Monte Carlo 3TF24BS Instructions / Assembly
Contents
1. L shaped holes in the canopy only part way so that canopy can twist into place Remove the all thread studs from the lower part of the mounting bracket Align the blade and JENE piade plate with castings on motor to at tach blades to motor Install switch housing plate by twist ing plate with key hole slots into place Replace screw removed and tighten the 3 screws securely 2013 Monte Carlo Fan Company 7 1 2013 Connect plug from fan to switch house plug tor to stick it to the switch housing Be sure it is secure paci Black capacitor box needs to be stuck to the switch housing Not being at tached can cause motor noise Remove 3 screws and save to install switch housing 2013 Monte Carlo Fan Company Remove twin adhesive tape from the black capacitor as shown above Install the switch housing using the 3 screws previously removed 7 1 2013 Trouble 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles 4 If light does not work TROUBLE SHOOTING If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Cus tomer Service C
2. MONTECARLO g CEILING FAN COMPANY Owner s Guide and Installation Manual 31F24XX Series Fan UL Model No AC 536 Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE RETAILER NAME MODEL NUMBER RETAILER ADDRESS To register your fixture please visit our website www montecarlotans com 4 88 kgs c UL US 10 74 Ibs Total fan weight LISTED Cautions and Warnings WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TQ PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box WARNING Before you begin installing the fan servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means canno
3. Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires Note If Installing The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box House Black MEM f mu Black White RC C white Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from Fan to White Neutral wire from house Connect Ground leads from mounting bracket and downrod to Ground lead from house Refer to Safety Tips section of manual Next lift the cover ring and install knurled nuts as shown Tighten the knurled nuts securely The canopy should adjust for as irregularity in the ceiling or Outlet OX Make sure the studs protruding from the bottom of the Mounting bracket are in stalled with threads all the way through the bracket Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Flush mount installation Pass leadwires and safety cable through the canopy a Hang assembled fan from the mounting bracket in stalled to ceiling in previous step Make sure the fan is hanging straight Rotate fan u
4. enter at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Suggested Remedy 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing CAUTION Make sure main power is turned off 3 Make sure forward reverse switch is firmly in up or down position Fan will not operate when switch is in the middle 4 Make sure that shipping stabilizer tabs have been removed from motor 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 If using an optional Ceiling Fan Light Kit check to be sure the screws securing the glassware are finger tight Check to be sure light bulb is tight in socket and not touching glass shade s If vibra tion persists from glass remove glass and install a 1 4 wide rubber band on glass neck to act as a
5. n insulator Replace glass and tighten screws against rubber band 5 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 6 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 If this is a downrod mount fan make sure the ridge on mounting bracket engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measure ment Repeat for each blade If all blade levels are not equal you can adjust blade levels by the fol lowing procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is s
6. nstalled to the house structure To reduce tened by at least two points to a structural ceil the risk of fire electric shock or personal injury ing member a loose box will cause the fan to mount to outlet box or supporting system acceptable wabble Use only the screws provided with for fan support Mounting must support at least 35 the outlet box Ibs Before you begin installing the fan Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Downrod s Ne Thread leadwires and safety cable Remove keeper from pin Loosen the 2 set screws in yoke firet anoueh econ cick for downrod to slip into yoke canopy and last the downrod ey ON ee ore On a eS a Install the Tighten the 2 set screws on the Yoke ody Align the hole in the Downrod with the once the downrod is in place hole in the Yoke Insert the Pin through the i Yoke and Downrod until the point appears on the other side 2013 Monte Carlo Fan Company 7 1 2013 Ls Er INN j NX washer lock washer x For Canadian installation and for USA fan and light kit combinations over 35 Ibs in both flush and downrod modes the safety cable must be installed into the house structure beams using 3 lag screws washers and lock washers provided
7. ntil the tab on the Mounting bracket engages the slot on the Downrod Ball This must be done to prevent the fan body from rotating when the blades are in motion Cover Ring Lift Conopy allowing the 2 studs to protrude through the canopy Remove side covers from canopy ex posing 4 holes 2 closed holes and 2 open L shape holes 2013 Monte Carlo Fan Company 7 1 2013 Remove 2 screws in yoke see insert Remove 3 screws with keyhole slots from top of fan Hang fan from mounting bracket by the hands free hook into a closed hole on the edge of the Canopy Note For Canadian mounting refer to Step 10 Install blades and blade plates to motor using the 9 motor screws pro vided Tighten screws securely Place canopy on top of the fan motor allowing the yoke wires and safety cable to pass through the large hole in the center of the canopy Align the 3 larger holes around the center hole with the 3 screws still installed in the fan Install 3 screws re moved into small holes in canopy to make it a flush mount canopy and tighten screws securely Lift fan to mounting bracket aligning the L shape holes with the scresws on the mount ing bracket Turn the fan clockwise to lock in position Install the other two screws and tighten securely Loosen 2 screws with key slots and remove 1 screw without slot from motor plate and save screw Install two screws corresponding with the
8. re or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application Never place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities CAUTION To Reduce the Risk of Electric Shock Disconnect the electrical supply circuit to the fan before installing the light kit All set screws must be checked and tightened where necessary before installation Note Suitable for use in damp locations Tools Required for Assembly not included Electrical Tape Phillips Screwdriver Pliers Safety Glasses Stepladder and Wire Strippers Customer Service 800 969 3347 Customer Service Center 7400 Linder Ave Skokie IL 60077 www montecarlofans com 2013 Monte Carlo Fan Company 7 1 2013 Use metal outlet box suitable for fan support must support 35 Ibs Before attaching fan to Before installing this fan make sure the outlet box is outlet box ensure the outlet box is securley fas properly i
9. t be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious Read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING To Reduce The Risk Of Fire Electric Shock or Personal Injury Mount To Outlet Box Marked Acceptable for Fan Support of 15 9 kg 35 Ibs or less And Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan must be installed with an isolating wall control switch WARNING To reduce the risk of fi
10. till noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 1 Check blue wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing or canopy 2013 Monte Carlo Fan Company 7 1 2013 Mar 2012 New format Jul 2013 Update for CUL regulation
Download Pdf Manuals
Related Search
Related Contents
Hunter 4-in-1 Total Air Protection 1 Der OpenScape Web Client Release 32.0 Software License Key Delivery Infrastructure (LKDI) GNU cfdisk User Manual Service Manual TDS 500B, 600B & TDS 700A Digitizing MANUEL D`UTILISATION Tréso`Syndicat StarTech.com 1S1P Native PCI Express Parallel Serial Combo Card with 16950 UART manual de instrucciones lavadora de ropas ewlt1161fdhwt Copyright © All rights reserved.