1. INSTALLATION INSTRUCTIONS CONTINUED 6 Referring to the Using Push In Fittings section insert the blue tubing into the faucet adapter fitting making sure the end of tub ing is firmly seated Hold the filter head assembly away from the wall press other end of tubing into outlet side as indicated by arrow on filter head assembly see Figure 4A N Take the remaining tubing slip the compression hex nut and 3 8 Outlet to ferrule onto the tubing position the tapered end of the ferrule i away from the hex nut and put in the tube insert See Figure 5 Equipment Fasten this assembly tightly onto 3 8 cold water supply outlet Figure 4 See Figure 6 Pull on tube to make sure a good connection has been made Connect other end to the inlet side of the filter head assembly as indicated by arrow see Figure 4B Place filter head assembly holes over mounting screws and press wv down to lock into place Tighten the screws for a secure fit eo Figure 5 co Insert filter in filter head assembly Turn filter one quarter turn to the right until it stops When fully engaged the top surface of the filter will be flush with the bottom of the filter head assembly The color label will face forward 7 6 10 Turn on water and open faucet to flush air from the system Flush 10 gallons through system before use approximately 5 to 7 5 minutes Close sink faucet The system is now ready for use Figure 6 Note
2. Installation and Operating Instructions For AP Easy Full Flow Drinking Water Systems INSTR2111 0609 Installer Please leave manual with homeowner eM SAFETY INFORMATION Read understand and follow all safety information contained in these instructions prior to installation and use of the AP Easy Full Flow Drinking Water Systems Re tain these instructions for future reference Intended use The AP Easy Full Flow Drinking Water Systems are intended for use in filtering potable water in homes and has not been evaluated for other uses The system is typically installed under a sink and must be installed by qualified professional installers according to these installation instructions EXPLANATION OF SIGNAL WORD CONSEQUENCES Indicates a potentially hazardous situation which if not avoided A WARNING could result in death or serious injury and or property damage CAUTION Indicates a potentially hazardous situation which if not avoided may result in property damage WARNING To reduce the risk associated with ingestion of contaminants Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts EPA Establishment 070595 CT 001 To reduce the risk associated with a hazardous voltage Do not install near electric wiring or piping which
3. Utilisation du produit Ce syst me d eau potable AP Easy Full Flow est destin filtrer l eau potable la maison il n a pas t valu pour d autres utilisations Ce syst me est g n ralement plac sous un vier et doit tre install par un installateur qualifi en respectant ces directives d installation EXPLICATION DES CONS QUENCES LI ES AUX MOTS INDICATEURS Indique une situation potentiellement dangereuse qui si elle n est AMISE EN GARDE pas vit e pourrait entrainer la mort des blessures graves et des d g ts mat riels Indique une situation potentiellement dangereuse qui si elle n est AVERTISSEMENT pas vit e pourrait occasionner des d g ts mat riels A MISE EN GARDE Pour r duire les risques associ s l ingestion de contaminants Ne pas utiliser avec de l eau aui n est pas s re au point de vue microbiologique ou de qualit incertaine sans assurer une d sinfection ad quate avant ou apr s le syst me Les syst mes de r duction des sporocystes peuvent tre utilis s avec de l eau d sinfect e qui est sus ceptible de contenir des sporocystes filtrables tablissement EPA n 070595 CT 001 Pour r duire les risques d lectrocution Ne pas installer pr s de c bles lectriques ou de conduites d eau susceptibles d tre en dommag s par la perceuse au moment de fixer le support du filtre AVERTISSEMENT Afin de r duire les risques de dommages mat riels associ s aux fuit
4. estar por lo menos a 2 pulgadas y media del piso del gabinete del fregadero para facilitar el cambio del cartucho Instale los tornillos pero solamente hasta la mitad de manera que pueda f cilmente poner el soporte contra la pared antes de ajustar firme mente los tornillos Correcto Incorrecto 4 Determine la longitud de tuber a requerida desde el Figura 2 soporte cabezal del filtro hasta el grifo y desde la l nea de suministro de agua hasta el soporte cabezal del filtro manteniendo la tuber a en su lugar y de esta manera ase gurar que tiene la longitud necesaria No tuerza la tuber a ya que esto impedir el flujo de agua De ser necesario pase la tuber a por los costados para evitar que se doble Corte la tuber a verticalmente con un cuchillo Vea la Figura 2 5 Instale el accesorio del adaptador del grifo al grifo Deber calzar apretadamente No lo apriete demasiado Vea la Figura 3 Figure 3 Uso de los accesorios a presi n Para conectar la tuber a Para liberar la tuber a Empuje la tuber a todo lo posible La tuber a debe pasar la junta Empuje el casquillo gris para liberar la tuber a t rica y llegar hasta el tope trasero Tire del tubo para verificar Mientras agarra la portapieza tire la tuber a hacia que est seguro fuera PRECAUCI N Para reducir el riesgo asociado con el da o a la propiedad debido a p rdidas de agua Aseg rese que todas las tuber as y accesorios est n asegurada
5. F 38 C El cartucho desechable del filtro debe cambiarse cada seis meses o seg n el ciclo de servicio especificado No lo instale cerca de ca erias de agua que pudieran estar en el lugar de perforaci n cuando se selecciona el lugar para montar el soporte Instale el filtro en una posici n tal que se prevenga la posibilidad de golpearlo con otros art culos usados en el lugar de la instalaci n canastas de desechos etc Aseg rese que todas las tuber as y accesorios est n aseguradas y sin p rdidas No lo instale en contacto directo con la luz del sol NOTIFICACI N IMPORTANTE Cierre el suministro de combustible al calentador de agua luego de cortar el agua No observar las instrucciones podr a cancelar la garant a Deje un espacio libre m nimo de 5 cm 2 debjo del filtro para facilitar el cambio del cartucho Instalelo con los puertos de entrada y salida como se indican Aseg rese de no invertir las conexiones INICIACI N Las piezas y materiales incluyen Cartucho del filtro Ensamblaje del cabezal del filtro Tuber a de 3 8 de pulgada Adaptador del grifo de 3 8 x 1 2 pulgada Tuerca hexagonal de compresi n de 3 8 de pulgada 6 Regat n de 3 8 de pulgada 7 Accesorio del tubo de 3 8 de pulgada 8 Tornillos de montaje Phillips n 2 Tornillos de montaje Phillips n 2 Ensamblaje del cabezal del filtro MAN Cartucho del filtro Adaptador del grifo de 3 8 x 1 2
6. ins rer le tuyau dans le raccordement poussoir S assurer que le tuyau est coup bien droit Sinon tailler de nouveau En cas de fuite v rifier que le joint torique est bien appuy dans sa rainure L eau ne s coule pas du robinet du syst me d eau potable S assurer que la soupape de la canalisation d alimentation principale est ouverte permettant l eau de se rendre au filtre L eau semble brouill e ou de l air s coule du robinet du systeme d eau potable Laisser 38 litres 10 gal E U d eau couler travers le syst me avant utilisation environ 5 7 5 pour faire sortir tout l air et la poussi re de carbone du filtre et des canalisations d eau NOTES CNS 3M a 3M company CUNO Incorporated 400 Research Parkway Meriden CT 06450 USA Toll Free 1 800 222 7880 3M is a trademark of 3M Company ide 903 937 CUNO and Aqua Pure are trademarks of 3M Company used under license u a 2009 3M Company All rights reserved WWw aquapure com e www cuno com
7. may be in the path of a drilling tool when selecting the position to mount the filter bracket CAUTION To reduce the risk associated with property damage due to water leakage Read and follow Use Instructions before installation and use of this system Installation must comply with existing state or local plumbing codes Install on cold water lines only Protect filter from freezing Drain filter when room temperature drops below 40 F 4 4 C Do not install if water pressure exceeds 125 psi 862 kPa If your water pressure exceeds 125 psi you must install a pressure limiting valve Contact a plumbing professional if you are uncertain how to check your water pressure Do not install where water hammer conditions may occur If water hammer conditions exist you must install a water hammer arrester Contact a plumbing professional if you are uncertain how to check for this condition Do not install on hot water supply lines The maximum operating water temperature of this filter system is 100 F 38 C The disposable filter cartridge must be replaced every six months or at the specified service cycle Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket Mount filter in such a position as to prevent it from being struck by other items used in the area of installation waste baskets etc Ensure all tubing and fittings are secure and free of lea
8. pulgada Herramientas requeridas no se incluyen Taladro el ctrico se recomienda uno inal mbrico Llave ajustable Destornillador con cabeza Phillips e Cuchillo o cortador de tuber a Accesorio del tubo de 3 8 de pulgada Tuerca hexagonal o de compresi n de 3 8 de pulgada Regat n de 3 8 de pulgada Caliente COMO CAMBIAR EL FILTRO Cambie este filtro por lo menos cada seis meses Las condiciones del agua local y el volumen real de agua pueden afec tar la vida del filtro C mbielo si ocurre una ca da notable de presi n en el grifo INSTRUCCIONES PARA LA INSTALACI N Para uso con agua fr a solamente NOTA Saque los elementos de abajo del fregadero Ponga un recipiente para recolectar las peque as cantidades de agua que podr n salir cuando desconecte las l neas de suministro de agua 1 Cierre la v lvula de entrada de agua fr a y saque el tubo de suministro de agua existente y o el accesorio 2 Seleccione y marque un lugar debajo del fregadero que permite el acceso para cambiar el filtro 3 Usando el soporte cabezal del filtro como gu a sujete el Ensamblaje del cabezal del filtro a la pared con los tornil los de montaje Phillips n 2 suministrados Marque el lugar de los agujeros de manera tal que haya un espacio de 1 pulgada y media entre los tornillos vea la Figura 1 desde el centro de cada tornillo Cuando lo haya instalado el fondo del filtro deber
9. utile du filtre Remplacer si la pression de l coulement du robinet diminue de fagon marqu e DIRECTIVES D INSTALLATION utiliser uniquement avec de l eau froide REMARQUE Retirer les articles qui se trouvent sous l vier Placer un bassin pour recueillir les l gers coulements d eau qui peuvent se produire lors du d branchement des conduites d eau 1 Couper l arriv e d eau froide la canalisation d alimentation et retirer le tuyau et ou le raccord existant 2 S lectionner et marquer un emplacement sous l vier per mettant l acc s pour le changement de filtre 3 En utilisant la t amp te du filtre et son support comme guide fixer le module de t te du filtre au mur l aide des vis de fixation t te cruciforme n 2 Marquer l emplacement des trous de mani re ce qu il y ait 38 1 mm 1 1 2 po entre les vis voir figure 1 centre centre Une fois l installation termin e il doit y avoir un espace libre d au moins 6 4 cm 2 1 2 po sous le filtre pour faciliter le remplacement de la cartouche Installer les vis mais en les enfoncant seulement mi course afin Q Q de pouvoir facilement glisser le support au mur avant de terminer de les visser Zt Ad quat Non ad quat 4 D terminer la longueur de tuyau n cessaire pour relier la t te et le support du filtre au robinet et de la canalisation Figure 2 d alimentation en eau la t te et au support du filtre en tenant le tuyau en place
10. Assurez vous que tous les tuyaux et raccords sont solides et exempts de fuites Ne pas installer dans un endroit expos la lumi re directe du soleil REMARQUES IMPORTANTES Couper l alimentation en combustible du chauffe eau apr s avoir coup l eau Ne pas se conformer ces directives pourrait annuler la garantie Laisser un espace libre d au moins 5 1 cm sous le filtre pour faciliter le remplacement de la cartouche Installer avec les orifices d entr e et de sortie aux endroits indiqu s sur l tiquette S assurer de ne pas intervertir les raccordements D MARRAGE Pi ces et mat riel inclus 1 Cartouche filtrante 2 Module de t te du filtre fron Aiie 3 Tuyau de 3 8 po cruciforme n 2 4 Adaptateur de robinet 3 8 po x 1 2 po Module de 5 Ecrou compression hexagonal 3 8 po t te du filtre 6 Bague d extr mit 3 8 po 7 Adaptateur male 3 8 po 8 Vis de fixation t te cruciforme n 2 Cartouche Outils n cessaires Adaptateur de robinet filtrante 3 8 po x 1 2 po non compris Perceuse sans fil recommand e Cl anglaise r glable Tournevis cruciforme Phillips Couteau lame de rasoir ou coupe tuyau crou compression hexagonal 3 8 po Bague d extr mit 3 8 po I an m le REMPLACEMENT DU FILTRE Remplacer ce filtre au moins tous les six mois La composition de l eau et le volume peuvent avoir une incidence sur la dur e de vie
11. CARTOUCHE FILTRANTE 1 Placer un r cipient sous le filtre afin de recueillir tout r sidu d eau lors du changement de cartouche 2 Saisir la cartouche et tourner vers la gauche dans le sens inverse des aiguilles d une montre jusqu ce qu elle ne puisse aller plus loin l eau s arr te automatiquement Tirer doucement sur la cartouche pour l enlever 3 Retirer le bouchon sanitaire protecteur ROUGE de la cartouche neuve 4 S assurer que les joints toriques de la cartouche sont bien en place et ins r s dans les rainures humidifier les joints toriques avec de l eau NE PAS utiliser de produits base de p trole pour lubrifier les joints toriques 5 Aligner les guides de la nouvelle cartouche filtrante avec la t te et l ins rer dans le module de t te Tourner la car touche vers la droite dans le sens des aiguilles d une montre jusqu ce qu elle ne puisse aller plus loin 6 Laisser 38 litres 10 gal U d eau couler travers le syst me avant utilisation environ 5 7 5 PROBL MES ET SOLUTIONS Fuites d eau se produisant aux raccordements poussoir Enfoncer le tuyau aussi profond ment que possible Si la fuite persiste couper l eau au robinet d alimentation principal et retirer la canalisation d alimentation en poussant sur l anneau de raccord tout en tirant sur le tuyau Inspecter le tuyau pour rep rer toute fente ou gratignure Si le tuyau est fendu ou gratign couper tout simplement cette portion et r
12. White tube from head is pressure relief outlet FILTER CARTRIDGE REPLACEMENT INSTRUCTIONS Place pan under filter to collect any residual water during cartridge change out po Grasp cartridge and turn to the left counterclockwise until cartridge comes to a complete stop water automatically turns off Gently pull cartridge downward to remove 3 Remove RED sanitary protective cap from new cartridge 4 Ensure that o rings are present on the cartridge and are seated into grooves moisten o rings with water DO NOT use any petroleum products to lubricate the o rings 5 Align tabs of new filter cartridge with existing filter head and insert new filter cartridge into head Turn cartridge to the right clockwise until cartridge stops 6 Flush 10 gallons through system before use approximately 5 to 7 5 minutes TROUBLESHOOTING GUIDE Water Leaks at Push In Connections Push tubing in as far as it will go If leaking continues shut off water at the original valve and remove water line by push ing in on the connector collar while pulling the tubing away Inspect tubing for cracks and scratches If tubing is cracked or scratched simply cut that portion away and reinsert tubing into push in fitting Make sure tubing is cut straight If not recut If water leaks please verify that the o ring is properly seated in its groove Water Does Not Flow From The Drinking Water System Faucet Check to see if the main water line valve is o
13. ark a location under the sink that allows access for filter change 3 Using filter head bracket as a guide fasten Filter Head Assembly to wall with 2 Phillips mounting screws supplied Mark hole locations so that there is 1 1 2 between the screws see Figure 1 from center of each screw When installed filter bottom should be at least 2 1 2 from sink cabinet floor to facilitate cartridge change Install screws but only halfway so you can easily slip the bracket to wall before firmly setting screws 4 Determine length of tubing required from filter head bracket to faucet and from water supply line to filter head bracket by Correct Incorrect holding tubing in place ensuring it is of appropriate length Do not kink tubing as this will impede water flow If neces Figure 2 sary loop tubing around to avoid it being kinked Cut tubing straight with a utility knife See Figure 2 5 Install faucet adapter fitting to faucet This should be a snug EZ fit Do not overtighten See Figure 3 Figure 3 Using Push In Fittings To Attach Tubing To Release Tubing Push tubing in as far as it will go Tubing must be inserted Push in grey collet to release tubing With collet past o ring and hit backstop Pull tube to ensure it is secured held pull tubing straight out CAUTION To reduce the risk associated with property damage due to water leakage Ensure all tubing and fittings are secure and free of leaks
14. e reste du tuyau faire glisser l crou compression hexagonal et la bague d extr mit 3 8 po sur le tuyau placer la partie amincie de la sortie Vers bague d extr mit en direction oppos e de l crou hexagonal et ins rer appareil l adaptateur m le voir figure 5 Fixer ce module solidement sur l arriv e Figure 4 d eau froide de 3 8 po voir figure 6 Tirer sur le tuyau pour s assurer qu il est solidement raccord Raccorder l autre extr mit l entr e du module de t te du filtre tel que l indique la fl che voir figure 4B 8 Positionner les orifices du module de t te sur les vis de fixation et abaisser pour verrouiller en place Resserrer les vis pour un ajustement solide we 9 Ins rer le filtre dans le module de t te du filtre Tourner le filtre un quart Figure 5 de tour vers la droite jusqu ce qu elle rencontre une r sistance Lorsque le filtre est bien install sa surface sup rieure se retrouve au m me niveau que le bas du module de t te du filtre L tiquette color e est orient e vers l avant 10 Ouvrir l arriv e d eau et le robinet afin d vacuer l air du syst me Laisser gt 2 38 litres 10 gal U d eau couler travers le syst me avant utili sation environ 5 a 7 5 Refermer le robinet de l vier Le syst me est maintenant pr t fonctionner Remarque Le tube blanc sortant de la t amp te est la soupape de d compression DIRECTIVES DE REMPLACEMENT DE LA
15. es d eau Lire et suivre le mode d emploi avant l installation et l utilisation de ce syst me L installation doit tre conforme aux codes d tat et de plomberie en vigueur utiliser uniquement sur une conduite d eau froide Prot ger le filtre du gel Vidanger le filtre si la temp rature ambiante tombe sous les 4 4 C 40 F Ne pas installer sur une conduite d eau dont la pression est sup rieure a 862 kPa 125 psi Sila pression est sup rieure a 862 kPa 125 psi il est n cessaire d installer une soupape de limitation de pression En cas de doute sur la mani re de v rifier la pression de l eau communiquer avec un plombier Ne pas installer o des coups de b lier peuvent se produire S il se produit des coups de b lier il est n cessaire d installer un dispositif antib lier En cas de doute sur la mani re de v rifier cette situation communiquer avec un plombier Ne pas installer sur la canalisation d alimentation en eau chaude La temp rature maxi mum de fonctionnement permise pour ce syst me de filtration est de 38 C 100 F Il faut remplacer la cartouche filtrante jetable au moins tous les six mois ou selon le cycle de vie indiqu Ne pas installer pr s de conduites d eau susceptibles d tre endommag es par la per ceuse au moment de fixer le support Installer le filtre dans une position le prot geant contre les risques de contact avec d autres objets utilis s dans la zone d installation poubelle etc
16. ks Do not install in direct sunlight IMPORTANT NOTES SHUT OFF FUEL SUPPLY TO WATER HEATER after water is shut off Failure to follow instructions may void warranty Allow a minimum of 2 5 cm clear space under filter to facilitate cartridge change Install with the inlet and outlet ports as labeled Make sure not to reverse connections GETTING STARTED Parts and Materials Included 1 Filter Cartridge 2 Filter Head Assembly 2 Philips 3 3 8 Tubing Hose 4 3 8 x 1 2 Faucet Adapter Filisi 5 3 8 Compression Hex Nut Head 6 3 8 Ferrule Assembly 7 3 8 Tube Insert o 8 2 Phillips Mounting Screws Filter P P Cartridge Tools Required not included 3 8 x1 2 Faucet Adapter e Drill Cordless recommended e Adjustable wrench e Phillips head screwdriver e Razor knife or tube cutter O 3 8 Compression Hex Nut Q 3 8 Ferrule 9 3 8 Tube Insert FILTER REPLACEMENT Change this filter at least every six months Local water conditions and actual volume of water can affect filter life Replace if a noticeable drop in pressure occurs at the faucet INSTALLATION INSTRUCTIONS For Use With Cold Water Only NOTE Remove items from under the sink Place catch basin there to collect small amounts of water that may run out when disconnecting water supply lines 1 Turn off cold water supply valve and remove existing water supply tubing and or fitting 2 Select and m
17. pen allowing water to flow to the filter Water Appears Cloudy or Air Comes Out of the Drinking Water System Faucet Flush 10 gallons through system before use approximately 5 to 7 5 minutes to remove any carbon fines or trapped air in the filter and water lines INFORMACI N DE SEGURIDAD Lea entienda y observe toda la informaci n de seguridad que se incluye en estas instrucciones antes de instalar y usar los sistemas de agua potable AP Easy Full Flow Retenga estas instrucciones como referencia futura Uso previsto El sistema de agua potable AP Easy Full Flow tiene por objeto ser usado en el filtrado de agua potable en viviendas y no ha sido evaluado para otros usos El sistema se instala general mente debajo del fregadero y un profesional calificado debe instalarlo de acuerdo a estas instrucciones de instalaci n EXPLICACION DE LAS CONSECUENCIAS DE LAS PALABRAS INDICADORAS Indica una situaci n peligrosa potencial la cual si no se evita po A ADVERTENCIA dria resultar en una lesi n seria o la muerte y o da o a la propiedad x Indica una situaci n peligrosa potencial la cual si no se evita PRECAUCION podr a resultar en da os a la propiedad A ADVERTENCIA Para reducir el riesgo asociado con la ingesti n de contaminantes No lo utilice con agua que sea microbiol gicamente insegura o de calidad desconocida sin la desinfecci n adecuada previa o posterior al sistema Los sistemas certificados para la reducci n de
18. pour s assurer que la longueur convient viter de plier le tuyau car cela nuirait du d bit de l eau Si n cessaire faire une boucle avec le tuyau afin d viter de le plier Couper le tuyau en ligne droite avec un couteau universel Voir figure 2 5 Installer l adaptateur de robinet au robinet L ajustement doit amp tre pr cis Ne pas trop serrer Voir figure 3 Figure 3 Utilisation de raccordements poussoir Fixation du tuyau D tachement du tuyau Enfoncer le tuyau aussi profond ment que possible Le tuyau doit tre Pousser le douille de serrage gris pour lib rer le ins r au del du joint torique et s appuyer sur la but e Tirer sur le tuyau tuyau En tenant la douille de serrage faire sortir pour s assurer qu il est solidement fix le tuyau en tirant dessus AVERTISSEMENT Atin de r duire les risques de dommages mat riels associ s aux fuites d eau Assurez vous que tous les tuyaux et raccords sont solides et exempts de fuites Douille de serrage DIRECTIVES D INSTALLATION SUITE 6 Tel que d crit dans la section Utilisation de raccordements poussoir B ins rer le tuyau bleu dans l adaptateur en s assurant que l extr mit du tuyau est bien appuy e loigner le module de t te du filtre du mur et enfoncer l autre extr mit du Entr e tuyau dans la sortie tel qu indiqu par la fl che qui se trouve sur la t te du filtre Voir figure 4A 7 Saisir l
19. quistes pueden usarse con agua desinfectada que podr a contener quistes filtrables N de establecimiento de la EPA 070595 CT 001 Para reducir el riesgo asociado con un voltaje peligroso No lo instale cerca de alambres el ctricos o cafier as que pudieran estar en el lugar de perforaci n cuando se selecciona el lugar para montar el soporte del filtro PRECAUCI N Para reducir el riesgo asociado con el da io a la propiedad debido a p rdidas de agua Lea y observe las Instrucciones de uso antes de la instalaci n y uso de este sistema La instalaci n debe cumplir con los c digos de plomer a existentes locales y estatales Para uso con agua fr a solamente Proteja al filtro contra el congelamiento Drene el filtro cuando la temperatura ambiente cae por debajo de 40 F 4 4 C Nolo instale si la presi n del agua excede los 125 psi 862 kPa Sila presi n del agua ex cede los 125 psi debe instalar una v lvula que limite la presi n Consulte a un profesional de la plomer a si no est seguro sobre c mo verificar la presi n del agua No lo instale donde pudieran ocurrir situaciones de golpes de ariete Si existen situaciones de golpe de ariete debe instalar un supresor de golpes de ariete Consulte a un profesional de la plomer a si no est seguro sobre c mo comprobar si existe dicha situaci n No lo instale en la l nea de agua caliente La temperatura m xima de operaci n de este sistema de filtrado es 100
20. s y sin p rdidas Tope Casquillo trasero INSTRUCCIONES DE INSTALACI N CONTINUACI N 6 Usando la secci n Uso de los accesorios a presi n como referencia B inserte la tuber a azul en el accesorio del adaptador del grifo asegur n dose que el extremo de la tuber a est apretadamente asentado Mantenga el ensamblaje del cabezal lejos de la pared oprima el otro Entrada extremo de la tuber a hacia el lado de la salida como lo indica la flecha en el ensamblaje del cabezal del filtro vea la Figura 4A O 7 Tome el resto de tuber a pase la tuerca hexagonal de compresi n y M el regat n de 3 8 de pulgada por la tuber a poniendo el lado c nico Salida al del regat n mirando en la direcci n opuesta a la tuerca hexagonal y equipo ponga el accesorio del tubo vea la Figura 5 Ajuste este ensamblaje Figura 4 apretadamente a la salida del suministro de agua de 3 8 de pulgada vea la Figura 6 Tire del tubo para asegurarse que la conexi n es buena Conecte el otro extremo al lado de la entrada del ensamblaje del cabezal del filtro como lo indica la flecha vea la Figura 4B 8 Ponga los agujeros del ensamblaje del cabezal del filtro sobre los wv tornillos de montaje y oprima hacia abajo para trabarlo en su lugar Ajuste los tornillos para lograr un calce apretado Figura 5 9 Inserte el filtro en el ensamblaje del cabezal del filtro Gire el filtro
21. scargue 10 galones a trav s del sistema antes de utilizarlo aproximadamente entre 5 y 7 5 minutos GU A DE DESPERFECTOS P rdidas de agua en las conexiones a presi n Empuje la tuber a todo lo posible Si contin a saliendo agua corte el agua en la v lvula original y saque la l nea del agua empuj ndola en el cuello del conectador mientras saca la tuber a Inspeccione la tuber a para ver si est rajada o perforada Si la tuber a est rajada o perforada simplemente corte dicha parte y vuelva a insertar la tuber a en el accesorio a presi n Aseg rese de que el corte de la tuber a sea recto Caso contrario vuelva a cortarlo Si hay una fuga de agua verifique que la junta t rica est debidamente colocada en su ranura No sale agua del grito del sistema de agua potable Verifique para ver si la v lvula principal de la l nea de agua est abierta permitiendo que llegue agua al filtro El agua parece turbia o sale aire del grifo del sistema de agua potable Descargue 10 galones a trav s del sistema antes de utilizarlo aproximadamente entre 5 y 7 5 minutos para eliminar las part culas de carb n o las burbujas de aire atrapadas en el filtro y las l neas de agua CONSIGNES DE S CURIT Avant d installer et d utiliser les syst mes d eau potable AP Easy Full Flow s assurer de lire comprendre et suivre toutes les consignes de s curit que ren ferme ce mode d emploi Conserver ce mode d emploi pour consultation future
22. un cuarto de vuelta hacia la derecha hasta que se detenga Cuando est completamente sentado la superficie de arriba del filtro estar al ras del fondo del ensamblaje del cabezal del filtro La etiqueta de colores oe eS deber mirar hacia delante gt Z iss 10 Abra el agua y el grifo para purgar el aire del sistema Descargue 10 Z galones a trav s del sistema antes de utilizarlo aproximada mente entre 5 y 7 5 minutos Figura 6 Cierre el grifo del fregadero El sistema est ahora listo para ser usado Nota El tubo blanco del cabezal es la salida de la presi n INSTRUCCIONES PARA CAMBIAR EL CARTUCHO DEL FILTRO 1 Ponga una fuente debajo del filtro para recolectar los residuos de agua durante el cambio de cartucho 2 Agarre el cartucho y girelo hacia la izquierda contrario a las agujas del reloj hasta que el cartucho se detenga com pletamente el agua se corta autom ticamente Tire suavemente el cartucho hacia abajo para sacarlo 3 Saque la tapa de protecci n sanitaria ROJA del nuevo cartucho 4 Aseg rese que las juntas t ricas est n instaladas en el cartucho y asentadas en las ranuras humed zcalos con agua NO use productos con petr leo para lubricar las juntas t ricas 5 Alinee las leng etas del nuevo cartucho del filtro con el cabezal del filtro existente e inserte el nuevo cartucho en el cabezal Gire el cartucho hacia la derecha en el sentido de las agujas del reloj hasta que se detenga 6 De