1. Install a gate valve or ball valve if required by any codes In instances where the discharge line is exposed to freezing temperatures the pipe must be positioned in a downward slope so any remaining water will drain away Failure to do this will prevent water from exiting the pit and damage the pump if the line freezes a Unplug the pump from the outlet b Loosen the check valve or rubber union by unscrewing the bottom hose clamp If the existing system is installed without a check valve or rubber union saw the pipe apart above the sump pit a S d If the adapter fits into the new pump screw the pipe into the pump If not cut a piece of rigid PVC pipe and connect it to a 1 1 2 PVC adapter by cementing the two pieces together c Remove the old pump and unscrew the pipe and adapter Follow the instructions on the PVC cleaner and cement Then screw the new piece into the pump e Loosen the enclosed stainless steel hose clamp by turning the screw counterclockwise and slip it over the pipe on top of the pump f Hold the float switch against the discharge pipe so the cage is below the bracket g Position the bottom of the float at the height you want the pump to activate and turn the screw clockwise to tighten the hose clamp but do not tighten it completely at this time h Lower the pump into the sump by the handle i To avoid debris pouring into the float it should be positioned on the s
2. for a particular purpose and warranties against hidden or latent defects to the extent permitted by law GLENTRONICS INC will not be liable for any incidental special or consequential damages for breach of any express or implied warranties on this product In so far as such warranties cannot be disclaimed GLENTRONICS INC limits the duration and remedies of such warranties to the duration of this express warranty and AT GLENTRONICS INC s option the repair or replacement services described below Some states countries and provinces do not allow limitations on how long an implied warranty or condition may last so the limitation described above may not apply to you Any and all causes of action arising from filed as a result of or in reference to this warranty or the products described under this warranty shall be governed by and construed under the laws of the State of Illinois Any cause of action arising from filed as a result of or in reference to this warranty or the products described under this warranty shall be filed only in the Circuit Court of the 18th Judicial District Lake County Waukegan Illinois or in the Northern District of Illinois if filed in Federal Court The maximum liability for any product described in this warranty shall be the cost of product replacement only If any term is held to be illegal or unenforceable the legality or enforceability of the remaining terms shall not be affected or impaired What is Covered
3. to the existing plumbing Dual float and controller Stainless steel hose clamp A check valve or rubber union PVC pipe cleaner and cement Wire ties or hose clamps 1 3 HP Pump 1 2 HP Pump The Dual Float BW1033 BW1050 amp Controller NOTICES The Basement Watchdog BW1033 and BW1050 come equipped with a built in air relief valve located on the top of the pump While the pump is active some water may come out of the valve This is normal The valve is needed to prevent an air lock within the pump DO NOT obstruct the air relief valve or an air lock may prevent the pump from activating The control unit must receive 115V AC 5 and 60 Hz from the AC outlet These primary pumps will not provide protection during a power outage With the risk of property damage from high water levels the addition of a Basement Watchdog battery backup sump pump system is highly recommended After the initial installation be sure to check the operation by filling the sump with water and observing the pump operation through one full cycle For continuous duty operation the pump must be submerged at least 3 4 of the depth of the pump at all times In instances where the discharge line is exposed to freezing temperatures the pipe must be sloped downward so any remaining water will drain out Failure to do so will prevent water from exiting the sump and damage the pump if the line freezes Installation Instructions Prior to Installation 1 V
4. Basement Watch dog Important Safety Instructions S u m p u m S SAVE THESE INSTRUCTIONS This manual contains important SAFETY WARNINGS and p p OPERATING INSTRUCTIONS for the Basement Watchdog pumps You will need to refer to it before attempting any installation or maintenance In stru cti 0 n M an ual amp ALWAYS keep these instructions with the unit so that they will be easily accessible Failure to read and follow these warnings and instructions could result in property Safety Wa rni n gs damage serious injury or death Risk of electric shock To reduce this risk observe the A WARNING following precautions e ALWAYS disconnect the pump from the power source before servicing or making adjustments Models BW1033 and BW1050 e NEVER handle the pump or motor with wet hands or when standing on a wet or damp surface while the pump is plugged into the power source e MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE This pump is wired with a 3 prong grounded plug To reduce the risk of electric shock be certain that it is only connected to a properly grounded 3 prong receptacle If you have a 2 prong receptacle have a licensed electrician replace it with a 3 prong receptacle according to local codes and ordinances e NEVER bypass grounding wires or remove the ground prong from the plug e DO NOT use an extension cord The electrical outlet should be within the length of the pump s power cord and at
5. by this Warranty GLENTRONICS INC warrants to the end purchaser that its pumps switch and control unit products are free from defective materials and workmanship for the periods indicated below All parts and labor excluding installation for a period of e 3 years from the date of purchase when used intermittently as a sump pump e 1 year from the date of purchase when used in continuous duty operations such as fountains or ponds The defective product must be returned directly to the factory postage prepaid with the original bill of sale or receipt to the address listed below GLENTRONICS INC at its option will either repair or replace the product and return it postage prepaid What is NOT Covered by this Warranty This warranty does not cover the cost or value of damaged property including expressly any property that has been affected by water overflow seepage or flooding If GLENTRONICS INC determines that a product is deemed defective under this warranty agreement it will repair or replace the PRODUCT ONLY GLENTRONICS INC will not cover the cost to reinstall the product nor will GLENTRONICS INC pay the cost of having a plumber or contractor repair or replace the product GLENTRONICS INC will not repair or replace a product that was installed incorrectly A product shall be considered installed incorrectly when it deviates in any way from the instruc tions described in this manual This warranty does not cover product p
6. ide of the discharge pipe opposite the drain tile Note Itis desirable to mount the float below the drain tile that empties into the pit Mounting it above the drain tile would allow water to fill the drain tile before the pump is activated See diagram j Once the switch is in the desired position tighten the hose clamp k Connect the pipe on the pump to the existing discharge pipe with a rubber union or check valve and tighten the hose clamps securely Connecting the Pump and Controller Make sure the outlet is single phase 115V and 60HZ A WARNING for all the pump installations Dual Float Controller DUAL FLOAT CONTROLLER PLUGGED INTO Plug the control box into a properly AC OUTLET grounded 3 prong receptacle then insert aoe the pump plug into the receptacle on the ae control box For a neater installation secure the power cord and the float switch cord to the discharge pipe with wire ties or hose clamps Keep the cords separated from each other on opposite sides of the pipe DISCHARGE _ PIPE WIRE GATE VALVE UNION CHECK VALVE Completing the Installation 1 After the initial installation be sure to check the pump operation by filling the sump with water and observing the pump through one full cycle The pump should run for 10 seconds after the lower float drops Note When the pump activates some water may come out of the air relief valve located on the top of the pump Th
7. ing make sure a stream of water is escaping from the air relief valve If not clear the hole of any deposits or debris MAIN BATTERY A C PUMP BACKUP PUMP NS DD OF KR W PP Troubleshooting Always unplug the pump from the controller before performing any maintenance The pump will not start or run Clear debris from inside the float cage Loosen nut on top of float then remove c clip on bottom of float Remove debris Tighten nut on top of float then replace c clip on bottom of float When reassembling the float the magnetic strip on the inside of the float should be facing down Defective float switch Replace float switch with new float switch Check valve installed with no air bleed hole in Drill a bleed hole in the discharge pipe or clean debris from the existing hole pipe or pump in the pipe or pump Check valve is stuck or installed upside down Reverse or replace check valve Make sure the check valve is installed with the flow arrow pointing up and out of the pit p g up p a ea a Peh ee eas Replace the check valve on the secondary pump Low power voltage Check valve installed with no air bleed hole in Drill a bleed hole in the discharge pipe or clean debris from the existing hole pipe or pump in the pipe or pump Check valve is stuck or installed upside down Reverse or replace the check valve Be sure check valve is installed with flow arrow pointing up and out of the pit Pump is air locked Remove debris from the ai
8. is is normal The pump should have a normal pumping sound Any abnormal sound vibration or lack of output from the discharge pipe is the signal of a problem Stop the pump and refer to the troubleshooting guide 2 Replace the pit cover making sure not to pinch or crimp the pump wire with the cover The pit cover either has a hole punch that will allow the cord to be passed through or one can be drilled Product Operation Dual Float Switch The dual float switch contains two large floating rings enclosed within a protective cage Water will lift the bottom float by a 14 which will activate the pump If for any reason the lower float does not activate the pump the water will rise and activate the second switch As the pump evacuates the water from the pit the floats will drop The pump will run for an additional 10 seconds to extend the cycle after the lower float drops Note When mounting the float switch position the bottom of the cage at the height you want the pump to activate Dual Float Controller This control box contains a piggyback switch that powers the Basement Watchdog Dual Float The Dual Float Controller will activate the pump when either float is Backup Installation When the power goes out the Basement Watchdog AC sump wine pumps will not operate For PI lifted and then shuts off automatically 10 seconds after the float drops Operating the Pump in a Continuous Duty Application protectio
9. isually inspect your pump Products may be damaged during shipping If the product has been damaged contact your place of purchase or Glentronics Inc before installation Thoroughly read the instructions provided to learn specific details regarding installation and use This manual should be retained for future reference Use a pit that conforms to all local Clean the pit of all debris The pump s The pump should not be set directly The pump should be level Install discharge plumbing according to An in line check valve is recommended If you are replacing an old sump pump 9B codes and is large enough to accommodate the pump and float JOIST switch The minimum requirements for pumps with the double float assembly DLAT are 7 in diameter and 14 deep PLUGGED INTO However larger sump pits are preferred since they will extend the discharge allie a cycle and reduce the number of times GATE the pump turns on VALVE strainer must be kept clear d AE onto a clay earthen or sand base You PUMP may install bricks or blocks under the P pump to provide a solid base jittie local regional and state codes Rigid PVC pipe is recommended BASEMENT WATCHDOG to prevent back flow This check valve PUMP is mandatory when sharing a discharge line with another pump i e a back up pump or a second primary pump TRAINE BRICKS aE
10. least 4 feet above the floor level to minimize potential hazards from flood conditions e DO protect the electrical cord from sharp objects hot surfaces oil and chemicals Avoid kinking the cord e MAKE SURE the supply circuit has a fuse or circuit breaker rated to handle the power requirements noted on the nameplate of the pump To reduce the risk of hazards that can cause injury or A CAUTION property damage observe the following precautions e DO NOT use the power cord or strain relief to carry the pump Use the pump handle e DO NOT expose the control unit to rain or snow e DO NOT operate the pump or control unit if it has been damaged in any way e DO NOT use sump pumps in pits handling raw sewage salt water or hazardous liquids e DO NOT disassemble the pump or control unit When service is required contact Glentronics technical support at 800 991 0466 option 3 Return the product to the manufacturer for any repairs at the following address Glentronics Inc 645 Heathrow Drive Lincolnshire IL 60069 Specifications 1 3 HP Model BW1033 1 2 HP Model BW1050 GPH 0 3600 4400 GPH 10 2600 3200 G Wh 6 2 6 3 Pump diameter 6 2 6 2 Volts 115V 60Hz 115V 60Hz Amps a0 4 2 G Wh Gallons per Watt Hour G Wh GPH Amps x Volts Items Included You may also need Pump Y 1 A 1 1 2 PVC pipe adapter to screw j m into the discharge hole on top of the pump 1 1 2 rigid PVC pipe to connect
11. n during a power outage a Basement Watchdog DFC1 battery backup system can be installed There are three systems with matching batteries that will provide protection The illustration at right is an example of a typical battery backup installation BACKUP SYSTEM DUAL FLOAT CONTROLLER PLUGGED INTI CONTROL UNIT AC OUTLET The Basement Watchdog pumps are rated for continuous duty and may be used in applications requiring continuous pumping including fountains ponds etc For use in any continuous duty application the pump should be plugged directly into the wall outlet without the use of the controller The outlet must be a single phase properly grounded 3 prong receptacle 115V 60HZ For continuous duty operation the pump must be submerged at least 3 4 of the depth of the pump at all times Maintenance Check List Maintenance should be performed 1 2 times per year Remove all debris from the bottom of the pit Vit our website Remove all debris floating in the water www basementwatchdog com wenoa _ fi FLOAT SWITCH Remove all debris from the float switch cage for more information about SWITCH the Basement Watchdog AC sump pumps and battery backup sump pump products Remove all debris around the air relief valve Fill the pit with water Make sure pump turns on at the intended level While the pump is running make sure pump is evacuating water at a good pace While the pump is runn
12. r relief valve Check valve on secondary pump will not close and water re circulates within the system REP ACE Miche er valve ONNE REONE RUMP Blocked intake screen Clear debris from intake screen Broken impeller Replace impeller with new one Consult a licensed electrician If the above solutions do not solve the problem contact Glentronics customer service 800 991 0466 option 3 Thermal protector tripping or not functioning Pump starts and stops too frequently One or both of the floats is obstructed and cannot drop down Pump will not shut off Insufficient or no water volume Abnormal sound or vibration Limited Warranty By opening this package and using this GLENTRONICS INC product you are agreeing to be bound by the terms of the GLENTRONICS INC limited warranty warranty as set out below Do not use your product until you have read the terms of the warranty If you do not agree to the terms of the warranty do not use the product and return it within the return period stated on your purchase receipt from the retail store or authorized distributor where you purchased it for a refund To the extent permitted by law this warranty and the remedies set forth are exclusive and in lieu of all other warranties remedies and conditions whether oral written statutory express or implied GLENTRONICS INC disclaims all statutory and implied warranties including without limitation warranties of merchantability and fitness
13. roblems resulting from handling liquids hotter than 104 degrees Fahrenheit handling inflammable liquids solvents strong chemicals or severe abrasive solutions user abuse misuse neglect improper maintenance commercial or industrial use improper connection or installation damages caused by lightning strikes excessive surges in AC line voltage water damage to the controller other acts of nature or failure to operate in accordance with the enclosed written instructions How to Obtain Warranty Service Within thirty 30 days of the product s defective performance the unit must be shipped freight prepaid or delivered to GLENTRONICS INC to provide the services described hereunder in either its original carton and inserts or a similar package affording an equal degree of protection Products not received by GLENTRONICS INC at the address indicated below within thirty 30 days of the product s defective performance will not be considered for warranty service Products received after the above mentioned timeframe fall outside of the time frame for warranty service and will not be eligible for warranty service The product must be returned to GLENTRONICS INC for inspection in order to be considered for warranty serv ice If the product is not returned to GLENTRONICS INC or the product is inspected by any person plumber contractor or business other than GLENTRONICS INC this warranty shall no longer be valid Prior to defective operation
14. the unit must not have been previously altered repaired or serviced by anyone other than GLENTRONICS INC or its agent the serial number on the unit must not have been altered or removed the unit must not have been subject to accident misuse abuse or operated contrary to the instructions contained in the accompanying manual The dealer s dated bill of sale or installer s invoice must be retained as evidence of the date of purchase and to establish warranty eligibility Where are Products Sent for Warranty Service Glentronics Inc 645 Heathrow Drive Lincolnshire IL 60069 How Can I Obtain More Information By calling 800 991 0466 1806044 02 14 Glentronics Inc 2014