Home

Sea Gull Lighting 15358B-758 Instructions / Assembly

image

Contents

1. circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing CAUTION Make sure main power is turned off 3 Make sure that shipping stabilizer tabs have been removed from motor 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until t
2. the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade 8 To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs 9 Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades 10 Attach the mounting bracket using only the hardware supplied with the outlet box 11 To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control 12 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application 13 NEVER place a switch where it can be reached from a tub or shower 14 The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 15 Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When th
3. 1590 CUL ENG Owner s Manual Ceiling Fan Installation Instructions Total fan weight with light kit For 1590 Series Fans READ AND SAVE THESE INSTRUCTIONS sea gull lighting D HC 807 1590 CUL ENG Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS 1 Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1996 including fire rated construction 2 Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer 3 After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding con ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 4 Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 5 Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams 6 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 7 Make sure
4. e service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel TOO QUI RED Phillips Screwdriver Wire Cutters Pliers Step Ladder Install the Mountiing Bracket to the Outlet box Before you begin installing the fan Switch power off Before installing this fan make sure the outlet Use only the screws provided with the out at Service panel and lock service disconnecting means box is properly installed to the house structure let box to prevent power from being switched on accidentally To reduce the risk of fire electric shock or per When the service disconnecting means cannot be sonal injury mount to outlet box or supporting locked securely fasten a prominent warning device system acceptable for fan support such asa tag to the sie panel g Mounting must support at least 35 Ibs Install canopy over the downrod Thread wire through downrod with canopy assembled Insert downrod into motor yoke Next insert clevis pin through yoke and down rod and secure with cotter pin see insert Tighten both yoke set screws to further secure downrod HC 807 Carefully lift fan assembly onto mounting bracket Rotate fan so that the notch on the ball engages the ridge in the mounting bracket This will allow hands free wiring White to motor Black to motor Black Blue to Light Gray Blue Purple Gray O P
5. for remote operation Make wire connections as per diagram in fig 10 Connect the white wire from the Receiver to the White or Neutral wire from the power source Connect the black wire from the Receiver to the Black or hot wire from the power source Connect all Green Yellow wires from the fan Downrod and mounting bracket to the Ground wire from the house Connect White motor to White from fan Connect Black motor to Black from fan Connect Blue to light to Blue from fan Connect Gray from remote to gray from fan and Purple from remote to Purple from fan Warning Make sure that all filiments are inside the wire nut connector Attach blade bracket and floating bracket to blade using screws and washers provided Tighen screws securely Repeat this process 4 more times until all blades are assembled j Remove 2 screws as shown Then install brack et for glass fixture using the screws removed earlier see insert HC 807 1590 CUL ENG Install twin circular fluorescent tube to fan Plug ballast into the fluorescent tube Carefully place fluorescent lamp into clips on fan see insert Light control Battery com button k partment Fett Fan on off 7 7 ie Foward reve rse button Fan speed controls Install 9v battery by removing battery _ cover on back of transmitter and connecting to terminals and re install cover FAN SPEED Depress low for low speed med for medium or hi for high To tur
6. he next blade is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 1 Check wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing For Technical Support Call 866 449 2821 HC 807
7. n fan off press fan off f Install finial cap and glass to fitter body Install LIGHT DIMMER To turn light on press light finial nut and tighten dimmer once quickly To turn off press once quickly while the light is on To dim light hold down button light dimmer The light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Press Forward Reverse button Fan will stop and blades will reverse directions HC 807 1590 CUL ENG Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Trouble 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles 4 If light does not work Suggested Remedy 1 Check main and branch circuit fuses or
8. urple Remote receiver Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Check the motor for shipping stabilizers and remove them if they are present The screws washers and motor pads are pre installed to the blade holders Attach blade assembly to motor and tighten screws securely Before installing the remote receiver Make sure the DIP switches in the Transmitter and receiver are set the same Use instrument with a sharp point to move the switches into the proper positions The Remote will not operate if this procedure is not done If interference from outside transmitters or other remote devices is incountered change the dip switch settings on both transmitter and receiver blade brackets Attach blade brackets and floating brackets onto blades Raise the canopy up and align the two holes in the canopy with the two holes in the hanger bracket Secure with two screws provided 1590 CUL ENG Install remote receiver by sliding into opening in the Mounting bracket Make sure that the dip switches on the Transmitter and the Receiver are set to the same position See Fig