Home
Total Pond MF750UV Installation Guide
Contents
1. Do not pump heated liquids Do not let the unit run dry Unit must be completely submerged up to the flotation ring for proper operation and cooling e Operate in fresh water only Avoid heavily chlorinated water and water with high pH levels e Do not lift the unit by its power cord CAUTION e UV light may cause irritation to the skin and or eyes Avoid exposure 1 e DANGER ULTRAVIOLET RADIATION disconnect power before replacing lamp e Prolonged or repeated exposure to UV light may have adverse physical effects including severe damage to your skin and eyes Seek immediate medical attention for overexposure to UV radiation e This light assembly has not been investigated for use in swimming pools or hot tubs PREPARATION Before beginning assembly or operation of product make sure all parts are present Compare parts with package contents list and diagram above If any part is missing or damaged do not attempt to assemble install or operate the product Contact customer service for replacement parts e Estimated Assembly Time 5 minutes e Tools Required for Assembly Philipshead screwdriver string rock OPERATION INSTRUCTIONS 1 Choose a fountain head for the desired water effect and assemble your choice as shown in Fig 1 2 If desired anchor the Pond Boss in the pond using a heavy object such as a rock and some string Cut a length of string slightly longer than the depth of the pond Tie one end of the s
2. ITEM MF750UV SS Pond Boss TotalPond REMINDER Questions problems missing parts Before returning to your CALL 1 888 412 6001 retailer call our customer service department at l l 1 888 412 6001 8 a m 6 p m EST Monday Friday or email BEFORE RETURNING TO STORE us at customercare geoglobalpartners com Or visit our website www totalpond com PACKAGE CONTENTS Part Description Quantity A Pond Boss 1 B Waterspray nozzle 1 C Waterbell nozzle insert 1 D Trumpet nozzle insert 1 E Lower fountain head nozzle 1 A WARNINGS AND CAUTIONS WARNING e Risk of electrical shock This unit is supplied with a grounding conductor and grounding type attachment plug To reduce the risk of electric shock be certain that it is connected only to a properly grounded grounding type receptacle GFCI e Do not exceed 120 volts e Always disconnect unit from the power source before beginning any maintenance or work on the unit e Inspect cord for damage before installation and or maintenance Replace the entire pump assembly if damage is found e Do not remove the grounding pin from the power cord plug e Risk of electrical shock This unit has not been investigated for use in swimming pools or marine areas CAUTION e This unit has been evaluated for use with fresh water only Use a proper power source as indicated on the unit label Keep the cord away from high temperatures or other heat sources
3. p housing Locking nut Lamp holder Small locking nut Inlet Foil reflector Glass tube UV bulb BIN lt x S lt c 4 o a0 vJo 2Z2 E Ja z o a m olo a a Printed in China LIMITED WARRANTY All pumps and electrical products are warranted to the user against defective material and workmanship under normal working conditions This warranty period begins on the date of purchase by the original purchaser All TotalPond electrical products are warranted to the user against defective material and workmanship under normal working conditions for 1 year from the date of purchase All TotalPond liners are warranted to the user against defective workmanship under normal working conditions for 20 years from the date of purchase All other TotalPond product is warranted to the user against defective material and workmanship under normal working conditions for 90 days Application Warranty covers only properly installed and maintained units Pump warranty is limited to applications pumping fresh water in a pond or fountain only Other liquid applications or extreme temperature uses must be approved in writing by the manufacturer Receipt and product date code are required for warranty claims Warranty Claim Warranty claims must be made by calling customer service at 1 888 412 6001 If the item is dete
4. rifier portion of the unit require cleaning Before attempting to disassemble the Pond Boss or clean the pump UV clarifier or any portion of the unit always disconnect the unit from the power source Disassemble the unit in accordance with the Disassembly Procedure section of this instruction sheet e Cleaning the Pump Insure the pump is disconnected from all other components comprising the unit Inspect the pump by removing the front screen and impeller assembly and clean parts of the pump and clean in warm soapy water Reassemble the pump and reposition and connect the low voltage power cables To maximize the performance of the UV clarifier portion of the unit periodically disassemble the unit to clean dirt and debris from the exterior of the glass tube and reflector located in the lamp housing IMPORTANT NOTE Be sure that the entire unit is completely dry and gaskets are properly seated when reassembling the UV clarifier Failure to do so will result in water leakage which can cause damage to the light unit as Disconnect the UV light from the outlet Be sure to allow sufficient time for the light to cool before disassembling the light 2 Unscrew the locking ring and pull out the light unit 3 Carefully pull out the glass tube holder by twisting and then pull out 4 Use warm soapy water to clean the glass tube Be sure to use biodegrable soap 5 Reassemble the UV clarifier and be sure that all gaskets and o
5. rings are seated properly TROUBLESHOOTING If the LED lights fail to operate e Check to make sure the power cord is plugged in and the light is getting power and the unit is getting power If the UV Clarifier fails to operate e Check bulb to make sure that it has not burned out Replace the bulb as necessary or after every season Bulbs are available by calling the customer service department If the pump fails to operate e Check to make sure the power cord is plugged in the pump is getting power and the pump is fully submerged e Remove the inlet screen and or pump cover and impeller cover to expose the impeller Turn the impeller to ensure that it is not broken or jammed If the performance of the pump is not satisfactory or the pump does not flow evenly e Check to make sure the pump is completely submerged in water e Check to make sure the impeller filter pad and the housing are clean clear of debris e Check the pump outlet and any tubing fountains spitters etc for kinks or obstructions e Adjust flow control REPLACEMENT PARTS LIST For replacement parts call our customer service department at 1 888 412 6001 8 a m 6 p m EST Monday Friday Description Waterspray nozzle Waterbell nozzle insert Trumpet nozzle insert Lower fountain head nozzle Flow control knob Front cover Locking ring Impeller cover Shaft support Washer Shaft Impeller assembly Float upper Float lower Screw Brace Plug seal Filter pad Lam
6. rmined to be defective you will be given authorization to return the defective part s freight pre paid along with proof of purchase Disposition The manufacturer will make a good faith effort for prompt disposition regarding all warranty claims Returned product will be inspected to determine cause of failure before warranty is applied Warranty does not cover any costs associated with the shipping handling installation or removal of products or parts subject to this warranty For products damaged in transit a claim should be filed with the carrier Disclaimer Any oral statements made about the product by the seller the manufacturer the representatives or any other parties do not constitute warranties should not be relied upon by the user and are not part of the contract for sale The seller s and manufacturer s only obligation and buyer s only remedy shall be for the manufacturer to either replace and or repair at the manufacturer s sole discretion the product as described above Neither seller nor the manufacturer shall be liable for injury loss or damages for lost profits lost sales injury to person or property or any other incidental or consequential loss arising from any cause whatsoever no matter whether based upon warranty contract negligence or other misuse and the buyer and user agree that no other remedy shall be available to them Before using the buyer and user shall determine the suitability of the product for
7. the intended use and assume all risk and liability whatsoever in connection therewith The warranty and remedy described in this limited warranty is an exclusive warranty and remedy in lieu of any other warranty or remedy expressed or implied All other warranties and remedies are hereby expressly excluded including but not limited to any implied warranty of merchantability of fitness for any particular purpose This warranty gives the buyer and user specific legal rights and buyer and user may also have other rights which vary from state to state Some states do not allow exclusions or limitations of incidental or consequential damages so the above limitations or exclusions may not apply to you CALL 1 888 412 6001 BEFORE RETURNING TO STORE
8. tring to the anchor and the other end to the ring at the bottom of the float Fig 2 3 Place the Pond Boss into the water and connect to a proper power source Fig 3 DISASSEMBLY PROCEDURE In order to insure optimal operation of the Pond Boss the following procedures should be performed periodically When the performance of the water flow through the fountain head is reduced it is an indication that cleaning of the unit is needed 1 Unplug the power cord and then carefully remove the Pond Boss assembly from the pond Fig 4 2 Turnthe Pond Boss assembly upside down Remove the locking screw Fig 5 3 Remove the fountain head and the top locking nut Then remove the top cover Fig 6 4 Twist the top section counterclockwise Then pull the top section from the lower Unscrew the wire connector that connects the top section to the rest of the unit Fig 7 5 Lift the pump and filter assembly up from the fountain NOTE In order to extract the filter assembly from the flotation basket the main power cord must be fed up through the bottom of the flotation basket Fig 8 6 Remove the filter pad and rinse until it is clean Then reassemble the pump and filter assembly Fig 9 CARE AND MAINTENANCE e General e A visible drop in waterflow or increased algae in the pond is your indication that filter pad pump and or UV cla