Home
All-Pro MS185D Instructions / Assembly
Contents
1. A COOPER Lighting Instruction Manual Instrucciones Questions Preguntas 1 800 334 6871 ConsumerProducts cooperlighting com RAN PRECISION PLUS A Motion detector and light fixture Junta de la placa Detector de de cubierta movimiento y artefacto de luz E 3 Wire nuts 3 Conectores de cable pa pn MS185D Bronze PACKAGING CONTENTS CONTENIDO DEL PAQUETE B Coverplate gasket F y D 2 6 and 2 48 mounting screws use the size that fits your junction box 2 Tornillos 6 y 2 tornillos 48 de montaje utilice el tama o que mejor se adecue a su caja de conexi n C 2 Lampholder gaskets 2 Juntas obturadoras del recept culo CODEC Color matched G Mounting plate H Mounting bracket center hole plug screw Soporte de montaje Tapon para agujero Tornillo para la central de color placa de montaje MS185DW White CAUTION e Connect fixture to a 120 volt 60 Hz power source Any other connection voids the warranty ITEMS REQUIRED e Fixture must be mounted to a grounded recessed junction box marked for use Purchase separately in wet locations e Phillips screwdriver e Outdoor weatherproof silicone caulking e 2 100 watt MAX PAR 38 floodlight bulbs b b NOTE This fixture was designed to work with up to 150 watt maximum PAR halogen flood bulbs For improved energy efficiency lower wattage PAR halogen flood bulbs may be used Compact Fluorescent
2. Line up the holes on the mounting bracket H with the holes on your junction box Using either 2 6 screws or 2 8 screws D depending on size of the holes in your junction box attach the mounting bracket H to your junction box Fig 4 3 Thread fixture wires through coverplate gasket B and position gasket B on the coverplate 4 Connect the black wire from the fixture A to the black house supply wire and the white wire from the fixture A to the white supply wire using the wire nuts E provided Attach the ground wire coming from your house to the copper ground wire from the fixture A using wire nut E provided If no house ground wire is available attach the copper ground wire from the fixture A to the junction box if it is metal and grounded If junction box is not metal and no house ground wire is available an alternative ground source must be used for safe operation Fig 5 5 Attach fixture A to the mounting bracket H using the center bolt G provided Be sure no loose wires remain sticking out from underneath the coverplate Insert plastic color matched plug F in center bolt hole for finished appearance Fig 6 6 Apply silicone caulk around the edges of the coverplate to provide a watertight seal from rain and moisture 7 Insert lampholder gaskets C into lampholder assembly tightly against lampholder and screw bulbs into each lampholder Fig 7 Do not overtighten bulbs 8 Turn on p
3. de pared Montaje de alero detector Ajustar el ngulo cambiar el rea de detecci n Aqu hay algunas directrices para ayudarle a programar la unidad e Un buen rango para colocar el accesorio es de 8 2 45 m a 123 65 m por arriba del suelo e Para el montaje a una altura de 8 2 45 m colocar el detector a un ngulo de 5 debajo del nivel horizontal debe funcionar bien para la mayor a de las ubicaciones Fig 10 e Si el accesorio se monta muy arriba el ngulo debajo del nivel horizontal del detector deber ser mayor 5 Camine por la zona de detecci n hasta la distancia m s lejana que usted desea que el detector detecte movimiento 6 Ajuste la perilla de SENSITIVITY hasta que obtenga los resultados deseados Para un rango mayor oriente ligeramente el detector hacia arriba Para un rango menor oriente la cabeza del detector ligeramente hacia abajo Las luces se apagar n 4 segundos despu s de que ya no haya movimiento 7 Ajuste la perilla de MODO Auto autom tico a una selecci n de tiempo entre 1m 12m dependiendo de cu ntos minutos quiere que el accesorio se mantenga encendido despu s de detectar movimiento NOTA Disminuir la SENSITIVITY disminuir y la distancia que la unidad puede detectar NOTA Durante el d a la luz indicadora roja destellar cuando se detecte movimiento Esto es normal ENE
4. CFL bulbs contain electronics which may interfere with the motion sensing function of your fixture and are not recommended To meet ENERGY STAR requirements maximum total lamp wattage can not exceed 250 watts HOW IT WORKS Up to PIR does a good job of detecting lateral motion across the 180 Ae range of detection Precision Plus Doppler Radar does an IMEI 39 excellent job detecting motion towards and away from the unit E SS Both systems combined provide enhanced accuracy and complete ol o coverage within the detection range Motion from any direction will 1 o a trigger your floodlight even during hot or cold temperature extremes 180 degrees IMPORTANT SAFETY INSTRUCTIONS When using product basic precautions should always be followed including the following e Read and follow these instructions Heed all warnings including below warnings AND those included on product Save these instructions and warnings For outdoor use only cETLus LISTED for wet location Disassembling your fixture will void the warranty Your fixture is prewired and preassembled for easy installation AWARNING e Bulb gets HOT quickly e The bulb and fixture get extremely hot during use Disconnect power and allow fixture to cool before changing bulb or handling fixture e Fixture should be installed by persons with experience in household wiring or by a qualified electrician The electrical system and the method of electrically connecting
5. no incluir objetos tales como ventanas paredes blancas y agua en la zona de detecci n e Coloque el sensor lejos de objetos m viles como por Fig 1 ejemplo rboles arbustos grandes y tr fico callejero A e No instale mas de un detector de movimiento en un interruptor de pared o circuito MONTAJE Y CABLEADO DEL ACCESORIO NOTA La cubierta universal se adapta a las cajas el ctricas empotradas o instaladas sobre la superficie Fig 2 La caja el ctrica debe tener una profundidad m nima de 3 81 cm 1 1 2 para asegurar una instalaci n adecuada en aplicaciones empotradas NOTA Para obtener los mejores resultados cuando instale m s de un accesorio Radar Doppler Precision Plus Fig 2 3 81 cm 3 81 cm a ZN Qs Octagonal Redonda e Dos o m s unidades montadas de lado a lado dirigidas a la misma direcci n deben estar separadas a 17 5 2 m de distancia e Dos unidades una frente a la otra deben montarse a 100 30 5 m de distancia e El accesorio puede ser montado en la pared o el alero Fig 3 A ADVERTENCIA Riesgo de choque el ctrico Antes de la instalaci n o reparaci n desconecte la alimentaci n el ctrica en el fusible o interrupto autom tico 1 Desconecte la fuente de alimentaci n en la caja principal de fusibles interruptor de circuito 2 Alinee los agujeros del soporte de montaje H con los agujeros de su caja de conexiones Utilizan
6. perilla de MODO Auto autom tico est puesta entre 1m 12m La luz se encienden durante la noche sin motivo aparente ENERGY STAR est patrocinado por la de EE UU y el U S Department of Energy Departamento de Energ a de EE UU Visite www energystar ca gov para m s informaci n Hay movimiento en la zona de detecci n e Aseg rese de que el sensor no est reaccionando a objetos m viles tales como rboles tr fico etc e Si este es el caso disminuya la sensibilidad e Cambie la posici n del sensor de movimiento La unidad est en modo de anulaci n si no hay movimiento e Ponga el interruptor de la luz en OFF durante 90 segundos y vuel va a colocarlo en ON Esto colocar de nuevo la unidad en la modalidad Auto autom tico Si las luces permanecen encendidas con la lente del sensor cubierta p ngase en contacto con el servicio de asistencia al cliente La luz se encienden durante la noche y no se apagan AS ENERGY STAR Para cumplir con los requerimientos de ENERGY STAR la perilla de control del fotosensor debe estar en el modo Auto autom tico para evitar que est en funcionamiento cuando haya suficiente luz de d a La potencia total m xima de la bombilla no debe exceder los 250 W SELECCIONE LA FUNCI N DESEADA Modo de Adjuste de la perilla Como adjustar funcionamiento de MODO interruptor electrico Ajuste de Prueba Las luces deben encenderse por el movimi
7. this equipment not expressly approved by the manufacturer could void the user s authorization to operate this equipment oO COOPER Lighting FOR BEST RESULTS e Install the motion sensor transmitter 8 12 feet above the ground Motion sensor is less sensitive above 12 feet e Locate motion sensor so motion moves laterally or towards the detection zone Fig 1 e Locate sensor away from heat producing sources to prevent false triggering Also be very careful not to include objects such as windows white walls and water in the detection zone e Locate sensor away from moving objects such as trees large shrubs and street traffic e Do not install more than one motion activated floodlight on one wall switch MOUNTING AND WIRING YOUR FIXTURE NOTE Universal coverplate mounts to recessed or surface mounted standard junction boxes Fig 2 Junction box must be at least 1 1 2 in depth for proper installation for recessed mount application NOTE For best performance when installing more than one Precision Plus Doppler Radar fixture e Two or more units mounted side by side facing the same direction should be at least 17 feet apart e Two units facing each other should be mounted at least 100 feet apart e Fixture can be wall or eave mounted Fig 3 A WARNING Risk of electric shock Disconnect power at fuse or circuit breaker before installing or servicing 1 Turn off the power at the main fuse breaker box 2
8. DUCTOS DE COOPER LIGHTING O DEL SUMINISTRO DE CUALQUIER PIEZA DE REPUESTO QUE EXCEDA EL PRECIO DE COMPRA DE LOS PRODUCTOS DE COOPER LIGHTING ORIGINANDO UN RECLAMO NO SE ACEPTAR N CARGOS POR MANO DE OBRA PARA QUITAR O INSTALAR LOS ACCESORIOS Para obtener el servicio de la garant a comun quese con Cooper Lighting LLC al 1 800 334 6871 presione la opci n 2 para el Servicio al Cliente o por correo electr nico a ConsumerProducts cooperlighting com e incluya la siguiente informaci n e Nombre direcci n y n mero de tel fono e Fecha y lugar de compra e Cat logo y cantidad de la compra e Descripci n detallada del problema Todos los productos devueltos deben estar acompa ados por un N mero de autorizaci n de productos devueltos emitido por la compa a y deben devolverse con flete prepagado Se rechazar todo producto recibido sin un N mero de autorizaci n de productos devueltos desde la compa a Cooper Lighting LLC no se hace responsable por la mercanc a da ada durante el transporte Los productos reparados o reemplazados estar n sujetos a los t rminos de esta garant a y se inspeccionan al ser empacados El da o evidente y oculto que se provoque durante el transporte se debe informar de inmediato al transportista que realiza la entrega y se debe presentar un reclamo La reproducci n de este documento sin la aprobaci n previa por escrito de Cooper Lighting LLC est estrictamente prohibida Para solicitar ayuda ll
9. RGY STARS ES DIAGNOSTICO Y SOLUCION DE PROBLEMAS Problema Causa Posible Acci n Correctiva La luz no se No llega electricidad al bombilla encienden e Revise si el interruptor de circuito ha saltado durante la noche e Confirme que el interruptor de pared est encendido aunque haya La bombilla est defectuoso movimiento e Cambie la bombilla La luz ambiental exterior es demasiado brillante S es as para la unidad es de d a e Redirija el cabezal e Cambie la ubicaci n de la unidad o dirijala en direcci n contraria a la luz DESCONECTE LA ENERG A ANTES DE CONTINUAR El cableado hacia la unidad est flojo e Revise los cables y vu lvalos a conectar si fuera necesario usando las tuercas E que se incluyen Hay movimiento en la zona de detecci n e Aseg rese de que el sensor no est reaccionando a objetos m viles tales como rboles tr fico etc COMPRU BELO USTED MISMO e Cubra la lente del sensor con un trozo de cart n para evitar que detecte movimiento Si las luces permanecen apa gadas hay algo en el rea de detecci n que est activando el sensor e Si este es el caso disminuya la sensibilidad e Cambie la posici n del sensor de movimiento Si las luces permanecen encendidas con la lente del sensor cubierta p ngase en contacto con el servicio de asistencia al cliente La unidad est en el ajuste de activaci n por movimiento e Aseg rese de que la
10. ame al 1 800 334 6871 o env e un correo electr nico a ConsumerProducts cooperlighting com Impreso en China we COOPER Lighting Customer First Center 1121 Highway 74 South Peachtree City GA 30269 www cooperlighting com 2011 Lighting LL 2011 Cooper Lighting LLC 08 11 825 0628
11. as firmemente contra el portal mparas y enrosque las l mparas en cada portal mparas Fig 7 No apriete demasiado las bombillas 8 Encienda la electricidad desde la caja de fusibles interruptores autom ticos ORIENTACI N DE LA LUZ Afloje la perilla situada en el costado del portal mpara Incline el portal mpara hacia arriba o abajo hasta la posici n deseada y luego vuelva a ajustar la perilla A ADVERTENCIA Todo apartamiento de las instrucciones de montaje puede generar el riesgo de un choque el ctrico OPERACION DEL ACCESORIO 1 Gire la flecha de la perilla de MODE a la TEST para modo de prueba Fig 8 2 Gire la flecha de la perilla de SENSITIVITY al punto medio entre y 3 Active la energ a del portal mparas Deje que el portal mpara se caliente aproximadamente 90 segundos antes de hacer las pruebas La luz puede o no encenderse durante el periodo de tiempo de calentamiento esto es normal 4 Dirija el detector hacia la direcci n donde se espera que haya movimiento Mantenga por lo menos 1 2 54 cm de espacio entre la cabeza del detector y las l mparas Posicione siempre la cabeza del detector con los interruptores de control apuntando hacia el suelo NOTA Colocaci n de la cabeza del detector Para una ptima detecci n tendr que experimentar con el direccionamiento y los ajustes Cada ubicaci n ser diferente y el terreno puede afectar el ngulo del Montaje
12. b How to Set Operation Adjustment Power Switch MODE knob arrow points to TEST Test Setting Lights should turn ON with motion both day and night Lights should turn OFF after 4 seconds Motion Activated Setting Auto Lights should turn ON with motion only at night and should turn OFF after 1 12 min of no motion points to a time selection within the 1m 12m time range Dusk to Dawn Setting MODE knob arrow activated only at night within the 1m 12m time range Lights should stay ON from dusk to dawn and then reset to motion activated setting after 6 hours Return to Motion Activated Setting from any of the above settings within the 1m 12m time range Auto MODE knob arrow points to a time selection Auto MODE knob arrow points to a time selection Wall Switch Setting connected to fixture Keep wall switch in ON position Keep wall switch in ON position Keep the power to the fixture ON Turn the power OFF ON OFF ON within 3 seconds light will go into override mode Turn the power OFF for at least 90 seconds and then back ON TROUBLESHOOTING Problem Light does not come on with motion at night Cause Solution No power to the fixture e Check if circuit breaker tripped e Confirm wall switch is ON Bulb is faulty e Replace bulb Surrounding external ambient light is too bright If so the unit may think it is daytime e Re aim the head e Rel
13. de nuevo La luz se encienden y se apagan continuamente durante la noche La luz se encienden durante el dia La luz indicadora roja se ENCIENDE y se APAGA durante el d a La unidad est en modo Auto autom tico e Aseg rese de que la unidad est puesta entre 1m 12m modo Auto La luz proveniente de la propia l mpara de la unidad est afectando al sensor de movimiento e Cambie la direcci n de la l mpara e Cambie la posici n del sensor de movimiento Aseg rese de que la perilla no est entre la posici n TEST PRUEBA y 1 min e Coloque la perilla m s cerca de la funci n seleccionada TEST PRUEBA o 1 min Los controles en la base del detector de movimiento se encuentran en el modo de prueba e Mueva la perilla de MODO de la TEST a una selecci n de tiempo 1m 12m Hay sombra sobre el detector de movimiento e Cambie la posici n del sensor de movimiento Durante el d a la luz indicadora roja destellar cuando se detecte movimiento Esto es normal GARANTIA LIMITADA DE 3 A OS LA SIGUIENTE GARANT A ES EXCLUSIVA Y REEMPLAZA A TODAS LAS DEM S GARANT AS YA SEAN IMPL CITAS EXPL CITAS O ESTATUTARIAS INCLUIDAS ENTRE OTRAS LAS GARANT AS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN PARTICULAR Cooper Lighting LLC Cooper Lighting garantiza a sus clientes que los productos de Cooper Lighting no presentar n defectos en los materiales y en la fabricaci n du
14. do ya sea 2 tornillos 6 o 2 tornillos 8 D dependiendo del tama o de los agujeros de su caja de conexiones fije el soporte de montaje H a su caja de conexiones Fig 4 3 Pase los cables del accesorio a trav s de la junta de la placa de cubierta B y posicione la junta B en la placa de cubierta 4 Conecte el alambre negro de la l mpara con el alambre negro de la casa y el blanco con el blanco de la casa usando los conectores de cable E proveidos Conecte el alambre neutral de la casa con el neutral de la l mpara usando el conector de cable F proveido Si la casa no tiene alambre neutral disponible conecte el alambre neutral de la l mpara a la caja de conexi n si es de metal Una fuente neutral alternativa se debe utilizar en caso que la caja de conexi n no es de metal y la casa no tiene alambre neutral Fig 5 5 Fije el accesorio A al soporte de montaje H utilizando el tornillo para la placa de montaje G suministrado Aseg rese de que no se salga ning n cable por debajo de la placa cubrecables Inserte el tap n pl stico de color coincidente F en el agujero del tornillo para la placa de montaje para definir el aspecto final Fig 6 6 Aplique calafateo de silicona alrededor de los bordes de la placa de cubierta y en todo agujero abierto a fin de proveer un cierre que sea estanco para la lluvia y la humedad 7 Inserte juntas obturadoras del recept culo C en el conjunto del portal mpar
15. ede causar interferencia da ina en las comunicaciones de radio Sin embargo no se garantiza que no vaya a producirse interferencia en una instalaci n en particular Si este equipo efectivamente causa una interferencia da ina en la recepci n de radio o televisi n lo que puede determinarse apag ndolo y encendi ndolo se recomienda al usuario que trate de corregir la interferencia por medio de una o m s de las siguientes medidas Reoriente o cambie de lugar la antena receptora Aumente la separaci n entre el equipo y el receptor Conecte el equipo en un tomacorriente que est en un circuito difer ente de aqu l al que se conecta el receptor Consulte a su proveedor o a un t cnico de radio TV experimenta do para que le ayuden ADVERTENCIA Las Reglamentaciones de la FCC establecen que todo cambio o modificaci n no autorizados en este equipo que no est n aprobados expresamente por el fabricante podr an anular la autorizaci n del usuario para operar el equipo PARA OBTENER LOS MEJORES RESULTADOS e Instale el sensor de movimiento transmisor a 2 45 3 65 m 8 12 pies de altura sobre el suelo por encima de 3 65 m 12 pies el sensor de movimiento es menos sensible e Coloque el detector de movimiento de modo que se mueva lateralmente o hacia la zona de detecci n Fig 1 e Coloque el sensor lejos de fuentes que produzcan calor a fin de evitar falsos disparos Adem s medida de lo posible tenga mucho cuidado de
16. eived including interference that may cause undesired operation Under Part 15 of the FCC Rules any changes or modifications to the motion detector described in this instruction sheet that are not expressly approved by Cooper Lighting LLC could void the user s authority to Operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARNING FCC Regulations state that any unauthorized changes or modifications to
17. ento tanto en el d a como en la noche Las luces deben apagarse despu s de 4 segundos Ajuste de activaci n por movimiento Auto autom tico Las luces deber n encenderse con el movimiento nicamente durante la noche y apagarse despu s de 1 12 minutos que cese el movimiento Ajuste Amanecer Atardecer activado s lo durante la noche Las luces deben permanecer encendidas desde el atardecer hasta el amanecer y luego cambiar al ajuste de activaci n por movimiento despu s de 6 horas Mueva la perilla al ajuste de activaci n por movimiento desde cualquiera de los ajustes anteriores La perilla de MODO apunta hacia la TEST La perilla de MODO Auto autom tico apunta hacia una selecci n de tiempo entre el rango de tiempo de 1m 12m La perilla de MODO apunta hacia una selecci n de tiempo entre el rango de tiempo de 1m 12m La perilla de MODO Auto autom tico apunta hacia una selecci n de tiempo entre el rango de tiempo de 1m 12m Ajuste de interruptor de pared conectado al accesorio Mantenga el interruptor de pared en la posici n de ENCENDIDO ON Mantenga el interruptor de pared en la posici n de ENCENDIDO ON Mantenga encendida la corriente al accesorio APAGUE OFF ENCIENDA ON APAGUE OFF y ENCIENDA ON la corriente en menos de 3 segundos la luz entrar modo de la invalidaci n APAGUE OFF la corriente por al menos 90 segundos y luego ENCIENDALA ON
18. erca de agua Limpie nicamente con un trapo seco No obstruya las aberturas de ventilaci n Instale de conformidad con las instrucciones del fabricante No instale cerca de fuentes de calor tales como radiadores rejillas de aire caliente estufas u otros aparatos incluyendo amplificadores que produzcan calor Use nicamente acoplamientos accesorios especificados por el fabricante Este dispositivo cumple con la Parte 15 de las Reglas de la Comisi n Federal de Comunicaciones FCC de los E U de A La operaci n est sujeta a las dos condiciones siguientes 1 Este dispositivo no puede causar interferencia da ina y 2 este dispositivo debe aceptar toda interferencia recibida incluyendo la interferencia que pueda causar un funcionamiento indeseado Seg n la Parte 15 de las Reglas de la FCC todo cambio o modificaci n al detector de movimiento descripto en esta hoja de instrucciones que no est expresamente aprobado por Cooper Lighting LLC podr a anular la autorizaci n del usuario para operar el equipo NOTA Este equipo ha sido probado y se ha verificado que cumple con los l mites de un dispositivo digital Clase B de acuerdo con la Parte 15 de las Reglas de la FCC Estos limitesestan dise ados a fin de proveer una protecci n razonable contra la interferencia da ina en una instalaci n residencial Este equipo genera usa y puede irradiar energ a de radio frecuencia y si no se instala y utiliza de acuerdo con las instrucciones pu
19. eriencia en cableado dom stico o por un electricista calificado El sistema el ctricoy el m todo de conexi n el ctrica del portal mparas debe cumplir con el C digo el ctrico nacional y los c digos locales sobre edificios e Reemplace siempre la bombilla con una del mismo vatiaje o m s bajo que el marcado Si instala l mparas de mayor potencia puede crear riesgo de incendio Si usa l mparas de mayor potencia se anula la garant a Utilice una bombilla de hal geno PAR de un total m ximo de 150 W 180 grados PRECAUCION Conecte el portal mparas a una fuente de energ a de 120 Voltios 60 Hz Cualquier otro tipo de conexi n anula la garant a Debe montar el artefacto sobre una caja de conexiones empotradas con toma de tierra marcada para usar en lugares h medos Adecuado para instalarse en la pared o en aleros solamente No es adecuado para instalarse mont ndolo en el suelo No permita que el sensor toque el alojamiento de la l mpara mantenga por lo menos 1 pulgadas 2 54 cm de espacio entre el portal mparas y el sensor Mant ngalo alejado de objetos inflamables No coloque el artefacto en posici n dentro de dos pulgadas 5 cm de cualquier material combustible Para un funcionamiento y protecci n adecuados contra posibles da os los botones de ajuste de la cabeza del sensor de movimiento se deben ajustar en direcci n al piso UTILICE CONDUCTORES DE SUMINISTRO QUE SOPORTEN UN M NIMO DE 90 C No use este aparato c
20. escription of problem All returned products must be accompanied by a Return Goods Authorization Number issued by the Company and must be returned freight prepaid Any product received without a Return Goods Authorization Number from the Company will be refused Cooper Lighting LLC is not responsible for merchandise damaged in transit Repaired or replaced products shall be subject to the terms of this warranty and are inspected when packed Evident or concealed damage that is made in transit should be reported at once to the carrier making the delivery and a claim filed with them Reproductions of this document without prior written approval of Cooper Lighting LLC are strictly prohibited For assistance call 1 800 334 6871 or e mail us at ConsumerProducts cooperlighting com Printed in China ARTICULOS NECESARIOS se compran por separado e Destornillador en cruz Phillips e Calafateo de silicona resistente a la intemperie e 2 lamparas para proyector tipo PAR 38 de 100 W maximo NOTA Este accesorio fue dise ado para trabajar con bombillas reflectoras de Hal geno PAR de 150 vatios como m ximo Para mayor eficiencia de energ a use bombillas reflectoras Hal geno PAR de menor vataje No se recomienda el uso de bombillas fluorescentes compactas CFL porque tienen partes electr nicas que pueden interferir con las funciones de detecci n de movimiento de su accesorio Para cumplir con los requerimientos de ENERGY STAR la potencia t
21. from the unit s own lamp is affecting the motion sensor e Re aim the lamp e Reposition motion sensor Make sure knob is not positioned between TEST and 1m e Reposition knob closer to selected function either TEST or 1m blinks on and off at night The controls on the bottom of the motion sensor are in the test mode e Reposition MODE knob off of TEST to a time selection 1m 12m The motion detector is shadowed e Reposition motion sensor Light is on during the day Red LED Indicator During daylight hours the red LED indicator will flash when motion Light Comes ON is detected This is normal And OFF During Daylight Hours 3 YEAR LIMITED WARRANTY THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE Cooper Lighting LLC Cooper Lighting warrants to customers that for a period of three years from the date of purchase Cooper Lighting s products will be free from defects in materials and workmanship The obligation of Cooper Lighting under this warranty is expressly limited to the provision of replacement products This warranty is extended only to the original purchaser of the product A purchaser s receipt or other proof of date of original purchase acceptable to Cooper Lighting This is required before warranty performance shall be rendered This warra
22. nty does not apply to Cooper Lighting products that have been altered or repaired or that have been subjected to neglect abuse misuse or accident including shipping damages This warranty does not apply to products not manufactured by Cooper Lighting which have been supplied installed and or used in conjunction with Cooper Lighting products Damage to the product caused by replacement bulbs or corrosion or discoloration of brass components are not covered by this warranty LIMITATION OF LIABILITY IN NO EVENT SHALL COOPER LIGHTING BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT STRICT LIABILITY OR IN TORT INCLUDING NEGLIGENCE NOR FOR LOST PROFITS NOR SHALL THE LIABILITY OF COOPER LIGHTING FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE TERMS OR THE MANUFACTURE SALE DELIVERY USE MAINTENANCE REPAIR OR MODIFICATION OF COOPER LIGHTING PRODUCTS OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE EXCEED THE PURCHASE PRICE OF COOPER LIGHTING PRODUCTS GIVING RISE TO A CLAIM NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES To obtain warranty service please contact Cooper Lighting LLC at 1 800 334 6871 press option 2 for Customer Service or via e mail ConsumerProducts cooperlighting com and include the following information e Name address and telephone number e Date and place of purchase e Catalog and quantity purchase e Detailed d
23. ocate or reposition the unit away from the light TURN OFF POWER BEFORE CONTINUING Wiring to the unit is loose e Check wiring and reconnect if necessary using wire nuts E provided There is motion in the detection zone e Make sure the sensor is not picking up moving objects such as trees traffic etc TEST FOR YOURSELF e Cover the sensor lens with cardboard to prevent sensor from detecting motion If the light stays off something in the detection zone is triggering the sensor e f this is the case reduce the sensitivity e Reposition the sensor If the light stays on with the sensor lens covered contact customer service Unit is in the motion activated setting e Make sure Auto MODE knob is set between 1m 12m Light comes on for no apparent reason at night Light stays on at night and does not turn off There is motion in the detection zone e Make sure the sensor is not picking up moving objects such as trees traffic etc e Reduce the sensitivity e Reposition the sensor Unit is in override mode if there is no motion e Turn the light switch to the OFF position for 90 seconds and then turn back to the ON postion This will send the unit back into the motion activated setting Auto If the light stays on with the sensor lens covered contact customer service Unit is in the Auto mode e Make sure the unit is set between 1m 12m Auto mode Light continuously The light given
24. otal m xima de la bombilla no debe exceder 250 W COMO FUNCIONA Hasta PIR funciona muy bien en la detecci n de movimiento lateral 70 pies en un rango de detecci n de 180 El Radar Doppler Precision 7 Plus hace un excelente trabajo detectando movimiento de A Sei acercamiento y alejamiento de la unidad La combinacion de at NOS k ambos sistemas proporciona precisi n avanzada y cobertura e LA completa dentro del rango de detecci n El movimiento desde A cualquier direcci n disparar el reflector incluso en temperaturas extremas de calor y fr o INSTRUCCIONES IMPORTANTES DE SEGURIDAD Al utilizar el producto siempre se deben seguir las precauciones b sicas inclu do lo siguiente e Lea y siga estas instrucciones e Tenga en cuenta todas las advertencias incluyendo las advertencias a continuaci n Y aquellas incluidas en el producto Guarde estas instrucciones y advertencias S lo para uso en exteriores CETLus para ubicaciones mojadas Adecuado para instalarse en la pared o en aleros solamente NO es adecuado para instalarse mont ndolo en el suelo Desensamblar la l mpara anular la garant a e La l mpara es percableada y ensamblado para facilitar la instalaci n A ADVERTENCIA e La bombilla se CALIENTA r pidamente e The bulb and fixture get extremely hot during use Disconnect power and allow fixture to cool before changing bulb or handling fixture e El portalamparas debe ser instalado por personas con exp
25. ower at main fuse breaker box AIMING THE LIGHT Loosen the knob on the side of the lampholder Tilt lampholder up or down to desired position then retighten knob Ah WARNING Deviation from the assembly instructions may result in a risk of electric shock OPERATING YOUR FIXTURE 1 Turn the arrow on the MODE knob to TEST for test mode Fig 8 2 Turn the arrow on the SENSITIVITY knob to a middle point between and 3 Turn on the power to the fixture Allow fixture to warm up approximately 90 seconds before testing Lights may or may not come on during warm up period this is normal Fig 1 Fig 2 1 1 2 in 1 1 2 in e gt ai D Fy SZ YA Round Octagonal Fig 3 I SAD Wall mount Eave mount Fig 4 4 Aim sensor toward the general direction that motion will be coming from Maintain at least 1 of clearance between sensor head and lamps Always position the sensor head with control switches facing toward the ground NOTE Sensor Head Placement For optimum detection you may have to experiment with aiming and settings Each location will be different and your terrain may affect the angle your sensor needs Adjusting the angle will change your area of detection Here are some general guidelines to help with setup e 8 12 above the ground is a good
26. range for the placement of your fixture e For an 8 mounting height placing the sensor at a 5 angle below horizontal should work well for most locations Fig 9 e f the fixture is mounted higher the angle of the sensor below horizontal should increase 5 Walk through the detection zone at the farthest distance you want your detector to detect motion 6 Adjust the SENSITIVITY knob until you get desired results For more range aim sensor slightly upward For less range aim sensor head slightly downward Lights will turn OFF 4 seconds after motion stops 7 Adjust the Auto MODE knob to a time selection from 1m 12m depending on how many minutes you want the fixture to stay on after motion is detected At dusk the photo control will activate your fixture to operate according to the settings chosen NOTE Decreasing the SENSITIVITY will decrease the distance the unit can detect NOTE During daylight hours the red LED indicator light will flash when motion is detected This is normal ENERGY STAR Department of Energy ENERGY STAR ENERGY STAR is sponsored by the U S Environmental Protection Agency amp U S Visit www energystar gov to learn more To meet ENERGY STAR requirements the photosensor control knob must be in the Auto mode to prevent operation during full daylight Maximum total lamp wattage can not exceed 250 watts SELECTING YOUR DESIRED FEATURE Mode of MODE Kno
27. rante un per odo de tres a os desde la fecha de compra La obligaci n de Cooper Lighting seg n esta garant a se limita expresamente al suministro de los productos de reemplazo Esta garant a se extiende s lo para el comprador original del producto Un recibo del comprador u otra prueba de la fecha de compra original aceptable para Cooper Lighting Esto es necesario para la ejecuci n de la garant a Esta garant a no se aplica a los productos de Cooper Lighting que hayan sido alterados o reparados o que estuvieron sujetos a negligencia abuso mal uso o accidente incluso los da os durante el env o Esta garant a no se aplica a los productos Cooper Lighting no fabricados por Cooper Lighting que hayan sido suministrados instalados o utilizados junto con los productos Cooper Lighting Los da os del producto causados por bombillas de reemplazo corrosi n o decoloraci n de los componentes de lat n no est n cubiertos por esta garant a LIMITACI N DE RESPONSABILIDAD COOPER LIGHTING NO SER RESPONSABLE LEGAL EN NING N CASO DE DA OS INDIRECTOS ACCIDENTALES O RESULTANTES SIN IMPORTAR LA ACCI N LEGAL YA SEA POR CONTRATO RESPONSABILIDAD ESTRICTA O DE FORMA EXTRACONTRACTUAL INCLUYENDO LA NEGLIGENCIA TAMPOCO DE LA P RDIDA DE GANANCIAS COOPER LIGHTING TAMPOCO SER RESPONSABLE DES O DA OS QUE SURJAN O EST N CONECTADOS CON ESTOS T RMINOS O CON LA FABRICACI N VENTA ENTREGA USO MANTENIMIENTOM REPARACI N O MODIFICACI N DE LOS PRO
28. the fixture to it must be in accordance with the National Electrical Code and local building codes e Always replace bulb with the same wattage or lower wattage than marked Installing a bulb of a higher wattage could create a fire hazard Use of a higher wattage bulb will void the warranty Maximum 150 watt PAR halogen bulb Suitable for wall mount or eave mount only NOT suitable for ground mount installation Suitable for wall mount or eave mount only NOT suitable for ground mount installation Do not allow sensor head to touch light housing maintain at least 1 inch space between fixture and sensor Keep away from flammable objects Do not position fixture within 2 inches of any combustible materials For proper operation and protection against damage the motion sensor head adjustment knobs must be facing the ground MINIMUM 90 C SUPPLY CONDUCTORS Do not use this apparatus near water Clean only with a dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Only use attachments accessories specified by the manufacturer This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference rec
Download Pdf Manuals
Related Search
Related Contents
Hotpoint UQ89I Double Oven User Manual SP EC IA LIZ ED 20 12 医療認証基盤整備事業 - NTTデータ経営研究所 Biostar P4M80-M4 Owner's Manual 国勢調査を実施します! TP-Link 24+2/24+2G User's Manual Origin Storage Internal Notebook Keyboard - German GUITARRA ELÉCTRICA SETUP & RESOURCE GUIDE 820 A - NETTOYANT ECRANS PLATS LCD Copyright © All rights reserved.