Home

Worldwide Lighting W83093C39 Installation Guide

image

Contents

1. Make sure that the electrical supply to the chandelier is turned off at the main fuse or circuit breaker before doing any installation Worldwide lighting is not responsible for unprofessional wiring Frame Assembly Diagragram Q NA UN TA fe ES I A N FEN IN AIN Y CANOPY INSTALLATION INSTRUCTIONS Please read all instructions carefuly Before you proceed to install make sure that the power supply is turned off and off until installation is complete Please note that each part has been asigned a letter Please proceed in an alphabetical order A Existing Electrical Box B Crossbar C Crossbar Screws D Metal Plate E Crossbar Bracket F Neutral Conductor G Hot Wire H Junction Caps I Ground Wire J Wire Attach the Crossbar B to the existing electrical box A using the two crossbar screws E which are not supplied and should already be in your box WARNING Frame Assembly Instructions CONTENTS ARE FRAGILE HANDLE WITH CARE The metal frame and crystal components of this chandelier are very delicate Please have extreme caution when unpacking and installing Installation Please read all instructions careful ly Before you proceed to install make sure that the power supply is turned off and WARNING l remains off until installation is complete ee m please note that each part has been assigned a number After passing the main electrical wire through the 10mm pipe and pleas
2. W 83093039 D39 H34 L12 6 We are dedicated to providing the finest quality of crystal chandeliers for our customers Our master craftsman and designers pay their full attention to detail prompt and efficient service Enclosed are detailed instructions on how to properly install your chandelier Please read all instructions thoroughly If you have any questions please feel free to call our toll free chandelier hotline at 1 855 411 8999 C US Crystal Dressing Instructions CANOPY PARTS LIST W83093C39 When dressing the chandelier with the crystals please remember Existing Electrical Box to wear either rubber or cotton gloves So as to prevent any damage or smudging on the crystals Crossbar Screws Crossbar Screws x 2 not srpplied 18mmX1 C 2 ER 18mmX1 18mmX17 ur Canopy EI 2 5 2 5 4 96strings l6strings 48strings Chains 6strings Glass Bowl fy 18mmX7 E G 2 18mmX3 2 18mmX8 EN Glass crafts 4 WOW 12strings 12strings 8strings istring Wire Connector I 18mmX5 ra 18mmX4 f 18mmX4 e Shrinkable tube fe 18mmX14 _18mmX1 Cable tie 12strings 6strings Ground Wire WM A WARNING Crystal Dressing Diagram CONTENTS ARE FRAGILE W83093C39 HANDLE WITH CARE The metal frame and crystal components of this chandelier are very delicate Please have extreme caution when unpacking and installing When dressing the chandelier WARNING l with the crystals pleas
3. ass parts 11 All electrical components must be installed by a licensed electrician and in accordance with the National Electrical Code It must be in the appropriate local electrical codes Make sure that the electrical supply to the chandelier is turned off at the main fuse or circuit breaker before doing any installation Worldwide lighting is not responsible for unprofessional wiring blue wire Then connect to the neutral wire and double colored Lamp Body 02 match
4. e proceed in a numerical order connecting the pipe to the top main body connector place all remaining pieces as shown in numerical order and in the orientation depicted Refer to the parts list to avoid confusion between parts CAUTION Rated 110v 130v 60Hz bulb E12 40W maximum 2 Take care to avoid damage to the surface of lighting and wire Wearing gloves is recommended when installing 3 Connect black or red wire of the lighting to the white or Assembly Lamp Body 01 Install Crossbar with J Box and then Fixed the Canopy 03 Join the Lamp Body 01 and crossbar 02 with Chains 04 Make sure the positive and negative charges of wire and correctly screw the connect point or bare copper wire to the ground wire with the junction cap 4 Never install lighting on damp ceiling The room should be Make sure the main wire is enough long and keep the rest dry and well ventilated wire in the 4 J box 5 Keep lighting away from acid alkali and other corrosive As the crystal pressing instruction hang the crystal chemical or gas Clean with soft cloth only e lighting S 6 Installation must be carried out by qualified electrician HERA u ONES only Ta Disconnect the power before installing cleaning or replacing the lamp 8 Never cover the lighting when power is connected 9 Fixture must be secured when installing the ceiling tube chain pipe and other connecting parts 10 Take care to avoid damage when installing gl
5. e remember to wear either rubber or cotton P A y y A gloves So as to prevent any After passing the main electrical wire through the 10mm pipe and damage or emdbins on the enpstals connecting the pipe to the top main body connector place all remaining pieces as shown in numerical order and in the orientation depicted Refer to the parts list to avoid confusion between parts CAUTION 1 Rated 110v 130v 60Hz bulb E12 40W maximum 2 Take care to avoid damage to the surface of lighting and wire Wearing gloves is recommended when installing 3 Connect black or red wire of the lighting to the white or en blue wire Then connect to the neutral wire and double colored U or bare copper wire to the ground wire de A 4 Never install lighting on damp ceiling The room should be dry and well ventilated 5 Keep lighting away from acid alkali and other corrosive chemical or gas Clean with soft cloth only 6 Installation must be carried out by qualified electrician only 7 Disconnect the power before installing cleaning or replacing the lamp 8 Never cover the lighting when power is connected 9 Fixture must be secured when installing the ceiling tube chain pipe and other connecting parts 10 Take care to avoid damage when installing glass parts 11 All electrical components must be installed by a licensed electrician and in accordance with the National Electrical Code It must be in the appropriate local electrical codes

Download Pdf Manuals

image

Related Search

Related Contents

Trimble 5700-5800 - Al  DYNACAM 10 USER MANUAL - Norton Associates Engineering    3D TV BOX - Clatronic  Setup, Service  取扱説明書  MANUALE OPERATIVO  Oregon Scientific RMR382 weather station  CONTENT - Dhaka.net  

Copyright © All rights reserved.
Failed to retrieve file