Home

Halsey Taylor HTHB-HVRGRN8-WF Use and Care Manual

image

Contents

1. DETALLE DEL GRIFO RESISTENTE AL VANDALISMO DESCRIPTION DU BARBOTEUR RESISTANT AU VANDALISME Fig 3 Page 4 HVRGRN8WS 1C HVRGRN8WSNF 1C PUSH BUTTON MECHANISM MECANISMO DE BARRA DE EMPUJE 28 MECANISME DU BOUTON POUSSOIR Fig 4 Page 5 1000001739 Rev B 11 14 HVRGRN8WS 1C HVRGRN8WSNF 1C 7 16 BOLT HOLES FOR MOUNTING FASTENING UNIT TO WALL SCREWS UNIT CENTER LINE TOP COVER 36 BRACKET WASHERS amp SCREWS Bottle Filler Installation Instructions 1 Remove two 2 mounting screws with 5 32 Allen wrench holding top cover to Bottle Filler See Fig 6 Remove top cover Note do not discard mounting screws they will be needed to reinstall top cover 2 Remove wall mounting plate from Bottle Filler Place wall plate against wall on top of basin Center the wall plate side to side with the basin Mark the six 6 mounting holes with a pencil See Fig 2 3 Remove wall mounting plate from wall NOTE Mounting plate MUST be supported securely Add fixture support carrier if wall will not provide adequate support 4 Install wall mounting plate to wall using six 6 7 16 obround mounting holes mounting bolts not included See Fig 5 Use appropriate fasteners for your wall type 5 Feed power cord amp 3 8 water line through hole in tower basin gasket See Fig 7 6 Install gasket on bottom of bottle filler tower with gasket support bracket 2 washers amp 2 screws See Fig 8 7
2. UE WU WW LOG ud ul QI6 WG 8 2 Z 1000001739 Rev B 11 14 Page 3 IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON HANGER BRACKETS amp TRAP INSTALLATION 1 Remove hanger bracket fastened to back of cooler by removing one 1 screw 2 Mount the hanger bracket and trap as shown in Figure 2 NOTE Hanger Bracket MUST be supported se curely Add fixture support carrier if wall will not provide adequate support IMPORTANT 6 1 4 in 159mm dimension from wall to center line of trap must be maintained for proper fit e Anchor hanger securely to wall using all five 5 5 16 dia mounting holes 3 Install straight valve for 3 8 O D tube INSTALLATION OF COOLER 4 Hang the cooler on the hanger bracket Be certain the hanger bracket is engaged properly in the slots on the cooler back as shown in Fig 3 5 Loosen the two 2 screws holding the lower front panel at the bottom of cooler base and two 2 screws at the top Remove the front panel and set aside 6 Connect water inlet line See Note 4 of General Instructions 7 Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap Assemble the slip nut and gasket to the trap and tighten securely START UP Also See General Instructions HVRGRN8WS 1C HVRGRN8WSNF 1C IMPORTANTE TODO EL SERVICIO DEBERA SER EFECTUADO POR UNA P
3. 28528C Panel Left Rear SS Panel Retrovisor Izquierdo SS Panneau Arri re Gauche SS 28558C Panel Front Lower SS Panel Frontal Inferior SS Panneau Front Bas SS 0000001144 Tee 1 4 x 1 4 x 3 8 Tee 1 4 x 1 4 x 3 8 Tee 1 4 x 1 4 x 3 8 1000001602 Kit 75583C Elbow 5 16 1 4 Kit 75583C Codo 5 16 1 4 Coude Kit 75583C 5 16 1 4 1000001791 Kit Nipple Gasket Kit Pez n Empaque Kit Mamelon Joint See Filter Table Water Filter Kit When Provided Kit de Filtro de Agua Cuando Provisto Kit de Filtrage d Eau Si Fourni REPLACE WITH SAME COMPRESSOR USED REEMPLACE CON EL MISMO COMPRESORUSADO REMPLACEZ AVEC LE MEME SURPRESSEUR IN ORIGINAL ASSEMBLY EN EL ENSAMBLADO INICIAL QUE CELUI UTILIS ORIGINALEMENT NOTE All correspondence pertaining to any NOTA Toda la correspondencia relacionada con el en NOTE Toute correspondance au sujet des refroidis of the above water coolers or orders for repair friador de agua anterior o con una orden de reparaci n seurs d eau courante ou toute commande de pi ce parts MUST include Model No and Serial No piezas DEBER incluir el n mero de modelo y n mero de rechange DOIT inclure le num ro de mod le et le of cooler name and part number of replace de serie del enfriador el nombre y n mero de pieza de num ro de s rie du refroidisseur ainsi que le nom et ment part la pieza de repuesto le num ro de pi ce remplacer BOTTLE FILLER REPLACEMENT PART KITS ITEM N
4. Fish the purple wire single units or the purple and yellow wires two level units up through basin hole amp hole in gasket 8 For Single Model installations Attach the purple wire from cooler to the purple wire on the back of the unit Note yellow wire is not used 8a For Two Level model installations Attach the purple and yellow wires from coolers to the purple and yellow wires on the back of the unit purple to purple yellow to yellow 9 Lay Bottle Filler on water cooler basin and cut insulation from tube even with bottom of gasket remove this insulation from the 3 8 tube but do not discard Fish the power cord and waterline through the hole on top of water cooler NOTE To prevent scratching the basin place a towel or soft cloth over the entire basin when working above it 10 With the power cord wire s and waterline through hole on top of water cooler place Bottle Filler on the three 3 angled tabs protruding from the wall mounting plate installed on wall Make sure round boss in gasket fits in hole of basin See Fig 10 11 Once Bottle Filler is installed on wall plate tabs water line wire s and power cord are installed properly push top of Bottle Filler toward wall and line up top cover two 2 holes 12 Reinstall Top Cover on Bottle Filler See Fig 6 with two mounting screws from step 1 above Caution do not over tighten screws 13 Install remaining tube insulation to the water line from bottle filler connect Bott
5. PIEZAS LISTE DES PIECES PART NO DESCRIPTION DESCRIPCION DESCRIPTION 22897C Panel Bottom Dispenser Panel Dispensador Inferior Panneau Distributeur Inf rieur 45662C Button Push Bot n Bouton 28551C Hanger Bracket Fijador de Suspensi n Support de Suspension 1000001676 Basin Stainless Steel Estanque Acero Inoxidable Bassin Acier Inoxydable 35870C Power Cord Cable El ctrico Cordon d Alimentation 0000000768 Compressor Serv Pak EM 65 HHC Paquete de Serv del Compresor EM 65 HHC Trousse D entr Surpresseur EM 65 HHC 45736C Half Nut Regulator Tuerca medio Regulador Demi crou R gulateur 45737C Sleeve Push Button Manguito pulsador Manchon bouton poussoi 56033C Washer Arandela Rondelle 98731C Kit Regulator Spring Kit Regulador Primavera Kit R gulateur Printemps 55931C Cover Dispenser Bottom Cubierta Dispensador Inferior Couvercle Distributeur Inf rieur 98775C Kit Fan Motor Assy Blade Motor Shroud Kit Ventilador Motor Montaje Hoja Kit Ventilateur Moteur Assembl e Screws Nut Motor Cubierta Tornillos Tuerca Lame Moteur 56092C Tubing Poly Cut To Length Tuberia de Polietileno Corte a la longitud Tubes Poly thyl ne Couper a la Longueur 98899C Kit Hardware Kit Juego de Accesorios Kit De Visserie 55996C Strainer See General Instructions Filtro Bifurcado Vea Instrucciones Generales Grille Voir Directives G n rales 98481C Kit Bubbler Nipple Gasket Kit Borboteador Pez n Empaque Kit B
6. ARD SOFTWARE 1 To verify the software program of the control board the unit will need to be shut down and restarted The chiller if present does not need to be shut down and restarted 2 The units lower panel must be open to access the power cord and wall outlet 3 Shut down the unit by unplugging the power cord from the wall outlet 4 Restart the unit by plugging the power cord back into the wall outlet 5 Upon start up the bottle count display will show the software designation of BF 11 6 Reference the BF11 instructions for setting the control board ACCESSING THE PROGRAMMING BUTTON 1 To access the program button remove the top cover of the bottle filler Remove the two 2 screws holding top cover to bottle filler with a 5 32 allen wrench Remove top cover Do not discard mounting screws they will be needed to reinstall the top cove after programming operations are completed The programming button is located at the top right side of the unit on the control board RESET THE FILTER MONITOR 1 Instructions apply to filtered units only 2 Depress the program button for approximately 2 seconds until the display changes then release The display will change and scroll through two messages RST FLTR Reset Filter Monitor SETTINGS System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle c
7. ERSONA DE SERVICIO AUTORIZADA INSTALACION DE FIJADOR DE SUSPENSION Y DEL PURGADOR 1 Quite el fijador de suspensi n sujetados a la parte posterior del enfriador quitando un 1 tornillo 2 Monte el fijador de suspensi n y quite el purgador como se muestra en la Fig 2 NOTA El fijador de suspensi n DEBE de ser sostenido con se guridad Coloque portadores de soporte de instalaciones fijas si la pared no proveer un soporte adecuado IMPORTANTE Sedebe mantener una dimensi n de 6 1 4 pulgadas 159mm desde la pared hasta la l nea central del purgador para que calce de forma adecuada Ancle el suspensor de forma segura a la pared usando todos los cinco 5 agujeros de montaje de 5 16 de di metro 3 Instale la v lvula directa para el tubo de 3 8 de di metro externo INSTALACI N DEL ENFRIADOR DE AGUA 4 Suspenda el enfriador en el fijador de suspensi n Aseg rese que el fijador de suspensi n calce correctamente en las ranuras de la parte posterior del enfriador como se indica en la figura 3 5 Afloje los dos 2 tornillos que sostienen la parte inferior del panel en la parte inferior de la base del enfriador y los dos 2 tornillos en la parte superior Quite el panel frontal y p ngalo a un lado 6 Conectar el tubo de entrada de agua Ver la Nota 4 en las Instrucciones Generales 7 Quite la tuerca de retenci n y el obturador del purgador y inst lelos en el tubo de desague asegur ndose que la parte fina
8. HVRGRN8WS 1C HVRGRN8WSNF 1C www GreenSpec com MANUAL DEL PROPIETARIO HALSEY TAYLOR Own e rs M d n U a MANUEL DE L UTILISATION HALSEY TAYLOR Hydroboost Bottle Filling Station and Cooler Estaci n de llenado de botella Hydroboost y enfriador Station de remplissage de bouteille Hydroboost et refroidisseur 4 4 V gt Je sm E ZZ a ZE BAA BFA Page 1 1000001739 Rev B 11 14 HVRGRN8WS 1C HVRGRN8WSNF 1C Pictured is unit only without bottle filler Uses HFC 134A refrigerant Usa refrigerante HFC 134A Utilise du fluide frigorig ne HFC 134A See Fig 4 See Fig 3 SSS OS EE 14 F SC 23 i 31 1000001739 Rev B 11 14 30 32 HVRGRN8WS 1C HVRGRN8WSNF 1C YNW NV 134 VadV 1 Y3XIW YNOd 91 2 SNOYIFA SNOAL ay Vd V1V GVOINN V1 YVLIPNS VIVA 91 2 JA SVIYINL SV1 30 SOYIPNOV TIVM OL LINN DNINJISVA 401 SATOH 17109 91 2 ANN 31 13 31NI39N3 1 JA SLN3A3 S91 39 13 NIM ww 71 9 INVOY VIO N3 NOLLVILLN3A 3NNO8 ANN SNOAZJNNSSV OadVd VTA 3183 NW 130 NOIOVIILNAA JA VTMIFIY V 39 1N3 var OH JA NIN ww ZGL 9 3 OIOVdS3 NN OGNAINALNVN VOVNOAGV NOIOVIILLNAA VNA JANODJSV TIVM OL SAJANOT LANIGVD NONA JIINVAVITI NI ww 754 9 ONINIVLNIVIA AS NOLLVTILNSA YIdOYA AUNSNI Sla 3NOI 9313 NOLIVINJMITV O 338 1SVIN3 31 08 VOV 3O9N39IX3 2021419273 OHLSININNS 30 SISANVIV 30 VAIS3938 VIVO INYNOA NON L L NOHd
9. IS x OGVNOIOYOdOdd ON L L Ad AOGVDANd 3 OAHSINANA LON dal p 1 1 9 AVA AILYOS 30 c b a q aq NIVAA 371 NOA JONVAINOIIY LINANADV IO OMLAWYIC JA Z 1 1 JA VNOV aq vql1vS aq 3PVN3Y0 13 VS Vd VAVANJINODJA NOI9V9IaN NIVAQ G O Z V 1411N0 ALSVM 401 NOLLVIOT JAANANMODAU Y ANOV 1d NON AYAIND 4N371nN09 AGNL wug 6 Od 8 Y431d399V YNOd INANOJ NON IJLIHAV JATVA V1 SGNVWWOOSY NVA NA LNINANNOISIAOHddY Q LIONGNA 3 OdV231V 1d ON 34809 30 ONL q O 8 YWLAJDV VHvd OGVIESNWY ON VAVANJD VINATYA VOVANINOIIY VNDV JA OLNJIMIDJLSVAV JA NOI9ISOd 39N 1 Y3IddO9 GALVIdNN OO 8 LdIJIV OL GSHSINYNA LON JAVA AJO LNHS NOLLV2O1 AlddNS YILVM G3dN3IWWOO31 V ee 1 30N3931 VW0N3A371 0N39371 V d V JA OLISINOJN xog JISSJIJA SHIM AlddNS TIV2JIHLIJTI A 1NIWIHINOJY VAV 4131009 VAV SN3dGTIH 9 JO NOILVTIVLSNI YOd Ag LH IJH JDNAJA x LUWYGZ WW Z 40014 GSHSINIS 0l G WUE UUW OS Zl UJUIZGE ZIL Y I were WUZ J ig WWW OF Kick 21 8 S INJNJHINOJH rimi vav 0 Bi LuIEkG WULUQ89 UULUGO BI IZ Lox 91 6 m LHOISH NE V I icll 2 Gap UULUG H UUW 7 N WLS SR dli M JE ue HO q 91 1 6 O LHOIH g K 5 2014140 LL Za 3 g WUUEZE WUO 91 6 Y J UT CS Se ee LUH A Ela MAA NI a SE ER i TA STIOH S IQ UL 91 S gole LIHOVHG UJONVH pPr ITI WIRE YOSNIS OCH WU Y cnt oa NOLLVALLOV BILBI ZIBI E Ki EN STIOH INLINNON 91 2
10. N8WSNF 1C assurer l tanch it LISTA DE PIEZAS DEL FILTRO Vea la Fig 11 FILTER PARTS LIST See Fig 11 Ensamblado del Filtro 3000 Gal n Montaje Cabeza Kit Filtro Incluye John Guest Montaje y 3 8 Codo 55898C 98926C Filter Assy 3000 Gal Kit Filter Head Fitting includes John Guest Fitting amp 3 8 Elbow Fitting Assy Filter amp Bracket includes Fltr Head Mtg Bkt John Guest Ftgs Screws 0000000746 Conjunto del Filtro y Soporte Incluye Filtro Soporte John Guest Guarniciones Tornillos de Montaje de Cabeza COLD CONTROL WATER 115V Wiring Diagram Diagrama de cableado de 115 voltios Sch ma de c blage de 115 volts OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN TUBE TO ATTACH TUBE IS SECURED IN POSITION PUSH IN COLLET TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE Page 9 Fig 12 Superseal Fitting Assembly Supersello Accesorio de Montaje Superseal Montage Assemblage Note Screw the locknut hand tight to seal Nota Apriete la mano de la contratuerca para sellar Remarque Visser la main de l crou de blocage pour LISTE DES PI CES DU FILTRE Voir Fig 11 Ens filtre 3000 Gallon Raccord T te de Filtre Kit Inclut John Guest Montage et 3 8 Rac cord en Coude Assembl e Filtre et Support Inclut Filtre Montage Support John Guest Vis T t 1000001739 Rev B 11 14 HVRGRN8WS 1C HVRGRN8WSNF 1C PARTS LIST LISTA DE
11. O PART NO DESCRIPTION DESCRIPCI N DESCRIPTION 98543C Kit Electrical Package Paquete Kit El ctrico Forfait Kit Electriqueso 98544C Kit IR Sensor Sensor Kit IR Kit Rcepteur IR 98545C Kit Solenoid Valve Replacement Reemplazo de la V lvula de Solenoide Kit Remplacement de la Valve Sol noide Kit 98546C Kit Aerator Replacement Reemplazo Kit Aireador Remplacement du Kit A rateur 98666C Kit Top Cover Replacement Kit Tapa Cubierta Reemplazo Remplacement du Kit Top Couvercle 98549C Kit Hardware 8 Waterway Parts Piezas del Kit De Hardware y Por V a Navegable Pieces Kit Mat riel et Voie Navigable 98669C Kit Filter Mounting Cover SS Cubierta del Filtro de Kit De Montaje SS Couvercle de Filtre Kit Montage SS 98670C Kit Retro Filter Mounting Montaje de Filtro Kit Retro Montage de Retro Kit Filtre 1000001813 Kit Tower Basin Gasket Kit Torre Cuenca Junta Kit Tour Collecteur Halsey Taylor 2222 CAMDEN COURT IMPRESO EN LOS E E U U OAK BROOK IL 60523 IMPRIM AUX U PRINTED IN U S A SSES FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW HALSEYTAYLOR COM PARA PIEZAS DE REEMPLAZO P NGASE EN CONTACTO CON SU DISTRIBUIDOR LOCAL O VISITE NUESTRO SITIO DE WEB WWW HALSEYTAYLOR COM POUR VOUS PROCURER DES PIOCES CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU VISITEZ NOTRE SITE WEB A LADRESSE WWW HALSEYTAYLOR COM 1000001739 Rev B 11 14 Page 10
12. OTTLE COUNT 1 Depress the program button for approximately 2 seconds until the display changes then release The display will change and scroll through two messages RST FLTR Reset Filter Status LED SETTINGS System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG GEI Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count If the button is not pushed again the display will scroll through the four messages above for three cycles and return to run mode 3 When display shows RST BCNT push program button once the display will show current value e g 0033183 4 Once display shows current value push the program button once more to reset back to 0 The display will show BTLCT 0 for approximately 2 seconds and then return to run mode showing 00000000 bottles 5 Testing the bottle counter REFRIG units Place bottle or hand in front of sensor for 9 4 seconds to see bottle counter count 00000001 This is based on filling a 20 oz bottle NON RFRG units Place bottle or hand in front of sensor for 6 25 seconds to see bottle counter count 00000001 This is ba
13. arboteur Mamelon Joint 98776C Kit Condenser Drier Kit Condensador Secador Kit Condensateur D shydrateur 66703C Drier Secador D shydrateur 98777C Kit Compr Mtg Hdwe Grommets Kit Compresor Hardware Arandelas Clips Per Kit Compresseur Mat riel Oeillets Clips Studs nos de Montaje Clips Tiges Filet es de Fixation 98778C Kit Heat Exchanger Drier Kit Intercambiador de Calor Secador Kit Echangeur Thermique D shydrateur 1000001812 Kit Bottle Filler Drain Kit de Drenaje de Llenada de la Botella Kit de Remplissage de Bouteille de Vidange 1000001900 Kit Drain Plate Plug Elbow Nut Kit De Desag e Placa Enchufe Codo Tuerca Kit Plaque Plug Coude crou de Vidange 98773C Kit Cold Control Screws Kit Control del Enfriamiento Tornillo Kit Contr le de Refroidissement Vis 0000000745 Kit Evaporator Assembly Kit Ensamblado del Evaporizador Kit Ens D vaporateur 98750C Kit Capacitor Relay Kit Condensador del Compresor Rel Kit Condensateur de Compresseur OverLoad Cover Sobrecarga Cubierta Vis Relais Surcharge Relais Coiffe 156720 Screw Cap 6 32 Tornillo de fijaci n Vis de blocage 28519C Panel Right Side SS Panel Lado Derecho SS Panneau C t Droit SS 28522C Panel Left Side SS Panel Lado Izquierdo SS Panneau C t Gauche SS 28860C Panel Front Push SS Panel Presi n Frontal SS Panneau Avant SS 28525C Panel Right Rear SS Panel Retrovisor Derecho SS Panneau Arri re Droit SS
14. l del tubo de desague calce en el purgador Ensamble la tuerca de la ranura y el obturador y apriete en forma segura PUESTA EN MARCHA Ver tambi n las Instrucciones Generales 8 Stream height is factory set at 45 50 PSI If 8 La altura del chorro se ajusta en la f brica a 45 50 PSI Si la supply pressure varies greatly from this adjust presi n de suministro var a mucho de esta valor ajustar el tornillo screw using the access hole in the pushbutton usar el agujero de acceso en el bot n El ajuste en sentido insert screwdriver CW adjustment will raise horario elvara el chorro y en sentido contrahorario lo bajara stream and CCW adjustment will lower stream inserte el destornillador Para un ajuste mejor el chorro debe For best adjustment stream should hit basin chocar con el dep sito aproximadamente a 6 1 2 165mm del approximately 6 1 2 165mm from bubbler borboteador 16 Basin Estanque Bassin 1000001739 Rev B 11 14 39 VANDAL RESISTANT BUBBLER DETAIL IMPORTANT TOUT ENTRETIEN DOIT TRE EFFECTU PAR UN REPR SENTANT AUTORIS INSTALLATION DU SIPHON ET DU SUPPORT DE SUSPENSION 1 Retirez le support de suspension l arri re du refroidis seur en enlevant une 1 vis 2 Installez le support et le siphon tel qu indiqu la fig 2 NOTE Le support de suspension DOIT tre bien retenu en place Ajoutez des ferrures de fixation si le mur n offre pas le soutien voulu IMPORTANT e Pour avoir une b
15. le Filler waterline inside of the water cooler by connecting the 3 8 water line to the tee 14 Install filter cartridge remove filter from carton remove protective cap attach filter to filter head by firmly inserting into head and rotating filter clockwise NOTE If existing plumbing rough in locations Drain Water In and Electric Supply do not allow the filter to be mounted inside the cooler cabinet the filter can be installed horizontally below the unit A retrofit kit is available to mount the filter beneath the cooler 15 Turn water supply on and inspect for leaks Fix all leaks before continuing 16 Once unit has been inspected for leaks and any leaks found corrected plug Bottle Filler and unit into wall Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the ON position 17 Once power is applied to Bottle Filler the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter 18 Verify proper dispensing by placing cup hand or any opaque object in front of sensor area and verify water dispenses Note the first initial dispenses might have air in line which may cause a sputter This will be eliminated once all air is purged from the line 19 Once unit tests out install Lower Panel back on water cooler s Units are now ready for use 1000001739 Rev B 11 14 Page 6 HVRGRN8WS 1C HVRGRN8WSNF 1C BF11 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BO
16. le or hand in front of sensor to make sure water is dispensed SETTING UNIT TYPE 1 Depress the program button for approximately 2 seconds until the display changes then release The display will change and scroll through two messages RST FLTR Reset Filter Status LED SETTINGS System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display shows UNIT TYPE push program button once the display will show current value Can be REFRIG or NON RFRG 4 Push button once to change value Once value is selected the display will show the new value Can be REFRIG or NON RFRG REFRIG stands for refrigerated product In this setting the flow rate is estimated at 1 0 gallon per minute NON RFRG stands for nonrefrigerated product In this setting the flow rate is estimated at 1 5 gallons per minute Both REFRIG and NON RFRG simulate 1 bottle equal to 20 oz 5 Allow approximately 4 seconds to pass and the display will return to bottle counter and be in run mode RESETTING B
17. onne position on doit garder une dimension de 6 1 4 po 159mm du mur l axe central du siphon Ancrez solidement le support au mur l aide des five 5 trous de fixation d un diam 5 16 po 3 Installez la soupape droite dans le tuyau de D E 3 8 INSTALLATION DU REFROIDISSEUR 4 Installez le refroidisseur sur les supports en vous as surant que ceux ci sont bien install s dans les fentes l arri re du refroidisseur tel qu indiqu la figure 3 5 D gagez les deux 2 vis retenant le panneau inf rieur avant au bas de la base du refroidisseur ainsi que deux 2 vis sur le dessus Retirez le panneau avant et mettez le de c t 6 Connectez l alimentation en eau Voir note 4 des instructions g n rales 7 Retirez l crou coulissant et le joint du siphon et installez les sur la conduite r siduaire du refroidisseur en vous assurant que le bout de la conduite entre bien dans le siphon Installez l crou coulissant et le joint au siphon et resserrez bien MISE EN MARCHE Voir aussi les Instructions G n rales 8 La pression du jet est r gl e en usine 3 1 et 3 4 bars Si la pression d alimentation varie fortement de cette valeur employer l ouverture d acc s dans le bouton poussoir Un r glage dans le sens des aiguilles d une montre rel ve le jet et un r glage dans le sens contraire l abaisse ins rez le tourn evis Pour un r glage optimum le jet doit frapper le bassin environ 165 mm du barboteur
18. ount and be back in run mode 3 When the display changes to RST FLTR depress the button again The display will change to show FLTR Depress the button again and the display will show FLTR 0 4 The Green LED should be illuminated indicating that the visual filter monitor has been reset SETTING RANGE OF THE IR SENSOR 1 Depress the program button for approximately 2 seconds until the display changes then release The display will change and scroll through two messages RST FLTR Reset Filter Status LED SETTINGS System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display shows RNG SET push program button once the display will show current value can be 1 10 e g RNG 3 4 Once display shows current value push the program button to scroll through value of 1 10 Select the desired range setting 5 Once range is selected allow approximately 4 seconds to pass and then the display will go back to bottle counter and be in run mode 6 Test bottle filler by placing bott
19. sed on filling a 20 oz bottle SETTING FILTER CAPACITY 1 Depress the program button for approximately 2 seconds until the display changes then release The display will change and scroll through two messages RST FLTR Reset Filter Status LED SETTINGS System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG GEI Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count If the button is not pushed again the display will scroll through the four messages above for three cycles and return to run mode 3 When display shows FLT SIZE push program button once The display will show current value Can be 3000GAL or 6000GAL 4 Push program button again to display the desired FLT SIZE 5 Allow approximately 4 seconds to pass and the display will return to bottle counter and be in run mode Page 7 1000001739 Rev B 11 14 HVRGRN8WS 1C HVRGRN8WSNF 1C 22 ME J ONG Fig 9 BOTTLE FILLING UNIT Fig 10 WALL MOUNTING PLATE Page 8 1000001739 Rev B 11 14 HVRGRN8WS 1C HVRGR