RINSE THE PRODUCT proceed as follows UANHRERD CLEAN WITH CLEAR WATER DRY m Turn valve to OFF position Unthread H
6. nlocked mode and removable INSTALL CAM CAP M968625 Rev 1 1
7. se direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F SOE REMOVE CAM CAP M968625 Rev 1 1 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode m Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G m To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessar
8. y so that the Stopper slides all the way down Fig G gs Reinstall the Cam into the Drain rotating the Cam if necessary to make sure it Is fully inserted Fig J Re install the Cam Cap making sure the guide teeth are facing outward If the Cam Cap does not snap into place then rotate the Cam to make sure tt Is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in 7 Troubling Shooting Guide to complete installation Stopper will be Locked Mode in Locked mode and not be removable Vandal Proof Unlocked Mode n Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into m the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain rotating the Cam if necessary m to make sure tt is fully inserted Fig J LOOP TOWARD Re install the Cam Cap making sure the guide teeth are facing FRONT OF SINK outward If the Cam Cap does not snap into place then rotate Or the Cam to make sure it is fully inserted Fig K DRAIN Re attach Cable See CABLE ADJUSTMENT PROCEDURE in n Troublingshooting Guide to complete installation Stopper will be Unlocked Mode in U