Home
Monte Carlo 8ATR44BSD-L Instructions / Assembly
Contents
1. Do Not Remove Knockouts In The Outlet Box Make wiring connections as indicated above White from fan to white from remote marked N Orange from fan to Orange from remote marked Light up Blue from fan to blue from remote marked down light Black from fan to Black from remote marked L White from house to white from remote marked ACN Black from house to Black from remote marked AC L Connect all green ground wires to Ground wire from House Install 1 x 100 watt JD E 11 halogen bulb Do not touch bulb surface as oily residue from skin can cause the bulb to explode Bulb included WARNING Over lamping the fan will re sult in the fan lights shutting down until the proper wattage of bulbs are installed Reset the lights by turning off the wall switch breaker or by remote Re place bulbs with the correct wattage bulbs turn the power on 2011 Monte Carlo Fan Company 3 2 2012 Install glass to fan using the 3 ball Install glass to fan screws provided Remove cover by snaping off from top or bot tom Remove battery cover Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V Attach cover of remote by placing over buttons and snap the battery cover in place Place face plate over battery compartment and buttons Place remote over 2 pins on front cover Attach cover of remote by placing over 4 pins and Snaping into place Attach front cover to wall control wi
2. prominent warning device such as a tag to the service panel Be cautious Read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING To Reduce The Risk Of Fire Electric Shock or Personal Injury Mount To Outlet Box Marked Acceptable for Fan Support of 15 9 kg 35 Ibs or less And Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan must be installed with an isolating wall control switch WARNING To reduce the risk of fire or electric shock this fan
3. If you have more than one fan with remote You can set the dip switches to differ ent positiosns to have seperate control Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Carefully lift fan assembly onto mounting bracket Rotate fan so that the notch on the ball engages the ridge in the mounting bracket This will allow hands free wiring Install remote receiver by sliding into opening in the mounting bracket Make sure that the dip switches on the transmitter and the receiver are set to the same positions Raise the canopy up and align the two holes in the canopy with the two holes in the hanger bracket Secure with two screws provided Sa cable installation 2 Soe 3 lag lock screw washer For Canadian installation and for USA fan and light kit combinations over 35 Ibs in both flush and downrod modes the safety cable must be installed into the house structure beams using 3 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires Note If Installing The Secondary Support Safety Cable in the U S
4. should only be used with fan speed control part no UC7067RC manufac tured by Rhine Electronic Co Ltd WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application Never place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities CAUTION To Reduce the Risk of Electric Shock Disconnect the electrical supply circuit to the fan before installing the light kit All set screws must be checked and tightened where necessary before installation Tools Required for Assembly not included Electrical Tape Phillips Screwdriver Pliers Safety Glasses Stepladder and Wire Strippers Customer Service 800 969 3347 Customer Service Center 7400 Linder Ave Skokie IL 60077 www montecarlofans com 2011 Monte Carlo Fan Company 3 2 2012 iaf jee j m p hnala MAAA ML SSA Before you begin installing the fan Switch power off at Service pa
5. MEOE NE Berane CEILING FAN COMPANY SATR44XXD L Series Fan UL Model No AC 40448 Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE RETAILER NAME MODEL NUMBER RETAILER ADDRESS To register your fixture please visit our website www montecarlotans com 14 3kgs CXS US 31 5 lbs LISTED Total fan weight with light kit Cautions and Warnings WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TQ PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box WARNING Before you begin installing the fan servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a
6. h Showed the most improvement and by trial and error move the clip in and out along the blade to find the position which most improves the wobble E Remove the clip and discard Once the exact position is determined place a weight on bottom of the metal blade holder on its center line Press the weight firmly to ensure it is firmly attached to the blade holder Add more weight as needed to balance 4 If light does not work 1 Check wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs WARNING Over lamping the fan will result in the fan lights shutting down until the proper wattage of bulbs are installed Reset the lights by turning off the wall switch breaker or by remote Replace bulbs with the correct wattage bulbs turn the power on CAUTION Make sure main power is turned off before entering switch housing WARNING Before attempting to replace the fuse make sure the main power is turned off to the fan Replace only with a 3 amp fuse Fuse is inside the canopy on the blue and orange wires to remote receive push and twist the cap to open the fuse case 2011 Monte Carlo Fan Company 3 2 2012 Mar 2012 New format May 2013 Update for CUL regulation
7. nel and lock service disconnecting means to prevent power from being switched on ac cidentally When the service disconnecting means cannot be locked securely fasten a prominent warn ing device such as a tag to the service panel Install 4 x 15 watt cande pedo shape bulbs Ed Tighten both yoke set screws and lock nuts to further secure downrod box is properly installed to the house structure To reduce the risk of fire electric shock or per sonal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs Loosen screw holding half ball and remove pin from downrod Thread wires and safety cable through down rod and insert downrod into motor yoke Install upper glass over downrod onto fan body Insert clevis pin Install the Mountiing Bracket to the Outlet box Use only the screws provided with the outlet box through yoke and downrod and secure with keeper pin see inset Install canopy over downrod Cau tion Replace pin and ball onto down rod 2011 Monte Carlo Fan Company 3 2 2012 Tighen set screw loosened in step 5 Remote Receiver Dip switches Set dip switches on the Remote Transmitter and Remote Receiver to the same settings This must be done so the units will communcate properly If you have other fans you can set to control from one transmitter by setting both receivers the same as the transmitter
8. tallation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trou ble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means can not be locked securely fasten a prominent warning device such as a tag to the service panel Trouble Suggested Remedy 1 If fan does not start 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing 3 Check to make sure the dip switches from the transmitter and receiver are set on the same frequency CAUTION Make sure main power is turned off 2 If fan sounds noisy 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 Some fan motors are sensitive to signals from Solid State
9. th screws provided Snap battery cover in place Attach blade assembly to arms from motor housing using screws and washers provided Tighten screws se curely WALL MOUNT INSTALL Install wall control unit to outlet box using machine screws provided 2011 Monte Carlo Fan Company 3 2 2012 Cer she fap Remote Control Transmitter Features FAN REVERSE Press once to change direction of LED LIGHT MEDIUM SPEED the fan Fanmust be running to reverse HIGH SPEED LOW SPEED FAN OFF SETTING PLIGHT ON OFF SET Turns fan off only SEER ON KER TING AND DIMMER Press and hold to dim light infinitively DOWNLIGHT ON OFF SETTING AND DIMMER Press and hold to dim light infinitely FAN SPEED Depress 1 dot for low speed 2 dots for medium or 3 dots for high To turn fan off press square LIGHT DIMMER To turn light on press light dimmer once quickly To turn off press once quickly while light is on To dim light hold down button light dimmer The light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress rev button allow a few seconds for remote to change rotation direction with fan running 2011 Monte Carlo Fan Company 3 2 2012 Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly ins
10. variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 3 If fan wobbles 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Dynamic balancing involves counter weighting By using a small weight opposite to the point of wobble you can in almost all cases eliminate the wobble The procedure requires much trial and error and a certain amount of patience to achieve the correct position of the counterweight A Determine which fan speed causes the most wobble This will almost always be the highest speed B Turn the fan off Select any one blade and place the balance clip half way between the blade tip and blade holder on the rear edge of the blade Caution Be care ful to stay clear of the blades when running If the clip is not secure injury may re sult from the clip flying off C Turn the fan on Observe if the wobble is better or worse Turn the fan off and move the clip to the next blade Do the same for all blades and note on which blade the clip improves the wobble the most D Place the clip on the blade whic
Download Pdf Manuals
Related Search
Related Contents
MicroLogic PLC 1500 System Penclic Numpad N2 Fujifilm Astia 100 F 135/36 Radiowecker Aastra BluStar 8000i Desktop Media Phone - telefonanlage HP LaserJet M1522 MFP Series User Guide - Hewlett Canon DR-5010C Owner's Manual Manuale Operativo del Paranco Servoassistito Copyright © All rights reserved.
Failed to retrieve file