Home
KOHLER K-T134-4D-CP Installation Guide
Contents
1. Apply thread sealant to the nipple and install the spout to the nipple O Carefully tighten with a clean strap wrench Remove excess putty 114497 2 CC 4 Kohler Co Shower Elbow Apply plumbers putty _to escutcheon A Setscrew sa Shower Arm Pa Showerhead 2 Install Shower Arm and Showerhead CAUTION Risk of product damage To avoid plugging the showerhead spray outlets use thread sealant tape on the shower arm threads Do not use thread sealant compound pipe dope Remove the temporary nipple from the shower elbow Apply a bead of plumbers putty or other sealant to the back of the escutcheon according to the manufacturer s instructions Slide the escutcheon over the shower arm Apply thread sealant tape and install the shower arm to the shower elbow Carefully tighten with a clean strap wrench Press the escutcheon against the finished wall and secure with the setscrew Remove all excess putty With the showerhead off flush out the system Apply thread sealant tape to the shower arm and thread the showerhead to the shower arm Kohler Co 5 114497 2 CC Standard High Flow Valve Valve Setscrew 3 Water Temperature Adjustment CAUTION Risk of personal injury The water temperature should never be set above 120 F 49 C NOTE Do not remove the O ring and collar at this time Removing the O
2. Manija de seis aspas O Instale la manga y la base en la espiga de la v lvula y fije con el tornillo Instale la manija sobre la base y fije bien con el tornillo de fijaci n Manija ovalada Instale la manga y la base en la espiga de la v lvula Alinee la manija y f jela a la espiga de la v lvula con el tornillo Presione la tapa en la manija y fije con el tornillo peque o Alinee la manija sobre la base y fije bien con el tornillo de fijaci n Kohler Co Espa ol 7 114497 2 CC USA 1 800 4 KOHLER Canada 1 800 964 5590 M xico 001 877 680 1310 kohler com THEBOLDIOOK OF KOHLER 2004 Kohler Co 114497 2 CC
3. Llave de Cinta selladora correa Term metro de roscas v A FA Juego de Masilla de Llave destornilladores plomeria hexagonal Gracias por elegir los productos de Kohler Apreciamos su elecci n por la calidad de Kohler Dedique unos minutos para leer este manual antes de comenzar la instalaci n En caso de problemas de instalaci n o de funcionamiento no dude en contactarnos Nuestros n meros de tel fono y nuestra p gina web se encuentran en la ltima p gina Gracias nuevamente por escoger a Kohler Antes de comenzar Cumpla con todos los c digos locales de plomer a y de construcci n La pared acabada o la unidad de la ba era ducha debe instalarse antes que la guarnici n Se recomienda determinar si la temperatura m xima del agua es aceptable antes de instalar esta guarnici n Si es necesario realizar ajustes de temperatura consulte la secci n Ajuste de la temperatura del agua La presi n del agua hace que la v lvula se cierre No fuerce la manija en ninguna direcci n Para cerrar la v lvula gire suavemente a la posici n cerrada Off Cierre el suministro principal de agua La empresa Kohler se reserva el derecho de modificar el dise o de los productos sin aviso tal como se especifica en la lista de precios 114497 2 CC Espa ol 2 Kohler Co Niple de 1 2 Niple de 1 2 Pal i Surtidor con Surtidor de vi 4 7 8 12 4 cm vi de
4. refer to the Water Temperature Adjustment section The valve shuts off by water pressure Do not force the handle in any direction To turn the valve off gently turn it to the Off position Shut off the main water supply Kohler Co reserves the right to make revisions in the design of products without notice as specified in the Price Book Kohler Co 3 114497 2 CC 1 2 Nipple pp A Nipple 4 7 8 12 4cm 7 3 4 19 7 cm N _ Spout N Diverter Spout 7 16 1 2 Va vem z 1 3 cm Apply 4 plumbers Apply plumbers putty utty pe 1 2 Nipple 7 3 4 19 7 cm Non Diverter Spout KA 6 1 4 15 9 cm Apply plumbers a 1 Install the Spout Remove the temporary nipple For the 4 7 8 12 4 cm diverter spout Apply thread sealant to a 1 2 NPT nipple and install it to the bath elbow so it extends 7 16 1 1 cm beyond the finished wall For the 7 3 4 19 7 cm diverter spout Apply thread sealant to a 1 2 NPT nipple and install it to the bath elbow so it extends 1 2 1 3 cm beyond the finished wall For the 7 3 4 19 7 cm non diverter spout Apply thread sealant to a 1 2 NPT nipple and install it to the bath elbow so it extends 6 1 4 15 9 cm beyond the finished wall Apply a bead of plumbers putty or other sealant around the inlet end of the spout according to the manufacturer s instructions
5. ring and collar will change the factory setting for the maximum water temperature Turn the valve clockwise to the full open position and let the hot water run for several minutes Position a thermometer in the water stream and check the temperature For minor water temperature changes adjust the setscrew and recheck the water temperature O For major water temperature changes remove the O ring and collar from the valve stem Slowly rotate the valve stem until the desired maximum water temperature is reached O Reinstall the collar on the valve stem with the setscrew against the side of the tab Reinstall the O ring rotate the valve stem counterclockwise to shut the water off Recheck the water temperature to ensure desired maximum water temperature NOTE After adjustment complete the required information on the valve label if supplied 114497 2 CC 6 Kohler Co Valve Stem Sleeve os Stem End Cap N EN 7 Washer A 9 Short Sleeve Qe __ Screw Bonnet ve o O Ring e Center Cap Long Sleeve Centering Washer Screws Handle Arm 4 Install the Face Plate and Lever Handle CAUTION Risk of product damage to the K 306 KS valve assembly When using this valve in a fiberglass or acrylic installation use the Thin Wall Installation Kit 88526 O Remove and discard the plaster guard and or dome if installed Fit the
6. un bec non inverseur de 7 3 4 19 7 cm Appliquer un ruban d tanch it pour filetage un mamelon de 1 2 NPT et l installer la baignoire de mani re ce qu il s tende de 6 1 4 5 9 cm au del du mur fini Appliquer du mastic d tanch it ou un produit semblable sur le p rim tre de l extr mit arri re du bec selon les instructions du fabricant du mastic Appliquer un ruban d tanch it sur la tige filet e et installer le bec sur le mamelon Serrer doucement l aide d une cl sangle propre Retirer tout exc dent de mastic 114497 2 CC Fran ais 4 Kohler Co Coude de douche Appliquer du mastic Ed de plombier sur l applique l Vis de retenue Bras de du q a Pomme de douche 2 Installer le bras et la pomme de douche ATTENTION Risque d endommagement du produit Pour viter de boucher les orifices de la pomme de douche utiliser du ruban d tanch it sur la tige filet e du bras de douche Ne pas utiliser de joint d tanch it pour filetage colle tuyau O Retirer le mamelon temporaire du coude de la douche Appliquer du mastic d tanch it ou un produit semblable au dos de l applique selon les instructions du fabricant du mastic Glisser l applique sur le bras de douche Appliquer du ruban d tanch it et installer le bras de douche au coude de douche Serrer douce
7. yeso Empaque de lt central con c pula anillo O Ring 0 Manga larga Arandela de centrar Tornillos Brazo de la manija 4 Instale la placa circular y la manija de palanca PRECAUCI N Riesgo de da os al montaje de la v lvula K 306 KS En caso de utilizar esta v lvula en una instalaci n de fibra de vidrio o acr lica utilice el juego de instalaci n para paredes delgadas 88526 Retire y deseche el protector de yeso y o la c pula si est n instalados Coloque la placa circular y la arandela de centrar sobre la v lvula y fije con dos tornillos Gire la espiga de la v lvula completamente hacia la izquierda Manija de palanca Deslice un empaque de anillo O ring sobre la manija y deslice la pieza de inserci n por el v stago de la manija n Coloque el segundo empaque de anillo O ring por el v stago de la manija Fije el cuerpo de la v lvula con una arandela y una tuerca Apriete el tap n terminal en la manija con la mano Instale la manga y la base en la espiga de la v lvula O Alinee el montaje de la manija y fije la manija a la espiga de la v lvula con el tornillo 114497 2 CC Espa ol 6 Kohler Co Espi lvul Espiga de v lvula Spiga ge VANNES Manga Manga Tornillo de e Tornillo Tornillo de fijaci n JA lt _ fijaci n CR B r Base a TE Tornillo 7 Y Tornillo Manija O Manija Tap n 5 Instalaci n de otros estilos de manija
8. 49 C NOTA No retire el empaque de anillo O ring ni el collar n en este momento El ajuste de la temperatura m xima del agua establecido en f brica cambiar si se retira el empaque de anillo O ring y el collar n O Gire la v lvula a la derecha a la posici n completamente abierta y deje correr el agua caliente durante varios minutos Coloque un term metro en el agua y verifique la temperatura Para cambios leves de la temperatura del agua ajuste el tornillo de fijaci n y vuelva a comprobar la temperatura del agua Para cambios importantes de la temperatura del agua retire el empaque de anillo O ring y el collar n de la espiga de la v lvula Gire lentamente la espiga de la v lvula hasta obtener la temperatura m xima deseada del agua Vuelva a instalar el collar n en la espiga de la v lvula con el tornillo de fijaci n hasta que quede contra el lado de la leng eta Reinstale el empaque de anillo O ring y gire la espiga a la izquierda para cerrar el suministro de agua Vuelva a comprobar la temperatura del agua para asegurarse de tener la temperatura m xima deseada NOTA Una vez ajustado rellene la informaci n requerida en la etiqueta de la v lvula si est incluida Kohler Co Espa ol 5 114497 2 CC Espiga de valvula Manga Espiga de valvula A terminal Ley gt Arandela A P co peque a Deseche el Base v Tomillo protector de
9. Installation Guide Bath and Shower Faucet Trim K T130 K T132 Ge M product numbers are for Mexico i e K 12345M Los n meros de productos seguidos de M corresponden a M xico Ej K 12345M Francais page Francais 1 Espa ol p gina Espa ol 1 FBO D LOOK T 114497 2 CC KOHLER IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING Risk of scalding or other severe injury Before completing installation the installer must set the maximum water temperature setting of this valve to minimize the risks associated with scalding hazards according to ASTM F 444 Do not install a shut off device on either outlet of this valve The installation of any such device may create a cross flow condition at the valve and affect the water temperature e Factors that change the temperature of the water supplied to the valve such as seasonal water temperature changes and water heater replacement or servicing will change the maximum water temperature supplied by the valve and may create a scalding hazard The pressure balanced valve will not compensate for changes in the water supply temperature adjust the maximum water temperature setting of this pressure balanced valve when such changes occur e Pressure balanced valves may not provide protection against scalding if there is a failure of other temperature limiting devices elsewhere in the plumbing system The installer is resp
10. crou Serrer la main le bouchon la poign e O Installer le manchon et le chapeau sur la tige de la valve Aligner l ensemble de la poign e et s curiser cette derni re la tige de la valve avec la vis Kohler Co Fran ais 7 114497 2 CC Ti l l Tige de valve gene IB vee Manchon Lo vis Vis de gt lt pen Ch Chapeau gt if Vis A Pa Poign e 7 O we Capuchon 5 Installer d autres styles de poign es Poign e a six broches O Installer le manchon et le chapeau sur la tige de la valve et s curiser avec la vis Presser la poign e sur le chapeau et s curiser en place avec la vis de retenue Poign e ovale Installer le manchon et le chapeau sur la tige de la valve Aligner la poign e et s curiser sa tige avec la vis Presser le bouchon sur la poign e et s curiser avec une petite vis Aligner la poign e sur le chapeau et s curiser en place avec la vis de retenue 114497 2 CC Frangais 8 Kohler Co Gu a de instalaci n Guarnici n de grifer a de ba era y ducha INSTRUCCIONES IMPORTANTES L ALAS Y GU RDELAS PARA EL CLIENTE ADVERTENCIA Riesgo de quemaduras u otras lesiones graves e Antes de terminar la instalaci n el instalador debe fijar la temperatura m xima del agua de la v lvula para reducir el riesgo de quemadura seg n la norma ASTM F 444 No instale llaves de pas
11. essaire se r f rer la section R glage de la temp rature d eau La valve s arr te par pression d eau Ne pas forcer la poign e dans aucune direction Pour fermer la poign e la tourner doucement sur la position Off Couper l alimentation d eau principale 114497 2 CC Fran ais 2 Kohler Co Avant de commencer cont Kohler Co se r serve le droit d apporter toutes modifications sur le design des produits et ceci sans pr avis tel que sp cifi dans le catalogue des prix Kohler Co Fran ais 3 114497 2 CC Mamelon de 1 2 _ Mamelon de 1 2 o A om Bec inverseur ies Me N de 7 3 4 1 19 7 cm Kom 4 1 30m 7 Appliquer du Appliquer du mastic mastic de de plomberie plamene Mamelon de 1 2 z Bec non p inverseur de 6 1 4 7 3 4 19 7 cm 1 15 9 cm A Appliquer du mastic de plomberie 1 Installer le bec Retirer le mamelon temporaire Pour un bec inverseur de 4 7 8 12 4 cm Appliquer un ruban d tanch it pour filetage un mamelon de 1 2 NPT et l installer la baignoire de mani re ce qu il s tende de 7 16 1 1 cm au del du mur fini O Pour un bec inverseur de 7 3 4 19 7 cm Appliquer un ruban d tanch it pour filetage un mamelon de 1 2 NPT et l installer la baignoire de mani re ce qu il s tende de 1 27 1 3 cm au del du mur fini O Pour
12. faceplate and centering washer over the valve and secure with two screws Rotate the valve stem fully counterclockwise Lever Handle Slide an O ring fully onto the handle and slide the insert over the handle shank Fit the second O ring over the handle shank Secure with the washer and nut Hand tighten the end cap to the handle Install the sleeve and bonnet to the valve stem Align the handle assembly and secure the handle to the valve stem with the screw Kohler Co 7 114497 2 CC Valve Stem Sleeve Sleeve Screw Setscrew a _Setscrew Bonnet Tea a eA Bonnet TE Screw 2 Screw Handle m O Handle Cap 5 Installing Other Handle Styles Six Prong Handle O Install the sleeve and bonnet to the valve stem and secure with the screw Press the handle onto the bonnet and secure in place with the setscrew Oval Handle Install the sleeve and bonnet to the valve stem Align the handle and secure to the valve stem with the screw Press the cap onto the handle and secure with the small screw Align the handle on the bonnet and secure in place with the setscrew 114497 2 CC 8 Kohler Co Guide d installation Garniture de robinet de baignoire et de douche INSTRUCTIONS IMPORTANTES LIRE ET LAISSER AU CLIENT A AVERTISSEMENT Risque de br lures ou de blessures graves e Avant de com
13. installer le collier sur la tige de la valve de mani re a placer la vis de retenue contre la languette R installer le joint torique tourner la tige de la valve vers la gauche pour arr ter l eau Re v rifier la temp rature d eau pour en assurer la temp rature maximale REMARQUE Apr s le r glage compl ter les informations requises sur l tiquette de la valve si fournie 114497 2 CC Fran ais 6 Kohler Co Tige de la valve Manchon Tige de la valve Bouchon Ley L extr mit AG Couvercle Rondelle A E 6 r Manchon RE cour NE Nis Chapeau 6 5 0 Joint torique Capuchon ONS 2 central Manchon ng x Vis Bras de poign e 4 Installer le couvercle et la poign e du levier ATTENTION Risque d endommagement l ensemble de valve K 306 KS Lorsque cette valve est utilis e en installation fibres de verre ou acrylique utiliser le kit d installation de mur fin 88526 Retirer et jeter le renfort en pl tre et ou d me s il est install Installer le couvercle et centrer la rondelle sur la valve puis s curiser au moyen de deux vis Tourner la tige de la valve compl tement vers la gauche Poign e du levier O Glisser un joint torique compl tement sur la poign e ainsi que l insertion sur le manche de la poign e Positionner le second joint torique sur le manche de la poign e S curiser au moyen de la rondelle et de l
14. lo de fijaci n we Brazo de ducha i P Cabeza de ducha 2 Instale el brazo y la cabeza de ducha PRECAUCI N Riesgo de da os al producto Para no obstruir las salidas del rociador de la cabeza de ducha utilice cinta selladora de roscas en las roscas del brazo de la ducha No utilice sellador l quido de rosca pasta lubrificante O Retire el niple provisional del codo de la ducha Aplique una tira de masilla de plomer a u otro sellador en la parte posterior del chapet n seg n las instrucciones del fabricante Deslice el chapet n sobre el brazo de la ducha O Aplique cinta selladora de roscas e instale el brazo de ducha en el codo de la ducha Apriete cuidadosamente con una llave de correa limpia Presione el chapet n contra la pared acabada y fije con el tornillo de fijaci n Elimine el exceso de masilla de plomer a Con la cabeza de ducha desmontada haga circular agua por el sistema Aplique cinta selladora de roscas en el brazo de ducha y enrosque la cabeza de ducha en el brazo de ducha 114497 2 CC Espa ol 4 Kohler Co Valvula de Valvula alto flujo estandar Tornillo de Leng eta fijacion Collarin Etiqueta SQ0 de la v lvula Tornillo de fijaci n Empaque de anillo O Ring 3 Ajuste de la temperatura del agua PRECAUCI N Riesgo de lesiones personales La temperatura del agua nunca debe ajustarse a m s de 120 F
15. mencer l installation l installateur doit r gler la temp rature maximale de l eau de cette valve pour r duire au minimum les risques de br lures ceci conform ment la norme ASTM F 444 e Ne pas installer un dispositif d arr t sur les sorties de cette valve L installation d un tel dispositif peut cr er une condition d coulement crois au r gulateur et modifier la temp rature de leau Les facteurs qui changent la temp rature de l eau aliment e cette valve tels que les changements de temp rature d eau saisonniers et le remplacement ou l entretien du chauffeau changeront la temp rature maximale de l eau fournie par le r gulateur et pourront pr senter un danger de br lures e La valve pression quilibr e ne compensera pas les changements de temp rature d alimentation d eau ajuster la temp rature maximale de cette valve pression quilibr e si de tels changements se produisent Les valves pression quilibr e peuvent ne pas assurer une protection contre les br lures en cas de d faillance d autres dispositifs de limitation de temp rature install s ailleurs sur le r seau de plomberie L installateur est responsable de l installation de la valve et du r glage de la temp rature maximale de l eau de cette valve pression quilibr e conform ment aux instructions Cette valve satisfait ou exc de les exigences des normes ANSI A112 18 1M et ASSE 1016 S il ne vous est pas pos
16. ment l aide d une cl sangle propre Presser l applique contre le mur fini et s curiser avec la vis de retenue Retirer tout exc dant de mastic Avec la pomme de douche ferm e purger le syst me Appliquer un ruban d tanch it sur le bras de douche et visser la pomme de douche sur le bras de douche Kohler Co Fran ais 5 114497 2 CC Valve Valve haut standard d bit L tt anguette Vis de retenue Cie Languette 0 Etiquette de valve 2 Collie o Vis de retenue gt Joint torigue 3 R glage de la temp rature d eau ATTENTION Risgue de blessure corporelle La temp rature de l eau ne devrait jamais tre sup rieure 120 F 49 C REMARQUE Ne pas retirer le joint torique ou le collier pour le moment Retirer le joint torique changerait le r glage d usine de la temp rature maximale de l eau Tourner la valve vers la droite a la position ouverte et laisser couler l eau chaude pendant quelques minutes Placer un thermom tre dans le courant d eau et v rifier la temp rature Pour de petits changements de temp rature ajuster la vis de serrage et re v rifier la temp rature d eau Pour de grands changements de temp rature retirer le joint torique et le collier de la tige de la valve Tourner lentement la tige de la valve jusqu a atteindre la temp rature maximale d sir e R
17. o en ninguna de las salidas de esta v lvula La instalaci n de tales dispositivos puede producir contracorriente en la v lvula y afectar la temperatura del agua Los factores que cambian la temperatura del agua suministrada a la v lvula tales como la temperatura estacional y el mantenimiento o reemplazo del calentador de agua pueden causar quemaduras La v lvula reguladora de presi n no compensar los cambios de temperatura del agua ajuste la temperatura m xima del agua de esta v lvula reguladora de presi n cuando se produzcan tales cambios Es posible que las v lvulas reguladoras de presi n no protejan contra las quemaduras si otros aparatos de limitaci n de la temperatura en el sistema de plomer a no funcionan correctamente El instalador tiene la responsabilidad de instalar la v lvula y ajustar la temperatura m xima del agua seg n las instrucciones Esta v lvula cumple o excede la norma ANSI A112 18 1 y ASSE 1016 Si usted no entiende las instrucciones de instalaci n o de ajuste de temperatura contenidas en este documento llame a nuestro Departamento de Atenci n al Cliente al 1 800 4 KOHLER Fuera de los Estados Unidos comun quese con su distribuidor AVISO IMPORTANTE A LOS INSTALADORES Rellene los espacios en blanco en la Gu a del usuario y en la etiqueta de la v lvula Guarde la Gu a del usuario para referencia futura Kohler Co Espa ol 1 114497 2 CC Herramientas y materiales
18. onsible for installing the valve and adjusting the maximum water temperature of this pressure balanced valve according to instructions This valve meets or exceeds ANSI A112 18 1 and ASSE 1016 If you do not understand any of the installation or temperature adjustment instructions in this document in the United States please contact our Customer Service Department at 1 800 4 KOHLER Outside the U S please contact your distributor IMPORTANT NOTICE TO INSTALLERS Please fill in the blanks in the information box in the Homeowners Guide and on the valve label Retain the Homeowners Guide for future reference 114497 2 CC 2 Kohler Co Tools and Materials Strap a Thread Wrench Thermometer Sealant A 6 Assorted Plumbers Hex Screwdrivers Putty Wrench Thank You For Choosing Kohler Company We appreciate your commitment to Kohler quality Please take a few minutes to review this manual before you start installation If you encounter any installation or performance problems please don t hesitate to contact us Our phone numbers and website are listed on the back cover Thanks again for choosing Kohler Company Before You Begin Observe all local plumbing and building codes The finished wall or bath shower unit must be installed prior to installing this trim We recommend that you determine if the maximum water temperature is acceptable before installing this trim If temperature adjustment is needed
19. sible de comprendre les instructions d installation ou de r glage de la temp rature donn es par ce document veuillez contacter notre d partement du service client le aux Etats Unis 1 800 4 KOHLER Hors des Etats Unis veuillez contacter votre distributeur Kohler Co Fran ais 1 114497 2 CC INSTRUCTIONS IMPORTANTES cont AVIS IMPORTANT AUX INSTALLATEURS Veuillez remplir le coupon dans le guide du propri taire ainsi que sur l tiquette de la valve Conserver le guide du propri taire pour future r f rence Outils et mat riels sangle Thermom tre d tanch it pour filetage sd A K Tournevis Mastic de Cl assortis plombier hexagonale Merci d avoir choisi la compagnie Kohler Nous appr cions votre engagement envers la qualit Kohler Veuillez prendre s il vous plait quelques minutes pour lire ce manuel avant de commencer l installation Ne pas h siter nous contacter en cas de probl me d installation ou de fonctionnement Nos num ros de t l phone et notre adresse du site internet sont au verso Merci encore d avoir choisi la compagnie Kohler Avant de commencer Respecter tous les codes de plomberie et de b timent locaux Le mur fini ou la baignoire douche doit tre install avant d installer cette garniture Nous conseillons de d terminer si la temp rature maximale de l eau est acceptable avant d installer la garniture Si un r glage de temp rature est n c
20. sviador de 1 1 cm 1 3 cm Apli a A plique Aplique masilla de plomeria masilla de prometia _ Niple de 1 2 lt gt Surtidor sin desviador de 6 1 4 3 4 15 9 cm gt 1 3 4 19 7 cm x Aplique masilla de plomeria 1 Instale el surtidor Retire el niple provisional Para el surtidor con desviador de 4 7 8 12 4 cm Aplique cinta selladora de roscas a un niple con rosca NPT de 1 2 e inst lelo en el codo de la ba era de modo que sobresalga 7 16 1 1 cm de la pared acabada O Para el surtidor con desviador de 7 3 4 19 7 cm Aplique cinta selladora de roscas a un niple con rosca NPT de 1 2 e inst lelo en el codo de la ba era de modo que sobresalga 1 2 1 3 cm de la pared acabada O Para el surtidor sin desviador de 7 3 4 19 7 cm Aplique cinta selladora de roscas a un niple con rosca NPT de 1 2 e inst lelo en el codo de la ba era de modo que sobresalga 6 1 4 15 9 cm de la pared acabada Aplique masilla de plomer a u otro sellador alrededor del extremo de entrada del surtidor seg n las instrucciones del fabricante Aplique cinta selladora de roscas en el niple e instale el surtidor en el niple Apriete cuidadosamente con una llave de correa limpia Elimine el exceso de masilla de plomer a Kohler Co Espa ol 3 114497 2 CC Codo de ducha Aplique masilla de a plomeria al chapet n l z Tornil
Download Pdf Manuals
Related Search
Related Contents
PATRIMONIO CULTURAL - Ministerio de Defensa Manual de Usuario Inscripción de Aspirantes Copyright © All rights reserved.
Failed to retrieve file