1. Attaching the fan to the electrical box WARNING To reduce the risk of fire electric shock or personal injury mount to an outlet box marked Acceptable for fan support of 35 Ibs 15 9 kg or less and use the screws provided with the outlet box Pass the 120 Volt supply wires through the center hole in the slide on mounting bracket A Install the slide on mounting bracket A on the outlet box by sliding the slide on mounting bracket A over the two screws TT provided with the outlet box If necessary use leveling washers not included between the slide on mounting bracket A and the outlet box The flat side of the slide on mounting bracket A should face toward the outlet box as shown Securely tighten the two mounting screws TT 2 Routing the wires Remove three of the six screws and lock washers QQ every other one securing the motor collar N to the top of the fan motor assembly D Place the rubber gasket FF over the remaining three screws route the wires exiting the top of the fan motor assembly D through the canopy C and canopy ring L make sure the slot openings are on top and then place the canopy C over the collar at the top of the fan motor assembly D Align the mounting holes with the holes in the motor and fasten using the three screws and lock washers QQ removed previously Tighten the mounting
2. pL 3 Assembling the fan could result in the fan becoming loose and possibly WARNING Failure to properly install the locking pin EE falling Loosen but do not remove the setscrews HH on the collar on top of the fan motor assembly D Align the holes at the bottom of the ball downrod assembly B with the holes in the collar on top of the fan motor assembly D Carefully inset the hanger pin DD through the holes in the collar and ball downrod assembly B Be careful not to jam the hanger pin DD against the wiring inside the ball downrod assembly B Insert the locking pin EE through the hole near the end of the hanger pin DD until it snaps into its locked position Re tighten the setscrews HH on the collar on top of the fan motor assembly D 7 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Assembly Close To Ceiling Mount Preparing for mounting Remove the canopy ring L from the canopy C by turning the canopy ring L to the right until it unlocks Remove the slide on mounting bracket A from the canopy C by loosening the four screws SS on the top of the canopy 0 Remove the two non slotted screws SS and loosen the slot ted screws SS Remove the decorative canopy bottom cover M from the canopy C by depressing the three studs Assembly Hanging the Fan
3. continued PACKAGE CONTENTS T E Part Description ouamiy Part Descrition Quantity S Fo Blade 5 i inside canopy Blade bracket 5 B Bawono assemty eee H Glassshade 3 D Fan motorassembly Light bulbs 60 Watt maximum e CN 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 IMPORTANT This product and or components are governed by one or more of the following U S Patents and other patents pending 5 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Installation MOUNTING OPTIONS WARNING To reduce the risk of fire electric shock or personal injury mount to an outlet box marked Acceptable for fan support of 35 Ibs 15 9 kg or less and use the screws provided with the outlet box An outlet box commonly used for the support of lighting fixtures may not be acceptable for fan support and may need to be replaced If in doubt consult a qualified electrician If your ceiling fan does not have an existing UL listed mounting box then install one using the following instructions Disconnect the power by removing the fuses or turning off the circuit breakers Secure the outlet box directly to the building structure Use the appropriate fasteners and materials The outlet box and its bracing must be able to fully support the weight of the moving fan at least 35 Ibs Do not use a plastic outlet box T
4. cliente de Hampton Bay de lunes a viernes entre 8 a m y 6 p m hora est ndar del Este 1 877 527 0313 HAMPTONBAY COM GRACIAS POR TU COMPRA Apreciamos la confianza que has depositado en Hampton Bay al comprar este ventilador de techo Nos esforzamos para continuamente crear productos de calidad dise ados para tu hogar Vis tanos por Internet para ver nuestra l nea completa de productos disponibles para las necesidades de mejoras de tu hogar Gracias por elegir Hampton Bay Tabla de contenido Tabla de contenido iicicicici cncnncinccriccin cr cc 2 Informaci n de Seguridad ooomnccconnccccccooonnnnnnnnnnnnnnnnnnannnnas 2 Garantia ivi 3 Preinstalaci n iii an 3 Instalaci n ici rana 6 Informaci n de seguridad 1 Para disminuir el riesgo de descarga el ctrica aseg rate de cortar la electricidad del cortacircuitos o la caja de fusibles antes de comenzar 2 Todo el cableado debe cumplir con el C digo Nacional de Electricidad ANSI NFPA 70 1999 y con los c digos locales de electricidad La instalaci n el ctrica debe ser hecha por un electricista certificado y calificado 3 La caja el ctrica y estructura de soporte deben montarse de forma segura y tener capacidad para sostener de manera confiable 15 9 kg Usa solamente cajas el ctricas aprobadas por UL marcadas como apropiada para sostener ventiladores de 15 9 kg o menos 4 El ventilador debe ir montado con un m nimo de 2 m de separaci n entre el borde
5. parte inferior del motor del ventilador D y apretando los tornillos del soporte del aspa Los tornillos del motor del ventilador est n fijados en el soporte del aspa G Repite este procedimiento para los cuatro soportes de aspas restantes G 2 Como montar las aspas Monta las aspas del ventilador F al soporte del aspa G alineando los tres orificios tipo ojo de cerradura en el aspa F con los tres postes de la parte superior de los soportes de las aspas G Sost n el aspa F con ambas manos cerca del soporte del aspa G y presiona el aspa F hacia abajo con firmeza Aseg rate de que los orificios tipo ojo de cerradura est n correctamente apoyados sobre los postes del soporte del aspa G Mientras sujetas el aspa F con ambas manos desliza el aspa F hacia el lado opuesto de la carcasa del motor del ventilador D con firmeza hasta que el aspa F se acople al mecanismo de cierre Aseg rate de que el mecanismo de cierre de acero en la parte posterior del soporte del aspa G se eleve y haga tope contra el borde del aspa F lo que indicar una conexi n segura Revisa la parte superior del soporte del aspa G para garantizar que el mecanismo de cierre est asegurado en su lugar Repite este procedimiento para las aspas restantes F HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Ensamblaje C
6. stico CC Despu s de conectar los cables sep ralos de manera que los cables verde Il y blanco LL queden de un lado de la caja el ctrica MM y el cable negro KK del otro lado Gira los conectores pl sticos de cable CC hacia arriba y con cuidado coloca el cableado dentro de la caja el ctrica MM 10 Ensamblaje C mo colgar el ventilador continuaci n del ventilador montaje est ndar ADVERTENCIA Cuando uses el ensamblaje del tubo bajante bola est ndar la pesta a en el aro en la parte inferior del soporte de montaje debe encajar en la ranura de la bola de soporte Si la pesta a no se asienta correctamente en la ranura se puede da ar el cableado Alinea las ranuras de cierre de la cubierta C con los dos tornillos SS del soporte de montaje deslizante A Alza para enganchar las ranuras y gira de izquierda a derecha para asegurar la cubierta C en su sitio Ajusta firmemente los dos tornillos de montaje SS Instala los dos tornillos de montaje SS restantes en los orificios de la cubierta C y aprieta firmemente Instala el aro L de la cubierta decorativa alineando las ranuras del aro con los tornillos en la cubierta C Rota el aro de la cubierta L en sentido contrario a las manecillas del reloj para fijarlo C mo montar el ensamblaje del motor C mo montar el ens
7. the switch housing Allow a 24 hour breaking in period Most noises associated with a new fan disappear during this time If you are using the ceiling fan light kit ensure the screws securing the glassware are tight Check that the light bulbs are also secure Ensure the canopy is a short distance from the ceiling It should not touch the ceiling Ensure your outlet box is secure and rubber isolator pads were used between the mounting plate and outlet box The fan wobbles Check that all blade and blade arm screws are secure Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the Ceiling above the tip of one of the blades Measure from a point on the center of each blade to the point on the ceiling Rotate the fan until the next blade is positioned for measurement Repeat for each blade Any measure ment deviation should be within 1 8 in Run the fan for ten minutes 14 Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HAMPTONBAY COM Retain this manual for future use Art culo n m 993 855 Modelo n m 41350 Modelo n m 52 BVD aprobado por UL GU A DE USO Y MANTENIMIENTO VENTILADOR DE TECHO CAMPBELL DE 1 32 M Preguntas problemas o piezas faltantes Antes de regresar a la tienda llama al Servicio al
8. trasero de las aspas y el piso 5 No muevas el interruptor de reversa mientras las aspas del ventilador est n en movimiento Debes apagar el ventilador y detener las aspas antes de invertir su direcci n 6 No coloques objetos en la trayectoria de las aspas 7 Para evitar lesiones f sicas o da os al ventilador y otros art culos ten cuidado al limpiar o trabajar cerca del ventilador 8 Los diagramas el ctricos son s lo para referencia Los kits de luces no empaquetados con el ventilador deben estar aprobados por UL y marcados como apropiados para ser usados con el modelo de ventilador a instalar Los interruptores deber n estar clasificados por el UL como de uso general Consulta las instrucciones adjuntas a los kits de luces e interruptores para obtener informaci n sobre el ensamblaje adecuado 9 Despu s de concluir las conexiones el ctricas debes voltear los conductores empalmados hacia arriba y meterlos con cuidado en la caja el ctrica Los cables deben estar separados con el cable a tierra y el conductor a tierra del equipo en uno de los lados de la caja el ctrica 10 Todos los tornillos de fijaci n deben ser verificados y ajustados donde sea necesario antes de la instalaci n Ensamblaje cciooiovrsinncacacca ri nn ainsaaa FUNCIONAMIENTO ci c onoronaninsnoncacannonsnsncocadcccncaccnainanicic s Mantenimiento y liMpiezZa ooomnnccccccncnccoonnnnannnnnnnnnnnnannnanas Soluci n de problemMaS s
9. 15 9 kg or less The fan must be mounted with a minimum of 7 ft 2 m clearance from the trailing edge of the blades to the floor Do not operate the reversing switch while the fan blades are in motion You must turn the fan off and stop the blades before you reverse the blade direction Do not place objects in the path of the blades To avoid personal injury or damage to the fan and other items use caution when working around or cleaning the fan Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL listed and marked suitable for use with the model fan you are installing Switches must be UL General Use Switches Refer to the instructions packaged with the light kits and switches for proper assembly After making electrical connections spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box All setscrews must be checked and retightened where necessary before installation ASSemMBIy sisirain na sidanau nasara Naan aa aad nadadaan baara saasaa 7 AAPP A 12 Care and Cleaning coococcccnnnnnnannnanaccnoncno none 14 TroublesShootiNg lt lt lt ociooisisiconionsosnrinananasnninendoaninn nn sniscinas 14 WARNING To reduce the risk of personal injury do not bend the blade brackets also referred to as flanges dur
10. 1D fabricado por Chungear Industrial Co LTD o FAN38R T190 fabricado por Chia Wei Electric Co LTD Garant a El proveedor garantiza de por vida a partir de la fecha en que el comprador original lo adquiere que el motor del ventilador no presenta defectos de fabricaci n ni de materiales al momento en que es enviado desde la f brica El proveedor tambi n garantiza por un per odo de un a o a partir de la fecha de compra por el comprador original que todas las dem s piezas del ventilador sin incluir ning n aspa de vidrio o acr lico no presentar n ning n defecto de fabricaci n o de material en el momento de su salida de la f brica Acordamos reparar todos los defectos del tipo antes mencionado sin cargo alguno o a nuestra discreci n reemplazar el producto por un modelo de calidad comparable o superior si el producto se devuelve Para obtener servicio de garant a usted debe presentar una copia del recibo como comprobante de compra Todos los costos de retiro y reinstalaci n del producto son su responsabilidad Los da os a cualquiera de las piezas como resultado de accidentes uso inadecuado instalaci n inadecuada o debidos a la instalaci n de cualquier accesorio no est n cubiertos bajo esta garant a Debido a que las condiciones clim ticas pueden variar esta garant a no cubre ning n cambio del acabado en bronce incluyendo xido perforaci n corrosi n manchas o descascar amiento Los acabados en bronce de este tip
11. E12 eliminar la opci n de regulaci n de intensidad y puede causar parpadeos 12 Funcionamiento C MO USAR EL VENTILADOR Tu ventilador est equipado con un control remoto que controla la velocidad y las luces de tu nuevo ventilador de techo m Las configuraciones de velocidad para clima c lido o fr o dependen de factores como el tama o de la habitaci n la altura del techo la cantidad de ventiladores y dem s Este ventilador se env a desde la f brica con el interruptor de reversa posicionado para hacer circular el aire hacia abajo Si deseas dirigir la i A corriente de aire en la direcci n contraria apaga el ventilador y espera que las aspas se detengan luego desliza el interruptor de reversa ubicado en la caja del interruptor hacia la direcci n opuesta y vuelve a prender el ventilador Las aspas del ventilador girar n en sentido contrario y revertir n la direcci n de la corriente de aire NOTA Espera a que se detenga el ventilador antes de invertir la direcci n de giro de las aspas refrescante Esto te permite fijartu aire acondicionado en una configuraci n Clima c lido Hacia adelante Un flujo de aire hacia abajo crea un efecto di m s alta sin afectar tu comodidad Clima fr o Reversa Un flujo de aire hacia arriba mueve el aire c lido lejos del techo Esto te permite fijar tu unidad de calefac
12. Item 993 855 Model 41350 UL Model 52 BVD USE AND CARE GUIDE CAMPBELL 52 INCH CEILING FAN Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HAMPTONBAY COM THANK YOU We appreciate the trust and confidence you have placed in Hampton Bay through the purchase of this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay Table of Contents Table Of Contents cocmmnncccnnnnnanccnnnnnnannrnnnnn rre 2 Safety Information i222 c0iecccccescceccceceaseesseccessccececescaacasecnseencess 2 Warranty APA d A 3 Pre InstallatioN sissies iosiaciorcosaciccarannnnicncccnrnaca near nrnio canaria cra 3 Installations 6 Safety Information To reduce the risk of electric shock ensure the electricity has been turned off at the circuit breaker or fuse box before you begin All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 1999 and local electrical codes Electrical installation should be performed by a qualified licensed electrician The outlet box and support structure must be securely mounted and capable of reliably supporting 35 Ibs 15 9 kg Use only UL Listed outlet boxes marked Acceptable for Fan Support of 35 Ibs
13. ador Debido al movimiento natural del ventilador algunas conexiones pueden aflojarse Revisa las conexiones de soporte soportes y accesorios de aspas dos veces al a o Verifica que est n seguros No es necesario desmontar el ventilador del techo Limpia tu ventilador con frecuencia para que luzca como nuevo con el paso de los a os No uses agua al limpiar esto puede da ar el motor o la madera o causar descargas el ctricas Usa solamente un cepillo suave o un pa o sin pelusas para evitar ara ar el acabado El revestimiento est sellado con laca para minimizar la decoloraci n u opacidad Puedes aplicar a la madera una fina capa de pulimento para muebles para una mayor protecci n y belleza Cubre los ara azos peque os con una leve aplicaci n de lustrador para calzado No necesitas lubricar tu ventilador El motor tiene cojinetes de bola sellados permanentemente lubricados Soluci n de problemas Problema Soluci n o O El ventilador no enciende El ventilador hace ruido El ventilador oscila Verifica los fusibles o disyuntores principales y secundarios Aseg rate de que el interruptor de pared est en posici n de encendido ON si corresponde Verifica las conexiones de cables en l nea al ventilador y conexiones de cables del interruptor en la caja de interruptores Revisa la bate
14. amblaje del motor del ventilador montaje cerca del techo ayuda durante el montaje No dejes sin supervisi n el ensamblaje del ventilador hasta que los cuatro tornillos de la cubierta est n fijos y firmemente ajustados Con cuidado desengancha el ventilador del soporte de montaje A y alinea las ranuras de cierre de la cubierta C con los dos tornillos SS en el soporte de montaje deslizante A Alza para enganchar las ranuras y gira de izquierda a derecha para asegurar la cubierta C en su sitio Ajusta con firmeza los dos tornillos de montaje SS Instala los dos tornillos de montaje SS restantes en los orificios de la cubierta C y aprieta firmemente Instala el aro L de la cubierta decorativa alineando las ranuras del aro con los tornillos en la cubierta C Rota el aro de la cubierta L en sentido contrario a las manecillas del reloj para fijarlo Ta gt ADVERTENCIA Las ranuras de cierre de la cubierta s lo sirven de CEN L ES NN NN cc Ensamblaje C mo montar las aspas del ventilador C mo montar los soportes de las aspas al motor NOTA Tu ventilador cuenta con avances novedosos para facilitar y acelerar la instalaci n de las aspas NOTA Las aspas de tu ventilador son reversibles Elige el acabado del aspa que mejor resalte tu decoraci n Ajusta el soporte del aspa G al motor del ventilador D insertando el poste de alineaci n dentro de la ranura de la
15. auge house wiring or more than one house wire to connect to the fan wiring consult an electrician for the proper size wire connectors to use A___ MM CAUTION If the supply wires are a different color have this unit installed by a licensed electrician a IMPORTANT Use the plastic wire connectors CC supplied with O your fan Secure the connectors with electrical tape and ensure there are no loose strands or connections pot m NOTE The fan comes with 54 inch lead wires for use with an 5 lt 4 A extended ball downrod assembly If using the 4 5 inch ball pa downrod assembly B provided you can cut the lead wires to your desired length no shorter than 12 inches Connect the ground conductor of the 120 Volt supply this may be a bare wire or a wire with green colored insulation to the green ground lead Il of the fan using a plastic wire connector CC Z Connect the fan motor white wire LL to the receiver K white wire LL using a plastic wire connector CC Connect the fan motor black wire KK to the receiver K black lt 7 wire KK using a plastic wire connector CC Connect the fan motor blue wire JJ to the receiver K blue wire JJ using a plastic wire connector CC Connect the receiver K red wire 00 to the supply black hot wire KK using a plastic wire connector CC Connect the receiver K white wire LL to the supply white a 6 i wi
16. ca los cables de suministro en el lado izquierdo del j soporte de montaje deslizante A y coloca los cables del Quita la cubierta de la bateria del control remoto J presionando ventilador en el lado derecho con firmeza en la flecha y deslizando la cubierta hasta soltarla Inserta parcialmente el receptor K con el lado plano hacia Desliza los interruptores de c digo a tu elecci n hacia arriba o arriba en el soporte de montaje deslizante A hasta que un hacia abajo Las configuraciones de f brica son hacia arriba extremo descanse sobre el ensamblaje del tubo bajante bola B Desliza los interruptores del receptor K hacia la misma posici n que elegiste para el control remoto J Coloca de nuevo la cubierta en el control remoto J 9 HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Ensamblaje C mo colgar el ventilador continuaci n 5 C mo hacer las conexiones el ctricas ADVERTENCIA Cada conector de cables provisto con este ventilador est dise ado para aceptar cables dom sticos de un calibre m ximo de 12 y dos cables del ventilador Si tienes un cableado superior a calibre 12 o m s de un cable para conectar al ventilador consulta a un electricista para conocer el tama o adecuado de los conectores a usar A___ MM PRECAUCI N Si los cables de suministro son de color diferente g un electricista certificado deber instalar esta unidad IMPORTANTE U
17. ci n en una configuraci n m s baja sin afectar tu comodidad USO DEL CONTROL REMOTO NOTA Este control remoto est equipado con una combinaci n de 16 c digos Para evitar posibles interferencias desde o hacia otras unidades de control remoto como los abrepuertas de garajes alarmas de autos o sistemas de seguridad cambia el c digo de combinaci n pero aseg rate de que el c digo del control remoto y del receptor del ventilador sean iguales Instala una bater a de 12 V incluida en el compartimiento del control remoto J Oprime el bot n deseado del control remoto J para usar el ventilador Bot n 3 Oprime para establecer la velocidad del ventilador en alta Bot n 2 Oprime para establecer la velocidad del ventilador en media Bot n 1 Oprime para establecer la velocidad del ventilador en baja Bot n de encendido UU Presi nalo para encender o apagar el ventilador Bot n para luces VV Oprime y suelta el bot n inmediatamente para encender o apagar la luz Mant n presionado para atenuar o aclarar la luz en la intensidad deseada y luego su ltalo la funci n de regulaci n de intensidad es solo para bombillas de Tungsteno UU VV 13 HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Mantenimiento y limpieza A ADVERTENCIA Aseg rate de que la corriente est apagada antes de limpiar el ventil
18. e desde un punto en el centro de cada aspa a un punto en el techo Gira el ventilador hasta que la pr xima aspa quede posicionada para medir Repite para cada aspa Las desviaciones de la medici n deben estar dentro de 0 31 cm Enciende el ventilador durante diez minutos 14 Preguntas problemas o piezas faltantes Antes de regresar a la tienda llama al Servicio al cliente de Hampton Bay de lunes a viernes entre 8 a m y 6 p m hora est ndar del Este 1 877 527 0313 HAMPTONBAY COM Conserva este manual para consultarlo en el futuro
19. e la cubierta de techo C Ensamblaje C mo colgar el ventilador continuaci n 3 C mo instalar el receptor C mo configurar el c digo del control remoto y el receptor ADVERTENCIA Para reducir el riesgo de incendio o de descarga el ctrica recuerda desconectar la electricidad El cableado el ctrico debe cumplir todos los requisitos de c digos el ctricos nacionales y locales Las fuentes de energ a y el ventilador deben ser de 110 120 voltios y 60 Hz No utilices este producto con ning n control variable de pared Conectar el cableado de NOTA Las frecuencias del receptor y control remoto han sido preconfiguradas en la f brica Antes de instalar el receptor aseg rate de que los interruptores en el transmisor y del control remoto est n configurados en la misma frecuencia Los interruptores en el transmisor del control remoto est n i ERE ubicados dentro del compartimento de la bater a manera incorrecta da ar este receptor PRECAUCI N No instalar en lugares h medos ni sumergir NOTA La bater a se debilitar con el tiempo y deber ser E OS E reemplazada antes de que se produzca alguna fuga ya en agua s lo para uso en interiores No hales ni cortes los lo da ar el control to D ha las batert cables No dejes caer ni golpees la unidad que esto da ar el control remoto Desecha las bater as adecuadamente y mantenlas fuera del alcance de los ni os O Ubi
20. e y caiga Afloja sin quitar los tornillos HH del collar n ubicados en la parte superior del ensamblaje del motor del ventilador D Alinea los orificios en la parte inferior del ensamblaje del tubo bajante bola B con los orificios en el collar n de la parte superior del ensamblaje del motor del ventilador D Inserta con cuidado el pasador de soporte DD a trav s de los orificios del collar n y del ensamblaje del tubo bajante bola B Ten cuidado de no forzar el pasador de soporte DD contra el cableado dentro del ensamblaje del tubo bajante bola B Inserta el pasador de cierre EE en el orificio cercano al extremo del pasador de sujeci n DD hasta que quede encajado en su posici n Vuelve a apretar los tornillos HH del collar n ubicados en la parte superior del ensamblaje del motor del ventilador D 2 Montaje est ndar en techo Disposici n de los cables Aseg rate de que las ranuras est n en la parte superior y pasa los cables existentes sobre la parte superior del ensamblaje del motor del ventilador D a trav s de la cubierta C y el aro de la cubierta L y luego a trav s del ensamblaje del tubo bajante bola B HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Ensamblaje Preparaci n para el montaje Retira el aro de la cubierta L de la cubierta C girando el aro L hacia la derecha hasta destraba
21. er ventiladores de 15 9 kg o menos y usa s lo los tornillos incluidos con la caja el ctrica Pasa los cables de suministro de 120 Voltios a trav s del orificio central en el soporte de montaje deslizante A Instala el soporte de montaje deslizante A sobre la caja el ctrica deslizando el soporte de montaje A sobre los dos tornillos TT suministrados con la caja el ctrica Si es necesario usa arandelas niveladoras no incluidas entre el soporte de montaje deslizante A y la caja el ctrica El lado plano del soporte de montaje deslizante A est hacia la caja el ctrica como se muestra Ajusta firmemente los dos tornillos de montaje TT 2 Como colgar el ventilador ADVERTENCIA El gancho debe usarse para sostener el ventilador solamente mientras se hacen las conexiones el ctricas Si no se cuelga como se muestra puede romperse el gancho y el ventilador se caera El gancho debe pasar de adentro hacia fuera de la cubierta C Con cuidado alza el ensamblaje del motor del ventilador D hasta el soporte de montaje deslizante A Coloca la bola de soporte del ensamblaje del tubo bajante bola B en el soporte de montaje deslizante A Aseg rate de que la pesta a sobre el soporte de montaje deslizante A encaje bien dentro de la ranura de la bola de soporte Si usas el montaje cerca del techo cuelga el ventilador del gancho suministrado usando uno de los orificios en el borde exterior d
22. f this switch see Operating Your Fan and Remote Control on page 12 Reset the lights by turning off the lights replacing the bulbs with the correct wattage bulbs and turn the lights back on NOTE If you need an extra switch cup or cover for the CAUTION Make sure the power is off before attaching or non light option please call 1 800 283 6513 M F 9 00am removing the glass shades to 4 30pm EST NOTE Using a E12 CFL type bulb will eliminate the dimming Remove the three screws RR on the switch cup cover of the A option and may cause flickering light kit fitter assembly E Connect the wires from the light kit fitter assembly E to the Insert the glass shade H into the light kit fitter assembly E glass holder by carefully squeezing the steel tensioners TT on the light kit fitter assembly E socket together Gently slide the glass shade H over the steel tensioners TT Make sure the glass shade H is fully inserted into wires from the switch cup of the fan motor assembly D by connecting the molded adaptor plugs together blue to black white to white Carefully tuck all wires and splices into the switch cup oO Align the three holes in the switch cup cover of the light kit fitter assembly E with the three holes in the switch cup me socks tor secre Repeat tile procadune tor Ihe of the fan motor assembly D Make sure the notch in the romaning gaes shanas A switch cup cove
23. he illustrations below show three different ways to mount the outlet box de Outlet Box Provide Strong Support Recessed Ceiling Outlet Mounting Plate Box NOTE You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped Ceiling The maximum angle allowable is 20 away from horizontal Hanger Bar Outlet Box If the canopy C touches the ball downrod assembly B then remove the decorative canopy bottom cover and turn the canopy C 180 before attaching the canopy C to the mounting plate To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown above available at any Home Depot store Assembly Standard Ceiling Mount 1 Preparing for standard mounting 2 Routing the wires Make sure the slot openings are on top and route the wires exiting the top of the fan motor assembly D through the canopy C and the canopy ring L and then through the ball downrod assembly B Remove the canopy ring L from the canopy C by turning the canopy ring L to the right until it unlocks Remove the slide on mounting bracket A from the canopy C by loosening the four screws SS on the top of the canopy C Remove the two non slotted screws SS and loosen the slotted screws SS This will enable you to remove the slide on mounting bracket A
24. iling Clean your fan periodically to help maintain its new appearance over the years Do not use water when cleaning as this could damage the motor or the wood or possibly cause an electrical shock Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing You can apply a light coat of furniture polish to the wood for additional protection and enhanced beauty Cover small scratches with a light application of shoe polish You do not need to oil your fan The motor has permanently lubricated sealed ball bearings Troubleshooting Problem Solution The fan will not start Check the main and branch circuit fuses or breakers Check to make sure the wall switch is in the on position if applicable Check the line wire connections to the fan and switch wire connections in the switch housing Check the battery in the remote control Ensure you are in the normal range of 10 20 feet Ensure the dip switch settings are the same on the remote control and receiver Remember to turn off the power supply before checking the dip switches settings The fan is noisy Ensure all motor housing screws are snug Ensure the screws that attach the fan blade bracket to the motor hub are tight Ensure the wire nut connections are not rattling against each other or the interior wall of
25. ing assembly or after installation Do not insert objects in the path of the blades WARNING Remove the rubber motor stops on DA the bottom of the fan before installing the blades or testing the motor WARNING To reduce the risk of fire or electric AN shock do not use this fan with any solid state speed control device WARNING To reduce the risk of fire electric shock or personal injury mount to outlet box marked Acceptable for fan support of 35 Ibs 15 9 kg or less and use the screws provided with the outlet box WARNING To avoid possible electrical shock turn the electricity off at the main fuse box before wiring If you feel you do not have enough electrical wiring knowledge or experience contact a licensed electrician WARNING Electrical diagrams are for reference only Optional use of any light kit shall be UL listed and marked suitable for use with this fan WARNING To reduce the risk of fire or electric shock this fan should only be used with fan speed control part no MR101D manufactured by Chungear Industrial Co LTD or control part no FAN38R T190 manufactured by Chia Wei Electric Co LTD Warranty The supplier warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a life time after the date of purchase by the original purchaser The supplier also warrants that all other fan parts excluding any glass or acrylic blades t
26. l cliente Comun quese con el equipo de servicio al cliente por el tel fono 1 877 527 0313 o visite www HamptonBay com Preinstalaci n Se Tama o Velocidad Voltios Amperios PCM FR Pese p SS neto bruto c bicos PIE 18 3 Ibs 20 9 Ibs vem rae ype fo fe we es esky NOTA Estas medidas son aproximadas No incluyen ni el amperaje ni el vataje consumido por el kit de luces HERRAMIENTAS NECESARIAS amp Cp Destornillador 6 Destornillador Llave Cinta de l mida iN es Cortacables Phillips plano ajustable electricista Escalera 3 HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Preinstalaci n continuaci n HERRAJES INCLUIDOS NOTA No se muestra el tama o real de los herrajes B cC DD FE Pieza Descripci n Cantidad Pieza Descripci n Cantidad ES Tornillo adicional para soporte de DD Pasador de soporte aspas EE Pasadordecierre fo 414 Arandela de seguridad adicional FR Junta de goma Conector de cables pl stico Preinstalaci n continuaci n CONTENIDO DEL PAQUETE LJ Cantidad Soporte deslizante de montaje dentro de la cubierta B Ensamblaje de tubo bajante bola D Ensamblaje del motor del ventilador Ensamblaje del soporte del kit de luces protegidos por una o m s de las siguientes Patentes de los EE UU 5 947 436 5 988 580 6 010 110 6 046 416 O IMPORTANTE Este produc
27. la caja el ctrica el ctrica Soporte fuerte Placa de montaje en techo Caja el ctrica empotrada mantener la altura m nima adecuada de las aspas al instalar el ventilador en un techo inclinado El ngulo m ximo permitido es de 20 de la posici n horizontal gt NOTA Tal vez necesites un tubo bajante m s largo para Barra para colgar Caja el ctrica Si la cubierta C toca el ensamblaje del tubo bajante bola B retira la tapa inferior decorativa de la cubierta y gira la cubierta C 180 antes de fijarla a la placa de montaje Para colgar el ventilador donde ya haya una l mpara pero ninguna viga de techo tal vez necesites una barra colgante como se mostr anteriormente disponible en cualquier tienda de The Home Depot Ensamblaje Preparacion para montaje estandar Retira el aro de la cubierta L de la cubierta C girando el aro de la cubierta L a la derecha hasta destrabarlo Retira el soporte de montaje deslizante A de la cubierta C aflojando los cuatro tornillos SS en la parte superior de la cubierta C Quita los dos tornillos sin ranura SS y afloja los tornillos ranurados SS Esto te permitira retirar el soporte de montaje deslizante A pL 3 Como ensamblar el ventilador ADVERTENCIA Si no instalas correctamente el pasador de cierre EE es posible que el ventilador se afloj
28. lots of the canopy are provided only as an aid to mounting Do not leave the fan assembly unattended until all four canopy screws are engaged and firmly tightened Carefully unhook the fan from the slide on mounting bracket A and align the locking slots of the canopy C with the two screws SS in the slide on mounting bracket A Push up to engage the slots and turn clockwise to lock the canopy C in place Immediately tighten the two mounting screws SS firmly Install the remaining two mounting screws SS into the holes in the canopy C and tighten firmly Install the decorative canopy ring L by aligning the ring s slots with the screws in the canopy C Rotate the canopy ring L counterclockwise to lock it in place SS Assembly Attaching the Fan Blades Attaching the blade brackets to the motor NOTE Your fan features revolutionary advancements for quick and easy blade installation NOTE Your fan blades are reversible Select the blade side finish which best accentuates your decor Fasten the blade bracket G to the fan motor D by insert ing the alignment post into the slot on the bottom of the fan motor D and tightening the fan motor screws The fan motor screws are pre attached to the blade bracket G Repeat this procedure for the remaining four blade brackets G 2 Attaching the blades Mount the fan blade F to the blade bracke
29. lower setting without affecting your comfort USING THE REMOTE CONTROL NOTE This remote is equipped with a 16 code combination To prevent possible interference from or to other remote units such as garage door openers car alarms or security systems change the combination code but be sure that the code on both the remote control and receiver in the fan are the same Install the 12 Volt battery included into the battery compartment of the remote control J Press the desired button on the remote control J to operate the fan 3 button Press to set the fan speed to high 2 button Press to set the fan speed to medium 1 button Press to set the fan speed to low Power button UU Press to turn the fan off or on Light button VV Press and release immediately to turn the light on or off Press and hold to dim or brighten the bulbs to the desired level and then release the dimmer function is for Tungsten bulbs only 13 UU VV HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Care and Cleaning your fan A WARNING Make sure the power is off before cleaning Because of the fan s natural movement some connections may become loose Check the support connections brackets and blade attachments twice a year Make sure they are secure It is not necessary to remove the fan from the ce
30. mo instalar las l mparas C mo instalar el ensamblaje del soporte del kit de luces PRECAUCI N Para disminuir el riesgo de descarga el ctrica desconecta el circuito de energ a del ventilador antes de instalar la l mpara NOTA Marca la posici n del interruptor deslizante del ventilador Este es el interruptor utilizado para cambiar la direcci n de la rotaci n del ventilador Para obtener m s informaci n sobre el funcionamiento de este interruptor consulta C mo usar el ventilador y el Control remoto en la p gina 12 NOTA Si necesitas una caja del interruptor adicional o cubierta para la opci n sin luces llama al 1 800 283 6513 L V 9 00 a m a 4 30 p m hora est ndar del Este Quita los tres tornillos RR en la cubierta de la caja del interruptor del ensamblaje del soporte del kit de luces E Conecta los cables del ensamblaje del soporte del kit de luces E a los cables de la caja del interruptor del ensamblaje del motor del ventilador D usando los enchufes con adaptadores moldeados azul con negro blanco con blanco Coloca con cuidado todos los cables y empalmes dentro de la caja del interruptor Alinea los tres orificios de la cubierta de la caja del interruptor del ensamblaje del soporte del kit de luces E con los tres orificios en la caja del interruptor del ensamblaje del motor del ventilador D Aseg rate de que la muesca en la cubierta de la caja del interruptor del soporte del kit de luces E pe
31. o be free from defects in workmanship and material at the time of shipment from the factory for a period of one year after the date of purchase by the original purchaser We agree to correct such defects without charge or at our option replace with a comparable or superior model if the product is returned To obtain warranty service you must present a copy of the receipt as proof of purchase All costs of removing and reinstall ing the product are your responsibility Damage to any part such as by accident misuse improper installation or by affixing any accessories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not allow a limitation on how long an implied war ranty lasts so the above limitation ma
32. o tienen una vida til m s prolongada cuando se protegen de las condiciones clim ticas cambiantes Es normal cierta oscilaci n y no debe ser considerado como un defecto Cualquier servicio t cnico conducido por personas no autorizadas anular la garant a No hay ninguna otra garant a expresa Mediante la presente Hampton Bay se exime de cualquier garant a incluyendo pero sin limitarse a aquellas de comercializaci n e idoneidad para un fin particular de acuerdo a lo contemplado por la ley La duraci n de cualquier garant a impl cita que no se pueda eximir est limitada al per odo de tiempo especificado en la garant a expl cita Algunos estados no permiten una limitaci n en la duraci n de la garant a por consiguiente la limitaci n anterior puede no aplicarse a su caso El minorista no ser responsable por da os directos indirectos o especiales que resulten o deriven del uso o rendimiento del producto excepto en casos en que lo estipule la ley Algunos estados no permiten la exclusi n o limitaci n de da os directos o indirectos por lo que la limitaci n o exclusi n anterior podr a no aplicarse a su caso Esta garant a le otorga derechos legales espec ficos pero es posible que tambi n tenga otros derechos que var an de un estado a otro Esta garant a sustituye todas las garant as anteriores Los costos de env o de cualquier devoluci n de productos hecha como parte de una reclamaci n de garant a deben ser pagados por e
33. on the fan wires to the right side Partially insert the receiver K flat side up into the slide on mounting bracket A until one end rests on the ball downrod assembly B Setting the code on the remote control and receiver NOTE The frequencies on your receiver and remote control have been preset at the factory Before installing the receiver make sure the dip switches on the receiver and remote control are set to the same frequency The dip switches on the remote control are located inside the battery compartment NOTE The battery will weaken with age and should be replaced before leaking takes place as this will damage the remote control Dispose of used batteries properly and keep batteries out of the reach of children Remove the remote control J battery cover by pressing firmly on the arrow and sliding the cover off Slide the code switches to your choice of either up or down The factory setting is up Slide the code switches on the receiver K to the same posi tion as set on the remote control J Replace the battery cover on the remote control J HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Assembly Hanging the Fan continued 5 Making the electrical connections WARNING Each wire connector supplied with this fan is designed to accept up to one 12 gauge house wire and two wires from the fan If you have larger than 12 g
34. r a del control remoto Aseg rate de estar en el rango normal de 3 a 6 1 m Aseg rate de que las configuraciones del interruptor en l nea sean las mismas para el control remoto y el receptor Recuerda desconectar la electricidad antes de verificar las configuraciones de los interruptores en l nea Aseg rate de que los tornillos de la carcasa del motor est n ajustados Aseg rate de que los tornillos que unen el soporte del aspa al cuerpo del motor est n bien ajustados Aseg rate de que las conexiones de tuerca de cable no choquen unas con otras o con la pared interior de la caja del interruptor Permite un per odo de 24 horas de adaptaci n La mayor a de los ruidos asociados con un nuevo ventilador desaparecen en ese per odo Si usas el kit de luces de ventilador de techo aseg rate de que los tornillos que sujetan el vidrio est n bien colocados Verifica que las bombillas est n bien aseguradas Aseg rate de que la cubierta est a una corta distancia del techo No debe tocar el techo Aseg rate de que tu caja el ctrica est bien segura y las almohadillas aislantes de goma se hayan instalado entre la placa de montaje y la caja el ctrica Verifica que todas las aspas y tornillos de los brazos de aspas est n seguros La mayor a de los problemas de oscilaci n del ventilador se deben a que las aspas no est n a un mismo nivel Verifica este nivel seleccionando un punto en el techo sobre la punta de una de las aspas Mid
35. r of the light kit fitter assembly E clears the With the power off install the light bulbs I into the light reversing switch in the switch cup of the fan motor assembly bulb sockets D Position the light kit fitter assembly E and re install the three screws RR that were removed in first step to secure the light kit fitter assembly E 12 Operation OPERATING YOUR FAN Your fan is equipped with a remote control to operate the fan speed and lights of your new ceiling fan The speed setting for warm or cool weather depends on factors such as the room size ceiling height number of fans and so on The fan is shipped from the factory with the reversing switch positioned to circulate air downward If airflow is desired in the opposite direction turn your fan off and wait for the blades to stop turning then slide the reversing switch located in switch cup to the opposite position and turn the fan on again The fan blades will turn in the opposite direction and reverse airfow NOTE Wait for the fan to stop before reversing the direction of the blade rotation Warm weather Forward A downward airflow creates a cooling effect This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Reverse An upward airflow moves warm air off of the ceiling This allows you to set your heating unit on a
36. re neutral LL wire using a plastic wire connector CC After connecting the wires spread them apart so that the green Il and white LL wires are on one side of the outlet box MM and the black wire KK is on the other side Turn the plastic wire connectors CC upward and carefully push the wiring into the outlet box MM J LL 10 Mounting the fan motor assembly standard mount WARNING When using the standard ball downrod mounting the A tab in the ring at the bottom of the mounting bracket must rest in the groove of the hanger ball Failure to properly seat the tab in the groove could cause damage to the wiring Align the locking slots of the canopy C with the two screws SS in the slide on mounting bracket A Push up to engage the slots and turn clockwise to lock the canopy C in place Firmly tighten the two mounting screws SS Install the remaining two mounting screws SS into the holes in the canopy C and tighten firmly Install the decorative canopy ring L by aligning the ring s slots with the screws in the canopy C Rotate the canopy ring L counterclockwise to lock it in place Assembly Hanging the Fan continued Mounting the fan motor assembly close to ceiling mount WARNING The locking s
37. rlo Retira el soporte de montaje deslizante A de la cubierta C aflojando los cuatro tornillos SS en la parte superior de la misma Quita los dos tornillos sin ranura SS y afloja los tornillos ranurados SS Retira la cubierta inferior decorativa M de la cubierta C oprimiendo los tres pernos ple Montaje cerca del techo 2 Disposicion de los cables Retira tres de los seis tornillos y arandelas de seguridad QQ alternados que sujetan el collarin del motor N a la parte superior del ensamblaje del motor del ventilador D Coloca la junta de goma FF sobre los tres tornillos restantes pasa los cables que salen de la parte superior del ensamblaje del motor del ventilador D a trav s de la cubierta C y el aro de la cubierta L aseg rate de que las aberturas de las ranuras est n hacia arriba y luego coloca la cubierta C sobre el collar n de la parte superior del ensamblaje del motor D Alinea los orificios de montaje con los orificios del motor y asegura con los tres tornillos y arandelas de seguridad QQ retirados anteriormente Aseg rate de ajustar bien los tornillos de montaje Ensamblaje C mo colgar el ventilador C mo fijar el ventilador a la caja el ctrica ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica u otras lesiones instala s lo en una caja el ctrica clasificada como apropiada para sosten
38. rmita que el interruptor de reversa en la caja del interruptor del ensamblaje del motor del ventilador D se mueva libremente Coloca el ensamblaje del soporte del kit de luces E y vuelve a colocar los tres tornillos RR que fueron retirados en el primer paso para asegurar el ensamblaje del soporte del kit de luces C mo instalar las pantallas de vidrio y las bombillas A ADVERTENCIA Espera que la pantalla de vidrio se enfr e A completamente antes de retirarla ADVERTENCIA Colocar bombillas de vataje incorrecto en el kit de luces har que las luces se apaguen hasta que se instale las bombillas adecuadas Apaga el kit de luces reemplaza las bombillas con otras de vataje correcto y vuelve a encenderlo PRECAUCI N Aseg rate de que la corriente est cortada antes de montar o retirar las pantallas de vidrio A Inserta la pantalla de vidrio H en el soporte de vidrio del ensamblaje del soporte del kit de luces E apretando con cuidado los tensores de acero TT sobre el portabombilla del ensamblaje del soporte del kit de luces E Con cuidado desliza la pantalla de vidrio H sobre los tensores de acero TT Aseg rate de que la pantalla de vidrio H est totalmente insertada en el portabombillas para una colocaci n segura Repite este procedimiento para las pantallas de vidrio restantes H Con la electricidad apagada instala las bombillas I en los portabombillas NOTA El uso de una bombilla CFL
39. sa los conectores de pl stico para cable CC incluidos con tu ventilador Amarra los conectores con cinta el ctrica y aseg rate de que no haya cables o conexiones sueltas gt lt 4 NOTA El ventilador viene con 54 cables pulgadas para su uso con a x as una amplia tubo bajante bola de montaje Si se utiliza el tubo bajante bola de 4 5 pulgadas de montaje B previstos usted puede cortar los cables a la longitud deseada no menos de 12 pulgadas B Conecta el conductor a tierra del cable de 120 Voltios puede ser un cable desnudo o un cable con aislante verde al cable terminal a tierra verde II del ventilador usando un conector _ de cables plastico CC Conecta el cable blanco del motor del ventilador LL al cable blanco LL del receptor K usando un conector de cables plastico CC X 7 Conecta el cable negro del motor del ventilador KK al cable negro KK del receptor K usando un conector de cables plastico CC Conecta el cable azul del motor del ventilador JJ al cable azul JJ del receptor K usando un conector de cables J LL pl stico CC PS Conecta el cable rojo 00 del receptor K al cable negro de KK LL suministro de energ a positivo KK usando un conector de cables pl stico CC Conecta el cable blanco LL del receptor K al cable blanco de suministro neutro LL usando un conector de cables pl
40. screws securely 2 Hanging the fan WARNING The hook is only to balance the fan while making the electrical connections Failure to hang as shown may result in the hook breaking causing the fan to fall The hook must pass from the inside to the outside of the canopy C Carefully lift the fan motor assembly D up to the slide on mounting bracket A Seat the hanger ball portion of the ball downrod assembly B in the slide on mounting bracket A socket Ensure that the tab on the slide on mounting bracket A socket is properly seated in the groove in the hanger ball If using close to ceil ing mounting hang the fan on the hook provided by utilizing one of the holes at the outer rim of the ceiling canopy C Assembly Hanging the Fan continued 3 Installing the receiver WARNING To reduce the risk of fire or electric shock remember to disconnect the power The electrical wiring must meet all local and national electrical code requirements The electrical source and fan must be 110 120 volt 60Hz Do not use this product in conjunction with any variable wall control Incorrect wire connection can damage this receiver CAUTION Do not install in a damp location or immerse in water for indoor use only Do not pull on the leads or cut the leads shorter Do not drop or bump the unit Position the supply wires to the left side of the slide on mounting bracket A positi
41. ssssssssssnesnnnnnnnnnnnnnnnnnnnnnnnnnnnnn ADVERTENCIA Para reducir el riesgo de lesiones no dobles los soportes de las aspas tambi n llamados bridas durante el ensamblaje o despu s de la instalaci n No coloques objetos en la trayectoria de las aspas ADVERTENCIA Retira los topes de goma del motor en la parte inferior del ventilador antes de instalar las aspas o probar el motor ADVERTENCIA Para disminuir el riesgo de incendio o descarga el ctrica no utilices este ventilador con ning n dispositivo de control de velocidad de estado s lido ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica u otras lesiones instala s lo en una caja el ctrica clasificada como apropiada para sostener ventiladores de 15 9 kg o menos y usa s lo los tornillos incluidos con la caja el ctrica ADVERTENCIA Para evitar una posible descarga el ctrica corta la energ a el ctrica en la caja principal de fusibles antes de instalar el cableado Si crees que no tienes suficiente experiencia o conocimientos sobre cableado el ctrico contrata a un electricista con licencia ADVERTENCIA Los diagramas el ctricos son s lo para referencia Cualquier juego de luces opcional debe estar aprobado por UL y marcado como adecuado para ser usado con este ventilador ADVERTENCIA Para disminuir el riesgo de incendio o descarga el ctrica este ventilador s lo debe ser usado con un control de velocidad con el n m de pieza MR10
42. t G by aligning the three key slot holes in the blade F with the three posts on the top of the blade bracket G Hold the blade F with both hands close to the blade bracket G and press the blade F down firmly Ensure the key slot holes are properly seated on the blade bracket G posts While still holding the blade F down with both hands firmly slide the blade F away from the fan motor D housing until the blade F engages in the locking mechanism Make sure the steel locking mechanism at the rear of the blade bracket G springs upward and butts against the edge of the blade F indicating a secure connection Visually inspect the top of the blade bracket G to ensure the locking mechanism is securely in place Repeat this procedure for the remaining blades F HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Assembly Attaching the lights 1 Attaching the light kit fitter assembly 2 pirate glace nades CAUTION To reduce the risk of electric shock disconnect WARNING Allow the glass shades to cool completely before the electrical supply circuit to the fan before installing the removing light fixture WARNING Over lamping the light kit will result in the lights AN shutting down until the proper wattage of bulbs are installed NOTE Notice the location of the fan s slide switch This is the switch used to change the fan s directional rotation For more information on the operation o
43. to y o sus componentes est n 6 210 117 y otras patentes pendientes Pieza Descripci n Cantidad F faspa CE 5 Soporte de aspa con tornillos preinstalados fH Pamtalade vidrio J s i Bombitas m ximo de sow Control remoto bater a incluida INICIOS CS HAMPTONBAY COM Para obtener asistencia llama al 1 877 527 0313 Instalaci n OPCIONES DE MONTAJE ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica u otras lesiones instala s lo en una caja el ctrica clasificada como apropiada para sostener ventiladores de 15 9 kg o menos y usa s lo los tornillos incluidos con la caja el ctrica Las cajas el ctricas utilizadas com nmente para el soporte de art culos de iluminaci n pueden no servir como soporte de ventilador y tal vez deban reemplazarse En caso de duda consulta a un electricista calificado Si tu ventilador de techo no tiene una caja de montaje aprobada por UL instala una siguiendo las instrucciones a continuaci n Desconecta la energ a retirando los fusibles o apagando los cortacircuitos Asegura la caja el ctrica directamente a la estructura del edificio Usa sujetadores y materiales apropiados La caja el ctrica y su soporte deben poder sostener el peso completo del ventilador en movimiento al menos 15 9 kg No uses una caja el ctrica de pl stico Las ilustraciones a continuaci n muestran tres formas distintas de montar
44. y not apply to you The retailer shall not be liable for incidental consequential or special damages arising out of or in connection with product use or performance except as may otherwise be accorded by law Some states do not allow the exclusion of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties Shipping costs for any return of product as part of a claim on the warranty must be paid by the customer Contact the Customer Service Team at 1 877 527 0313 or visit www HamptonBay com Pre Installation SPECIFICATIONS DOOR Pom oe e 18 3 Ibs 20 9 Ibs san pow m w om eo sg Pa fe ja NOTE These are approximate measures They do not include the amps and wattage used by the light kit TOOLS REQUIRED O Phillips Fiat blade screwdriver i screwdriver Adjustable Electrical wrench O tape Step ladder 3 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Pre Installation continued HARDWARE INCLUDED A NOTE Hardware not shown to actual size E2 B cC DD EE Part Description Guamiy Part Description Guanti an tra biade bracket screw o frer O Extra lock washer e Locking pin Past wire connector FE Rubber gasket Pre Installation
Download Pdf Manuals
Related Search
Related Contents
2008 - Pacbrake USBEE DX TEST POD USERS MANUAL de handleiding Manuale Utente Per Minitorce A Gas Valex Cod. 1850122 Swift™ FX La Mère Michel a lu N°3 (hiver 2008-2009) IP4512_Optimus San Remo_QG_Por_03_130311.indd Trane 120R9V User's Manual User`s Manual Clamp-on Power Datalogger Model - Cole Copyright © All rights reserved.