Home

the great outdoors by Minka Lavery 72371-615B Instructions / Assembly

image

Contents

1. INSTALLATION INSTRUCTIONS Model 72371 READ AND SAVE THESE INSTRUCTIONS WARNING SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER AVERTISSEMENT COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR PREPARING FOR INSTALLATION Fig 1 Fig 1 1 Shut off power at the circuit breaker avertissement couper le courant au niveau des fusibles ou du disjoncteur and remove the old fixture including mounting hardware 2 Carefully unpack your new fixture and lay out all the parts in a clear area Take care not to misplace any small parts necessary for installation 3 Unscrew the screws I and separate the back plate H from cage J and remove cap nuts G 4 Thread the two studs B into the pre drilled holes in the circular strap C Part A 020 spaced the same distance apart as the holes in the back plate H C Set then tighten with the hex nut E Note The length of l studs B into circular strap C may be adjusted if m Circular Strap necessary Ground screw 1 5 Attach circular strap C Part A 020 using mounting screws F Part 8 32 1 L to the outlet hi Mounting screws 2 box A Fig 1 CONNECTION THE WIRES Fig 2 6 Connect the electrical wires as shown in Fig 2 making sure that all wire connectors are secured If your outlet box has a ground wire
2. green or bare copper connect the fixture s ground wire to tt Otherwise connect the fixture s ground wire directly to the circular strap using the green screw D Part 8 32 1 3 L provided GREEN OR BARE COPPER GROUND BARE COPPER GROUND FINISHING THE INSTALLATION Fig 1 7 Align back plate H onto studs B and secure with cap nuts G Fig 1 8 Install 2 35W GU10 bulbs three bulbs included in Fig 3 accordance with the fixture specification DO NOT EXCEED THE MAXIMUM WATTAGE RATING NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE 9 Align cage J to back plate H and secure with screws l top and bottom 10 To prevent moisture from entering the outlet box A and causing a short use clear silicone sealant to outline the outside of fixture back plate H where it meets the wall leaving a space at bottom to allow moisture a means to escape Fig 3 Me pu TN Caulking Rarknlata Your installation is now complete Return power to the m outlet box and test the fixture efh a merican IMPORTANT FIXTURE SHOULD BE INSTALLED BY A CN US Helali NO QUALIFIED ELECTRICIAN TO ENSURE PROPER WIRING _ _ association AND INSTALLATION Intertek

Download Pdf Manuals

image

Related Search

Related Contents

URIARTE SAFYBOX  HP C2K99UA User's Manual  取扱説明書 DXマクロポート87  Sony PCG-R505ELK Safety Information  Nouveau - ICC  IP1723FR rev. 2010-10-11  Bandridge VYP1103 coaxial connector    Mode d`emploi Affichage d`énergie et de météo  Manuel d`utilisation  

Copyright © All rights reserved.
Failed to retrieve file