none ISI-0001 Instructions / Assembly
Contents
1. ADDITIONAL HELPFUL MATERIALS Drywall anchors plywood or stud finder to ensure brackets will support the MODEL 1 Level to ensure mounting brackets are level before MODEL 1 is secured with zip ties YOU ARE NOW READY TO BEGIN INSTALLING YOUR HEATWORKS MODEL 1 Please continue to page 3 gt www myheatworks com 3 HEATWORKS MODEL 1 DIAGRAM CONTROL END HEATWORKS RECOMMENDS If your water comes from a well it is recommended you install a sand filter on the main water line entering the house from the well There is also a small filter screen inside the water inlet of the Heatworks MODEL 1 www myheatworks com A CAUTION Breaker must remain off until installation is complete OUTLET TOP INLET BOTTOM 4 INSTALLING THE MOUNTING BRACKETS IMPORTANT The Heatworks MODEL 1 must be oriented horizontally The cold water inlet must be on the bottom of the MODEL 1 and the outlet must be on the top Shown in Heatworks MODEL 1 Diagram page 3 Do not use any other mounting method than the brackets and zip ties provided STEPS 1 Position 2 mounting brackets approximately 6 inches apart and level to support the weight of the MODEL 1 which is approximately 15 pounds when full of water HEATWORKS RECOMMENDS Dry wall anchors are strongly recommended for installation or drill directly into studs Do not attach to drywall without drywall anchors 2 Secure mounting brackets to a flat surface such as a
2. the outlet of each MODEL 1 unit supplies one hot water line 6 A CAUTION Breaker must remain off until installation is complete UNITS INSTALLED IN PARALLEL HEATWORKS MODEL 1 Outlet Hot Water Outlet MODEL 1 M Cold Water Source YOU ARE NOW READY TO PROCEED TO THE ELECTRICAL INSTALLATION Please continue to page 7 gt www myheatworks com 6 ELECTRICAL INSTALLATION SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING The Heatworks MODEL 1 must be installed by a licensed electrician in accordance with all applicable national state provincial and local electrical codes Under no circumstances should the Heatworks MODEL 1 be installed without first shutting off all power to the unit at the fuse or breaker box STEPS 1 Prior to wiring your Heatworks MODEL 1 a licensed electrician should consult the Electrician s White Paper on page 16 2 Verify all wiring wire gauge and circuit protection breakers comply with national and local electrical codes 3 The MODEL 1 requires two power conductors and one grounding conductor a The line conductors can both be phase or one line may be phase and the other neutral split phase installation b Connect the two power and one ground wires to the MODEL 1 www myheatworks com 4 The MODEL 1 auto senses voltage from 110 250 VAC 50 60 Hz No adjustment is needed to set voltage 5 Verify water supply to the Heatwor
3. wall using mounting 4 bracket screws 3 Place the MODEL 1 on the brackets Check the position and orientation to ensure the unit is level with the inlet on the bottom and the outlet on the top 4 Thread 2 cable ties through the brackets around the MODEL 1 4 A CAUTION Breaker must remain off until installation is complete YOU ARE NOW READY TO PROCEED TO PLUMBING INSTALLATION Please continue to page 5 gt www myheatworks com 5 PLUMBING INSTALLATION Follow all plumbing instructions carefully This product MUST be installed by a licensed plumber in accordance with all applicable national state provincial and local plumbing codes STEPS 1 Flush the existing water lines to eliminate all plumbing or plastic paste or residue caused by any previous brazing or soldering 2 Turn off the main water supply 3 Connect the hot water line to the MODEL 1 outlet marked outlet located on the top of the unit HEATWORKS RECOMMENDS Use flexible water heater hoses and push fit fittings for ease of installation OULET TOP 1777 4 Connect the cold water supply line to the MODEL 1 inlet marked inlet on the bottom of the unit HEATWORKS RECOMMENDS Install a manual shut off valve ball valve on the inlet side of the Heatworks MODEL 1 to provide a convenient shut off point INLET BOTTOM 1 2 3 BEFORE PUSH FIT INSTALLED PUSH FIT FITTING FITTING PUSH FIT FITTING q E 5 Turn on the
4. 30 10 10 40 8 8 50 6 8 ISI Technology March 2015 www myheatworks com 8 MODEL 1 SPECIFICATIONS Description Domestic Hot Water Application Power Input Voltage Temperature Control Water Conductivity Temperature Rise at 12kW www myheatworks com Electric tankless water heater that uses direct energy transfer technology to heat water The MODEL 1 provides reliable controllable and immediate hot water either as a standalone water heater or in conjunction with your existing water heater Point of use and or whole house water heating More than one unit may be required for your application Multiple units must be mounted in parallel either distributed or colocated Be sure to check with your licensed electrician to confirm your electrical system can support the required load Maximum current draw is user selectable in 5 amp increments from 15 48 amps Maximum power output can range from 1 65 12kW dependent on input voltage Single split phase operation from 110 250 VAC 50 60 Hz and 15 48 Temperature Outlet Setpoint Range Temperature Setpoint Adjustment Water Connections Operating Pressure Dimensions Weight Certification 50 F to 120 F domestic hot water use 10 C to 49 C domestic hot water use Digital user interface 1 F C adjustment 34 inch or 22 millimeter push fit fittings Maximum 100 psi 12 5 long by 6 5 in diameter 10 5 Ibs approxi
5. Crossed wires SOLUTION Make sure the breakers at the main electrical panel are ON Ensure the MODEL 1 is wired properly in accordance to your licensed electrician Verify the breaker is not faulty First try resetting the breaker by turning it off then back on If this does not fix the problem call us for technical support Increase the temperature setting of the unit See NORMAL OPERATION instructions on page 10 Depending on your incoming water temperature and power output of your MODEL 1 your water flow rate may exceed the heating capacity of your MODEL 1 Reduce the flow rate at the faucet If it is a new installation have your licensed electrician double check the wiring It is possible the wiring is incorrect www myheatworks com 10 HEATWORKS MODEL 1 LIMITED WARRANTY A WARNING Always turn off the power circuit breakers at BOTH the main electrical panel or subpanel High voltage is present in the system Personal injury or death can result if caution is not taken A WARNING NEVER turn power on if there is a possibility the water in the heater is frozen Subject to the terms and conditions set forth in this limited warranty each Heatworks MODEL 1 is warranted to the original Owner Owner against i mechanical or electrical failure of any component solely due to defects in material or Manufacturer s workmanship for a period of twelve 12 years from the date of original purchase and ii leaks du
6. Salida de agua caliente HEATWORKS MODEL 1 Entrada Demanda de agua fr a AHORA USTED EST LISTO PARA PROSEGUIR CON LA INSTALACI N EL CTRICA Por favor contin e a la p gina 7 gt www myheatworks com apagada hasta que la instalaci n est completa 6 INSTALACI N EL CTRICA NEGLIGENCIA A ESTE PASO PODR A RESULTAR EN LESIONES PERSONALES LA MUERTE O DA OS MATERIALES A SU PRODUCTO El Heatworks MODEL 1 debe ser instalado por un el ctrico calificado de acuerdo con todos los c digos nacionales estatales provinciales y locales de electricidad aplicables Bajo ninguna circunstancia el Heatworks MODEL 1 debe ser instalado sin previamente asegurarse de que toda corriente el ctrica este desconectada de la caja de circuitos y fusibles PASOS 1 Antes de instalar su Heatworks MODEL 1 un el ctrico calificado debe consultar el Electrical Whitepaper en la p gina 16 2 Verifique que todo el cableado calibrado de cable y protectores de circuitos interruptores cumplan con los c digos el ctricos nacionales y locales 3 El MODEL 1 requiere dos conductores de alimentaci n el ctrica y un conductor a tierra a Los conductores de l nea pueden ser ambos de fase o una l nea puede ser de fase y la otra neutral Instalaci n de fase dividida b b Conecte los dos conductores de alimentaci n el ctrica y el conductor a tierra hacia el MODEL 1 www myheatworks com 4 El MODEL 1 tiene
7. capacidades de calentamiento de su MODEL 1 Reduzca la velocidad del flujo desde la llave de agua Si es una nueva instalaci n pida a su electricista que revise de nuevo el cableado Es posible que el cableado est incorrecto www myheatworks com 10 HEATWORKS MODEL 1 GARANT A LIMITADA A PRECAUCI N Siempre apague los interruptores de potencia TANTO el panel el ctrico principal subpanel Alto voltaje se presenta en el sistema Lesiones personales o la muerte pueden resultar si no se toman las precauciones debidas A PRECAUCI N NUNCA encienda el MODEL 1 si hay alguna posibilidad de que el agua en el calentador est congelada Sujeto a los t rminos y condiciones establecidos en esta garant a limitada cada Heatworks MODEL 1 garantiza al Propietario original Propietario contra i alg n fallo mec nico o el ctrico de cualquier componente exclusivamente debido a defectos en los materiales o de fabricaci n mano de obra por un per odo de doce 12 a os desde la fecha original de compra y ii fugas de agua debido a defectos en los materiales o de fabricaci n mano de obra por un per odo de doce 12 a os desde la fecha original de compra Si el Propietario no puede documentar la fecha original de compra con el recibo original de compra entonces el per odo de garant a limitada comienza en la fecha que el Heatworks MODEL 1 fue fabricado Por remedio nico y exclusivo de Propietario el Fabricante debe s
8. de agua Heatworks MODELO 1 Sin embargo en algunas viviendas existentes el panel el ctrico principal puede estar casi lleno con interruptores autom ticos que sirven de carga existente En estos casos uno o m s paneles secundarios cada uno con un nico gran interruptor nominal para toda la carga del calentador de agua se pueden instalar fuera del panel principal Las cajas para un subpanel de 50 o 60 amperios se pueden comprar por alrededor de 15 cada uno y el interruptor de alrededor de 12 Cajas e interruptores m s peque os son un poco m s econ micos 30 A PRECAUCI N La caja de circuitos debe estar totalmente CIRCUITOS DERIVADOS E INTERRUPTORES Como aparato de calefacci n no continuo los cables del circuito derivados e interruptores deben tener el tama o de al menos el 100 del valor nominal m ximo de amperios del aparato Esto es particularmente importante para evitar el sobrecalentamiento de los cables en las conexiones a los interruptores El sobre calentamiento en las conexiones del interruptor puede causar molestia o conexiones prematuras al interruptor Se recomienda que el cable para los circuitos derivados y los sub feeds est n clasificados para al menos 75 grados C Si utiliza THHN que est clasificado para 90C el calibre del cable es menor que el alambre 75C est ndar y la cubierta de nylon hace mucho m s f cil para maniobrar El costo de ambos cables es similar Consumo de Calibre Calibre
9. del MODEL 1 O Nivel para asegurar que los Soportes de Montaje est n a nivel antes de que el MODEL 1 sea asegurado con las Cinchas Pl sticas AHORA USTED EST LISTO PARA EMPEZAR LA INSTALACI N DE SU CALENTADOR HEATWORKS MODEL 1 Por favor contin e a la p gina 3 gt www myheatworks com apagada hasta que la instalaci n est completa 3 DIAGRAMA DEL HEATWORKS MODEL 1 SALIDA ARRIBA PANEL DE CONTROL ENTRADA ABAJO HEATWORKS RECOMIENDA Si el agua proviene de un pozo se recomienda instalar un filtro de arena conectado a la l nea de agua principal de entrada a la casa desde el pozo Tambi n hay una peque a pantalla de filtro dentro de la entrada de agua del calentador Heatworks MODEL 1 www myheatworks com A PRECAUCI N La caja de circuitos debe estar totalmente 21 apagada hasta que la instalaci n est completa 4 INSTALACI N DE SOPORTES DE MONTAJE IMPORTANTE El calentador Heatworks MODEL 1 debe estar posicionado horizontalmente La entrada de agua fr a debe estar en la parte inferior del MODEL 1 y la salida por la parte superior C mo se muestra en el Diagrama Heatworks MODEL 1 p gina 3 No utilice ning n otro m todo de montaje m s que los Soportes de Montaje y las Cinchas Pl sticas proporcionadas PASOS 1 Posici n 2 Soportes de Montaje deben estar a aproximadamente 6 pulgadas de distancia y a nivel para soportar el peso del calentador MODEL 1 que es aproximadame
10. localizada en la parte superior de la unidad HEATWORKS RECOMIENDA El uso de Mangueras de conexi n flexibles para calentador y conectores de ajuste S il facil push fit SALIDA ARRIBA 4 Conecte la l nea de agua fr a en la entrada en el MODEL 1 se alizada como inlet localizada en la parte inferior de la unidad HEATWORKS RECOMMENDS Instale una v lvula manual de apague v lvula de bola por el lado de la entrada del calentador Heatworks MODEL 1 para proveer un punto de apague conveniente INLET BOTTOM 1 2 3 ANTES DE INTALAR AJUSTE DE CONECTORE DE LOS CONECTORES CONECTORES AJUSTE PUSH FIT PUSH FIT PUSH FIT DESPUES DE L INSTALACION or E PRECAUCI N Serios da os le podr an ocurrir a su Heatworks MODEL 1 si se suelda cualquier tuber a a las conexiones de entrada y salida de agua Dicho da o NO est cubierto por la garant a 5 Abra la llave del agua principal 1 2 3 6 Purgue el aire de las tuber as de agua y del MODELO 1 ANTES DE INTALAR AJUSTE DE CONECTORE DE abriendo una fuente de demanda de agua caliente grifo LOS CONECTORES CONECTORES AJUSTE PUSH FIT de agua caliente ducha Deje correr el agua por el JOTI DESPUES DEL calentador por lo menos de 2 a3 minutos El agua del INSTALACION ae grifo no estara caliente en este momento www myheatworks com A PRECAUCI N La caja de circuitos debe estar totalmente 23 apagada hasta que la instalaci n
11. main water supply 6 Purge all air from the water lines and MODEL 1 by opening a hot water demand source hot faucet shower etc Allow water to run though the water heater for at least 2 to 3 minutes Water from faucet will not be hot at 3 this point BEFORE PUSH FIT INSTALLED PUSH FIT FITTING FITTING PUSH FIT FITTING www myheatworks com A CAUTION Breaker must remain off until installation is complete 5 CAUTION Serious damage to your Heatworks MODEL 1 can occur if all air is not purged from the water lines and MODEL 1 any time air might be introduced into your home water system 7 Carefully inspect all connections and unions for leaks HEATWORKS RECOMMENDS Since this product does not use a storage tank the use of a temperature pressure relief valve T amp P is not required for most installations However a T amp P valve may be required to meet plumbing codes in your area CAUTION The maximum recommended operating water pressure for the Heatworks MODEL 1 is 100 PSI Consult your licensed plumber for specific information regarding your water pressure INSTALLING UNITS IN PARALLEL When installing multiple MODEL 1 units in the same location with the purpose of having them support the same hot water demand please refer to the diagram to the right In this installation configuration the cold water supply line is split into two dedicated water lines one line for each MODEL 1 unit The hot water lines then converge so
12. n enviados por transporte terrestre Si usted requiere un env o r pido o seguro de transporte estos se pueden proporcionar a un costo adicional A PRECAUCI N La caja de circuitos debe estar totalmente 35 apagada hasta que la instalaci n est completa HEATWORKS MODEL 1 POWERED BY ISI TECHNOLOGY 9 475 East Bay Street Charleston SC 29403 888 506 2821 info isitechnology com www myheatworks com
13. o m s calentadores Heatworks MODEL 1s caben en la mayor a de hogares que tengan 150 o 200 amperios en el servicio el ctrico para toda la vivienda o puede ser instalado utilizando uno o m s sub paneles con un interruptor que tenga el tama o adecuado MODULACI N POTENCIA VOLTAJE Durante la operaci n el Heatworks MODEL 1 est dise ado para utilizar solamente la potencia de energ a necesaria para calendar el agua en diversas combinaciones de temperatura y flujo caudal DESCONECTAR Y SUB PANELS Dispositivos de desconexi n el ctrica no contienen disyuntores ni est n obligados por el C dico El ctrico Nacional NEC para los aparatos recidenciales como el calentador de agua Heatworks MODEL 1 o cualquier aparato el ctrico nominal inferiora 300 voltios Sin embargo las desconexiones pueden ser requeridas por el NEC para cargas de motor y para aparatos con m ltiples circuitos en aplicaciones comerciales A PRECAUCI N La caja de circuitos debe estar totalmente 29 apagada hasta que la instalaci n est completa Sub panels el ctricos que contienen interruptores de circuito se pueden usar con aparatos como el calentador de agua Heatworks MODEL 1 en casas residenciales y comerciales En viviendas nuevas y en algunas construcciones residenciales existentes en general hay suficientes plazas de interruptor en el panel el ctrico principal para acomodar varios interruptores autom ticos adicionales para el calentador
14. HRENHEIT Y CELSIUS PASOS 1 Presione el bot n superior para incrementar los ajustes de temperatura Presione el bot n inferior para reducir los ajustes de temperatura Arriba Salida Entrada Abajo 28 A PRECAUCI N La caja de circuitos debe estar totalmente 2 Seleccione la temperatura entre 50 F 4 C y 130 F 54 C 3 Verifique que la temperatura deseada sea mostrada en la pantalla digital HEATWORKS RECOMIENDA Debido a que los nuevos modelos de lavaplatos est n generalmente equipados con un calentador interno y la mayor a de detergentes de lavander a son intencionados para el uso de agua fr a o tibia no hay necesidad de ajustar la temperatura a m s de 130 grados F PASOS 1 Presione ambos botones simult neamente y suelte el bot n inferior para C 2 Presione ambos botones simult neamente y suelte el bot n superior para F FELICITACIONES USTED HA COMPLETADO LA INSTALACI N DE SU HEATWORKS MODEL 1 www myheatworks com apagada hasta que la instalaci n est completa 7 DOCUMENTACION TECNICA SERVICIO ELECTRICO El calentador Heatworks MODEL 1 sin tanque es considerado un electrodom stico de calefacci n no continuo de acuerdo a las definiciones contenidas en el C digo El ctrico Nacional Un electrodom stico que su carga no es continua durante tres 3 horas o m s es considerado no continuo Por lo tanto el calentador MODEL 1 cuando se utiliza para aplicaci
15. Por favor contacte al Fabricante antes de usar el MODEL 1 en cualquier escenario alternativo para as no anular la garant a REGISTRO DE LA GARANT A Para activar su garant a usted debe registrar su unidad Si usted no activa la garant a el MODEL 1 ser cubierto desde la fecha en que fue fabricado Para registrar la garant a se puede acceder mediante el siguiente enlace http tinyurl com n9y8cst www myheatworks com 11 PROCESO DE DEVOLUCI N Sujeto a los t rminos y condiciones establecidos en la garant a limitada que se encuentran en la p gina 15 si el Heatworks MODEL 1 falla o pierde agua debido a defectos en los materiales o por defectos de mano del fabricante durante el per odo aplicable de la garant a el propietario deber a de contactar al fabricante para una Autorizaci n de Devoluci n de Mercanc a RMA por sus siglas en ingl s No se aceptar n devoluciones por el Fabricante sin un n mero de RMA y el Fabricante no asume ninguna responsabilidad por alg n calentador de agua que sea devuelto sin un n mero RMA Los calentadores de agua deben ser empacados de manera segura para evitar da os durante el transporte El propietario ser el responsable por los gastos de env o de la unidad requerida por Propietario a Fabricante as como tambi n cualquier otro gasto de reinstalaci n Todos los env os de el Heatworks MODEL 1 del Fabricante hacia el Propietario para reemplazar a una unidad defectuosa ser
16. aci n del MODEL 1 Vea el diagrama de anterior 5 Suelte SOLO el bot n superior 6 Mientras sigue presionando solo el bot n inferior presione y suelte el bot n superior cinco veces hasta que el n mero 5 aparezca La pantalla comenzar a parpadear IMPORTANTE Si accidentalmente el bot n superior es presionado m s de 5 veces presione y suelte ambos botones para comenzar de nuevo 7 Suelte ambos botones www myheatworks com apagada hasta que la instalaci n est completa 8 En la pantalla aparecera 15 amperios 9 Presione el bot n superior e inferior para seleccionar su amperaje m ximo deseado El amperaje puede ser seleccionado en incrementos de 5 amperios entre un rango de 15 48 amperios 10 Presione y suelte ambos botones simult neamente para grabar su nuevo ajuste 11 Ahora la pantalla digital mostrar la temperatura ajustada de f brica 115 O Fahrenheit AHORA USTED EST LISTO PARA AJUSTAR LA TEMPERATURA Por favor contin e a la p gina 10 gt www myheatworks com dq PRECAUCI N La caja de circuitos debe estar totalmente apagada hasta que la instalaci n est completa AJUSTES DE TEMPERATURA Despu s de que el MODEL 1 haya sido propiamente instalado y est recibiendo corriente el ctrica la pantalla digital mostrara la temperatura actual del agua El promedio de temperatura para una ducha es entre 104 y 110 grados F 40 a 43 grados C CAMBIAR ENTRE FA
17. adequate protection from the elements 3 The unit is installed in an orientation other than specified in the Installation and User Manual 4 The unit is used with any liquids other than potable water 5 More than 10 glycol is used with a radiant heating application 6 The unit is used with any unapproved chemicals Please contact Manufacturer before using any chemicals in your MODEL 1 so not to void your warranty www myheatworks com 7 Components accessories not compatible with or not intend for the unit are used with the MODEL 1 8 This unit is used in an unapproved scenario such as but not limited to as fish tank water heater to heat pools or spas with a non compatible AC DC converter if under sized for the intended application etc Please contact Manufacturer before using the MODEL 1 in any alternative scenarios so not to void your warranty 9 The inlet outlet is connected to any tap or fitting other than those specified WARRANTY REGISTRATION In order to activate your warranty you must register your unit If you do not activate your warranty your MODEL 1 will be covered from the date it was manufactured Warranty registration can be accessed using the following link http tinyurl com n9y8cst www myheatworks com 11 RETURN PROCESS Subject to the terms and conditions set forth in the limited warranty found on page 15 if the Heatworks MODEL 1 fails or leaks because of defects in materials or Manufacture
18. alaci n de su MODEL 1 siguiendo los pasos en secuencia de c mo son presentados Alo largo de este manual hemos destacado algunos puntos que requieren de atenci n especial Estos puntos est n indicadas en las tres l neas siguientes IMPORTANTE Indica un error com n en la Instalaci n PRECAUCI N Negligencia a este paso podr a resultar en da os materiales a su MODEL 1 o lesiones personales HEATWORKS RECOMIENDA Notas y Beneficios adicionales que el equipo Heatworks y Jerry recomiendan al instalador prestar especial atenci n MODEL 1 INCLUIDO EN LA CAJA O 1 Heatworks MODEL 1 Calentador O 1 Heatworks MODEL 1 Manual de Uso e Instalaci n O 2 Soportes de Montaje O 4 Tornillos para los Soportes de Montaje O 2 Cinchas Pl sticas para sujetar 20 A PRECAUCI N La caja de circuitos debe estar totalmente HERRAMIENTAS NECESARIAS PARA LA INSTALACI N Circuito designado 110 250V 15 48A instalado por un el ctrico capacitado v Proporcionar suministros de agua usando 34 o 22mm con conectores de ajuste suave push fit O Superficie plana i e pared NO INSTALE EL MODEL 1 EN TUBER AS RECOMENDADO PARA LA INSTALACI N O Mangueras flexibles de conexi n para calentador MATERIALES TILES ADICIONALES O Usar anclas de tornillos para paredes de yeso o para Contrachapada de Madera utilizar un localizador de pernos para asegurar los Soportes de Montaje
19. ater to a temperature above 120 F STEPS 1 Press both buttons at the same time and release the bottom button for C 2 Press both buttons at the same time and release the top button for F CONGRATULATIONS YOU HAVE COMPLETED THE INSTALLATION OF THE HEATWORKS MODEL 1 www myheatworks com 7 ELECTRICIAN S WHITE PAPER ELECTRICAL SERVICE The Heatworks MODEL 1 tankless water heater is considered a non continuous heating appliance according to the Definitions in the National Electric Code An appliance load that is not continuous for 3 hours or more is considered non continuous Therefore the MODEL 1 heater when used for standard domestic hot water applications is considered a non continuous heating appliance Due to the diversity of water heating in a home the load amps contribution of the MODEL 1 heater to the overall service load of the home or building can be calculated using the optional methods of National Electrical Code sections NEC 220 82 or 220 83 For new dwellings the service load should be calculated using NEC 220 82 For existing dwellings the service load should be calculated using NEC 220 83 By both calculation methods the Heatworks MODEL 1 load is generally added to the service load at 40 of it s maximum nameplate rating For instance the maximum current amp rating of the Heatworks MODEL 1 is 48 amps and 40 of this rating is about 20 amps The 20 amps is typically the load added t
20. ccordance with all national state provincial and local electrical and plumbing codes This Heatworks MODEL 1 was tested before leaving the factory As a result there may be a small amount of residual water in the MODEL 1 A CAUTION Breaker must remain off until installation is complete 1 2 HOW TO USE THIS MANUAL Please proceed with installation of your MODEL 1 by following the steps in the sequence they are presented Throughout this manual we have highlighted certain points that require special attention These points are indicated by the three BOLDED categories below IMPORTANT Commonly missed step in installation CAUTION Negligence of this step could result in damage to your MODEL 1 or personal injury HEATWORKS RECOMMENDS The user or installer should be aware of these additional notes and benefits INCLUDED IN THE BOX O 1 Heatworks MODEL 1 water heater O 1 Heatworks MODEL 1 Installation and User Manual O 2 Mounting Brackets O 4 Mounting Bracket Screws O 2Zip Ties O 1 Showerhead Our Gift to You 2 A CAUTION Breaker must remain off until installation is complete REQUIRED FOR INSTALLATION Designated 110 250 volts 15 48 amp circuit installed by a licensed electrician O Water supply using 34 or 22mm push fit connectors O Flat mounting surface ie a wall DO NOT SECURE THE MODEL 1 TO PIPING RECOMMENDED FOR INSTALLATION Flexible water heater connection hoses
21. corriente del cable del cable amps 75C 90C THHN 15 14 14 20 12 12 30 10 10 40 8 8 50 6 8 ISI Technology Marzo 2015 www myheatworks com apagada hasta que la instalaci n est completa 8 MODEL 1 SPECIFICATIONS Descripci n Aplicaci n de agua Caliente Dom stica Poder Voltaje de Entrada Control de temperatura Conductividad de Agua Incremento de temperatura a 12kW www myheatworks com Calentador de agua el ctrico sin tanque que utiliza tecnologia de transferencia de energia directa para calentar agua El MODEL 1 proporciona agua caliente fiable controlable e inmediata ya sea como un calentador de agua independiente o en conjunto con su calentador de agua existente Punto de uso y o calentamiento el agua de toda la casa M s de una unidad pueden ser requeridos para su aplicaci n M ltiples unidades deben ser Instaladas distribuidos o colocados paralelamente Aseg rese de consultar con su electricista para confirmar que su sistema el ctrico pueda soportar la carga Consumo m ximo de corriente es seleccionable en incrementos de 5 amp entre 15 48 amps Potencia m xima de salida est entre 1 65 12kW dependiendo en el voltaje de entrada Operaci n nico fase dividida desde 110 250 VAC 50 60 Hz y 15 48A Microprocesador termost tico de control de temperatura Ajusta la temperatura 60 veces por segundo La fuente de agua debe estar entre 150 a 1500 us de conduc
22. de of the published specification for the heater is exposed to any condition that causes the heater to turn on before the air is purged from the heater or f The water heater has been exposed to conditions resulting from floods earthquakes winds fire freezing lightning or circumstances beyond the Manufacturer s control or g The water heater s outer wrapper sticker has been broken or tampered with or h The water heater has been used for other than the intended purpose ie use with liquids other than potable water or i The water heater has been tampered with either electronics or software or 16 A CAUTION Breaker must remain off until installation is complete j If there is any disassembling of any components other than the wire connectors and end plates or k The water heater is subjected to applications of DC voltage or The water heater is operated without inlet filter screen located inside the water inlet or m The water heater installation exposes the unit to the elements or n The workmanship of any installer or o The spray head is not regularly descaled 3 Owner and not Manufacturer or its agent representative is liable for and shall pay for all field charges for labor or other expenses incurred in the removal or any NON COVERED WARRANTY expense incurred by Owner LIMITED WARRANTY VOIDED IF 1 The unit is tampered with or self serviced in anyway 2 The unit is installed outdoors without
23. detecci n autom tica de voltaje entre 110 250 VAC 50 60 Hz No se necesitan ajustes para ajustar el voltaje 5 Verifique que el suministro de agua hacia el Heatworks MODEL 1 este encendido y que haya sido purgado el aire en el MODEL 1 PRECAUCI N Serios da os pueden ocurrir a su Heatworks MODEL 1 si todo el aire no es purgado de las tuber as de agua y del MODEL 1 en cualquier momento el aire puede ser introducido en su sistema de agua casero AHORA USTED EST LISTO PARA AJUSTAR EL AMPERAJE M XIMO Por favor contin e a la p gina 8 gt A PRECAUCI N La caja de circuitos debe estar totalmente 25 apagada hasta que la instalaci n est completa AJUSTES DE AMPERAJE IMPORTANTE El amperaje predeterminado de fabrica es de 15 Amperios Para maximizar la cantidad del aumento de temperatura asegurese de ajustar su amperaje deseado a sus necesidades especificas de agua caliente Tambi n aseg rese de que su MODEL 1 haya sido instalado y cableado de acuerdo con los requisitos de amperaje programados PANEL DE CONTROL Arriba Salida Botones de control Entrada Abajo 26 A PRECAUCI N La caja de circuitos debe estar totalmente PASOS 1 Encienda cualquier llave de agua caliente 2 Deje el agua correr por 1 minuto El agua no estar caliente 3 Encienda el MODEL 1 activando el circuito o fusible asociado 4 Mantenga presionados los dos botones localizados al lado de la pantalla de visualiz
24. e both buttons www myheatworks com 8 The display will now read 15 amps 9 Press the up and down buttons to select your desired maximum amperage Amperage can be selected in 5 amp increments from 15 48 amps 10 Press and release both buttons simultaneously to save the new setting 11 Digital display will now read the default temperature setting of 115 F YOU ARE NOW READY TO ADJUST THE TEMPERATURE Please continue to page 10 gt www myheatworks com A CAUTION Breaker must remain off until installation is complete ADJUSTING THE TEMPERATURE After the MODEL 1 has been properly installed and is receiving power the digital display will show the current water temperature setting The average shower temperature is between 104 and 110 F 40 and 43 C SWITCHING BETWEEN FAHRENHEIT AND CELSIUS STEPS 1 Press the top button to increase the temperature setting Press the bottom button to decrease the temperature setting Outlet Top Inlet Bottom 10 A CAUTION Breaker must remain off until installation is complete 2 Select temperature between 50 F 4 C and 120 F 49 C 3 Verify your desired temperature appears on the digital display HEATWORKS RECOMMENDS Because newer model dish washers are typically equipped with an internal heating element and most laundry detergents are intended for use in cold or warm water there is no longer a need to set your water he
25. e la Garant a 11 Proceso de Devoluci n 35 A PRECAUCI N La caja de circuitos debe estar totalmente www myheatworks com apagada hasta que la instalaci n est completa nf ANTES DE LA INSTALACI N LEA COMPLETAMENTE ESTAS INSTRUCCIONES NO HACERLO PUEDE RESULTAR EN DA OS MATERIALES LESIONES SERIAS O LA MUERTE INSTALACI N INAPROPIADA O EL MAL USO ANULAN LA GARANT A Visita nuestro sitio web 4 www myheatworks com para obtener la ltima versi n del Manual de Usuario e Instalaci n HEATWORKS MODEL 1 www myheatworks com 1 INFORMACION IMPORTANTE DE SEGURIDAD APAGUE LA CAJA DE CIRCUITOS Y LA LLAVE DE AGUA ANTES DE EMPEZAR LA INSTALACI N LESI NES GRAVES O LA MUERTE PUEDE OCURRIR SI SE IGNORA ESTA ADVERTENCIA Apague cualquier fuente el ctrica conectada directamente a la caja de circuitos antes de instalar o inspeccionar su calentador Heatworks MODEL 1 El calentador Heatworks MODEL 1 debe ser instalado por un el ctrico y un plomero capacitados de acuerdo a todos los c digos nacionales estatales provinciales y locales de electricidad y plomer a Este calentador Heatworks MODEL 1 fue probado antes de salir de la f brica Como resultado podr a haber una peque a cantidad residual de agual en el MODEL 1 A PRECAUCI N La caja de circuitos debe estar totalmente 19 apagada hasta que la instalaci n est completa 2 COMO USAR ESTE MANUAL Por favor proceda con la inst
26. e to defects in material or Manufacturer s workmanship for twelve 12 years from the date of original purchase If Owner cannot document the original date of purchase with original sales receipt then the limited warranty period begins on the date the Heatworks MODEL 1 was manufactured As Owner s sole and exclusive remedy Manufacturer shall replace the Heatworks MODEL 1 Manufacturer is not liable for any costs incurred by Owner including without limitations the cost of any labor or material costs for removal repair and or reinstallation Manufacturer s maximum liability is limited to the value of the water heater This limited warranty shall be governed by the laws of the United States www myheatworks com The remedy set forth in this limited liability warranty is the only remedy available to Owner or any person for breach of any covenant duty or obligation on the part of the Manufacturer Manufacturer is not liable to Owner or any third party for any loss personal injury or property damage directly or indirectly arising from the Heatworks MODEL 1 water heater Under no circumstances is Manufacturer liable to Owner or any third party for incidental conseguential special contingent or punitive damages of any description whether any such claim be based upon warranty contract negligence strict liability or other tort or otherwise Some states do not allow the exclusion or limitations of incidental or conseguential dama
27. est completa PRECAUCI N Serios da os pueden ocurrir a su Heatworks MODEL 1 si todo el aire no es purgado de las tuber as de agua y del MODEL 1 en cualquier momento el aire podr a ser introducido en su sistema de agua casero 7 Cuidadosamente inspeccione todas las conexiones y uniones para prevenir fugas HEATWORKS RECOMIENDA Dado a que este producto no utiliza un tanque de almacenamiento no se requiere el uso de una v lvula de alivio de presi n de temperatura T amp P para la mayor a de las instalaciones Sin embargo una v lvula T amp P podr a ser necesaria para cumplir de acuerdo a los c digos de plomer a en su zona PRECAUCI N La recomendaci n m xima de presi n de agua al operar el calentador Heatworks MODEL 1 es 100 PSI Consulte con su plomero calificado para m s informaci n acerca de su presi n de agua INSTALACI N DE UNIDAD PARALELA Cuando se instalen m ltiples calentadores MODEL 1s en el mismo sitio con prop sito de hacerlos soportar la misma demanda de agua favor consulte el siguiente diagrama Esta instalaci n requiere que la l nea de suministro de agua fr a se divida en una l nea por cada MODEL 1 y las l neas de agua caliente se converjan de manera que la salida de cada MODEL 1 sea instalado en la misma l nea de agua caliente 24 A PRECAUCI N La caja de circuitos debe estar totalmente UNIDADES INSTALADAS EN PARALELO HEATWORKS MODEL 1 Entrada Salida
28. ges so the limitations or exclusion may not apply to Owner In such cases the warranty shall be limited to twelve 12 years from the original date of purchase or date manufactured as provided in this limited warranty or the shortest period allowed by law This warranty gives Owner specific legal rights and Owner may also have other rights which may vary from state to state Exclusions of Coverage from this Limited Warranty 1 Manufacturer is not liable for any water damage or other damages arising directly or indirectly from any defect in the Heatworks MODEL 1 tankless Water Heater component part s or from its use 2 Manufacturer is not liable under this limited warranty or otherwise if A CAUTION Breaker must remain off until installation is complete 15 a The water heater or any of its component parts have been subject to misuse alteration neglect impact or accident or b The water heater has not been installed in accordance with the applicable local plumbing and or building code s and or regulation s or c The water heater has not been installed or maintained in accordance with Manufacturer s instructions or has been installed with improper orientation improper fastening improper use of pipe dope plumbers putty or with the use of any sealant or d The water heater has sediment inside the unit or e The water heater experiences any water pressure or flow interruptions ie normal inlet water pressure is outsi
29. ks MODEL 1 is turned on and MODEL 1 has been purged of air CAUTION Serious damage to your Heatworks MODEL 1 can occur if all air is not purged from the water lines and MODEL 1 any time air might be introduced into your home water system YOU ARE NOW READY TO SET THE MAXIMUM AMPERAGE Please continue to page 8 gt A CAUTION Breaker must remain off until installation is complete 7 SETTING THE AMPERAGE IMPORTANT The factory default amperage draw is 15 Amperes To maximize the amount of temperature rise be sure to program your desired amperage to your specific hot water needs Also be sure that your MODEL 1 has been installed and wired to meet the amperage requirements programmed CONTROL END Top Outlet Control Buttons Inlet Bottom 8 A CAUTION Breaker must remain off until installation is complete STEPS 1 Turn on any hot water faucet 2 Allow the water to run for 1 minute Water will not be hot 3 Turn on power to the MODEL 1 by turning on the associated breaker 4 Press and hold both buttons beside the display screen of the MODEL 1 See diagram to the left 5 Release ONLY the top button 6 While continuing to hold the bottom button press and release the top button five times until the number 5 appears The display should start blinking IMPORTANT If the top button is accidentally pressed more than 5 times press and release both buttons to start over 7 Releas
30. mately 16 Ibs installed Certified by a Nationally Recognized Testing Laboratory NRTL for safety and conformity Visit our website for more information regarding certification standards and approvals amps Digital Display Digital LCD and pushbutton user interface to adjust temperature Microprocessor thermostatic setpoint The digital display can be easily temperature control adjusts switched from F to C temperature 60 times per second Warranty 3 year warranty with full unit exchange The water source must fall within 150 to 1500 us of conductivity The only way to Additional annual maintenance required accurately check the conductivity of the Features Silent when operating water is to use a conductivity meter The water company could have this information 41 F 2 0 GPM 23 C 7 6 LPM 55 F 1 5 GPM 30 C 5 7 LPM 82 F 1 0 GPM 45 C 3 8 LPM A CAUTION Breaker must remain off until installation is complete 13 9 TROUBLESHOOTING PROBLEM The MODEL 1 is not producing hot water The digital display does NOT turn on The MODEL 1 is not producing hot water The digital display DOES turn on The MODEL 1 is heating but the water temperature is not hot enough reaching the setpoint temperature 14 A CAUTION Breaker must remain off until installation is complete POSSIBLE CAUSE No power or incorrect wiring Internal part failure Output temperature setting is too low Flow rate is too high
31. n new and in some existing residential construction there is generally enough breaker spaces in the main electrical panel to accommodate several additional circuit breakers for the Heatworks MODEL 1 water heater However in some existing homes the main electrical panel may be nearly full with circuit breakers serving existing load In these cases one or more sub panels each with a single large breaker rated for the entire load of the water heater can be installed off the main panel The boxes for a 50 or 60 amp subpanel can be purchased for about 15 each and the breaker for about 12 Smaller boxes and breakers are slightly less expensive 12 A CAUTION Breaker must remain off until installation is complete BRANCH CIRCUITS AND BREAKERS As a non continuous heating appliance the branch circuit wires and breakers must be sized to at least 100 of the maximum ampere rating of the appliance This is particularly important to avoid over heating of the wires at the connections to the breakers Over heating at the breaker connections may cause nuisance or premature breaker trips It is recommended that the wire for the branch circuits and sub feeds be rated for at least 75 degrees C If you use THHN which is rated for 90C the wire gauge is smaller than standard 75C wire and the nylon covering makes it much easier to pull It also costs about the same Current draw Wire gauge Wire gauge amps 75C 90C THHN 15 14 14 20 12 12
32. nt a debe ser limitada a doce 12 a os a partir de la fecha original de compra o de la fecha original de fabricaci n conforme a lo establecido en esta garant a limitada o por el per odo m s corto permitido por la ley Esta garant a otorga al Propietario derechos legales espec ficos tambi n podr a otorgar al Propietario otros derechos que puedan variar entre un estado a otro estado A PRECAUCI N La caja de circuitos debe estar totalmente 33 apagada hasta que la instalaci n est completa Exclusiones de la Cobertura de esta Garantia Limitada 1 El Fabricante no es responsable por cualquier da o liquido u otros da os y perjuicios derivados directa o indirectamente de cualquier defecto en el calentador Heatworks MODEL 1 sin tanque y su parte s componente s o por su uso 2 El Fabricante no se hace responsable bajo esta garant a limitada o de otra manera si a El calentador de agua o cualquiera de sus componentes han sido objeto de mal uso alteraci n negligencia accidente o de impacto o b El calentador de agua no se ha instalado de acuerdo con las normas locales de plomer a y o c digo s y o regulaci n es de instalaci n o c El calentador de agua no se ha instalado o no se ha mantenido de acuerdo con las instrucciones del Fabricante o si se ha instalado con la orientaci n inapropiada una fijaci n incorrecta o el uso inapropiado de lubricante para tuber as o masilla de plomer a o el uso de cualquie
33. nte 15 libras wando est lleno de agua HEATWORKS RECOMIENDA Anclas para tornillos son altamente recomendadas para la instalaci n o puede perforar directamente a los pernos NO monte la unidad a Una pared de yeso sin utilizar las Anclas para tornillos 2 Asegure los soportes de montaje a una superficie plana como una pared utilizando los tornillos 4 para los Soportes de Montaje 2 Posicione el MODEL 1 en los Soportes Revise la posici n y orientaci n para asegurar que la unidad est a nivel con la entrada posicionada hacia arriba y la salida hacia abajo 22 A PRECAUCI N La caja de circuitos debe estar totalmente 4 Enhebre 2 las Cinchas a trav s de los Soportes y alrededor del MODEL 1 AHORA USTED EST LISTO PARA PROSEGUIR CON LA INSTALACI N DE PLOMER A Por favor contin e a la p gina 5 gt www myheatworks com apagada hasta que la instalaci n est completa 5 INSTALACI N DE PLOMER A Siga cuidadosamente todas las instrucciones de plomer a Este producto debe ser instalado por un plomero calificado de acuerdo con todos los c digos nacionales estatales provinciales y locales de plomer a aplicables STEPS 1 Enjuague las l neas de agua existentes para eliminar todo residuo de pasta de plomer a o residuos causados por cualquier soldadura previa 2 Cierre la llave del agua principal 3 Conecte la l nea de agua caliente a la salida en el MODEL 1 se alizada como outlet
34. o the overall service load of the dwelling when using the optional calculation methods as described in NEC 220 82 and 220 83 not the maximum current rating 48 amps Note that a conventional electric water heater rated at 30 amps load will be rated at 30 amps as is it considered a continuous device www myheatworks com So two Heatworks MODEL 1s will actually add 20 amps more to the existing service load As a result one or more Heatworks MODEL 1s will fit in most homes that have a 150 or 200 amp whole house electrical service or can be installed using one or more sub panels with a breaker that is sized accordingly POWER VOLTAGE MODULATION During operation the Heatworks MODEL 1 is designed to use only the power necessary to heat the water for various combinations of temperature rise and flow rate DISCONNECTS AND SUB PANELS Electrical disconnect devices do not contain circuit breakers and are not required by the National Electrical Code NEC for residential appliances such as the Heatworks MODEL 1 water heater or any appliance rated less than 300 volts However disconnects may be required by the NEC for motor loads and for appliances with multiple circuits in commercial applications A CAUTION Breaker must remain off until installation is complete 11 Electrical sub panels containing circuit breakers may be used with appliances such as the Heatworks MODEL 1 water heater in residential and commercial applications I
35. ones domesticas de agua caliente est ndar se considera un electrodom stico de calefacci n no continuo Debido a la diversidad de calentamiento de agua en un hogar la carga amps que contribuye al calentador MODEL 1 al servicio general de la casa o edificio puede ser calculada utilizando los m todos opcionales del C digo El ctrico Nacional en las secciones NEC 220 82 o 220 83 Para las nuevas viviendas la carga de servicio deber ser calculada utilizando NEC 220 82 Para viviendas existentes la carga de servicio deber ser calculada utilizando NEC 220 83 Por ambos m todos de c lculo la carga del calentador Heatworks MODEL 1 es generalmente a adida a la carga de trabajo al 40 del m ximo valor de calificaci n de placa Por instancia el valor m ximo de corriente amp del Heatworks MODEL 1 es de 48 amps y 40 de esta calificaci n es de 20 amps Los 20 amps es t picamente la carga a adida al servicio de carga total de la vivienda cuando se utilizan los m todos de c lculo opcionales como se describe en NEC 220 82 y 220 83 no la capacidad m xima de corriente de 48 amperios Tenga en cuenta que un calentador www myheatworks com el ctrico de agua convencional a una potencia de 30 amperios de carga ser calificado a 30 amperios y se considera un dispositivo continuo Por lo tanto dos calentadores Heatworks MODEL 1s en realidad solo a adir n 20 amperios m s a la carga existente del servicio Como resultado uno
36. quier instalador o o La cabeza de la ducha regadera no es decalcificada regularmente 3 3 El Propietario y no el Fabricante o su agente representante es responsable y deber pagar por todos los gastos de labor u otros gastos incurridos en el retiro o remoci n o por cualquier otro gasto NO CUBIERTO POR LA GARANT A www myheatworks com apagada hasta que la instalaci n est completa GARANTIA LIMITADA ANULADA 1 Si la unidad se mueve de su lugar original de instalaci n 2 Si la unidad es manipulada o auto mantenida de cualquier forma 3 Si la unidad se instala en el exterior 4 Si la unidad es instalada en una orientaci n distinta a la especificada en el Manual de Usuario e Instalaci n 5 Si se utilizan otros l quidos que no sea otro que agua potable 6 Si m s de 10 de glicol se utiliza con una aplicaci n de calefacci n radiante 7 Si la unidad es utilizada con productos qu micos no aprobados Por favor contacte al Fabricante antes de utilizar cualquier producto qu mico en su MODEL 1 para as no anular la garant a 8 Si se utilizan componentes accesorios no compatibles o no intencionados con el MODEL 1 9 Si esta unidad se utiliza en un escenario no aprobado tal como pero no limitado a un calentador de agua para tanque de peces para calentar piscinas o spas con un convertidor no compatible de AC DC por sus siglas en ingl s si es de menor tama o para la aplicaci n deseada etc tera
37. r s workmanship during the applicable warranty period Owner should contact Manufacturer for a Returned Merchandise Authorization RMA No returns will be accepted by Manufacturer without an RMA number and Manufacturer assumes no responsibility for a water heater returned without an RMA number Water heaters should be wrapped and packaged securely to avoid shipping damage The OWNER will be responsible for shipping costs of the unit in question from Owner to Manufacturer as well as any reinstallation costs All shipments of the Heatworks MODEL 1 from the Manufacturer to the Owner to replace a defective unit shall be made via normal ground transportation If expedited shipment or insurance is required these can be provided at an additional cost A CAUTION Breaker must remain off until installation is complete 17 www myheatworks com INSTALACION amp MANUAL DE USUARIO HEATWORKS MODEL 1 CONTENIDO 1 Informaci n Importante de Seguridad 19 2 C mo usar este Manual 20 Incluido en la caja Herramientas necesarias para la Instalaci n 3 Procedimientos de Instalaci n 21 4 Instalaci n de los Soportes de Montaje 22 5 Instrucciones de Instalaci n de Plomer a 23 Gu as de Instalaci n Paralela 6 Instalaci n El ctrica 25 Ajustes de Amperaje Ajustes de Temperatura 7 Documentaci n T cnica 29 8 MODEL 1 Especificaciones 31 9 Soluci n de Problemas 32 10 Heatworks MODEL 1 Garant a Limitada 33 Registro d
38. r sellador o d El calentador de agua tiene sedimentos dentro de la unidad o e El calentador de agua experimenta cualquier interrupci n de presi n de agua o de flujo es decir la presi n de entrada de agua est por fuera de la especificaci n publicada para el calentador est expuesto a cualquier condici n que cause que el calentador se encienda antes de que el aire sea purgado del calentador o 34 A PRECAUCI N La caja de circuitos debe estar totalmente f El calentador de agua ha sido expuesto a condiciones derivadas de inundaciones terremotos vientos fuego congelaci n rayos truenos o cualquier circunstancia fuera del control del fabricante o g La envoltura etiqueta exterior del calentador de agua se ha roto o manipulado o h El calentador de agua se ha utilizado para otros prop sitos distintos a su finalidad intencionada ejemplo el uso de l quidos que no sea otro que agua potable o i El calentador de agua ha sido manipulado ya sea con electr nicos o un software o j Si hay alg n desmontaje de cualquiera de los componentes distinto a los conectores de cableado y las placas en los extremos o k El calentador de agua se somete a aplicaciones de voltaje de corriente continua cc o El calentador de agua es operado sin la pantalla de filtro de entrada situada dentro de la entrada de agua m La instalaci n del calentador de agua expone la unidad a los elementos o n La mano de obra por cual
39. te 31 apagada hasta que la instalaci n est completa 9 SOLUCI N DE PROBLEMAS PROBLEMA El MODEL 1 no est produciendo agua caliente La Pantalla digital NO enciende El MODEL 1 no est produciendo agua caliente La Pantalla digital SI enciende El MODEL 1 est calentando el agua pero la temperatura NO est suficientemente caliente alcanza la temperatura deseada 32 A PRECAUCI N La caja de circuitos debe estar totalmente POSIBLE CAUSA No hay corriente o cableado incorrecto Fallo Interno El ajuste de la temperatura de salida es demasiado baja para alcanzar la temperatura deseada El Flujo Volum trico Caudal es muy alto Cables Cruzados apagada hasta que la instalaci n est completa SOLUCI N Aseg rese de que los fusibles en el panel el ctrico principal est n encendidos Revise que el cableado del MODEL 1 est propiamente instalado de acuerdo con su el ctrico calificado Aseg rese de que los fusibles no est n da ados o defectuosos Primero trate de restablecer el interruptor de los circuitos apag ndolo y luego enci ndalo Si esto no soluciona el problema cont ctenos para soporte t cnico Incremente el ajuste de la temperatura de su unidad Vea las instrucciones NORMALES DE OPERACI N ajustes de temperatura en la p gina 10 Dependiendo de la temperatura del agua de entrada y la potencia de electricidad de salida a su MODEL 1 pueda que el caudal de agua exceda las
40. tividad La nica manera de comprobar la conductividad es usar un medidor de conductividad La compa a de agua debe proveer esta informaci n 41 F 2 0 GPM 23 C 7 6 LPM 55 F 1 5 GPM 30 C 5 7 LPM 82 F 1 0 GPM 45 C 3 8 LPM Temperatura Salida Rango establecido Ajustes de temperatura Establecida Conectores de agua Presi n Operacional Dimensiones Peso Certificaci n Control de Potencia Pantalla Digital Garant a Caracter sticas Adicionales 50 F a 130 F uso dom stico de agua caliente 10 C a 54 C uso dom stico de agua caliente Uso digital de interface 1 F C ajustes 34 de pulgada o conectores de ajuste de 22 mm M xima de 100 psi 12 5 pulgadas de largo por 6 5 de di metro 10 5 Ibs aproximadamente 16 Ibs instalado Certificado por El Laboratorio de Pruebas Reconocido Nacionalmente NRTL por sus siglas en Ingl s para seguridad amp conformidad Visite nuestra p gina web para m s informaci n acerca de est ndares y aprobaciones de certificaci n Ajustable por el usuario para m ximo uso de corriente Pantalla Digital LCD y bot n para el uso de usuario para ajustar la temperatura deseada La Pantalla digital puede cambiarse f cilmente de F a C 3 a os de garant a con remplazo completo de la unidad No se requiere mantenimiento anual Silencioso al operar PRECAUCI N La caja de circuitos debe estar totalmen
41. ustituir su Heatworks MODEL 1 El Fabricante no se hace responsable por cualquier costo incurrido por el propietario incluyendo sin limitaciones cualquier costo de labor o cualquier costo por materiales para remoci n reparaci n y o reinstalaci n www myheatworks com La responsabilidad m xima del Fabricante se limita al valor del calentador de agua Esta garant a limitada debe ser regida bajo las leyes de los Estados Unidos El remedio expuesto en esta garant a limitada de responsabilidad es el nico remedio disponible para el Propietario o para cualquier otra persona por incumplimiento de cualquier convenio deber u obligaci n por parte del Fabricante El Fabricante no se hace responsable ante el Propietario o alg n tercero por cualquier perdida lesiones personales o da os a la propiedad directa o indirectamente a causa del calentador de agua Heatworks MODEL 1 Bajo ninguna circunstancia el Fabricante es responsable ante el Propietario o hacia alg n tercero por da os incidentales consecuentes indirectos especiales contingentes o punitivos de cualquier tipo si dicha reclamaci n se basa en la garant a contrato negligencia responsabilidad estricta u otra responsabilidad extracontractual agravio o de otra manera Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes por lo tanto las limitaciones o exclusiones podr an no aplicarle al Propietario En dichos casos la gara
42. www myheatworks com INSTALLATION amp USER MANUAL HEATWORKS MODEL 1 CONTENTS 1 Important Safety Information 1 2 How to Use this Manual 2 Included in the Box Required for Installation 3 Heatworks MODEL 1 Diagram 3 4 Installing the Mounting Brackets 4 5 Plumbing Installation 5 Installing Units in Parallel 6 Electrical Installation 7 Setting the Amperage Adjusting the Temperature 7 Electrician s White Paper 1 8 MODEL 1 Specifications 13 9 Troubleshooting 14 10 Heatworks MODEL 1 Limited Warranty 15 Warranty Registration 11 Return Process 17 A CAUTION Breaker must remain off until installation is complete www myheatworks com PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION AND USE FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE SERIOUS INJURY OR DEATH IMPROPER INSTALLATION OR USE WILL VOID YOUR WARRANTY Check our website 4 www myheatworks com for the latest version of the Installation amp User Manual HEATWORKS MODEL 1 www myheatworks com 1 IMPORTANT SAFETY INFORMATION TURN OFF CIRCUIT BREAKER AND WATER SUPPLY BEFORE INSTALLING THE MODEL 1 SERIOUS BODILY INJURY OR DEATH MAY OCCUR IF YOU IGNORE THIS WARNING Shut off all power to the unit directly at the breaker box prior to installing or inspecting your Heatworks MODEL 1 The Heatworks MODEL 1 must be installed by a licensed electrician and licensed plumber in a
Download Pdf Manuals
Related Search
Related Contents
1 - Schneider Electric Important Customer Information Copyright © All rights reserved.