Home

All-Pro MS34W Instructions / Assembly

image

Contents

1. A COOPER Lighting Instruction Manual Instrucciones Questions Preguntas 1 800 334 6871 ConsumerProducts cooperlighting com PACKAGING CONTENTS CONTENIDO DEL PAQUETE A Motion detector and light fixture Detector de movimiento y artefacto de luz D 2 6 and 2 8 mounting screws MS34 Black MS34W White ITEMS REQUIRED Purchase separately e Phillips screwdriver e Hammer e Outdoor weatherproof silicone caulking e 2 150 watt MAX PAR 38 floodlight bulbs NOTE This fixture was designed to work with up to 150 watt maximum PAR halogen flood bulbs For improved energy efficiency lower wattage PAR halogen flood bulbs may be used Compact Fluorescent CFL bulbs contain electronics which may interfere with the motion sensing function of your fixture and are not recommended HOW IT WORKS Your motion activated floodlight senses heat images from objects such as people large animals and automobile engines When motion is detected the lights will automatically turn on Once motion has stopped the lights will turn off after a preselected time d
2. e Aseg rese de que el sensor no est reaccionando a objetos m viles tales como rboles tr fico etc e Si este es el caso disminuya la sensibilidad e Cambie la posici n del sensor de movimiento Las Luces Se Encienden Durante La Noche Y No Se Apagan La luz proveniente de la propia l mpara de la unidad est afectando al sensor de movimiento e Cambie la direcci n de la l mpara e Cambie la posici n del sensor de movimiento Las Luces Se Encienden Y Se Apagan Continuamente Durante La Noche Las Luces Se Encienden Durante El Dia El interruptor en la parte inferior del detector de movimiento se encuentra en el modo de prueba e Consulte la secci n Operaci n del Accesorio Hay sombra sobre el detector de movimiento e Cambie la posici n del sensor de movimiento No Se Puede Activar La Configuraci n de La L mpara de Alta Intensidad Anular La luz ambiental exterior es demasiado brillante Si es asi para la unidad es de d a e Redirija el cabezal e Cambie la ubicaci n de la unidad o dirijala en direcci n contraria a la luz No se dej pasar suficiente tiempo para que el accesorio entrara en el modo de amanecer atardecer e APAGUE OFF ENCIENDA ON APAGUE OFF y ENCIENDA ON la corriente en menos de 2 segundos GARANTIA LIMITADA DE 2 A OS LA SIGUIENTE GARANT A ES EXCLUSIVA Y REEMPLAZA A TODAS LAS DEM S GARANT AS YA SEAN IMPL CITAS EXPL CITAS O ESTATUTARIAS INCL
3. desconecte la alimentaci n el ctrica en el fusible o interrupto autom tico NOTA El accesorio puede ser montado en la pared o el alero NOTA La placa de cubierta se adapta a las cajas el ctricas empotradas Fig 2 La caja el ctrica debe tener una profundidad m nima de 3 81 cm 1 1 2 in para asegurar una instalaci n adecuada en aplicaciones empotradas 1 Apague la electricidad desde la caja de fusibles interruptores autom ticos principal 2 Haga que agujeros de los tornillos de la placa de la cubierta del portal mparas coincidan con los agujeros de los tornillos de la caja de empalmes 3 Pase los cables del portal mparas a trav s de la junta de la placa de cubierta B Fig 3 4 Conecte el cable negro del accesorio al cable negro de la caja y el cable blanco del accesorio al cable blanco de la caja utilizando las tuercas para alambre proporcionadas Fig 3 No se requiere un cable de toma a tierra Una cualquier cable de toma a tierra de su casa a la caja de empalmes 5 Sujete el portal mparas a la caja de empalmes con los dos tornillos adjuntos 6 Aplique calafateo de silicona alrededor de los bordes de la placa de cubierta a fin de proveer un cierre que sea estanco para la lluvia y la humedad 7 Inserte juntas C en el conjunto del portal mparas firmemente contra el portal mparas y enrosque las l mparas en cada portal mparas Fig 3 No apriete demasiado los focos 8 Encienda la
4. aim the lamp Off At Night e Reposition motion sensor Light Is On During The Day The switch on the bottom of the motion sensor is in the test T mode e Refer to OPERATING YOUR FIXTURE The motion detector is shadowed e Reposition motion sensor Surrounding external ambient light is too bright If so the unit may think it is daytime e Re aim the head e Relocate or reposition the unit away from the light Not enough time is allowed to enter the dusk to dawn mode e Turn power OFF ON OFF ON within 2 seconds Cannot Activate Standard Floodlight Setting Override 2 YEAR LIMITED WARRANTY THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE Cooper Lighting LLC Cooper Lighting warrants to customers that for a period of two years from the date of purchase Cooper Lighting s products will be free from defects in materials and workmanship The obligation of Cooper Lighting under this warranty is expressly limited to the provision of replacement products This warranty is extended only to the original purchaser of the product A purchaser s receipt or other proof of date of original purchase acceptable to Cooper Lighting This is required before warranty performance shall be rendered This warranty does not apply to Cooper Lighting products tha
5. con otra del mismo vataje o m s bajo que el indicado Si instala bombillas de mayor potencia puede crear riesgo de incendio Si usa bombillas de mayor potencia se anular la garant a e Para un funcionamiento y protecci n adecuados contra posibles da os los botones de ajuste de la cabeza del sensor de movimiento se deben ajustar en direcci n al piso e UTILICE CONDUCTORES DE SUMINISTRO QUE SOPORTEN UN M NIMO DE 90 C e Si desarma el artefacto se anula la garant a GUARDE ESTAS INSTRUCCIONES PARA OBTENER LOS MEJORES RESULTADOS e Instale el sensor de movimiento transmisor a 2 45 3 65 m 8 12 pies de altura sobre el suelo por encima de 3 65 m 12 pies el sensor de movimiento es menos sensible e Coloque el portal mparas de manera que se mueva por toda la zona de detecci n Fig 1 e Coloque el sensor lejos de fuentes que produzcan calor a fin de evitar falsos disparos Adem s medida de lo posible tenga mucho cuidado de no incluir objetos tales como ventanas paredes blancas y agua en la zona de detecci n e Coloque el sensor lejos de objetos m viles como por ejemplo rboles arbustos grandes y tr fico callejero e No instale m s de una l mpara de alta intensidad activada por movimiento en un mismo interruptor de pared o circuito ya que esto puede crear interferencia entre los accesorios MONTAJE Y CABLEADO DEL ACCESORIO ADVERTENCIA Riesgo de choque el ctrico Antes de la instalaci n o reparaci n
6. el ltimo movimiento 5 segundos a 12 minutos Fig 6 Modo de Adjuste de la perilla funcionamiento de MODO Ajuste Autom tico 5 segundos activado por movimiento a La l mpara debe encenderse 12 minutos con movimiento s lo en la noche y debe apagarse y encenderse de acuerdo con el nivel de luz seleccionado por la perilla de ajuste de luz Fig 2 3 81 cm 3 81 cm e rail a SITO D 3 Redonda Octagonal a ao 4 lt Q TAR har _ e Sot JS N sn J N SN S L a J I N xs N EY Montaje de alero Como adjustar interruptor electrico Mantenga la alimentaci n del portal mparas activada Como adjustar interruptor electrico Modo de Adjuste de la perilla funcionamiento de MODO Ajuste Est ndar de Una Cualquier posici n L mpara de Alta Intensidad Las luces deben permanecer encendidas continuamente durante el d a y la noche se debe ajustar a mano Apague la corriente y enci ndala una vez por el interruptor de pared dentro de 2 segundos para ajustar de nuevo a modo de control manual Ap guela por 10 segundos para reajustar a modo autom tico Ajuste de Prueba TEST Las luces deben encenderse Ambas perillas en el T por el movimiento tanto en el d a como en la noche Las luces deben apagarse despu s de 4 segundos Mantenga la alimentaci n del portal mparas activada DIAG
7. off power at main fuse breaker box 2 Match up screw holes on the floodlight coverplate Fig 3 with the junction box screw holes 3 Thread fixture wires through coverplate 0 pan B Fig 3 E LA e 0 4 Connect fixture black wire to house black wire a y and connect fixture white wire to house white wire PV gt using wire nuts E provided Fig 3 No ground 7 wire is required Attach any ground wire from your NO house to junction box 5 Attach fixture A to the junction box with two aaa mounting screws D provided O EA PS 6 Apply silicone caulk around the edges of the YO coverplate to provide a watertight seal from rain ra 7 ke pa and moisture LY amp WC 7 Insert lampholder gaskets C into lampholder 7 Am n assembly tightly against lampholder and screw Nea bulbs into each lampholder Fig 3 Do not Eave mount overtighten bulbs S COOPER Lighting 8 Turn power on at main fuse breaker box 9 Aim sensor head in desired position NOTE Maintain air spacing between lamps and sensor head at least 1 inch Make sure sensor head is positioned with control switches facing towards the ground OPERATING YOUR FIXTURE 1 Rotate both knobs on bottom of the sensor to T test Fig 4 2 Turn on fixture at wall switch Allow fixture to warm up approximately 1 minute before testing Light will come on and stay on during warm up period 3 Readjust sensor head up down left or r
8. DO LA NEGLIGENCIA TAMPOCO DE LA P RDIDA DE GANANCIAS COOPER LIGHTING TAMPOCO SER RESPONSABLE DES O DA OS QUE SURJAN O EST N CONECTADOS CON ESTOS T RMINOS O CON LA FABRICACI N VENTA ENTREGA USO MANTENIMIENTOM REPARACI N O MODIFICACI N DE LOS PRODUCTOS DE COOPER LIGHTING O DEL SUMINISTRO DE CUALQUIER PIEZA DE REPUESTO QUE EXCEDA EL PRECIO DE COMPRA DE LOS PRODUCTOS DE COOPER LIGHTING ORIGINANDO UN RECLAMO NO SE ACEPTAR N CARGOS POR MANO DE OBRA PARA QUITAR O INSTALAR LOS ACCESORIOS Para obtener el servicio de la garant a comun quese con Cooper Lighting LLC al 1 800 334 6871 presione la opci n 2 para el Servicio al Cliente o por correo electr nico a ConsumerProducts cooperlighting com e incluya la siguiente informaci n e Nombre direcci n y n mero de tel fono e Fecha y lugar de compra e Cat logo y cantidad de la compra e Descripci n detallada del problema Todos los productos devueltos deben estar acompa ados por un N mero de autorizaci n de productos devueltos emitido por la compa a y deben devolverse con flete prepagado Se rechazar todo producto recibido sin un N mero de autorizaci n de productos devueltos desde la compa a Cooper Lighting LLC no se hace responsable por la mercanc a da ada durante el transporte Los productos reparados o reemplazados estar n sujetos a los t rminos de esta garant a y se inspeccionan al ser empacados El da o evidente y oculto que se provoque durante el tran
9. NOSTICO Y SOLUCION DE PROBLEMAS Problema Causa Posible Acci n Correctiva Las Luces No llega electricidad al bombilla Exteriores No Se e Revise si el interruptor de circuito ha saltado Encienden Durante Confirme que el interruptor de pared est encendido La Noche Aunque La bombilla est defectuoso Haya Movimiento e Cambie la bombilla La luz ambiental exterior es demasiado brillante Si es asi para la unidad es de d a e Redirija el cabezal e Cambie la ubicaci n de la unidad o dirijala en direcci n contraria a la luz DESCONECTE LA ENERG A ANTES DE CONTINUAR El cableado hacia la unidad est flojo e Revise los cables y vu lvalos a conectar si fuera necesario usando las tuercas E que se incluyen Hay movimiento en la zona de detecci n e Aseg rese de que el sensor no est reaccionando a objetos m viles tales como rboles tr fico etc COMPRU BELO USTED MISMO e Cubra la lente del sensor con la cinta aislante negra para evitar que detecte movimiento y tambi n cubra la foto celda en la base de la cabeza del detector Si la luce permanecen apagado hay algo en el rea de detecci n que est activando el sensor e Cambie la posici n del sensor de movimiento Si las luces permanecen encendidas con la lente del sensor cubierta p ngase en contacto con el servicio de asistencia al cliente Las Luces Exteriores Se Enciended Durante La Noche Sin Motivo Aparente Hay movimiento en la zona de detecci n
10. UIDAS ENTRE OTRAS LAS GARANT AS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN PARTICULAR Cooper Lighting LLC Cooper Lighting garantiza a sus clientes que los productos de Cooper Lighting no presentar n defectos en los materiales y en la fabricaci n durante un per odo de dos a os desde la fecha de compra La obligaci n de Cooper Lighting seg n esta garant a se limita expresamente al suministro de los productos de reemplazo Esta garant a se extiende s lo para el comprador original del producto Un recibo del comprador u otra prueba de la fecha de compra original aceptable para Cooper Lighting Esto es necesario para la ejecuci n de la garant a Esta garant a no se aplica a los productos de Cooper Lighting que hayan sido alterados o reparados o que estuvieron sujetos a negligencia abuso mal uso o accidente incluso los da os durante el env o Esta garant a no se aplica a los productos Cooper Lighting no fabricados por Cooper Lighting que hayan sido suministrados instalados o utilizados junto con los productos Cooper Lighting Los da os del producto causados por bombillas de reemplazo corrosi n o decoloraci n de los componentes de lat n no est n cubiertos por esta garant a LIMITACI N DE RESPONSABILIDAD COOPER LIGHTING NO SER RESPONSABLE LEGAL EN NING N CASO DE DA OS INDIRECTOS ACCIDENTALES O RESULTANTES SIN IMPORTAR LA ACCI N LEGAL YA SEA POR CONTRATO RESPONSABILIDAD ESTRICTA O DE FORMA EXTRACONTRACTUAL INCLUYEN
11. be accompanied by a Return Goods Authorization Number issued by the Company and must be returned freight prepaid Any product received without a Return Goods Authorization Number from the Company will be refused Cooper Lighting LLC is not responsible for merchandise damaged in transit Repaired or replaced products shall be subject to the terms of this warranty and are inspected when packed Evident or concealed damage that is made in transit should be reported at once to the carrier making the delivery and a claim filed with them Reproductions of this document without prior written approval of Cooper Lighting LLC are strictly prohibited For assistance call 1 800 334 6871 or e mail us at ConsumerProducts cooperlighting com Printed in China ART CULOS NECESARIOS se compran por separado e Destornillador en cruz Phillips e Martillo e Calafateo de silicona resistente a la intemperie e 2 l mparas para proyector tipo PAR 38 de 150 W m ximo NOTA Este accesorio fue dise ado para trabajar con bombillas reflectoras de Hal geno PAR de 150 vatios como m ximo Para mayor eficiencia de energ a use bombillas reflectoras Hal geno PAR de menor vataje No se recomienda el uso de bombillas fluorescentes compactas CFL porque tienen partes electr nicas que pueden interferir con las funciones de detecci n de movimiento de su accesorio C MO FUNCIONA La l mpara de alta intensidad activada por movimiento Hasta detecta im genes t
12. elay Your motion activated floodlight may also be used as a standard floodlight WARNINGS AND CAUTIONS e Read these instructions e Keep these instructions e Heed all warnings e Follow all instructions e For outdoor use only e cULus LISTED for wet locations 110 degrees e Connect fixture to a 120 volt 60 Hz power source Any other connection voids the warranty e Fixture should be installed by persons with experience in household wiring or by a qualified electrician The electrical system and the method of electrically connecting the fixture to it must be in accordance with the National Electrical Code and local building codes e Fixture should be mounted to a grounded recessed mounted standard junction box marked for use in wet locations i e NOT suitable for ground mount installation e Keep away from flammable objects Do not position fixture within two inches of any combustible materials e Always replace bulb with the same wattage or lower wattage than included Installing a bulb of a higher wattage could create a fire hazard Use of a higher wattage bulb will void the warranty e Do not allow sensor head to touch light housing maintain at least 1 inch space between fixture and sensor e For proper operation and protection against damage the motion sensor head adjustment knobs must be facing the ground e MINIMUM 90 C SUPPLY CONDUCTORS B Coverplate gasket Junta de la placa de cubierta C 2 Lam
13. electricidad desde la caja de fusibles interruptores autom ticos 9 Oriente el cabezal sensor en la posici n deseada NOTA Deje un espacio de aire de por lo menos 2 54 cm 1 pulg entre las l mparas y el sensor Aseg rese de que la cabeza del sensor est colocada con los interruptores de control en direcci n al piso OPERACI N DEL ACCESORIO 1 Gire la perilla ubicada en la parte trasera del sensor a la posici n T Test Prueba Fig 4 2 Encienda el accesorio Permita que la l mpara se caliente durante aproximadamente 1 minuto antes de probar La l mpara se encender y permanecer encendida durante el per odo de calentamiento 3 Ajuste la sensibilidad hasta obtener los resultados deseados Para un alcance mayor apunte el sensor ligeramente hacia arriba Para un alcance menor apunte el sensor ligeramente hacia abajo 4 Gire la perilla de la luz hacia la ubicaci n deseada Gir ndola m s cerca del s mbolo de luna para que la luz se encienda con movimiento en la noche o g rela m s cerca de la T para que la luz se encienda con movimiento durante las horas del anochecer NOTA Aseg rese de no moverse mientras espera a que se apaguen las luces de lo contrario el sensor de movimiento mantendr encendida la l mpara 5 Una vez que se apague la luz mueva los controles de ajuste a la cantidad de tiempo de espera deseada El reflector per manecer encendido despu s que se detecta
14. ight until desired detection area is achieved 4 Turn sensitivity light knob to desired location Turn knob closer to moon symbol for light to turn on with motion at night or turn closer to T for light to start detecting motion at dusk Fig 5 NOTE Make sure you stand motionless while you wait for the lights to turn off otherwise the motion sensor will keep the light fixture on 5 Once the light fixture goes off move the time adjustment controls to the desired length of time The floodlight will remain on after the last motion is detected 5 seconds to 12 minutes Fig 6 SELECTING YOUR DESIRED FEATURE Mode of MODE Knob How to Set Operation Adjustment Power Switch Auto Setting 5 seconds Keep the power motion activated to to the fixture ON Lights should turn ON with 12 minutes motion only at night and on according to the time level selected by the time adjustment knob Standard Floodlight Setting Lights should stay ON continuously both day and night must be reset manually Turn power OFF and turn power ON once by wall switch within 2 seconds to set back to Manual Override Mode Turn OFF for 10 seconds to reset to Auto Mode Any position Test Setting TEST Lights should turn ON with Both knobs at T motion both day and night Lights should turn OFF after 4 seconds Keep the power to the fixture ON TROUBLESHOOTING Problem Cause S
15. olution Light Does Not No power to the fixture Come On With e Check if circuit breaker tripped Motion At Night e Confirm wall switch is ON Bulb is faulty e Replace bulb Surrounding external ambient light is too bright If so the unit may think it is daytime e Re aim the head e Relocate or reposition the unit away from the light TURN OFF POWER BEFORE CONTINUING Wiring to the unit is loose e Check wiring and reconnect if necessary using wire nuts E provided Problem Cause Solution Light Comes On For No Apparent Reason At Night There is motion in the detection zone e Make sure the sensor is not picking up moving objects such as trees traffic etc TEST FOR YOURSELF e Cover the sensor lens with cardboard to prevent sensor from detecting motion and cover the photocell on the bottom of the sensor head If the light stays off something in the detection zone is triggering the sensor e Reposition the sensor If the light stays on with the sensor lens covered contact customer service Light Stays On At There is motion in the detection zone Night And Does e Make sure the sensor is not in Manual Override Mode Not Turn Off e Make sure the sensor is not picking up moving objects such as trees traffic etc e Reposition the sensor Light The light given from the unit s own lamp is affecting the photo Continuously eye in sensor Light could be reflecting off of nearby surface Blinks On and e Re
16. pholder gaskets 2 Juntas obturadoras del recept culo E 2 Wire nuts 2 Tuercas para alambre Ap use the size that fits your junction box 2 Tornillos 6 y 2 tornillos 8 de montaje utilice el tama o que mejor se adecue a su caja de conexi n e Disassembly of your fixture will void the warranty SAVE THESE INSTRUCTIONS FOR BEST RESULTS e Install the motion sensor transmitter 8 12 feet above the ground Motion sensor is less sensitive above 12 feet e Locate motion sensor so motion moves across detection zone Fig 1 e Locate sensor away from heat producing sources to prevent false triggering Also be very careful not to include objects such as windows white walls and water in the detection zone e Locate sensor away from moving objects such as trees large shrubs and street traffic e Do not install more than one motion activated floodlight on one wall switch or the same circuit since this may cause interference between fixtures MOUNTING AND WIRING YOUR FIXTURE WARNING Risk of electric shock Disconnect power at fuse or circuit breaker before installing Fig 2 O 1 1 2 inch 1 1 2 inch NOTE Fixture can be wall or eave mounted sr rat NOTE Coverplate mounts to recessed mounted FO standard junction boxes Fig 2 Junction box must be Qu at least 1 1 2 inch in depth for proper installation for Z 7 recessed mount application Round Octagonal 1 Turn
17. rmicas de objetos tales como 60 pies personas animales grandes y motores de autom viles Cuando se detecte movimiento la luz se encender MINS autom ticamente Una vez que el movimiento haya AA SS cesado la luz se apagar despu s de un tiempo de 7 4 a 7 retardo preseleccionado Esta l mpara de alta intensidad nN D ee activada por movimiento tambi n puede ser utilizada 110 grados como una l mpara de alta intensidad est ndar ADVERTENCIAS Y PRECAUCIONES e Lea estas instrucciones e Guarde estas instrucciones e Atienda todas las advertencias e Siga todas las instrucciones e S lo para uso en exteriores e CULus para ubicaciones mojadas e Conecte el accesorio a una fuente de energ a de 120 voltios y 60 Hz Cualquier otro tipo de conexi n anular la garant a e El portal mparas debe ser instalado por personas con experiencia en cableado dom stico o por un electricista calificado El sistema el ctricoy el m todo de conexi n el ctrica del portal mparas debe cumplir con el C digo el ctrico nacional y los c digos locales sobre edificios e El accesorio se debe conectar a una caja de empalmes empotradas con toma de tierra marcada para usar en lugares h medos e No es adecuado para instalarse mont ndolo en el suelo e Mant ngalo alejado de objetos inflamables No coloque el artefacto en posici n dentro de dos pulgadas 5 cm de cualquier material combustible e Reemplace siempre la bombilla
18. sporte se debe informar de inmediato al transportista que realiza la entrega y se debe presentar un reclamo La reproducci n de este documento sin la aprobaci n previa por escrito de Cooper Lighting LLC est estrictamente prohibida Para solicitar ayuda llame al 1 800 334 6871 o env e un correo electr nico a ConsumerProducts cooperlighting com Impreso en China O COOPER Lighting Customer First Center 1121 Highway 74 South Peachtree City GA 30269 www cooperlighting com 2010 Cooper Lighting LLC 10 10 825 0563
19. t have been altered or repaired or that have been subjected to neglect abuse misuse or accident including shipping damages This warranty does not apply to products not manufactured by Cooper Lighting which have been supplied installed and or used in conjunction with Cooper Lighting products Damage to the product caused by replacement bulbs or corrosion or discoloration of brass components are not covered by this warranty LIMITATION OF LIABILITY IN NO EVENT SHALL COOPER LIGHTING BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT STRICT LIABILITY OR IN TORT INCLUDING NEGLIGENCE NOR FOR LOST PROFITS NOR SHALL THE LIABILITY OF COOPER LIGHTING FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE TERMS OR THE MANUFACTURE SALE DELIVERY USE MAINTENANCE REPAIR OR MODIFICATION OF COOPER LIGHTING PRODUCTS OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE EXCEED THE PURCHASE PRICE OF COOPER LIGHTING PRODUCTS GIVING RISE TO A CLAIM NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES To obtain warranty service please contact Cooper Lighting LLC at 1 800 334 6871 press option 2 for Customer Service or via e mail ConsumerProducts cooperlighting com and include the following information e Name address and telephone number e Date and place of purchase e Catalog and quantity purchase e Detailed description of problem All returned products must