Home
none 82392057664 Use and Care Manual
Contents
1. 11 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Operation Turn on the power and check the operation of the fan The pull chain controls the fan speeds as follows 1 pull High 2 pulls Medium 3 pulls Low 4 pulls off The appropriate speed settings for warm or cool weather depends on factors such as the room size ceiling height and number of fans The slide switch controls the direction of the blades forward switch left or reverse switch right NOTE Wait for the fan to stop before reversing the direction of blade rotation Warm weather Forward A downward airflow creates a cooling ef fect This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Reverse An upward airflow moves warm air off of the ceiling This allows you to set your heating unit on a cooler set ting without affecting your comfort 12 Care and Cleaning WARNING Make sure the power is off before cleaning your fan Because of the fan s natural movement some connections may become loose Check the support connections brackets and blade attachments twice a year Make sure they are secure It is not necessary to remove the fan from the ceiling Clean your fan periodically to help maintain its new appearance over the years Do not use water when cleaning as this could damage the motor or the wood or possi
2. e Outlet Box Provide Strong Support Recessed Ceiling Outlet Mounting Plate Box NOTE You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 30 away from horizontal Hanger Bar Outlet Box If the canopy touches the downrod then remove the decorative canopy bottom cover and turn the canopy 180 before attaching the canopy to the mounting plate To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown above available at any Home Depot store Assembly Standard Ceiling Mount Preparing for mounting Remove the canopy ring K from the canopy C by turning the ring to the right until it unlocks Remove the mounting plate A from the canopy C by loosening the four screws on the top of the canopy C Remove the two non slotted screws and loosen the slotted screws This will enable you to remove the mounting bracket A 3 Assembling the fan WARNING Failure to properly install the locking pin could result in the fan becoming loose and possibly falling Loosen but do not remove the setscrew PP on the collar on top of the motor housing D Align the holes at the bottom of the downrod B with the holes in the collar on top of the motor housing D
3. coloca el cableado dentro de la caja el ctrica NN Conecta el conductor a tierra del cable de 120 Voltios puede ser un cable desnudo o un cable con aislante verde al los cable s terminal es a tierra verde s JJ del ventilador Cuando uses el montaje de techo est ndar habr dos cables terminales a tierra verdes uno desde el soporte de montaje de techo y otro desde el ensamblado del tubo bajante bola Cuando uses el montaje cerca del techo habr solamente un cable a tierra verde del soporte de montaje de techo esto se debe a que el ensamblado del tubo Conecta el cable blanco del motor del ventilador MM al cable blanco de suministro neutro MM usando una tuerca de conexi n Conecta el cable de suministro azul de la luz del ventilador KK y el cable negro del motor LL al cable negro de suministro de ener g a positivo LL usando una tuerca de conexi n de cables BB Despu s de conectar los cables sep ralos de manera que los ca bles verde JJ y blanco MM queden de un lado de la caja el ctrica Gira las tuercas de conexi n del cable hacia arriba y con cuidado NN LL MM HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 7 C mo montar el ventilador ADVERTENCIA Cuando uses el ensamblaje del tubo bajante bola est ndar la pesta a en el aro en la parte inferior del soporte de
4. Carefully insert the hanger pin CC through the holes in the collar and downrod B Be careful not to jam the hanger pin DD against the wiring inside the downrod B Insert the locking pin DD through the hole near the end of the hanger pin CC until it snaps into its locked position Re tighten the setscrew PP on the collar on top of the motor housing D 2 Routing the wires Route the wires exiting the top of the fan motor D into the decorative motor collar cover F and through the canopy ring K Make sure the slot openings are on top and route the wires through the canopy C and then through the ball downrod assembly B HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance 1 Close to Ceiling Mounting Remove the canopy ring K from the canopy C by turning the ring to the right until it unlocks Remove the mounting bracket A from the canopy C by loosening the four screws on the top of the canopy C Remove the two non slotted screws and loosen the slotted screws Remove the decorative canopy bottom cover L from the canopy C by depressing the three studs Assembly Hanging the Fan Attaching the fan to the electrical box WARNING To reduce the risk of fire electric shock or personal injury mount to outlet box marked Acceptable for fan support of 35105 15
5. rate de que tu caja el ctrica y las almohadillas aislantes de goma sean instaladas entre la placa de montaje y la caja el ctrica El ventilador oscila Verifica que todos los tornillos de las aspas y de los brazos de las aspas est n seguros La mayor a de los problemas de oscilaci n del ventilador se deben a que las aspas no est n a un mismo nivel Verifica que est n niveladas seleccionando un punto en el techo sobre la punta de una de las aspas Mide desde un punto en el centro del aspa hasta punto en el techo Gira el ventilador hasta que la pr xima aspa quede posicionada para medir y mide desde el mismo punto en cada aspa hasta el techo Repite este proceso para cada aspa Las desviaciones de medici n no deben ser mayores a 1 8 plg 3 17 mm Enciende el ventilador durante diez minutos 13 HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Preguntas problemas o piezas faltantes Antes de regresar a la tienda llama al Servicio al Cliente de Hampton Bay de Lunes a Viernes entre 8 a m y 6 p m hora Est ndar del Este de EE UU 1 877 527 0313 HAMPTONBAY COM Conserva este manual para usarlo en el futuro
6. blade and blade arm screws are secure Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure from a point on the center of the blade to the point on the ceiling Rotate the fan until the next blade is positioned for measurement and measure from the same point on each blade to the ceiling Repeat for each blade Any measurement deviation should be within 1 8 in Run the fan for ten minutes 13 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HAMPTONBAY COM Retain this manual for future use Art culo N m 795 838 795 871 795 904 850 919 850 193 Modelo N m 51012 51013 51014 51090 51091 Modelo N m 52 CCT Aprobado por UL GU A DE USO Y MANTENIMIENTO VENTILADOR DE TECHO LYNDHURST DE 52 PLG 1 32 M Preguntas problemas o piezas faltantes Antes de regresar a la tienda llama al Servicio al Cliente de Hampton Bay de Lunes a Viernes entre 8 a m y 6 p m hora del Este de EE UU 1 877 527 0313 HAMPTONBAY COM GRACIAS POR TU COMPRA Apreciamos la confianza que has depositado en Hampton Bay al comprar este ventilador de techo Nos esforzamos para continuamente crear productos de calidad dise ados para tu h
7. c lido o fr o dependen de factores como el tama o de la habitaci n la altura del techo y la cantidad de ventiladores El interruptor deslizante controla la direcci n de las aspas hacia adelante interruptor hacia la izquierda o reversa interruptor hacia la derecha NOTA Espera a que se detenga el ventilador antes de invertir la direcci n de giro de las aspas Clima c lido Hacia adelante Un flujo de aire hacia abajo crea un efecto refrescante Esto te permite fijar tu aire acondicionado a una temperatura m s alta sin afectar tu comodidad Clima fr o Reversa Un flujo de aire hacia arriba mueve el aire c lido lejos del techo Esto te permite fijar tu unidad de calefacci n en una configuraci n m s fr a sin afectar tu comodidad 12 EE M Mantenimiento y Limpieza ADVERTENCIA Aseg rate de que la corriente est cortada antes de limpiar el ventilador Debido al movimiento natural del ventilador algunas conexiones pueden aflojarse Revisa las conexiones de soporte los soportes y los accesorios de las aspas dos veces al a o Verifica que est n seguros No es necesario desmontar el ventilador del techo Limpia el ventilador con frecuencia para que luzca como nuevo con el pasar de los a os No uses agua al limpiar ya que esto puede da ar el motor o la madera o puede causar descargas el ctricas Usa solamente un cepillo suave o un pa o sin pelusas para evitar arafiar el acab
8. forzar el pasador de soporte CC contra el cableado dentro del tubo bajante B Inserta el pasador de cierre DD en el orificio cercano al extremo del pasador de soporte CC hasta que quede encajado en su posici n Vuelve a apretar el tornillo de fijaci n PP del collar n ubicado en la parte superior de la carcasa del motor D 7 HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 1 Montaje Cerca del Techo Retira el aro K de la cubierta C gir ndolo hacia la derecha hasta soltarlo Retira el soporte de montaje A de la cubierta C aflojando los cuatro tornillos en la parte superior de la cubierta C Quita los dos tornillos sin ranura y afloja los tornillos ranurados Retira la cubierta inferior decorativa de la cubierta L de la cubierta C oprimiendo los tres pernos C mo instalar el ventilador en la caja el ctrica ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica o lesiones personales monta el ventilador sobre una caja el ctrica marcada como aprobada como soporte de ventiladores de 35 Ib 15 9kg o menos y usa los tornillos de montaje que vienen con la misma Pasa los cables de suministro de 120 Voltios a trav s del orificio central en el soporte de montaje A Instala el soporte de montaje de techo sobre la caja el ctrica deslizando el
9. montaje debe encajar en la ranura de la bola de soporte Si la pesta a no se asienta correctamente en la ranura se puede da ar el cableado Alinea las ranuras de cierre de la cubierta de techo C con los dos tornillos del soporte de montaje A Empuja hacia arriba para enganchar en las ranuras y gira de izquierda a derecha para asegurar la cubierta C en su sitio Ajusta firmemente los dos tornillos de montaje M Instala los dos tornillos de montaje restantes M en los orifi cios de la cubierta C y aprieta firmemente Instala el aro de cubierta decorativo K alineando las ranuras del aro con los tornillos en la cubierta C Rota el aro en sentido contrario a las manecillas del reloj para fijarlo A M 8 Como montar las aspas del ventilador A NOTA Las aspas de tu ventilador son reversibles Elige el acabado del aspa que mejor resalte tu decoraci n Fija el aspa G a su soporte H con los tornillos provistos AA Observa que las arandelas de goma est n fijadas en el soporte del aspa H Inserta el tornillo en el soporte del aspa H Repite para los otros dos tornillos AA Aprieta todos los tornillos firmemente Ajusta el ensamblaje del aspa al motor insertando los postes de alineaci n dentro de la ranura de la parte inferior del motor y aprieta los tornillos del motor Por favor ten en cuenta que los tornillos del motor est n preinstalados en el brazo del aspa Repite los pasos 1 3 para las aspas re
10. no aplicarse a su caso El minorista no ser responsable por da os directos indirectos o especiales que resulten o deriven del uso o rendimiento del producto excepto en casos en que lo estipule la ley Algunos estados no permiten la exclusi n o limitaci n de da os directos o indirectos por lo que la limitaci n o exclusi n anterior podr a no aplicarse a su caso Esta garant a le otorga derechos legales espec ficos y es posible que tambi n tenga otros derechos que var an de un estado a otro Esta garant a sustituye todas las garant as anteriores Los costos de env o de cualquier devoluci n de productos hecha como parte de una reclamaci n de garant a est n a cargo del cliente Comun quese con el Equipo de Servicio al Cliente al 1 877 527 0313 o visite www HamptonBay com Preinstalaci n ESPECIFICACIONES PIES Peso pao am Meda od 1 32 m 3174 NOTA Estas medidas son aproximadas No incluyen ni el Amperaje ni el Vataje consumido por el kit de luces HERRAMIENTAS NECESARIAS Destornillador Destornillador Llave Cinta de Lh I hh Cortacables Phillips plano ajustable electricista Escalera 3 HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Preinstalaci n continuaci n HERRAJES INCLUIDOS NOTA No se muestra el tama o real de los herrajes Doa APTO EE ac ES GG FF Pieza Descripci n Cantidad Cant
11. se muestra puede romperse el gancho y el ventilador se caera El gancho debe pasar de adentro hacia fuera de la cubierta ADVERTENCIA El gancho usado como se muestra es s lo para Con cuidado alza el ensamblaje del motor del ventilador D hasta el soporte de montaje A Coloca la bola de soporte del ensamblaje del tubo bajante bola B en el soporte de montaje Aseg rate de que la pesta a sobre el soporte de montaje A encaje bien dentro de la ranura de la bola de soporte Si vas a usar el montaje cerca del techo cuelga el ventilador del gancho suministrado usando uno de los orificios en el borde exterior de la cubierta de techo C 6 C mo hacer las conexiones el ctricas ADVERTENCIA Cada cable no suministrado con este ventilador est dise ado para aceptar un m ximo de un solo circuito el ctrico dom stico de calibre 12 y dos cables del ventilador Si tienes un cableado dom stico de calibre superior a 12 o vas a conectar m s de un cable dom stico al sistema de cableado del ventilador consulta con un electricista acerca del tama o adecuado de las tuercas para cable IMPORTANTE Usa las tuercas de conexi n de cables BB que vienen con tu ventilador Sujeta los conectores con cinta de electricista y aseg rate de que no haya conexiones o cables sueltos bajante bola no se utiliza de cables BB NN y el cable negro LL del otro
12. to the motor by inserting the alignment post into the slot on the bottom of the motor and tighten the motor screws Please note that the motor screws are pre attached into the blade arm Repeat steps 1 3 for the remaining blades 10 Assembly Attaching the Light Kit 0 Attaching the light kit 1 Attaching the glass shades and bulbs CAUTION To reduce the risk of electric shock disconnect _ A the electrical supply circuit to the fan before installing the CAUTION Make sure the power is off before attaching or light kit removing the glass shades Remove the three screws QQ from the black bracket below the fan motor assembly D WARNING Allow the glass shade to cool completely before removing Connect the wires exiting the bottom of the motor assembly D by connecting the molded adaptor plugs SS together Slide the switch cup light kit E and secure it to the black bracket using the three screws QQ that were removed in the first step Insert the glass shade I into the glass holder by carefully squeezing the steel tensioners TT on the light fixture together Gently slide the glass shade over the steel tensioners TT Make sure the glass shade is fully inserted into the socket for a secure fit Repeat for the remaining glass shades With the power off install the light bulbs J Max 14W provided into the light bulb sockets
13. 9kg or less and use screws provided with the outlet box Pass the 120 Volt supply wires through the center hole in the mounting bracket A Install the ceiling mounting bracket on the outlet box by sliding the mounting bracket A over the two screws UU provided with the outlet box If necessary use leveling washers not included between the mounting bracket A and the outlet box Note that the flat side of the mounting bracket A is toward the outlet box When using close to ceiling mounting it is important that the mounting bracket be level Securely tighten the two mounting screws UU Assembly Close To Ceiling Mount 2 Routing the wires Remove three of the six screws and lock washers every other one securing the motor collar M to the top of the fan motor housing D Place the rubber gasket EE over the remaining three screws route the wires exiting the top of the fan motor through the canopy ring K make sure the slot opening is on top then proceed to place the ceiling canopy C over the collar at the top of the motor D Align the mounting holes with the holes in the motor D and fasten using the three screws and lock washers removed previously Tighten the mounting screws securely Assembly Hanging the Fan continued 5 Hanging the fan attaching wiring Failure to hang as shown may result in hook breaking causing the fan to fall The hook must p
14. Item 795 838 795 871 795 904 850 919 850 193 Model 51012 51013 51014 51090 51091 UL model 52 CCT USE AND CARE GUIDE LYNDHURST 52 INCH CEILING FAN Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HAMPTONBAY COM THANK YOU We appreciate the trust and confidence you have placed in Hampton Bay through the purchase of this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay Table of Contents Table of Contents eee 2 Safety Information e eecce ceca corso nnndnnnasiancecienen 2 Warranty eee 3 Pre Installation nia aa ianua axungia o cauia 3 Installation eene eee eere eene nnns 6 A m Q 7 PPP y A 12 Care and 13 Troubleshooting eene otn nna annue 13 Safety Information j All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 1999 and local electrical codes Electrical installation should be performed by a qualified licensed electrici
15. ado El revestimiento est sellado con laca para minimizar la decoloraci n u opacidad Para mayor protecci n y belleza puedes aplicar a la madera una fina capa de pulimento para muebles Cubre los ara azos peque os con una leve aplicaci n de lustrador para calzado El ventilador no necesita lubricaci n El motor tiene cojinetes de bola sellados que est n permanentemente lubricados Soluci n de Problemas Problema Soluci n ss El ventilador Revisa los fusibles o disyuntores principales y secundarios no enciende Verifica las conexiones de cables en l nea al ventilador y las conexiones de cables del interruptor en la caja de interruptores El ventilador Aseg rate de que los tornillos de la carcasa del motor est n ajustados hace ruido Aseg rate de que los tornillos que unen el soporte de aspa al cuerpo del motor est n bien ajustados Aseg rate de que los empalmes de pl stico no choquen unos con otros o con la pared interior de la caja del interruptor Permite un per odo de 24 horas de adaptaci n La mayor a de los ruidos asociados con un ventilador nuevo desaparecen en ese per odo Si usas el kit de luces de Ventilador de Techo aseg rate de que los tornillos que sujetan el vidrio est n bien colocados Verifica que las bombillas est n bien aseguradas Aseg rate de que la cubierta est a corta distancia del techo No debe tocar el techo Aseg
16. alling the blades or testing the motor shock do not use this fan with any solid state speed control device WARNING To reduce the risk of fire or electric WARNING To reduce the risk of fire electric shock or personal injury mount to outlet box marked Acceptable for fan support of 35lbs 15 9kg or less and use screws provided with the outlet box WARNING To avoid possible electrical shock turn the electricity off at the main fuse box before wiring If you feel you do not have enough electrical wiring knowledge or experience contact a licensed electrician use only the screws provided with the outlet box AN CAUTION To reduce the risk of personal injury CAUTION To avoid personal injury or damage to the fan and other items use caution when working around or cleaning the fan Warranty The supplier warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a lifetime after the date of purchase by the original purchaser The supplier also warrants that all other fan parts excluding any glass or acrylic blades to be free from defects in workmanship and material at the time of shipment from the factory for a period of one year after the date of purchase by the original purchaser We agree to correct such defects without charge or at our option replace with a comparable or superior model if the product is returned To obtain w
17. an The outlet box and support structure must be securely mounted and capable of reliably supporting 35 Ibs 15 9kg Use only UL Listed outlet boxes marked Acceptable for Fan Support of 35 Ibs 15 9kg or less The fan must be mounted with a minimum of 7 ft 2 m clearance from the trailing edge of the blades to the floor Do not operate the reversing switch while the fan blades are in motion You must turn the fan off and stop the blades before you reverse the blade direction Do not place objects in the path of the blades Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL Listed and marked suitable for use with the model fan you are installing Switches must be UL General Use Switches Refer to the instructions packaged with the light kits and switches for proper assembly After making electrical connections spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box All set screws must be checked and retightened where necessary before installation WARNING To reduce the risk of personal injury do not bend the blade brackets also referred to as flanges during assembly or after installation Do not insert objects in the path of the blades WARNING Remove the rubber motor stops on the bottom of the fan before inst
18. arranty service you must present a copy of the receipt as proof of purchase All costs of removing and reinstalling the product are your responsibility Damage to any part such as by accident or misuse or improper installation or by affixing any accessories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not allow a limitation on how long an implied warranty lasts so the above limitation may not apply to you The retailer shall not be liable for incidental consequential or special damages arising out of or in connection with product use or performance except as may otherwise be accorded by law Some states do not allow the exclusion of incidental or consequential damages so the above exclusion or limit
19. ass from inside to the outside of the canopy Carefully lift the fan motor assembly D up to the mounting bracket A WARNING The hook as shown is only to balance the fan while in the mounting bracket socket Ensure that the tab on the mounting bracket A socket is properly seated in the groove in the hanger ball If using close to ceiling mounting hang the fan on the hook provided by utilizing one of the holes at the outer rim of the ceiling canopy C 6 Making the electrical connection WARNING Each wire not supplied with this fan is designed to accept up to one 12 gauge house wire and two wires from the fan If you have larger than 12 gauge house wiring or more than one house wire to connect to the fan wiring consult an electrician for the proper size wire nuts to use IMPORTANT Use the wire connecting nuts BB supplied with your fan Secure the connectors with electrical tape and ensure there are no loose strands or connections Connect the ground conductor of the 120 Volt supply this may be a bare wire or a wire with green colored insulation to the green ground lead s JJ of the fan When using stan dard ceiling mounting there are two green grounding leads one from the ceiling mounting bracket and one from the ball downrod assembly When using close to ceiling mount ing there is only one green grounding lead from the ceiling mounting bracket sine the ball downrod assembl
20. ation may not apply to you This warranty gives specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties Shipping costs for any return of product as part of a claim on the warranty must be paid by the customer Contact the Customer Service Team at 1 877 527 0313 or visit www HamptonBay com Pre Installation SPECIFICATIONS e m DR om jee 23 1 Ibs 25 5 Ibs 10 5 kg 11 6 kg m NOTE These are approximate measures They do not U L include the Amps and Wattage used by the light kit amp TOOLS REQUIRED Flat blade Adjustable Electrical A screwdriver wrench O tape Step ladder CD philips screwdriver 3 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Pre Installation continued HARDWARE INCLUDED A NOTE Hardware not shown to actual size Doa APTO A EE ac ES 86 FF Pat Description Quantity Blade attachment screws Rubber gasket for close to ceiling Wire connecting nut mounting lina 0 Locking pin Pre Installation continued PACKAGE CONTENTS LJ A Pat Description Quantity ES Slide on mounting bracket inside canopy B Ball downrod assembly Canopy with canopy ring attached D favmotorassembly IMPORTANT This product and or components are governed by one
21. bly cause an electrical shock Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing You can apply a light coat of furniture polish to the wood for additional protection and enhanced beauty Cover small scratches with a light application of shoe polish You do not need to oil your fan The motor has permanently lubricated sealed ball bearings Troubleshooting Problem Solution ss The fan will not start Check the main and branch circuit fuses or breakers Check the line wire connections to the fan and switch wire connections in the switch housing The fan is noisy Ensure all motor housing screws are snug Ensure the screws that attach the fan blade bracket to the motor hub are tight Ensure the wire nut connections are not rattling against each other or the interior wall of the switch housing Allow a 24 hour breaking in period Most noises associated with a new fan disappear during this time If you are using the Ceiling Fan light kit ensure the screws securing the glassware are tight Check that the light bulbs are also secure Ensure the canopy is a short distance from the ceiling It should not touch the ceiling Ensure your outlet box is secure and rubber isolator pads were used between the mounting plate and outlet box The fan wobbles Check that all
22. ci n reemplazar el producto por un modelo de igual calidad o superior si el producto es devuelto Para obtener un servicio de garant a debe presentar una copia del recibo como comprobante de compra Todos los costos de retiro y reinstalaci n del producto son su responsabilidad Los da os a cualquiera de las piezas como resultado de accidentes instalaci n o uso incorrectos o debidos a la instalaci n de cualquier accesorio no est n cubiertos bajo esta garant a Debido a que las condiciones clim ticas pueden variar esta garant a no cubre ning n cambio en el acabado en bronce incluyendo xido perforaci n corrosi n manchas o descascaramiento Los acabados en bronce de este tipo tienen una vida til m s prolongada cuando se protegen de las condiciones clim ticas cambiantes Es normal cierta oscilaci n y no se considerar una falla Cualquier servicio t cnico realizado por personas no autorizadas invalidar la garant a No hay ninguna otra garant a expresa Mediante la presente Hampton Bay se exime de cualquier garant a incluyendo pero sin limitarse a aquellas de comercializaci n e idoneidad para un fin particular de acuerdo a lo contemplado por la ley La duraci n de cualquier garant a impl cita que no se pueda eximir est limitada al per odo de tiempo especificado en la garant a expl cita Algunos estados no permiten limitaciones en la duraci n de la garant a impl cita por consiguiente la limitaci n anterior puede
23. el ventilador y detener las aspas antes de invertir la direcci n de las aspas 5 No coloques objetos en la trayectoria de las aspas 6 Los diagramas el ctricos son solo para referencia Los kits de luces no empaquetados con el ventilador deben estar aprobados por UL y marcados como apropiados para ser usados con el modelo de ventilador a instalar Los interruptores deber n estar clasificados por UL como de Uso General Consulta las instrucciones adjuntas a los kits de luces e interruptores para obtener informaci n sobre el montaje adecuado 7 Despu s de concluir las conexiones el ctricas debes voltear los conductores empalmados hacia arriba y meterlos con cuidado en la caja el ctrica Los cables deben estar separados con el cable a tierra y el conductor a tierra del equipo en uno de los lados de la caja el ctrica 8 Todos los tornillos de fijaci n se deben verificar y ajustar donde sea necesario antes de la instalaci n ADVERTENCIA Para reducir el riesgo de lesiones personales no dobles los soportes de las aspas tambi n llamados bridas durante o despu s de la instalaci n No coloques objetos en la trayectoria de las aspas ADVERTENCIA Retira los topes de goma del motor en la parte inferior del ventilador antes de instalar las aspas o probar el motor ADVERTENCIA Para reducir el riesgo de incendio o descarga el ctrica no utilices este ventilador con ning n dispositivo de control de velocidad de estado s lid
24. idad Tornillos para el montaje de aspas EX Junta de goma para montaje EON Tuerca para conectar cable cerca del techo Pasador de soporte Ka Tornillo adicional para soporte DD Pasadordeciere 1 ii Preinstalaci n continuaci n CONTENIDO DEL PAQUETE LJ A Pieza Descripci n Cantidad ES Soporte deslizante para montaje dentro de la cubierta B Ensamblaje de tubo bajante bola Cubierta con aro incorporado D Ensamblaje del motor del ventilador IMPORTANTE Este producto y o sus componentes est n protegidos por una o m s de las siguientes Patentes de los EE UU 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 y otras patentes pendientes Ensamblaje del soporte del kit de luces F Cubierta decorativa del collar n del motor H Soporte de aspa Ft Pantalla de vidrio J Cantidad Bombilla CFL maximo de 14 Watts HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Instalaci n OPCIONES DE MONTAJE ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica o lesiones personales monta el ventilador sobre una caja el ctrica marcada como aprobada como soporte de ventiladores de 35 Ib 15 9kg o menos y usa los tornillos de montaje que vienen con la misma Las cajas el ctricas utilizadas com nmente para el soporte de l mparas podr an no servir como soporte de ventilador y tal vez deban
25. locking slots of the ceiling canopy with the two align the locking slots of the ceiling canopy C with the two screws in the mounting bracket A Push up to engage the screws in the mounting bracket A Push up to engage the slots and turn clockwise to lock the canopy C in place slots and turn clockwise to lock the canopy C in place Im Firmly tighten the two mounting screws M mediately tighten the two mounting screws M firmly Install the remaining two mounting screws M into the holes Install the remaining two mounting screws M into the holes in the canopy C and tighten firmly in the canopy C and tighten firmly Install the decorative canopy ring K by aligning the ring s Install the decorative canopy ring K by aligning the ring s slots with the screws in the canopy C Rotate the ring slots with the screws in the canopy C Rotate the ring counter clockwise to lock it in place counter clockwise to lock it in place A M i PLAY K C C D D Assembly Attaching the Fan Blades 8 Attaching the fan blades NOTE Your fan blades are reversible Select the blade side finish which best accentuates you decor Attach blade G to blade bracket H using the screws AA provided Please note that the rubber washers are pre attached to the blade bracket H Insert a screw into the blade bracket H Repeat for the two remaining screws AA Tighten each screw securely Fasten the blade assembly
26. o ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica o lesiones personales monta el ventilador sobre una caja el ctrica marcada como aprobada como soporte de ventiladores de 35 Ib 15 9kg o menos y usa los tornillos de montaje que vienen con la misma ADVERTENCIA Para evitar una posible descarga el ctrica corta la energ a el ctrica en la caja principal de fusibles antes de instalar el cableado Si crees que no tienes suficiente experiencia o conocimientos sobre el cableado el ctrico contacta a un electricista certificado PRECAUCI N Para reducir el riesgo de lesiones usa s lo los tornillos incluidos con la caja el ctrica PRECAUCI N Para evitar lesiones f sicas o dafios al ventilador y otros art culos ten cuidado al limpiar o trabajar cerca del ventilador Garant a El proveedor garantiza de por vida a partir de la fecha en que el comprador original lo adquiere que el motor del ventilador no presenta defectos de fabricaci n ni de material al momento en que es enviado desde la f brica El proveedor tambi n garantiza por el per odo de un a o a partir de la fecha de compra por el comprador original que las dem s piezas del ventilador sin incluir ninguna aspa de vidrio o acr lico no presentar n ning n defecto de fabricaci n o de material en el momento de la salida de la f brica Acordamos reparar todos los defectos del tipo antes mencionado sin cargo alguno o a nuestra discre
27. o antes de instalar el kit de luces Quita los tres tornillos QQ del soporte negro debajo del ensamblaje del motor del ventilador D ADVERTENCIA Espera que la pantalla de vidrio se enfr e AM completamente antes de retirarla Conecta los cables que salen de la parte inferior del ensamblaje del motor D uniendo los enchufes con adaptadores moldeados SS Desliza el kit de luces con caja de interruptor E y aseg ralo al soporte negro usando los tres tornillos QQ que se quitaron en el paso 1 Inserta la pantalla de vidrio I en el soporte de vidrio apretando con cuidado los tensores de acero TT sobre la l mpara Cuidadosamente desliza la pantalla de vidrio I sobre los tensores de acero TT Aseg rate de que la pantalla de vidrio est totalmente insertada en el portabombillas para una colocaci n segura Repite para las pantallas de vidrio restantes Con la electricidad apagada instala las bombillas fluorescentes J de 14 W M ximo incluidas en los portabombillas 11 HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Funcionamiento Conecta la electricidad y verifica el funcionamiento del ventilador La cadena para halar controla las velocidades del ventilador de la siguiente manera 1 vez Alto 2 veces Medio 3 veces Bajo 4 veces Apagado Las configuraciones de velocidad apropiadas para clima
28. ogar Vis tanos por Internet para ver nuestra l nea completa de productos disponibles para las necesidades de mejoras de tu hogar Gracias por elegir Hampton Bay Tabla de Contenido Tabla de Contenido eese nere 2 Informaci n de Seguridad 2 CECI cc rr 3 Preinstalaci n carr 3 Instalaci ns 6 Ensamblaje 7 Funcionamiento anui ca ka ausa nia daa usa A nas rancia 12 Mantenimiento y 13 Soluci n de Problemas eene 13 Informaci n de Seguridad 1 Todo el cableado debe cumplir con el C digo Nacional de Electricidad ANSI NFPA 70 1999 y con los c digos locales de electricidad La instalaci n el ctrica debe ser hecha por un electricista certificado y calificado 2 Lacaja el ctrica y estructura de soporte deben montarse de forma segura y tener capacidad para sostener de manera confiable un m nimo de 35 Ib 15 9 kg Usa solamente cajas el ctricas aprobadas por UL marcadas como Para Soporte de Ventilador 3 Elventilador debe ir montado con un m nimo de 7 pies 2 m de separaci n entre el borde trasero de las aspas y el piso 4 No muevas el interruptor de reversa mientras las aspas del ventilador est n en movimiento Debes apagar
29. olgante como se mostr anteriormente disponible en cualquier tienda de The Home Depot Ensamblaje Montaje Est ndar en Techo 1 Preparaci n para el montaje 2 Disposicion de los cables Retira el aro K de la cubierta C girandolo hacia la derecha Inserta los cables que salen por la parte superior del hasta soltarlo motor del ventilador D en la cubierta decorativa del Retira la placa de montaje A de la cubierta C collar n del motor F y a trav s del aro de la cubierta K aflojando los cuatro tornillos en la parte superior de la Aseg rate de que las ranuras est n en la parte superior cubierta C y pasa los cables a trav s de la cubierta C y luego a Quita los dos tornillos sin ranura y afloja los tornillos trav s del ensamblaje del tubo bajante bola B ranurados Esto te permitir retirar el soporte de montaje A 3 C mo ensamblar el ventilador ADVERTENCIA Si no instalas correctamente el pasador de cierre es posible que el ventilador se afloje y caiga Afloja sin quitar los tornillos PP del collar n ubicados en la parte superior de la carcasa de motor D Alinea los orificios en la parte inferior del tubo bajante B con los orificios en el collar n de la parte superior de la carcasa de motor D Inserta con cuidado el pasador de soporte CC a trav s de los orificios del collar n y del tubo bajante B Ten cuidado de no
30. or more of the following U S Patents 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 and other patents pending B Pat Description Quantity tint fterassemby 1 7 TF Decorative motor colar cover 1 pe Hate aer ss ade watts ma CFL bulb 14 watts maximum HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Installation MOUNTING OPTIONS WARNING To reduce the risk of fire electric shock or personal injury mount to outlet box marked Acceptable for fan support of 35165 15 9kg or less and use screws provided with the outlet box An outlet box commonly used for the support of lighting fixtures may not be acceptable for fan support and may need to be replaced If in doubt consult a qualified electrician If your ceiling fan does not have an existing UL listed mounting box then install one using the following instructions Disconnect the power by removing the fuses or turning off the circuit breakers Secure the outlet box directly to the building structure Use the appropriate fasteners and materials The outlet box and support structure must be securely mounted and capable of reliably supporting 35 Ibs 15 9kg Use only UL Listed outlet boxes marked Acceptable for Fan Support of 35 Ibs 15 9kg or less Do not use a plastic outlet box The illustrations below show three different ways to mount the outlet box
31. ser reemplazadas En caso de duda consulta a un electricista calificado Si tu ventilador de techo no tiene una caja de montaje aprobada por UL inst lala siguiendo las instrucciones a continuaci n Desconecta la energ a retirando los fusibles o apagando los cortacircuitos Fija la caja el ctrica directamente a la estructura del edificio Usa sujetadores y materiales apropiados La caja el ctrica y estructura de soporte deben montarse de forma segura y tener capacidad para sostener de manera confiable 35 Ib Usa solamente cajas el ctricas aprobadas por UL marcadas como Aprobada como soporte de ventiladores de 35 Ib 15 9kg o menos No uses una caja el ctrica de pl stico Las ilustraciones a continuaci n muestran tres formas diferentes de montar la caja el ctrica El ctrica e Caja El ctrica Soporte Caja Placa El ctrica de Montaje del Techo Empotrada NOTA Tal vez necesites un tubo bajante m s largo para mantener la altura m nima adecuada de las aspas al instalar el ventilador en un techo inclinado El ngulo m ximo permitido es de 30 de la posici n horizontal Barra para Colgar Caja El ctrica Si la cubierta toca el tubo bajante retira la tapa inferior decorativa de la cubierta y gira la cubierta 180 antes de fijarla a la placa de montaje Para colgar el ventilador donde ya haya una l mpara pero ninguna viga de techo tal vez necesites una barra c
32. soporte de montaje A sobre los dos tornillos UU suministrados con la caja el ctrica Si es necesario usa arandelas niveladoras no incluidas entre el soporte de montaje A y la caja el ctrica Fijate que el lado plano del soporte de montaje A est hacia la caja el ctrica Cuando uses el montaje cerca del techo es importante que el soporte de montaje est nivelado Ajusta firmemente los dos tornillos de montaje UU Ensamblaje Montaje Cerca del Techo 2 Disposicion de los cables Retira tres de los seis tornillos y arandelas de seguridad alternados que sujetan el collarin del motor M a la parte superior de la carcasa del motor del ventilador D Coloca la junta de goma EE sobre los tres tornillos restantes pasa los cables que salen de la parte superior del motor del ventilador a trav s del aro de la cubierta K aseg rate de que las aberturas de las ranuras miren hacia arriba y luego coloca la cubierta de techo C sobre el collar n en la parte superior del motor D Alinea los orificios de montaje con los orificios del motor D y asegura con los tres tornillos y las arandelas de seguridad que retiraste anteriormente Ajusta bien los tornillos de montaje Ensamblaje C mo Colgar el Ventilador Ensamblaje C mo Colgar el Ventilador continuaci n 5 Como colgar el ventilador sostener el ventilador mientras se conectan los cables Si no se cuelga como
33. stantes Ensamblaje C mo Colgar el Ventilador continuaci n Montaje Cerca del Techo ADVERTENCIA Las ranuras de encaje de la cubierta del techo solo sirven de ayuda durante el montaje No dejes de supervisar el ensamblaje del ventilador hasta que los cuatro tornillos de la cubierta se fijen y ajusten firmemente Con cuidado desengancha el ventilador del soporte de mon taje A y alinea las ranuras de cierre de la cubierta del techo C con los dos tornillos en el soporte de montaje A Empuja hacia arriba para enganchar en las ranuras y gira de izquierda a derecha para asegurar la cubierta C en su sitio Ajusta in mediatamente y con firmeza los dos tornillos de montaje M Instala los dos tornillos de montaje restantes M en los orifi cios de la cubierta C y aprieta firmemente Instala el aro de cubierta decorativo K alineando las ranuras del aro con los tornillos en la cubierta C Rota el aro en sentido contrario a las manecillas del reloj para fijarlo FEST Ensamblaje Como Montar las Aspas del Ventilador Ensamblaje C mo Instalar el Kit de Luces 0 C mo instalar el de luces PRECAUCI N Para disminuir el riesgo de descarga el ctrica desconecta el circuito de energ a del ventilador 1 C mo instalar las pantallas de vidrio y las bombillas PRECAUCI N Aseg rate de que la corriente est cortada antes de montar o retirar las pantallas de vidri
34. y is not used Connect the fan motor white wire MM to the supply white neutral wire MM using a wire connecting nut BB black wire LL to the supply black hot wire LL using a wire connecting nut BB After connecting the wires spread them apart so that the NN and the black wire LL is on the other side Turn the wire connecting nuts upward and carefully push the wiring into the outlet box NN Seat the hanger ball portion of the ball downrod assembly B Connect the fan light supply blue wire KK and the fan motor green JJ and white wires MM are one side of the outlet box 2 2 NN o 11 gt x m KK MM UL MM HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Assembly Hanging the Fan continued 7 Mounting the fan Close to Ceiling mounting WARNING When using the standard ball downrod mounting the tab in the ring at the bottom of the mounting bracket must rest in as an aid to mounting Do not leave the fan assembly unattended until all four canopy screws are engaged and firmly tightened WARNING The locking slots of the ceiling canopy are provided only the groove of the hanger ball Failure to properly seat the tab in the groove could cause damage to the wiring Carefully unhook the fan from the mounting bracket A and Align the