Hampton Bay 26829 Installation Guide

image

Contents

1. Quantity Description Quantity Mounting bracket 1 A e Baldownred assembly 1 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 IMPORTANT This product and or components are governed by one or more of the following U S Patents and other patents pending 5 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Installation MOUNTING OPTIONS WARNING To reduce the risk of fire electric shock or personal injury mount to outlet box marked Acceptable for fan support of 3516 15 9 Kg or less and use screws provided with the outlet box An outlet box NOTE You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 30 away from horizontal commonly used for the support of lighting fixtures may not be acceptable for fan support and may need to be replaced If in doubt consult a qualified electrician Hanger bar If your ceiling fan does not have an existing UL listed mounting box then install one using the following instructions Disconnect the power by removing the fuses or turning off the circuit breakers Secure the outlet box directly to the building structure euler pox Use the appropriate fasteners and
2. eese nere 2 Informaci n de Seguridad 2 etere aT Pee ri I 3 Pre Instalaci n cscisioncaccnncananinnarannnn nocacnrnocone cn nario can crraniciiada 3 Instalaci ns 6 Ensamblaje wisesseccnaseceiciceactnasscntstenaacensasvedacsuddewascanadsenaade lt usazaas 7 Funcionamiento anui ausa nia daa usa A nas rancia 12 Mantenimiento y 13 Soluci n de Problemas eene 13 Informaci n de Seguridad 1 Todo el cableado debe cumplir con el C digo Nacional de Electricidad ANSI NFPA 70 1999 y con los c digos locales de electricidad La instalaci n el ctrica debe ser hecha por un electricista certificado y calificado 2 Lacaja el ctrica y estructura de soporte deben montarse de forma segura y tener capacidad para sostener de manera confiable 35 Ib Usa solamente cajas el ctricas aprobadas por UL marcadas como Aprobada como soporte de ventiladores de 35 Ib 15 9 kg o menos 3 Elventilador debe ir montado con un m nimo de 10 pies 3 m de separaci n entre el borde trasero de las aspas y el piso 4 No muevas el interruptor de reversa mientras las aspas del ventilador est n en movimiento Debes apagar el ventilador y detener las aspas antes de invertir la direcci n de las aspas No coloques objetos en la trayectoria de las aspas 6 Los diagramas el ctricos son
3. Repite para las aspas restantes Ajusta todos los tornillos 10 Funcionamiento Instala el control de pared de 4 velocidades Ver las instrucciones incluidas en el paquete del control de pared C mo operar el ventilador NOTA Espera a que se detenga completamente el ventilador antes de colocar el interruptor deslizante para invertir la direcci n de giro de las aspas El interruptor de reversa est ubicado en la superficie del acoplador J Para invertir la direcci n de giro de las aspas sigue las instrucciones a continuaci n Afloja el tornillo de ajuste MM para asegurar la tapa del acoplador D Desliza la tapa del acoplador D hacia arriba para acceder al acoplador J y al interruptor de reversa YY Coloca el interruptor de reversa YY en la direcci n deseada para clima c lido coloca el interruptor en la posici n baja Para clima fr o col calo en la posici n alta AO 2 ON Clima c lido Hacia adelante Un flujo de aire hacia abajo crea Clima fr o Reversa Un flujo de aire hacia arriba mueve el aire un efecto refrescante Esto te permite fijar tu aire acondicionado c lido lejos del techo Esto te permite fijar tu unidad de calefacci n a una temperatura m s alta sin afectar tu comodidad a una temperatura m s baja sin afectar tu comodidad 11 HOMEDEPOT COM Par
4. We agree to correct such defects without charge or at our option replace with a comparable or superior model if the product is returned To obtain warranty service you must present a copy of the receipt as proof of purchase All costs of removing and reinstalling the product are your responsibility Damage to any part such as by accident or misuse or improper installation or by affixing any accessories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not allow a limitation on how long an implied war ranty lasts so the above limitation may not apply to you The retailer shall not be liable for incidental consequential or special damages arising out of or in connection with product use or performance exc
5. acoplador D hasta que descanse en la parte superior de la carcasa del motor G Aprieta el tornillo de ajuste ZZ para asegurar la tapa del acoplador D en el tubo bajante B Desliza la cubierta C hacia el tubo bajante B C mo instalar la bola en el tubo bajante Desliza la bola de soporte H en la parte superior del tubo bajante B pasando los orificios en el tubo bajante B Vuelve a colocar el pasador de soporte RR en los orificios del extremo superior del tubo bajante B Desliza la bola H hacia arriba y alinea los orificios de la misma y del tubo bajante B Aseg rate de que el pasador de soporte RR se alinee en la ranura de la bola H Atornilla el tornillo de ajuste PP y la arandela de seguridad QQ en el orificio de la bola H y el tubo bajante B para asegurar la bola Vuelve a conectar el cable verde a tierra I al tubo bajante usando el tornillo SS y la arandela que se quitaron en el paso 1 Ensamblaje Colgar el Ventilador 5 C mo instalar el soporte de montaje ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica o lesiones personales monta el ventilador sobre una caja el ctrica marcada como aprobada como soporte de ventiladores de 35 Ib 15 9 kg o menos y usa los tornillos de montaje que vienen con la misma Pasa los cables de suministro de 120 Voltios a trav s del orificio centra
6. s lo para referencia Despu s de concluir con las conexiones el ctricas debes voltear los conductores empalmados hacia arriba y meterlos con cuidado en la caja el ctrica Los cables deben estar separados con el cable a tierra y el conductor a tierra del equipo en uno de los lados de la caja el ctrica 8 Todos los tornillos colocados se deben verificar y ajustar donde sea necesario antes de la instalaci n ADVERTENCIA Para reducir el riesgo de lesiones no dobles los soportes de las aspas tambi n llamados bridas durante o despu s de la instalaci n No coloques ning n objeto en la trayectoria de las aspas ADVERTENCIA Para reducir el riesgo de incendio o descarga el ctrica no utilices este ventilador con ning n dispositivo de control de velocidad de estado s lido ADVERTENCIA Para evitar una posible descarga el ctrica apaga la electricidad en la caja principal de fusibles antes de instalar el cableado Si crees que no tienes suficiente experiencia o conocimientos sobre cableado el ctrico contrata a un electricista con licencia ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica o lesiones personales monta el ventilador sobre una caja el ctrica marcada como aprobada como soporte de ventiladores de 35 Ibs 15 9 kg o menos y usa los tornillos de montaje que vienen con la misma ADVERTENCIA Para reducir el riesgo de descarga este ventilador se debe instalar cont
7. Aseg rate de que los tornillos que unen el soporte de aspa al cuerpo del motor est n bien ajustados Aseg rate de que las conexiones de tuerca de cable no choquen unas con otras o con la pared interior de la caja del interruptor Permite un per odo de 24 horas de adaptaci n La mayor a de los ruidos asociados con un nuevo ventilador desaparecen en ese per odo Si usas el kit de luces de Ventilador de Techo aseg rate de que los tornillos que sujetan el vidrio est n bien colocados Verifica que las bombillas est n bien aseguradas Aseg rate de que la cubierta est a corta distancia del techo No debe tocar el techo Aseg rate de que tu caja el ctrica y las almohadillas aislantes de goma sean instaladas entre la placa de montaje y la caja el ctrica El ventilador oscila Verifica que todos los tornillos y brazos de las aspas est n seguros La mayor a de los problemas de oscilaci n del ventilador se deben a que las aspas no est n a un mismo nivel Verifica este nivel seleccionando un punto en el techo sobre la punta de una de las aspas Mide desde un punto en el centro del aspa a un punto en el techo Gira el ventilador hasta que la pr xima aspa quede posicionada para medir y mide desde el mismo punto en cada aspa hasta el techo Repite este proceso para cada aspa Las desviaciones de la medici n no deben ser mayores de de 0 31 cm Enciende el ventilador durante diez mi
8. Item 434 940 434 972 526 012 Model 52869 26829 52860 USE AND CARE GUIDE INDUSTRIAL 60 INCH CEILING FAN Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HAMPTONBAY COM THANK YOU We appreciate the trust and confidence you have placed in Hampton Bay through the purchase of this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay Table of Contents Table of Contents eee 2 Safety Information e eecce ceca corso nnndnnnasiancecienen 2 Warranty eee 3 Pre Installation cus ianua axungia o cauia 3 Installation eee eere eene nnns 6 m Q 7 PPP y A 12 Care and 13 Troubleshooting eene otn nna annue 13 Safety Information 1 All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 1999 and local electrical codes Electrical installation should be performed by a qualified licensed electrician 2 The outle
9. TT Installing the ball on the downrod Slide the hanger ball H onto the top of the downrod B past the holes in the downrod B Replace the support pin RR into the holes located at the top of the downrod B Slide the ball H up and align the holes in the ball H and downrod B Make sure the support pin RR aligns in the slot of the ball H Screw the set screw PP and lockwasher QQ into the hole in the ball H and downrod B to secure the ball Reattached the green ground wire I to the downrod using the screw SS and washer that were removed in step 1 Assembly Hanging the Fan continued 6 Hanging the fan WARNING When using the standard ball downrod mounting the tab in the ring at the bottom of the mounting bracket must rest in the groove of the hanger ball Failure to properly seat the tab in the groove could cause damage to the wiring Carefully lift the fan motor assembly G up to the mounting bracket A Seat the hanger ball portion of the ball downrod assembly B in the mounting bracket socket Ensure that the tab on the mounting bracket A socket is properly seated in the groove in the hanger ball B 8 Attaching the canopy Align the locking slots of the ceiling canopy C with the two screws in the mounting bracket A Push up to engage the slo
10. a licensed electrician WARNING To reduce the risk of fire electric shock or personal injury mount to outlet box marked acceptable for fan support of 35 16 15 9 kg or less and use screws provided with the outlet box WARNING To reduce the risk of shock this fan must be installed with a wall control switch WARNING To reduce the risk of fire electric shock or personal injury wire only a single wall control panel switch and ceiling fan unit together Wiring two or more ceiling fans to any wall control panel switch may cause the circuitry to fail by overheating Please do not attempt to defeat this feature of the ceiling fan system as doing so will void the warranty both explicit and implicit stipulations thereof CAUTION To reduce the risk of personal injury use only the screws provided with the outlet box PN CAUTION To avoid personal injury or damage to the fan and other items use caution when working around or cleaning the fan Warranty The supplier warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a life time after the date of purchase by the original purchaser The supplier also warrants that all other fan parts excluding any glass or acrylic blades to be free from defects in workmanship and material at the time of shipment from the factory for a period of two years after the date of purchase by the original purchaser
11. a obtener asistencia llama al 1 877 527 0313 Mantenimiento y Limpieza ADVERTENCIA Aseg rate de que la corriente est apagada antes de limpiar el ventilador Debido al movimiento natural del ventilador algunas conexiones pueden aflojarse Revisa las conexiones de soporte soportes y accesorios de aspas dos veces al a o Verifica que est n seguros No es necesario desmontar el ventilador del techo Limpia tu ventilador con frecuencia para que luzca como nuevo a pesar de los a os No uses agua al limpiar esto puede da ar el motor o la madera o causar descargas el ctricas Usa solamente un cepillo suave o un pa o sin pelusas para evitar ara ar el acabado El revestimiento est sellado con laca para minimizar la decoloraci n u opacidad Puedes aplicar una fina capa de pulimento para muebles a la madera para una mayor protecci n y belleza Cubre los ara azos pequefios con una leve aplicaci n de lustrador para calzado Tu ventilador no necesita lubricaci n El motor tiene cojinetes de bola sellados permanentemente lubricados Soluci n de problemas Problema Soluci n ss El ventilador Revisa los fusibles o disyuntores principales y secundarios no enciende Verifica las conexiones de cables en l nea al ventilador y las conexiones de cables del interruptor en la caja de interruptores El ventilador Aseg rate de que los tornillos de la carcasa del motor est n ajustados hace ruido
12. e al los cable s terminal es a tierra verde s UU del ventilador Conecta el cable blanco del motor del ventilador VV al cable blanco de suministro de energ a VV usando una tuerca de cable DD Conecta el cable negro del motor del ventilador WW al cable negro de suministro de energ a WW usando una tuerca de cable DD Despu s de conectar los cables sep ralos de manera que los cables verde UU y blanco VV queden de un lado de la caja el ctrica XX y el cable negro WW del otro Gira las tuercas de conexi n del cable hacia arriba y con cuidado coloca el cableado dentro de la caja el ctrica XX Ensamblaje continuaci n 1 0 C mo montar las aspas del ventilador ensambladas de f brica Las aspas presentan tecnolog a nueva m s eficiente Las aspas no son reversibles A NOTA Las aspas y los brazos de las aspas vienen previamente Coloca el ensamblaje de las aspas E en el motor de tal manera que orificios de los tornillos de montaje queden alineados con los orificios roscados Inserta el tornillo JJ la arandela de resorte KK y la arandela plana LL en el orificio pero no los ajustes completamente Aseg rate de que el segundo orificio en el ensamblaje de las aspas est alineado con un orificio en la carcasa del motor G De la misma manera coloca un segundo tornillo JJ arandela de resorte KK y arandela plana LL en el ensamblaje de las aspas
13. ept as may otherwise be accorded by law Some states do not allow the exclusion of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties Shipping costs for any return of product as part of a claim on the warranty must be paid by the customer Contact the Customer Service Team at 1 877 527 0313 or visit www HamptonBay com Pre Installation SPECIFICATIONS Airflow Efficiency Higher Is Better Cube Feet CFM WATT 17 64 Ibs 19 4 Ibs 258 NOTE Measured according to Energy STAR approved Solid State test method TOOLS REQUIRED CD Phillips Flat blade screwdriver A screwdriver Adjustable Electrical wrench O tape cutter Step ladder 3 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Pre Installation continued HARDWARE INCLUDED A NOTE Hardware not shown to actual size Pat Description Quantity Om Jwoodserew Canopy mounting screw 4 lt Canopy mounting lock waster 4 00 Prasti wire connector 68 1 m ee 1 m Pat Description Quantity 8 ritos 8 we ew s Low Split pin Pre Installation continued PACKAGE CONTENTS
14. je del tubo bajante bola Afloja la bola de soporte H quitando el tornillo de ajuste PP y la arandela de seguridad QQ en la parte superior del tubo bajante B que sujeta la bola de soporte hasta el tubo bajante Desliza la bola de soporte H por el tubo bajante B y retira el pasador de soporte RR Desenrosca el cable verde a tierra I ubicado en la parte superior de tubo bajante B quitando el tornillo SS del mismo 2 Como instalar el tubo bajante Inserta los cables que salen por la parte superior de la carcasa del motor G a trav s del tubo bajante B Inserta el tubo bajante B en el acoplador J en la parte superior de la carcasa del motor G Alinea los orificios en la parte inferior del tubo bajante B con los orificios en el acoplador J e inserta el perno para gancho EE Asegura el perno para gancho EE usando la arandela plana FF la arandela de seguridad HH y la tuerca hexagonal GG Inserta el pasador hendido NN en el extremo del perno para gancho EE y separa los extremos del pasador hendido NN para asegurar el perno para gancho EE Aprieta firmemente el tornillo de ajuste 77 HOMEDEPOT COM Para obtener asistencia llama al 1 877 527 0313 Ensamblaje continuaci n 3 C mo instalar la tapa del acoplador y la cubierta Coloca la tapa del acoplador D en el tubo bajante B y empuja la tapa del
15. l en el soporte de montaje A Instala la placa de montaje de techo sobre la caja el ctrica deslizando el soporte de montaje A sobre los dos tornillos TT suministrados con la caja el ctrica Si es necesario usa arandelas niveladoras no incluidas entre el soporte de montaje A y la caja el ctrica F jate que el lado plano del soporte de montaje A est hacia la caja el ctrica Ajusta firmemente los dos tornillos de montaje TT Ensamblaje Colgar el Ventilador continuaci n 6 C mo colgar el ventilador ADVERTENCIA Cuando uses el montaje de tubo bajante y bola est ndar la pesta a en el aro en la parte inferior del soporte de montaje debe encajar en la ranura de la bola de soporte Si la pesta a no se asienta correctamente en la ranura se puede da ar el cableado hasta el soporte de montaje A Coloca la bola de soporte del ensamblaje del tubo bajante bola B en el soporte de montaje Aseg rate de que la pesta a sobre el soporte de montaje A encaje bien dentro de la ranura de la bola de soporte B 8 Como montar la cubierta en las ranuras y gira de izquierda a derecha para asegurar la cubierta C en su sitio Ajusta firmemente los dos tornillos de montaje BB con la arandela de seguridad CC Instala los dos tornillos de montaje BB restantes en los orificios de la cubierta C y aprieta firmeme
16. materials The outlet box and its bracing must be able to fully support the weight of the moving fan at least 35 Ibs Do not use a plastic gant P If the canopy touches the downrod then remove the decorative canopy outlet box The illustrations below show three different ways to mount the bottom cover and turn the canopy 180 before attaching the canopy to outlet box the mounting plate To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown above available at any Home Depot store e Outlet Box Provide Strong Support Ceiling Mounting Plate Recessed Outlet Box Assembly Dismantling the ball downrod assembly Loosen the hanger ball H by removing the set screw PP and lockwasher QQ at the top of the downrod B which holds the hanger ball to the downrod Slide the hanger ball H down the downrod B and remove the support pin RR Unscrew the green groundwire I located at the top of the downrod B by unscrewing the screw SS on the downrod B 2 Installing the downrod Route the wires exiting the top of the motor housing G through the downrod B Insert the downrod B into the coupler J on the top of the motor housing G Align the holes at the bottom of the downrod B with the holes in the coupler J and insert the hanger bolt EE Sec
17. nte Con cuidado alza el ensamblaje del motor del ventilador G Alinea las ranuras de cierre de la cubierta de techo C con los dos tornillos del soporte de montaje A Alza para enganchar T C mo conectar el cable de seguridad Enrosca el tornillo para madera AA en el techo Coloca el extremo en bucle del cable de seguridad K sobre el tornillo para madera AA y luego aprieta firmemente el tornillo o conecta el cable de seguridad directamente a la viga externa o al soporte de montaje A HOMEDEPOT COM Para obtener asistencia llama al 1 877 527 0313 Ensamblaje Colgar el Ventilador continuaci n 0 C mo hacer las conexiones el ctricas ADVERTENCIA Cada cable no suministrado con este ventilador est dise ado para aceptar un m ximo de un solo circuito el ctrico dom stico de calibre 12 y dos cables del ventilador Si tienes un cableado dom stico de calibre superior a 12 o m s de un cable dom stico para conectar el cableado del ventilador consulta a un electricista para el tama o adecuado de tuercas de cable IMPORTANTE Usa las tuercas de conexi n de cables DD que vienen con tu ventilador Sujeta los conectores con cinta de electricista y aseg rate de que no hayan conexiones o cables sueltos Conecta el conductor a tierra del cable de 120 Voltios puede ser un cable desnudo o un cable con aislante verd
18. nutos Usa el kit de compensaci n de aspas incluido si sigues notando oscilaci n 12 Preguntas problemas o piezas faltantes Antes de regresar a la tienda llama al Servicio al Cliente de Hampton Bay de Lunes a Viernes entre 8 a m y 6 p m hora del Este de EE UU 1 877 527 0313 HOMEDEPOT COM Conserva este manual para uso en el futuro X0000000000 A
19. o El minorista no ser responsable por da os directos indirectos o especiales que resulten o deriven del uso o rendimiento del producto excepto en casos en que lo estipule la ley Algunos estados no permiten la exclusi n o limitaci n de da os directos o indirectos por lo que la limitaci n o exclusi n anterior podr a no aplicarse a usted Esta garant a le otorga derechos legales espec ficos pero es posible que tambi n tenga otros derechos que var an de un estado a otro Esta garant a sustituye todas las garant as anteriores Los costos de env o de cualquier devoluci n de productos hecha como parte de una reclamaci n de garant a deben ser pagados por el cliente Comun quese con el Equipo de Servicio al Cliente por el 1 877 527 0313 o visite www homedepot com Pre Instalaci n ESPECIFICACIONES Consume j Eficiencia de Flujo d de Aire Mientras Peso Peso Tama o Velocidad Voltios Amperios Energ a M s Alta Mejor Neto Bruto PIES CUB X MIN VATIOS o 1 52 m 2i fete NOTA Medida de acuerdo al m todo de prueba de Estado S lido aprobado por Energy STAR HERRAMIENTAS NECESARIAS e Destornillador Destornillador Phillips A Cortacables plano Llave Cinta ajustable O de electricista Escalera 3 HOMEDEPOT COM Para obtener asistencia llama al 1 877 527 0313 Pre Instalaci n continuaci n HERRAJES INCLUIDOS m NOTA No se muestra el tama o real de los herrajes Pieza Desc
20. oration or tarnishing You can apply a light coat of furniture polish to the wood for additional protection and enhanced beauty Cover small scratches with a light application of shoe polish You do not need to oil your fan The motor has permanently lubricated sealed ball bearings Troubleshooting Problem SAR ss The fan will not start Check the main and branch circuit fuses or breakers Check the line wire connections to the fan and switch wire connections in the switch housing The fan is noisy Ensure all motor housing screws are snug Ensure the screws that attach the fan blade bracket to the motor hub are tight Ensure the wire nut connections are not rattling against each other or the interior wall of the switch housing Allow a 24 hour breaking in period Most noises associated with a new fan disappear during this time If you are using the Ceiling Fan light kit ensure the screws securing the glassware are tight Check that the light bulbs are also secure Ensure the canopy is a short distance from the ceiling It should not touch the ceiling Ensure your outlet box is secure and rubber isolator pads were used between the mounting plate and outlet box The fan wobbles Check that all blade and blade arm screws are secure Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling ab
21. ove the tip of one of the blades Measure from a point on the center of the blade to the point on the ceiling Rotate the fan until the next blade is positioned for measurement and measure from the same point on each blade to the ceiling Repeat for each blade Any measurement deviation should be within 1 8 in Run the fan for ten minutes Use the enclosed blade balancing kit if the blade wobble is still noticeable 12 Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HAMPTONBAY COM Retain this manual for future use Art culo N m 434 940 434 972 526 012 Modelo N m 52869 26829 52860 GU A DE USO Y MANTENIMIENTO VENTILADOR DE TECHO INDUSTRIAL DE 1 72 M Preguntas problemas o piezas faltantes Antes de regresar a la tienda llama al Servicio al Cliente de Hampton Bay de Lunes a Viernes entre 8 a m y 6 p m hora del Este de EE UU 1 877 527 0313 HOMEDEPOT COM GRACIAS POR TU COMPRA Apreciamos la confianza que has depositado en Hampton Bay al comprar este ventilador de techo Nos esforzamos para continuamente crear productos de calidad dise ados para tu hogar Vis tanos por Internet para ver nuestra linea completa de productos disponibles para las necesidades de mejoras de tu hogar Gracias por elegir Hampton Bay Tabla de Contenido Tabla de Contenido
22. rection of the blade rotation follow the instructions below Loosen the set screw MM on the coupler cover D Slide coupler cover D up to reveal the coupler J and reverse switch YY Set reverse switch YY in desired direction For warm weather set switch in down position For cool weather set switch in up position Warm weather Forward A downward airflow creates a cooling ef Cool weather Reverse An upward airflow moves warm air off of fect This allows you to set your air conditioner on a warmer setting the ceiling This allows you to set your heating unit on a cooler set without affecting your comfort ting without affecting your comfort 11 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Care and Cleaning WARNING Make sure the power is off before cleaning your fan Because of the fan s natural movement some connections may become loose Check the support connections brackets and blade attachments twice a year Make sure they are secure It is not necessary to remove the fan from the ceiling Clean your fan periodically to help maintain its new appearance over the years Do not use water when cleaning as this could damage the motor or the wood or possibly cause an electrical shock Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discol
23. ripci n Cantidad AA Tomillo para madera en formade J 1 BB Tornillo de montaje dela cubierta 4 Pe ere 0 montaje de la cubierta DD Conector pl stico para cable 6 FE Pemopaaganho 1 GG Tuerca hexagonal 1 HH Arandeladeseguridad 1 Pieza Descripci n Cantidad o 2 o u wem m ww s om memi Pre Instalaci n continuaci n CONTENIDO DEL PAQUETE Cantidad Soporte de montaje A Ensamblaje de tubo bajante bola D Tapa del acoplador IMPORTANTE Este producto y o sus componentes est n protegidos por una o m s de las siguientes Patentes 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 y otras patentes pendientes C Pieza Descripci n Cantidad 9 PF contr de pare i 1 HOMEDEPOT COM Para obtener asistencia llama al 1 877 527 0313 Instalaci n OPCIONES DE MONTAJE ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica o lesiones personales monta el ventilador sobre una caja el ctrica marcada como aprobada como soporte de ventiladores de 35 Ib 15 9 kg o menos y usa los tornillos de montaje que vienen con la misma Las cajas el ctricas utilizadas com nmente para el soporte de l mparas podr an no servir como soporte de ven
24. rol interruptor de pared ADVERTENCIA Para disminuir los riesgos de incendio descarga el ctrica o lesiones conecta un solo control interruptor de pared al ventilador de techo La conexi n de dos o m s ventiladores de techo a cualquier panel interruptor del control de pared puede recalentar y provocar fallas en los circuitos el ctricos No intentes ignorar esta caracter stica del sistema del ventilador de techo ya que hacerlo anular las estipulaciones de la garant a tanto expl citas como impl citas PRECAUCI N Para reducir el riesgo de lesiones usa s lo los tornillos incluidos con la caja el ctrica PRECAUCI N Para evitar lesiones f sicas o da os al ventilador y otros art culos ten cuidado al limpiar o trabajar cerca del ventilador Garant a El proveedor garantiza de por vida a partir de la fecha en que el comprador original lo adquiere que el motor del ventilador no presenta defectos de fabricaci n ni de material al momento en que es enviado desde la f brica El proveedor tambi n garantiza por un per odo de dos a os a partir de la fecha de compra por el comprador original que todas las dem s piezas del ventilador sin incluir ninguna aspa de vidrio o acr lico no presentar n ning n defecto de fabricaci n o de material desde el momento de su salida de la f brica Acordamos reparar todos los defectos del tipo antes mencionado sin cargo alguno o a nuestra discreci n reemplazar el producto por
25. t box and support structure must be securely mounted and capable of reliably supporting 35 pounds 15 9 kg Use only UL Listed outlet boxes marked Acceptable for Fan Support of 35 pounds 15 9 kg or less 3 The fan must be mounted with a minimum of 10 ft 3 m clearance from the trailing edge of the blades to the floor 4 Donotoperate the reversing switch while the fan blades are in motion You must turn the fan off and stop the blades before you reverse the blade direction 5 Do not place objects in the path of the blades 6 Electrical diagrams are for reference only 7 After making electrical connections spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box 8 All set screws must be checked and retightened where necessary before installation WARNING To reduce the risk of personal injury do not bend the blade brackets also referred to as flanges during assembly or after installation Do not insert objects in the path of the blades WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state speed control device WARNING To avoid possible electrical shock turn the electricity off at the main fuse box before wiring If you feel you do not have enough electrical wiring knowledge or experience contact
26. the fan motor black wire WW to the supply black wire WW using a wire connecting nut DD After connecting the wires spread them apart so that the green UU and white wires VV are one side of the outlet box XX and the black wire WW is on the other side Turn the wire connecting nuts upward and carefully push the wiring into the outlet box XX Assembly continued 1 0 Attaching the fan blades together at the factory The blades feature new technology for higher efficiency The blades are not reversible A NOTE The blade and blade arms are pre assembled Position the blade assembly E on the motor so the mounting screw holes align with the threaded holes Turn the screw JJ spring washer KK and flat washer LL into the hole but do not completely tighten Make sure the second hole in the blade assembly aligns with a hole in the motor housing G Install a second screw JJ spring washer KK and flat washer LL in the blade assembly in the same manner Repeat for the remaining blades Tighten all screws 10 Operation Install 4 speed wall control See the instructions enclosed with the wall control package Operating your fan A NOTE Wait for the fan to completely stop before setting the slide switch to reverse the direction of blade rotation The reverse switch is located on the coupler J To switch the di
27. tilador y tal vez deban reemplazarse En caso de duda consulta a un electricista calificado Si tu ventilador de techo no tiene una caja de montaje aprobada por UL instala una siguiendo las instrucciones a continuaci n Desconecta la energ a retirando los fusibles o apagando los cortacircuitos Asegura la caja el ctrica directamente a la estructura del edificio Usa sujetadores y materiales apropiados La caja el ctrica y su soporte deben sostener el peso completo del ventilador en movimiento al menos 35 Ib No uses una caja el ctrica de pl stico Las ilustraciones a continuaci n muestran tres formas diferentes de montar la caja el ctrica Caja El ctrica Dar Apoyo Estable Placa de Montaje de Techo Caja El ctrica Empotrada vez necesites un tubo bajante m s largo para mantener la altura m nima adecuada de las aspas al instalar el ventilador en un techo inclinado El ngulo m ximo permitido es de 30 de la posici n horizontal Barra Colgante Caja El ctrica Si la cubierta toca el tubo bajante retira la tapa inferior decorativa de la cubierta y gira la cubierta 180 antes de fijarla a la placa de montaje Para colgar el ventilador donde ya haya una l mpara pero ninguna viga de techo tal vez necesites una barra colgante como se muestra anteriormente disponible en cualquier tienda de The Home Depot Ensamblaje C mo desmantelar el ensambla
28. ts and turn clockwise to lock the canopy C in place Firmly tighten the two mounting screws BB with lock washer CC Install the remaining two mounting screws BB into the holes in the canopy C and tighten firmly T Connecting the safety cable Turn the wood screw AA into the ceiling Place the looped end of the safety cable K onto the wood screw AA and then tighten the screw firmly or connect the safety cable directly to the outer joist or mounting bracket A HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Assembly Hanging the Fan continued 0 Making the electrical connection WARNING Each wire not supplied with this fan is designed to accept up to one 12 gauge house wire and two wires from the AN fan If you have larger than 12 gauge house wiring or more than one house wire to connect to the fan wiring consult an electrician for the proper size wire nuts to use IMPORTANT Use the wire connecting nuts DD supplied with your fan Secure the connectors with electrical tape and ensure there are no loose strands or connections Connect the ground conductor of the 120 Volt supply this may be a bare wire or a wire with green colored insulation to the green ground lead s UU of the fan Connect the fan motor white wire VV to the supply white wire W using a wire connecting nut DD Connect
29. un modelo de calidad comparable o superior si el producto es devuelto Para obtener un servicio de garant a debe presentar una copia del recibo como comprobante de compra Todos los costos de retiro y reinstalaci n del producto son su responsabilidad Los da os a cualquiera de las piezas como resultado de accidentes instalaci n o uso incorrectos o debidos a la instalaci n de cualquier accesorio no est n cubiertos bajo esta garant a Debido a que las condiciones clim ticas pueden variar esta garant a no cubre ning n cambio en el acabado en bronce incluyendo xido perforaci n corrosi n manchas o descascaramiento Los acabados en bronce de este tipo tienen una vida til m s prolongada cuando se protegen de las condiciones clim ticas cambiantes Es normal cierta oscilaci n y no se considerar una falla Cualquier servicio t cnico conducido por personas no autorizadas anular la garant a No hay ninguna otra garant a expresa Mediante la presente Hampton Bay se exime de cualquier garant a incluyendo pero sin limitarse a aquellas de comercializaci n e idoneidad para un fin particular de acuerdo alo contemplado por la ley La duraci n de cualquier garant a impl cita de la cual no se pueda eximir est limitada al per odo de tiempo especificado en la garant a expl cita Algunos estados no permiten limitaciones en la duraci n de la garant a impl cita por consiguiente la limitaci n anterior puede no aplicarse a su cas
30. ure the hanger bolt EE using the flat washer FF lockwasher HH and the hexagonal nut GG Insert the split pin NN into the end of the hanger bolt EE and split the ends of the split pin NN apart to secure the hanger bolt EE Tighten the set screw ZZ firmly HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Assembly continued 3 Installing the coupler cover and canopy Slide the coupler cover D onto the downrod B and push the coupler cover D until it rests on the top of the motor housing G Tighten the set screw ZZ to secure the coupler cover D onto the downrod B Slide the canopy C onto the downrod B Assembly Hanging the Fan 5 Installing the mounting bracket WARNING The outlet box and support structure must be securely mounted and capable of reliably supporting 35 16 15 9 kg Use only UL Listed outlet boxes marked Acceptable for Fan Support of 35 Ibs 15 9 kg or less Pass the 120 Volt supply wires through the center hole in the mounting bracket A Install the ceiling mounting plate on the outlet box by sliding the mounting bracket A over the two screws TT provided with the outlet box If necessary use leveling washers not included be tween the mounting bracket A and the outlet box Note that the flat side of the mounting bracket A is toward the outlet box Securely tighten the two mounting screws

Download Pdf Manuals

image

Related Search

Related Contents

Bautier Elisabeth - PU  manuale d`installazione  Samsung GT-C6112 Керівництво користувача  READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE  USER MANUAL - Kramer Electronics  ポータブルマルチメータ HQ30d/40d  Thèmes des projets  Norcent Technologies VION LT-3290 User's Manual  Korg DIGITAL PIANO E F G 1 User's Manual  