Home

eLEDing EE818WDC(WW) Use and Care Manual

image

Contents

1. eLEDing Model EE818WDC User Manual arm White Built with CREES LED Smart Solar Light Murine LED Lighting IMPORTANT Read this User Manual Before Installing Included in this package Or Initial Installation Set up Refer to Fig 1 ii Connecting the Battery before setting up 1 The battery has been pre charged before shipping and the light is ready for use 2 Make sure the main switch is in the OFF position 3 Open the battery cover on the back of the light and plug the battery into the connector and carefully make sure the plug position is correct then replace the cover Fig 1 1 4 Initially check the light and battery by moving the switch to AUTO then SMART ON it should light up then turn the switch back to OFF for installation Mounting the Light Body 1 The light body must only be mounted in a vertical position and it should be mounted at least 6 to 10 feet above the ground 2 Choose a flat and safe mounting surface Mark the screw positions through the mounting plate screw holes onto the mounting surface Use 2 or 4 hole mount Fig 1 2 amp 1 3 3 For wood vinyl and metal surfaces mount the back plate directly with provided screws Drill clearance holes using a 3 16 masonry bit for surface of concrete brick or stucco Insert the anchors provided with screws then position the mounting plate and screw the fasteners in securely 4 Attach the light body unit to the wall mounting plate Slide the whole
2. sunlight for 1 2 days Or charge for 2 3 hours using only our optional accessory AC DC Digital Switched Power Adapter EE DPS 0 8A User Tips video reference youtube com watch v 5eQWsWagFvBA Table Light Conversion using optional Table Stand accessory EE45 80 18 PBS Fig 5 This f option converts the light to a portable table light for camping picnics reading studying and other indoor or outdoor activities Use as a Table Light during low light level conditions Move switch to SMART ON then make sure to select Mode A Fig 3 then adjust Left S Dial Dimming for desired reading light level An optional AC DC digital power adapter EE DPS 0 8A can be used as a quick charger Also with this i adapter it can be used in either AUTO or SMART ON as a standard AC DC powered motion sensing flood light with battery back up capability for indoor outdoor security safety lighting applications It can be wall or table mounted or used as a standard portable table light Fig 5 Fig 5 Table Stand amp DC Power option Adapt Option Avoid placing objects in front of the motion detector that may affect detecting performance Avoid installing the unit near air conditioners central heaters or high voltage systems Avoid placing the motion detector head towards street traffic or other high movement areas which cause excessive triggers resulting in shorter battery reserve capacity If this situation is unavoidable decrease th
3. disable if 10 minutes has passed without motion being detected During this mode the indicating Red LED light will flash through the motion detection lens providing visual confirmation of motion detection adjustments When a period of 10 minutes passes without motion detection the unit will automatically switch to normal operation mode and will start illuminating once it senses a change to darkness from daylight ambient light conditions 4 After the initial Set up Walk Test is complete the main switch may either be kept in the AUTO profile for Security sensing flood lighting or moved to the SMART ON profile for Dusk to Dawn security and safety lighting SMART ON is the recommended mode providing both Security and Safety lighting Note The Red LED indicator light inside the ball head flashes for the following reasons 1 To indicate motion activity during the 10 minutes initial Set up Walk Test 2 To indicate the battery is low when the sensor detects motion during darkness 3 To indicate charging status during normal charging either in Sunny Partly cloudy and cloudy daytime periods or when the AC DC digital charger option is being used for charging in any conditions Storage If this unit has been stored over six months before initial operation then the battery may need to be re charged To re charge the battery after storage turn the main switch to OFF connect the battery plug the wire cord from the solar panel to the light and place it in direct
4. light body and then tie the unused cord behind the solar panel with the plastic zip tie that is provided Fig 1 7 4 Then mark the screw holes through the mounting bracket and secure the solar panel in position with the provided hardware 5 Firmly plug the solar panel plug into the bottom of the light body Fig 1 8 The RED LED indicator in side the motion ball will begin to double flash Fig 1 8 indicating that charging status is active during a normal daytime sunny partially sunny or cloudy day If this does not happen please check that the plug is fully plugged into the light body or if there is a problem with the wire Tia A Set up Walk test is used to establish the motion sensitivity Delay Time and Brightness level settings for the light After the Set up Walk test is Delay Time 5 180 on Auto Sensitivity Range completed the main switch can be set to either the AUTO lighting profile or Or Dimming with SMART ON 10 60 the SMART ON recommended lighting profile test is described on pg 3 Left Dial Right Dial eLEDing SMART Lighting Profiles amp Settings eLEDing Intelligent microprocessor controlled Solar Light offers two principal operating profile modes The Sensitivity Range of motion length of illuminating time and levels of brightness and dimming are set and controlled with adjustable dials Fig 2 There are two principal operating profiles for the light These are AUTO profile and SMART ON p
5. light body onto the wall mount plate from top going down with the light body hinged to the mounting plate Fig 1 4 Then secure the mounting with the small securing screw on bottom of the light body Fig 1 5 5 With the light body firmly secured in its mounting position the Pan amp Tilt adjustment features can be used to adjust the direction of the motion detector and the light head directions for optimal performance and coverage The direction and angle of the motion detector can be adjusted Fig 1 9 The LED light head can also be adjusted horizontally 180 forward and backward 120 Fig 1 10 Mounting and Connecting the Solar Panel 1 The solar panel must be mounted in a non obstructed position where it will receive an average of at least 4 hours daily of direct sunlight all year round It should be mounted with a tilt of 35 80 degrees Fig 1 6 A sturdy mounting location such as a wall roof on top of patio under the eaves secure pole or floor ground base This is required to make sure the solar panel is fasten down properly for all weather conditions 2 For Northern hemisphere installations the solar panel should be mounted with a Southerly facing position and visa versa for Southern hemisphere installation should face to the North Australia South Africa South America e g 3 Attach the hardware mounting bracket to the solar panel Determine how far of the 10 connecting wire cord is needed to reach the position of the
6. light will brighten up to the pre set factory fixed max level and then dim back down to the level set by the user Left Dial Caution The higher the minimum soft glow level is set to the more stored battery energy is used to provide soft glow lighting If the IPM detects that the battery does not have enough capacity to run this mode it will automatically go into AUTO profile to provide safety lighting until it receives enough sunlight to operate the feature correctly In both Modes A amp B If your geographic location has outstanding daytime sunlight conditions all year California New Mexico Florida of USA e g then you can increase the dimming level or brightness level and take advantage of a brighter projection of Moonlight soft glow Dusk to Dawn lighting The Sensitivity Range adjustment functions and setting are identically as described for the AUTO profile For most applications the recommending factory preset is Mode A default Fig 3 In both AUTO and SMART ON profiles if the IPM detects that the battery does not have enough capacity to run either profile in critical weather conditions it will automatically disable illuminating function leaving only the charger active to protect the battery from over discharge causing damage Once enough sunlight is received to charge the battery the unit will go back to AUTO profile if set in AUTO If set to SMART ON profile then it will first go into AUTO profile until it receives enough sunlight energy t
7. CC Part 15 Class B and ICES 0O03 2004 EE8 amp 815WDC BP Solar Powered Ultra Bright 5W CREE LED eMitter Self y oO p f ONG p 9 Contained Flood Spot Building Security amp Safety Lights white CCTV illuminator Specifications eStreet amp ePower EE8 amp 10 30W SCLH EE810 30W SSLH EE810W SPZ EE810 30W SRLH EE840 60W SPG Contact Info 877 579 3889 info eesgi com www eesgi com Rev EE818WDC 032015 Page 4
8. e price of the product under any circumstances The consumer is responsible for the installation of removal of and reinstallation of the product Customer Service 877 579 3889 www eesgi com Rev EES18WDC 032015 Page 3 Introduction and Intellectual Property Rights Statement Thank you for purchasing the eLEDing LED Smart Solar Lights With its effortless setup and lightweight design the eLEDing LED Smart Light conforms to all your lighting needs It was designed and made to provide many years of trouble free service using environmentally friendly Solar Hybrid Lithium based energy technologies Covered under multiple US European China and other international patents granted and pending worldwide All rights reserved a Introduction eLEDing Technology Related Green Systems EE814WDC Solar Powered Ultra Bright 4W CREE LED eMitter n Flood Spot Building and fal q lt Bed Parking Lot Security amp A D Safety Lights white CCTV illuminator oe gi Specifications a C Coverage Up to 180 sensing angle Detecting Range 180 up to 60 x 60 L 10 M 35 H 60 Light Head 4W Single super bright LED Cree USA Energy Storage 11WH Li poly battery Solar Panel L2VDC 4W Tempered Glass with 10 cable Mode A for 80 hrs continuous B for 9 80 hrs Weight 1 0 LBs Light Body Operation Temp 4 F to 125 F Weatherproof IP54 Brightness GOW Halogen Lamp On Peak 5 7M color Complies with F
9. e sensitivity and delay time to achieve optimal balance Motion detector is more sensitive to motions across the device and less sensitive to motion moving towards or away from it The solar panel should be mounted where maximum sunlight can be collected Typically the solar panel should face south and avoid facing north for Northern Hemisphere only opposite way for Southern Hemisphere with 35 80 tilt up direction Refer to Fig 1 8 It s fine facing to West or East where sunlight can directly charge the panel for at least 4 hours per day on average Use a soft wet cloth to periodically at least once a one year clean the solar panel to avoid the reduction of energy output due to accumulated dust Clean accumulated snow as soon as possible during the snowing season Product Specifications Coverage Up to 180 sensing angle Detecting Range 180 up to 60 x 60 L 10 M 35 H 60 Light Head 8W Single super bright LED CREE USA Energy Storage 23WH Li poly battery Solar Panel 13VDC 8W Tempered Glass with 10 cable Mode A for 80 hrs continuous B for 9 80 hrs Weight 1 7 LBs Light Body Operation Temp 4 F to 125 F Weatherproof IP54 Brightness LOOW Halogen Lamp On Peak 5 7Mcolor Complies with FCC Part 15 Class B and ICES 003 2004 Note Installation with factory default settings is recommended for most applications Optional Accessories AC DC Power Adapter EE DPS 0 8A Must be switch type di
10. gital 12VDC 0 5 1 5A with current limited power supply Fig 5 Table Stand EE45 80 18 PBS For use as a table light Fig 5 Solar panel 15 extension cable EE SPEC 15F Important Safety Information Please unplug the battery when shipping the light or packing for fight traveling Do not dispose of battery in fire as this may result in an explosion Do not expose the light to fire or intense heat as the battery may explode Do not immerse in water Never look directly into the light or shine it into another person s eyes Follow proper safety tips to prevent injury such as falling from a ladder during installation Consult your local Bi Laws or local safety guide lines for installing the light fixture on a building One Year Limited Warranty EESGI guarantees this product to be free from defects in material amp workmanship for 1 year This warranty does not apply to damage from misuse or incorrect installation connection This warranty does not cover accessories bulbs batteries accidents alterations unauthorized use or repair neglect misuse abuse damages or defects resulting from normal wear and tear including chips fading scratches abrasions or discoloration due to usage or sun exposure or failure to follow instructions for care and maintenance fire flood and Acts of God This warranty does not include liability for incidental or consequential damages EESGI is not responsible for any damages in excess of the retail purchas
11. he light brightens up or dims down after motion has been detected Ref Fig 3 Fig 4 Unusual Positions Light Head must only be mounted VERTICALLY only Fig 3 A amp B Mode Do not mount in any unusual positions as shown in Factory default is Mode A and Fig 4 preset with maximum brightness A In Mode A maximum brightness is controlled and set by the user In this mode the dual function Delay Time dial functions as a Brightness dial for setting the light level from lowest to maximum brightness Left Dial When motion is detected it will brighten up to the level as pre set by the Left Dial and when motion stops it will slowly dim down to the lowest factory fixed pre set moonlight soft glow lighting Caution The higher the brightness level is set to the more stored battery energy is used when activated by motion If the IPM detects that the battery does not have enough capacity to run this mode it will automatically go into AUTO profile please refer to AUTO profile description to provide safety lighting until it receives enough sunlight to operate the feature correctly Mode A also allows the brightness level to be adjustable as a portable or table reading studying light in low level light conditions B In Mode B the minimum soft glow lighting is controlled and set by the user In this mode the dual function Delay Time dial functions as a minimum dial setting the dimming level of moonlight soft glow lighting When motion is detected the
12. nge for the application This adjustment has a motion sensing range from Low 10 Med 35 High 60 For most applications set the dial to between M H in warmer temperature conditions set this slightly higher Cautions 1 Adjust the Sensitivity Range so that it is not set too sensitive this will increase false activations and reduce stored battery energy 2 If the IPM feature detects that the battery does not have enough stored energy to operate at full brightness when AUTO profile is set then it will automatically reduce the light level to half brightness in order to maintain a level of safe lighting until it again receives enough sunlight in good weather condition to restore it back to normal status SMART ON Profile Operation In SMART ON profile switch position set to SMART the solar light operates as a true Dusk to Dawn light The unit senses its surrounding ambient light level and will turn on in darkness providing adjustable moonlight soft glow lighting all night long When motion is detected it lights up to it s maximum brightness or pre set brightness within the set sensitivity range In new or if replacing existing AC light applications SMART ON is the recommended profile when used as a outdoor and indoor light for Security and Safety lighting It can also be used to enhance CCTV applications to illuminate coverage area of the camera The SMART ON profile has two selectable innovative SMART Modes A or B to optimize the way t
13. o operate SMART ON profile properly Important Note The A amp B Modes only operate in SMART ON profile They do not function if it is set with AUTO profile Rev EE818WDC 032015 Page 2 set Up Walk Test Procedure and Adjustments 1 To set up eLEDing for your applications the unit comes with a Set up Walk Test mode to ensure proper installation and performance is optimized To activate this mode move the main switch from OFF to AUTO position This mode can be reactivated at anytime to adjust your settings for your application by sliding the switch to OFF then AUTO in any condition day or night 2 When the main switch is set initially to AUTO from the OFF position for a period of 10 minutes the Set up Test mode will be active allowing the user to adjust the light settings This mode will work in day or night time conditions The length of Delay Time for light illumination can be adjusted at this time for your application from 5 seconds minimum to 180 seconds maximum During this Set up Test mode set this time to 5s for testing purposes once you are satisfied with your set up then set it to your application 180 seconds is recommended The Motion Sensitivity Range can be adjusted at this time for your application from 10 minimum to 60 maximum also in conjunction adjust the motion detector head using the Pan and Tilt feature for your application during this time 3 The Set up Walk Test mode is active as long as motion is seen or will automatically
14. rofile The family of eLEDing solar lights use an exclusive Intelligent Power Solat DC power input Management IPM embedded feature for managing and optimizing K eN the Lithium based battery for a full range of operation This optimizes OFF AUTO SMART ON Security lock screw the battery s life cycle to adapt to most environmental conditions Sa eh Sikei tch position including OFF allowing both the battery and light to perform for many years W a a a a a a l Fig 2 Light Profiles amp Settings Rev EE818WDC 032015 Page 1 eLEDing SMART Light Profiles amp Settings AUTO Profile Operation In AUTO Profile the solar light operates as a motion sensing light and it lights up to full brightness when motion is detected The motion Sensitivity Range can be adjusted by the Right Dial the delay illuminating time that the light stays on after activation can be adjusted by the Left Dial Ref Fig 2 page 1 The illuminating Delay Time can be set using the Left Dial to set the desired length of time for the light to be on after motion is detected It is adjustable from 5 to 180 seconds The light on time will be extended as long as motion is continually detected and It will not turn off until the motion has stopped and after the illuminating Delay Time has expired When set to AUTO profile the max time of 180 seconds is recommended The motion Sensitivity Range can be set using the Right Dial to set the desired sensitivity Ra