1. cULus LISTED for wet location Disassembling your fixture will void the warranty Your fixture is prewired and preassembled for easy installation AWARNING e Read and follow these instructions e Risk of fire electric shock If not qualified consult an electrician e Disconnect power at fuse or circuit breaker before installing or servicing CAUTION e Connect fixture to a 120 volt 60 Hz power source Any other connection voids the warranty e Fixture should be installed by persons with experience in household wiring or by a qualified electrician The electrical system and the method of electrically connecting the fixture to it must be in accordance with the National Electrical Code and local building codes e Fixture designed for wall or eave mount to a junction box only Mount fixture to a grounded recessed mounted standard junction box marked for use in wet locations e Do not mount below 5 feet SAVE THESE INSTRUCTIONS FOR BEST RESULTS e Install light 10 15 feet above the ground e When installing two fixtures on one switch make sure the switch is rated for at least a 1 A inductive load Eave mount NOTE Coverplate mounts to recessed mounted 1 1 2 in 1 1 2 in standard junction boxes Fig 2 Junction box must be an a at least 1 1 2 inch in depth for proper installation for A FO recessed mount application oy SZ YA Round Octagonal 1 Line up the holes on the mounting bracket B with the
2. ACCI N LEGAL YA SEA POR CONTRATO RESPONSABILIDAD ESTRICTA O DE FORMA EXTRACONTRACTUAL INCLUYENDO LA NEGLIGENCIA NI POR TAMPOCO DE LA P RDIDA DE GANANCIAS COOPER LIGHTING TAMPOCO SE HACE RESPONSABLE POR DA OS QUE SURJAN O EST N CONECTADOS CON ESTOS T RMINOS O CON LA FABRICACI N VENTA ENTREGA USO MANTENIMIENTO REPARACI N O MODIFICACI N DE LOS PRODUCTOS DE COOPER LIGHTING O DEL SUMINISTRO DE CUALQUIER PIEZA DE REPUESTO QUE EXCEDA EL PRECIO DE COMPRA DE LOS PRODUCTOS DE COOPER LIGHTING QUE ORIGINAN UN RECLAMO NO SE ACEPTAR N CARGOS POR MANO DE OBRA PARA QUITAR O INSTALAR LOS ACCESORIOS Para obtener el servicio de la garant a comun quese con Cooper Lighting LLC al 1 800 334 6871 presione la opci n 2 para el Servicio al Cliente o por correo electr nico a ConsumerProducts cooperlighting com e incluya la siguiente informaci n e Nombre direcci n y n mero de tel fono e Fecha y lugar de compra e Cat logo y cantidad de la compra e Descripci n detallada del problema Todos los productos devueltos deben estar acompa ados por un N mero de autorizaci n de productos devueltos emitido por la compa a y deben devolverse con flete prepagado Se rechazar todo producto recibido sin un N mero de autorizaci n de productos devueltos desde la compa a Cooper Lighting LLC no se hace responsable por la mercanc a da ada durante el transporte Los productos reparados o reemplazados estar n sujetos a los t rminos de est
3. LIGHTING FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE TERMS OR THE MANUFACTURE SALE DELIVERY USE MAINTENANCE REPAIR OR MODIFICATION OF COOPER LIGHTING PRODUCTS OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE EXCEED THE PURCHASE PRICE OF COOPER LIGHTING PRODUCTS GIVING RISE TO A CLAIM NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES To obtain warranty service please contact Cooper Lighting LLC at 1 800 334 6871 press option 2 for Customer Service or via e mail ConsumerProducts cooperlighting com and include the following information e Name address and telephone number e Date and place of purchase e Catalog and quantity purchase e Detailed description of problem All returned products must be accompanied by a Return Goods Authorization Number issued by the Company and must be returned freight prepaid Any product received without a Return Goods Authorization Number from the Company will be refused Cooper Lighting LLC is not responsible for merchandise damaged in transit Repaired or replaced products shall be subject to the terms of this warranty and are inspected when packed Evident or concealed damage that is made in transit should be reported at once to the carrier making the delivery and a claim filed with them Reproductions of this document without prior written approval of Cooper Lighting LLC are strictly prohibited For assistance call 1 800 334 6871 or e mail us at ConsumerProducts cooper
4. holes on your junction box Using either 2 6 screws or 2 8 screws D depending on size of the holes in your junction box attach the mounting bracket B to your junction box Fig 3 e E J gt A KF O 99 2 Thread fixture wires through coverplate gasket C Fig 4 Junction box COOPER Lighting 3 Connect fixture black wire to house black wire and fixture white wire to house white wire using wire nuts E provided 4 Connect house ground wire and fixture ground wire to the mounting bracket B using the green ground screw on the mounting bracket 5 Attach fixture A to the mounting bracket B using 2 8 x 1 1 4 in screws F provided Be sure no loose wires remain sticking out from underneath the coverplate Insert the decorative screw cover Caps G into the screw holes on the coverplate for a finished appearance Fig 5 6 Apply silicone caulk around the edges of the coverplate to provide a watertight seal from rain and moisture 7 Turn on power at main fuse breaker box TROUBLESHOOTING Problem Cause Solution Light does not No power to the fixture come ON e Check if circuit breaker tripped e Confirm wall switch is ON TURN OFF POWER BEFORE CONTINUING Wiring to the unit is loose e Confirm wiring is properly secured 2 YEAR LIMITED WARRANTY THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXP
5. ALL PRO Instruction Manual Instrucciones Questions Preguntas 1 800 334 6871 ConsumerProducts cooperlighting com A Light fixture B Mounting bracket Accesorio Soporte de montaje E 3 Wire nuts PACKAGING CONTENTS CONTENIDO DEL PAQUETE C Gasket Junta D 2 46 32 x 3 4 in and 2 48 32 x 3 4 in junction box screws use the size that fits your junction box 2 Tornillos 6 32 x 3 4 pulg y 2 tornillos 48 32 x 3 4 pulg para montaje de la caja de conexi n utilice el tama o que mejor se adecue a su caja de conexi n LS ac TTT ae ON F 2 8 32 x 1 1 4 in cover G 2 Decorative screw cover caps 3 Tuercas mounting screws 2 Cubiertas tapatornillos decorativas para alambre 2 Tornillos 8 32 x 1 1 4 pulg de montaje de la cubierta FSL2030L Bronze Bronce A AA S NS FSL2030LW White Blanco ENGLISH lt lt lt WARNING Risk of electric shock Disconnect power at fuse or circuit breaker before installing ITEMS REQUIRED or servicing Purchase separately NOTE Fixture can be wall or eave mounted Fig 1 e Phillips screwdriver e Outdoor weatherproof silicone caulking IMPORTANT SAFETY INSTRUCTIONS When using product basic precautions should always be followed including the following e Heed all warnings including below warnings AND those included on product Save these instructions and warnings For outdoor use only
6. IVA Y REEMPLAZA A TODAS LAS DEM S GARANT AS YA SEAN IMPL CITAS EXPL CITAS O ESTATUTARIAS INCLUIDAS ENTRE OTRAS LAS GARANT AS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN PARTICULAR Cooper Lighting LLC Cooper Lighting garantiza a sus clientes que los productos de Cooper Lighting no presentar n defectos en los materiales y en la fabricaci n durante un per odo de dos a os desde la fecha de compra La obligaci n de Cooper Lighting seg n esta garant a se limita expresamente al suministro de los productos de reemplazo Esta garant a se extiende s lo para el comprador original del producto Un recibo de compra u otra prueba de la fecha de compra original aceptable para Cooper Lighting Esto es necesario para la ejecuci n de la garant a Esta garant a no se aplica a los productos de Cooper Lighting que hayan sido alterados o reparados o que estuvieron sujetos a negligencia abuso mal uso o accidente incluso los da os durante el env o Esta garant a no se aplica a los productos Cooper Lighting no fabricados por Cooper Lighting que hayan sido suministrados instalados o utilizados junto con los productos Cooper Lighting Los da os del producto causados por bombillas de reemplazo corrosi n o decoloraci n de los componentes de lat n no est n cubiertos por esta garant a LIMITACI N DE RESPONSABILIDAD COOPER LIGHTING NO SER RESPONSABLE LEGAL EN NING N CASO DE DA OS INDIRECTOS ACCIDENTALES O RESULTANTES SIN IMPORTAR LA
7. RESS IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE Cooper Lighting LLC Cooper Lighting warrants to customers that for a period of two years from the date of purchase Cooper Lighting s products will be free from defects in materials and workmanship The obligation of Cooper Lighting under this warranty is expressly limited to the provision of replacement products This warranty is extended only to the original purchaser of the product A purchaser s receipt or other proof of date of original purchase acceptable to Cooper Lighting This is required before warranty performance shall be rendered This warranty does not apply to Cooper Lighting products that have been altered or repaired or that have been subjected to neglect abuse misuse or accident including shipping damages This warranty does not apply to products not manufactured by Cooper Lighting which have been supplied installed and or used in conjunction with Cooper Lighting products Damage to the product caused by replacement bulbs or corrosion or discoloration of brass components are not covered by this warranty LIMITATION OF LIABILITY IN NO EVENT SHALL COOPER LIGHTING BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT STRICT LIABILITY OR IN TORT INCLUDING NEGLIGENCE NOR FOR LOST PROFITS NOR SHALL THE LIABILITY OF COOPER
8. a garant a y se inspeccionan al ser empacados El da o evidente y oculto que se provoque durante el transporte se debe informar de inmediato al transportista que realiza la entrega y se debe presentar un reclamo La reproducci n de este documento sin la aprobaci n previa por escrito de Cooper Lighting LLC est estrictamente prohibida Para solicitar ayuda llame al 1 800 334 6871 o env e un correo electr nico a ConsumerProducts cooperlighting com Impreso en China A COOPER Lighting Customer First Center 1121 Highway 74 South Peachtree City GA 30269 www cooperlighting com 2012 Lighting LL 2012 Cooper Lighting LLC 09 12 825 0785
9. accesorio en una caja de empalmes est ndar embutida con puesta a tierra apta para lugares h medos e No instalar por debajo de 1 5 metros 5 pies GUARDE ESTAS INSTRUCCIONES PARA OBTENER LOS MEJORES RESULTADOS e Instale el accesorio a una altura de 3 a 4 6 metros 10 a 15 pies por encima del suelo e Cuando instale dos portal mparas en un nico interruptor aseg rese de que el interruptor est clasificado para por lo menos una carga inductiva 1 A MONTAJE Y CABLEADO DEL ACCESORIO A ADVERTENCIA Riesgo de choque el ctrico Antes de la instalaci n o reparaci n desconecte la alimentaci n el ctrica en el fusible o interrupto autom tico NOTA El accesorio puede ser montado en la pared o el alero Fig 1 Montaje de alero NOTA La cubierta se adapta a las cajas el ctricas empotradas Fig 2 La caja el ctrica debe tener Tole 2 pulg 1 17 pu una profundidad m nima de 1 1 2 pulg 3 81 cm a 3 para asegurar una instalaci n adecuada en to Loy aplicaciones empotradas sZ YI Redonda Octagonal 1 Alinee los agujeros en la soporte de montaje B con los agujeros en su caja de conexiones Usando ya sea 2 tornillos N 6 2 tornillos N 8 D dependiendo del tama o de los agujeros en la caja de conexiones fije la soporte de montaje a la caja de conexiones Fig 3 2 Pase los cables del artefacto a traves de la junta de la placa de cubierta C Fig 4 Ca
10. ja de conexi nes 3 Conecte el alambre negro del accesorio al alambre negro de la casa el alambre blanco del accesorio al alambre blanco de la casa usando las tuercas para alambre E suministrados 4 Conecte el cable a tierra de la casa y el del accesorio al soporte de montaje AA utilizando el tornillo verde de puesta a tierra del soporte de montaje 5 Fije el accesorio al soporte de montaje utilizando los 2 tornillos N 8 x 31 75 mm 1 1 4 pulg provistos Aseg rese de que no queden cables sueltos a la vista por debajo de la placa protectora Introduzca las cubiertas tapatornillos decorativas en los orificios de los tornillos de la placa protectora para lograr el toque final de terminaci n Fig 5 6 Aplique sellador de silicona alrededor de los bordes de la placa de cierre y en todos los agujeros para formar un sello impermeable a la lluvia y humedad 7 Active la fuente de alimentaci n en la caja de fusibles interruptor autom tico DIAGNOSTICO Y SOLUCION DE PROBLEMAS Problem Cause Solution La luce no se enciende No llega electricidad al portal mparas e Revise si el interruptor de circuito ha saltado e Confirme que el interruptor de pared est encendido DESCONECTE LA CORRIENTE ELECTRICA ANTES DE CONTINUAR El cableado hacia la unidad est flojo e Confirme que el cableado est correctamente asegurado GARANTIA LIMITADA DE 2 A OS LA SIGUIENTE GARANT A ES EXCLUS
11. lighting com Printed in China ARTICULOS NECESARIOS se compran por separado e Destornillador en cruz Phillips e Calafateo de silicona resistente a la intemperie INSTRUCCIONES IMPORTANTES DE SEGURIDAD Al utilizar el producto siempre se deben seguir las precauciones b sicas inclu do lo siguiente e Tenga en cuenta todas las advertencias incluyendo las advertencias a continuaci n Y aquellas incluidas en el producto Guarde estas instrucciones y advertencias S lo para uso en exteriores cULus para ubicaciones mojadas Desensamblar la l mpara anular la garant a La l mpara es percableada y ensamblado para facilitar la instalaci n A ADVERTENCIA e Lea y siga estas instrucciones e Riesgo de fuego descarga el ctrica Si no est capacitado consulte a un electricista e Antes de instalar o dar mantenimiento desconecte el suministro el ctrico en la caja de fusibles o interruptores PRECAUCI N e Conecte el portal mparas a una fuente de energ a de 120 Voltios 60 Hz Cualquier otro tipo de conexi n anula la garant a e El portal mparas debe ser instalado por personas con experiencia en cableado dom stico o por un electricista calificado El sistema el ctricoy el m todo de conexi n el ctrica del portal mparas debe cumplir con el C digo el ctrico nacional y los c digos locales sobre edificios e El accesorio dise ado para la pared o el montaje del alero a una caja de conexiones solamente Instale el
Download Pdf Manuals
Related Search
Related Contents
OPERATORS/SERVICE MANUAL TC-100 “COMMANDER” Operations Manual ICC ICMPPTF242 patch panel TAFCO WINDOWS NU2-179S-I Installation Guide もくじ 高さ調節付浴槽台R “かるぴったん”シリーズ 取扱説明書 OU Campus End-User Manual - Palm Beach State College Speciální funkce NX-5200 NX-5300 NX-5400 Speech and Language Therapy Department Fibre KX-TD7690 Copyright © All rights reserved.