Home
Illumine CLI-EMM030819 Installation Guide
Contents
1. 2 THREADED STUD 2 KNURLED KNOB 2 Figure 14 5 Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 14 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod Your fan is now wired to be turned on and off from the fan switch a WARNING To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling 6 Connect the wood ball with chain to the 3 speed switch pull chain Using Your Ceiling Fan 1 Restore electrical power to the outlet box by turning Three Speed the electricity on at the main fuse box 9 Check th naneti eee st Pull HIGH Check the operation of the fan by gently pulling on Ye na the pul chain switch 2nd Pull Medium 3rd Pull Low 3 All fans are shipped from the factory with the at lca ESA reversing switch positioned to the left circulate air 4th Pull OFF downward If airflow is desired in opposite direction turn your fan OFF and wait for the blades to siop turning then slide the reversing switch to the LA EAs right position and turn fan on again 4 The fan blades will turn in the opposite direction and reverse the airflow Reverse Switch Information Your fan model is equipped wi
2. color before they can be engaged Make sure the connector latch closes properly 16 Position the switch housing assembly on the switch housing cover plate and align the holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three switch housing screws supplied Figure 9 NOTE Do not pinch wires between the switch housing assembly and the switch housing plate 17 You have now completed the assembly of your new ceiling fan You can now proceed with hanging and wiring your fan REMOVE SWITCH SWITCH HOUSING COVER PLATE SWITCH ADAPTER SWITCH HOUSING ASSEMBLY SWITCH HOUSING ASSEMBLY CONNECTOR MOTOR HOUSING CONNECTOR Figure 8 SWITCH HOUSING ASSEMBLY SWITGH HOUSING SCREW 3 Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit 44 WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 15 9kg 35 Ibs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician If in doubt The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds If your fan is to replace an existing ceiling tigh
3. G Failure to seat tab In groove could cause damage to electrical wires and possible shock or fire hazard 4s WARNING To avoid possible fire or shock do not pinch wires between the hanger balli downrod assembly and hanger bracket How to Hang Your Ceiling Fan CEILING 2 A AT Piedi Figure 10 TWO SCREWS SUPPLIED WITH OUTLET BOX Figura 11 NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR ELARITY HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY Figure 12 How to Wire Your Ceiling Fan If you feel that you do not have enough electrical wirlng knowledge or experience have your fan Installed by a licensed electrician 1 Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply this may be a bare wire or wire with green colored insulation Securely connect wires with wire connectors supplied Figure 13 eer an WARNING eee a To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation NOTE If you are using an Emerson Light Fixture with your fan see Light Fixture Owner s Manual for wiring 4 WARNING This product is designed to use only those parts supplied with this product and or any accessories
4. READ AND SAVE THESE INSTRUCTIONS 52 Ceiling Fan Owner s Manual Net Weight 25 4 Lbs READ AND SAVE THESE INSTRUCTIONS Safety Instructions A WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in a manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel 1 Read your owner s manual carefully and keep it for future reference 2 Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing 3 Do not put anything into the fan blades while they are turning 4 Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation 1 To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades 2 All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 2011 and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaut
5. d result In personal injury or property damage WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade fianges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades NOTE All setscrews must be checked and re tightened where necessary before installation DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future use Unpacking Instructions A WARNING Do not install or use fan If any part is damaged or missing A WARNING This product fs designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage 1 Check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view illustration HARDWARE CONTENTS Description Quantity Knurled Knobs 8 32 amp Clevis Pin 6 Hairpin Clip 7 10 32 x 25 Slotted Phillips P IEEE Washer Head Blade Screws 16 8 1 4 20 x 5 Round Head Flange Screw Switch Housing Assembly Screws 12 Pull Chain w Wood Ball Blade Balance Ki
6. d with this simple step Turn Off When Not in the Room Ceiling fans coo people not rooms If the room is unoccupied turn off the ceiling fan to save energy 4 WARNING The fan must be hung with at jeast 7 of clearance from floor to blades Figure 10 4 WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 Ibs Use only a U L outlet box listed as Acceptable for Fan Support of 15 9kg 35 Ibs or fess 4 WARNING To reduce the risk of fire electric shock or personai injury mount fan to outlet box marked Acceptable for Fan Support of 15 9kg 35 Ibs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 11 4s WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall beard until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall 2 Carefully lift the fan ana seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 12 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 11 4 WARNIN
7. designated specifically for use with this product by Emerson Electric Co Substitutlon of parts or accessories not designated for use with this product by Emerson Electrie Co could result in personal Injury or property damage 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 13 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 13 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box 4 WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result 3 Screw ihe two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure i4 BLACK ore BLUE aRounp FAN WIRES _ WIRE w LISTED WHITE SUPPLY NEUTRAL GROUND FRM VO A HANGER BRACKET N wile GREEN WIRE F BLACK SUPPLY GROUND FROM HOT ANGER BALL NOTE CEILING COVER Figure 13 OMITTED FOR CLARITY CEILING COVER Z_ LOCKWASHERS
8. ing the blades or cleaning the fan Do not insert forelgn objects in between rotating fan blades BLADE FLANGE Figure 5 FAN BLADE 9 Turn the fan assembly upside down in preparation for mounting the fan blade assemblies NOTE Take care not to scratch fan housing when REE NG installing blades SCREW 5 10 Carefully unscrew each shipping retainers from the motor housing Discard the five screws and shipping retainers Figure 6 11 Attach the flange blade assembly to the motor hub using the two 1 4 20 x 5 round head flange screws supplied Make sure the screws are tightened securely Figure 6 12 Repeat this procedure for the other four blade assemblies 1 4 20 x 5 ROUND HEAD FLANGE SCREWS 2 PER BLADE FLANGE ASSEMBLY Figure 6 13 Remove one of the screws from the switch adapter Retain for future installation Loosen the two remaining screws in the switch adapter for installation of the switch housing cover plate Figure 7 14 Place the switch housing cover plate onto the switch adapter Engage ihe keyholes of the switch housing cover plate by rotating the switch housing cover plate clockwise on the switch adapter Retighten the two screws and reinstall the screw previously removed Tighten all three screws securely Figure 7 15 Engage the connector of the switch housing assembly with the motor connector Figure 8 The two connectors are keyed and color coded and must be mated correctly color to
9. ion against possible electrical shock Electrica installation should be made or approved by a licensed electrician 3 The outlet box and Joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 15 9kg 35 lbs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrictan if in doubt 4 The downred furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended Instructions for the proper method of wirlng your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be Installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson coul
10. ntil it rests on the motor housing Place the ceiling cover over the downrod Be sure that the ceiling cover and the coupler cover are both oriented correctly Figure 3 5 Reinstall the hanger ball Figure 4 on the downrod DOWNROD as follows Route the three 80 motor leads through 5 the hanger ball Position the pin through the two nta i holes in the downrod and align the hanger ball so the lt gt pin is captured in the groove in the top of the hanger ball Pull the hanger bail up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 4 WARNING it is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Fallure to verify that the pin and setscrew are properly installed could result in the fan falling 6 The fan comes with blue black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above too of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 7 Mount blade flange to fan blade using three 10 32 x 25 slotted Phillips washers head screws Figure 4 Figure 5 i ini 10 32 x 25 SLOTTED 8 eee a procedure for the remaining four blades PHIL Toe WASHER HEAD BLADE SCREW 3 4 WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balanc
11. oles in the downrod with the holes in the motor coupler Install the clevis pin and secure with the hairpin clip Figure 2 The clevis pin must go through the holes in the motor coupler and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed 44 WARNING It Is critical that the clevis pin in the motor coupler fs properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed as shown in Figure 2 could result in the fan falling 3 While pulling up on the downrod securely tighten the two setscrews in the motor coupler Li Wire Size A W G Up to 50 ft 14 50 100 ft 12 A WARNING Before assembly your ceiling fan refer to section on proper method of wiring your fan page 9 If you feel you do not have enough wiring knowledge or experience have your fan Installed by a licensed electrician HANGER BALL SETSCREW DOWNROD ae Figure 1 MOTOR COUPLING SETSCREW GLEVIS PIN L CLIP DOWNROD HAIRPIN CLIP COUPLING SETSCREW CLEVIS PIN 4 Make sure the grommet is properly installed in the coupler cover then slide the coupler cover on the downrod u
12. t PACKAGE CONTENTS ari Description Quantity A Fan moor assy O o eomer p ns i Sten Hosa sonny 5 STI NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plastic bag Piace the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly This Manual Is Designed to Make it as Easy as Possible for You to Assemble Instail Operate and Maintain Your Ceiling Fan Tools Needed for Assembly One Phillips head screwdriver One stepladder One 1 4 blade screwdriver One wire stripper One 5 16 open end wrench or pliers Three wire connectors supplied Materials Wiring outlet box and box connectors must be of type required by the local code The minimum wire would be a 3 conductor 2 wire with ground of following size 1 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 1 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 5 2 Separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Align the clevis pin h
13. t fixture turn electricity off at the main fuse box at this time and remove the existing light fixture 4 WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows instali the fan 8 9 feet above the floor for optimal airflow Consult your Emerson Retailer for optional mounting accessories Using the Ceiling Fan Year Round In the summer use the ceiling fan in the counter clockwise direction The airflow produced by the ceiling fan creates a wind chill effect making you feel cooler Select a fan speed that provides a comfortable breeze lower speeds consume less energy In the winter reverse the motor and operate the ceiling fan at low speed in the clockwise direction This produces a gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realize
14. th a 4 position Season Rotation Direction Switch Position 3 speed puil chain switch The operating sequence Summer Counter Clockwise Left is as follows Winter Clockwise Right Maintenance IMPORTANT CARE INSTRUCTIONS f for your Ceiling Fan A WARNING ts i Do not use water when cleaning your ceiling fan It Nel o x Fa ceiling fan is the only could damage the motor or the blades and create the i possibility of an electrical shock When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Accessories 1 Ceiling Fan Light Kits see store or catalog Aa WARNING This product Is designed to use only those parts 3 Downrod Extension Kits see store or catalog supplied with this product and or any accessories designated specifically for use with this product by 2 Ceiling Fan Light Conirols see store or catalog Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage Aa WARNING The use of any other control not specifically approved for this fan could result in fire shock and personal injury 10