1. LLATION HAS TO BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE ANSI NFPA 70 1999 AND LOCAL CODES IF YOU ARE UNFAMILAR WITH THE METHODS OF INSTALLING ELECTRICAL WIRING SEEK THE SERVICES OFA QUALIFIED LICENSED ELECTRICIAN aireRyder 070420 INSTALLATION INSTRUCTIONS IMPORTANT BEFORE YOU BEGIN INSTALLING THE FAN CAREFULLY READ ALL INFORMATION ON THE SEPARATE SHEET SAFETY INSTRUCTIONS AS WELL AS THE FOLLOWING INSTALLATION INSTRUCTIONS IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN THIS FAN MUST BE INSTALLED WITH A WALL CONTROL SWITCH SAVE ALL INSTRUCTIONS NOTE The fan weight is 25lb 11 4kg Be sure the outlet box you are using is securely attached to the building structure and can support the full weight of the fan Failure to do so can result in serious injury Installation Steps Tighten the hanger bracket to the outlet oa N box with 2 mounting screws To reduce Pa the risk of fire electric shock or personal Outlet Box injury mount to the outlet box marked Han Acceptable for fan support and use ger i g f Bracket yA S5 mounting screws provided with the outlet 7 box Turn OFF the electric power at the main fuse or circuit breaker box Remove the Lock Pin and take off Thread the motor wires through the Insert the Downrod into the Collar the Hanger Pin oe stand cover and Slide Hanger Pin through holes of ownrod Collar and Downro
2. OTE Before installing blade holders to the motor please remove the plastic inserts Attach the rubber clip to cover the slot Connect the two terminals respectively Assembly without fan light from the motor and the switch box Make sure the lead wire of fan light in switch box is sealed with a wire nut exactly Secure the switch box cover with the switch box screws Turn ON the electric power at the 1 The fan switch can switch advances to a new position whenever the switch main fuse or circuit breaker box is pulled The sequence of position is OFF HI MED LOW 2 The slide switch sets direction of fan rotation Push the slide switch down for Forward and up for Reverse aireRyder 070420 PAGE 2 3 Trouble Shooting Guide If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Guide If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Department TROUBLE SUGGESTED REMEDY 1 If fan does not start 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing CAUTION Make sure main power is turned off Make sure forward
3. aireRyder LIMITED LIFETIME WARRANTY Model No FN52307 aireRyder ORIGINAL CEILING FAN LIMITED LIFETIME WARRANTY The limited lifetime warranty covers this ceiling fan for residential use by the original purchaser against defects in material or workmanship as follows If your aireRyder Ceiling Fan motor fails at any time during the lifetime of the original purchaser due to defects in material or workmanship we will provide a replacement part free of charge If your Fan motor fails at any time within one year after the original date of sale to the original purchaser due to defects in material or workmanship we will provide labor to repair the defect with the exception of take down reinstallation free of charge The original purchaser will be responsible for all labor costs after this one year period If no replacement parts are provided for any part of your Fan motor that fails at any time during your lifetime due to defects in material or workmanship we will refund the original purchase price of your Fan If your Fan blades pull chain switch reverse switch or any accessory except glass globes and light bulbs fails at any time within one year after the original date of purchase due to a defect in material and workmanship we will repair or if we choose replace the defective blades switch or accessory free of charge with the exception of take down reinstallation services If the original purchaser ceases to own the Fan this warr
4. anty and any implied warranty including but not limited to any implied warranty of merchantability or fitness for a particular purpose become void This warranty and any implied warranty including but not limited to any implied warranty of merchantability or fitness for a particular purpose do not cover glass globes light bulbs or finish on any metal portions of the Fan This warranty is in lieu of express warranties The duration of any implied warranty of merchantability or fitness for a particular purpose with respect to any aireRyder Ceiling Fan motor blades switch or accessories is expressly limited to the period of the express warranty set forth above for such motor blades switch or accessories This warranty excludes defects malfunctions or failures of any aireRyder Ceiling Fan that are caused by repairs by persons not authorized by us use of parts or accessories not authorized by us mishandling improper installation modifications or damage to the Fan while in your possession or unreasonable use including failure to provide necessary maintenance In no event shall aireRyder Fan be liable for consequential or incidental damages Some states do not allow the exclusion or limitation of consequential or incidental damages in which case the above limitation or exclusion may not apply This warranty gives you specific legal rights and you may also have other rights which vary from state to state aireRyder Package Conte
5. d Hanger Bracket Rubber Sheath Hanger Ball __ _ Insert and tighten the two Collar Thread the motor wires through Hang the fan on hanger bracket Screws Slide Lock Pin into Hanger the rubber sheath then fully and make sure the slot of hanger Pin until it locks into position cover it to the hanger ball ball is snapped into the chip of hanger bracket exactly Note For slope ceiling installation make sure the slot of hanger ball and the chip of hanger bracket is face down aireRyder PAGE 1 3 070420 Make wires connections Measure the length of wire that you need 1 The motor white wire to the white wire from the outlet box with a wire nut 2 The motor black wire and blue wire to the black wire from the outlet box with a wire nut 3 The ground wire from the outlet box to the ground wire from the motor with a wire nut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box After the splices have been made they should be turned upward and pushed carefully up into the outlet box Green Ground Plastic Insert i Motor Screw Secure the canopy to hanger bracket Tighten blades to blade holders by Secure blade holders to the motor with with screws using blade screws and washers motor screws and washers N
6. jects in between rotating fan blades Before changing the fan direction turn off the fan and wait for the fan blades to stop completely f a stationary appliance is not provided with a supply cord and a plug or with other means for disconnection from the mains supply having a contact separation of at least 3 mm in all poles that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules NOTE The safeguards provided by these safety instructions and by the separate installation instructions are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and care are factors which can not be built into this product These factors must be supplied by the person s installing caring for and operating the fan WARNING TO AVOID RISK OF ELECTRIC SHOCK BE SURE TO SHUT OFF POWER AT THE MAIN FUSE OR CIRCUIT BREAKER BOX BEFORE INSTALLING OR SERVICING THIS FIXTURE TURNING OFF THE ELECTRICAL POWER BY USING THE LIGHT SWITCH IS NOT SUFFICIENT TO PREVENT ELECTRICAL SHOCK TO REDUCE THE RISK OF INJURY INSTALL THE FAN SO THAT THE BLADES ARE AT LEAST 7 FEET 2 1 METERS ABOVE THE FLOOR AND AT LEAST 18 INCHES 0 5 METERS FROM THE TIP OF THE BLADES TO THE WALL TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT AND USE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX THE INSTA
7. lades are screwed firmly into blade holders 2 Check that all blade holders are tightened securely to motor 3 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 4 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Keeping measure within 1 8 in rotate the fan until the next blade is positioned for measurement repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor 5 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 1 Check blue wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing 4 If light does not work aireRyder PAGE 3 3 070420
8. nts Unpack your fan and check the contents You should have the following items 1 Hanger Bracket 2 Canopy 3 Downrod Stand Cover 4 Downrod Set Included Hanger Ball 6 in Downrod Hanger Pin amp Lock Pin 5 Fan Fixture Set 6 Blade Holder X5 7 Fan Blade X5 8 Switch Box 9 Assembly Kit Dimension Reference Installed with 6 in Downrod A 16 in B 14in C 2 1 4 in D 10 1 2 in E 5 1 4 in aireRyder 070420 Exploded View Detail Hanger Bracket A n Canopy UA Hanger Ball Downrod Downrod Stand Cover Hanger Pin sl ee RP er Collar Switch Box Triple Mount Drawing SSS a Z7AZ S77 is a Downrod Mount SPH a SS gga eI hws i xC N Slope Ceiling Mount Up to 23 degrees aireRyder 070420 Safety Instructions READ ALL SAFETY INFORMATION AND INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN INSTALLING THE FAN SAVE INSTRUCTIONS All set screws of the fan must be checked and retightened where necessary before installation To reduce the risk of personal injury do not bend the blade brackets when installing the brackets balancing the blades or cleaning fan Do not insert foreign ob
9. reverse switch is firmly in up or down position Fan will not operate when switch is in the middle 4 Make sure that the wall controler is turned ON oO Make sure all screws in motor housing are snug not over tightened Make sure the screws which attach the fan bladeholder to the motor are tight Make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 If using an optional ceiling fan light kit check to be sure the screws securing the glassware are finger tight Check to be sure light bulb is tight in socket and not touching glass shade s If vibration persists from glass remove glass and install a 1 4 in wide rubber band on glass neck to act as an insulator Replace glass and tighten screws against rubber band 5 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 6 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 2 If fan sounds noisy Ww N gt 3 If fan wobbles All blades are weighed and grouped by weight Natural woods vary in density which could cause the fan to wobble even though all blades are weight matched The following procedures should eliminate most of the wobble Check for wobble after each step 1 Check that all b
Download Pdf Manuals
Related Search
Related Contents
野aSaRi 取扱説明書 SEI Rota Capri 61 Leer noticia completa - SiiS Centro de documentación y estudios fulltext Our new Inspiration Dishwasher Range 6020U Controller User manual - Leadingtouch Technology Co., Ltd. PSM-002 User Manual - General Photonics! Tripp Lite 16-Port 1U Rackmount Fiber Optic Patch Panel, ST/ST Copyright © All rights reserved.