Home

Water Worker HT14B Use and Care Manual

image

Contents

1. 9015 376 07 12 WATERO6 WORKER MANUEL D INSTALLATION POUR SYST ME DE RESERVOIRS VERTICAUX POUR PUITS Modeles HT14B HT20B HT30B HT32B HT44B HT62B HT86B et HT119B Veuillez conserver ce manuel avec le r servoir pour vous y r f rer ult rieurement Ce dont vous aurez besoin Outils recommand s Cl ajustable Pieces additionnelles requises non incluses Raccord de 25 4 mm 1 po NPTF pour reservoir d eau Tournevis Robinet de vidange Pince ajustable Ruban a mesurer Manostat Manom tre Croix du r servoir 25 4 cm L x 2 54 cm 10 Lx1 NPTM Ruban Teflon Cl tuyau Manom tre pneus Scie m taux Soupape de surpression Clapet de non retour Avant de commencer Assurez vous de toujours quiper ad quatement votre syst me pour puits avec une bonne soupape de surpression Elle devrait tre en mesure d vacuer le d bit complet de la pompe ou en dessous de la pression maximale de fonctionnement du composant pr sentant la plus faible pression dans le syst me Consultez le manuel du propri taire de votre pompe pour l information de sortie Cela est primordial pour le fonctionnement s curitaire du syst me pour puits Ce produit est fourni avec une garantie de 5 ans Voir la garantie limit e de WATER WORKER pour les d tails WARNING VEUILLEZ LIRE ATTENTIVEMENT LE MANUEL D INSTALLATION DE FONCTIONNEMENT ET D ENTRETIEN DU PRODUIT OMETTRE DE SUIVRE LES INSTRUCTIONS ET LES AVERTI
2. tre 2 psi en dessous de la pression la moins lev e de ces deux chiffres C est dire la pression du r servoir devrait tre r gl e environ 18 psi si le capuchon indique un r glage de 20 40 ou environ 28 psi s il indique un r glage de 30 50 Le tableau Annexe A indique la charge d air dans le r servoir lorsqu il est exp di de l usine Rel chez ou ajoutez de l air pour bien ajuster la pression Si cette charge est trop lev e laissez chapper un peu d air en appuyant sur la broche l int rieur du robinet d admission d air Si la charge n est pas suffisamment lev e pompez la avec une pompe pour pneus de bicyclette ou avec un compresseur d air Sinon vous pouvez ajuster le manostat de mani re ce qu il corresponde la pression dans le r servoir Consultez les instructions l int rieur du capuchon du manostat pour prendre connaissance de la d marche suivre Ouvrez le robinet vanne afin de permettre l eau de refluer dans le r servoir Cela est le robinet que vous avez ferm l tape 1 3 consultez l tape 13 pour voir la photo du robinet vanne Fig 18 Ouvrez le robinet dans la maison qui se trouve le plus lev et le plus loign du r servoir Cela laissera chapper l air du syst me mesure qu il se remplit d eau R tablissez l alimentation lectrique La pompe se mettra en marche et remplira le r servoir V rifiez le syst me pour des fuites
3. Install the tank cross assembly on the tank Either use the new connections that hold the tank according to Step ll above or and the tank cross pressure reuse the tank cross assembly gauge pressure switch assembly from the old tank in place Fig 7 8 3 Apply Teflon tape to the threads 7 Lay the tank on its side with tank Rigas bottom ce the stem of Find the fuse box or circuit breaker panel for your house Turn off the power to the well pump For your safety A WARNING the information in this manual must be followed to minimize the risk of electric shock property damage or personal injury Properly ground to confirm with all governing codes and ordinances cross pointing up Remove tank cross assembly by unscrewing it using the pipe wrench Fig 9 the tank cross assembly remove the new tank cross pressure gauge pressure switch pressure relief valve and pipe nipple from their packages Assemble the tank cross unit Apply Teflon tape to the male threads on the tank cross pressure gauge and both ends of the pipe nipple Fig 10 Apply clockwise i e bottom up and coming towards you Apply 3 full turns the tank cross Insert the stem in the female threaded fitting on the bottom of the tank Tighten hand tight then wrench tight Fig 14 15 Step IV Install the new tank 1 Install the new tank Place it where the old tank was or stand it in a position so that you can mak
4. Si vous constatez une fuite fermez imm diatement l alimentation lectrique et r parez la fuite au joint L amorcage de la pompe si cela est une pompe jet devrait prendre de 30 secondes 1 minute Si la pompe ne remplit pas le r servoir et s teint au bout d environ une minute v rifiez le manom tre Si la jauge se meut laissez la pompe fonctionner Si la jauge ne meut pas fermez l alimentation lectrique Cela signifie que le manostat est soit d fectueux ou n a pas t install correctement V rifiez les instructions du fabricant Remplacez le si n cessaire et testez le syst me une autre fois pour vous assurer qu il est bien install Ouvrez un robinet proximit pour vous assurer que le syst me fonctionne correctement ANNEXE A MALLLTTTTTTTLLI LL R SERVOIRS VERTICAUX NUM RO PRESSION DE PRECHARGE IMPORTANT Consignes de s curit Assurez vous de les lire IMPORTANT Ce r servoir est con u pour utilisation avec de l eau potable et est limit une pression maximale de 100 psi et une temp rature de service de 54 44 C 130 F Veuillez prendre note qu un chauffe eau ou qu une chaudi re dans un syst me de chauffage eau chaude chauffera couramment l eau une temp rature plus lev e que 54 44 C 130 F Utilisez un r servoir d expansion thermique pour un d bordement d eau chaude provenant d un chauffe eau ou utilisez un r servoir d expansion pour un d
5. dans un seau ou dans le siphon de sol Fixez un tuyau d arrosage au robinet l avant de la croix du r servoir Placez l autre extr mit du tuyau dans le seau de fa on ce qu il soit plus bas que le robinet Ouvrez le robinet de vidange et videz l eau du r servoir Il sera peut tre n cessaire d vacuer l air par le robinet d admission d air afin de permettre au r servoir de se vider compl tement Fig 2 D connectez le c blage au manostat Avant de d connecter le c blage assurez vous que l alimentation lectrique la pompe soit bien ferm e Desserrez l crou hexagonal sur le dessus du capuchon avec des pinces ou une cl ajustable D vissez manuellement Fig 3 Enlevez le capuchon au manostat D vissez les connexions pour les c bles Sur le manostat indiquez quel c ble va sur quelle vis prendre note que le cable vert se branche l avant de la vis indiquez en utilisant du ruban cache au besoin Fig 4 D vissez le raccordement collets qui maintient le c blage au manostat Fig 5 Tirez les c bles hors du manostat Fig 6 Desserrez et d vissez le raccord union qui maintient le r servoir et le bloc comprenant la croix du r servoir le manom tre et le manostat Fig 7 8 D posez le r servoir sur le c t la croix du r servoir pointant vers le haut Enlevez le bloc croisillon du r servoir en le d vissant avec la cl tuyau Fig 9 tape II asse
6. adjust the piping to reach the new connections b Install a pressure relief valve at the tank connection to ensure the safety of the system c If you have a deep well submersible pump remove all the air charging devices from the well system snifter valves bleeder Part 9015 376 07 12 E orifices vacuum lines and connection Then plug the holes where these devices were located see your owner s manual for location of these devices These devices are not needed for pre charged tanks and if they are not removed and the holes plugged air can get into the well system cause surges damage the system and impair performance d If you have a jet pump remove the fittings and plug the openings where the vacuum or air lines and air volume controls connect to the pump or piping If not removed and plugged they can allow air into the pipes which can damage the well system and impair performance e In addition to the above follow Steps through V 3 If you are replacing a diaphragm or bladder style tank with this Water Worker diaphragm tank a If the two tanks are the same size follow Steps through V b If they are different sizes follow Steps through V and also adjust the piping as necessary to accommodate the new size 4 It is good practice to replace the pressure gauge and the pressure switch whenever you replace an old tank Of course you can re use the tank cross assembly if you are replacing a diaphragm ta
7. com Use proper safety equipment when installing As in all plumbing products and water storage CAUTION vessels bacteria can grow in this Product especially during times of non use Consult your local plumbing professional regarding any steps you may wish to take to safely disinfect your home s plumbing system DANGER EXPLOSION HAZARD WHEN THE WARNING WELL TANK HAS BEEN IN SERVICE AND A CHANGE TO A HIGHER PRE CHARGE PRESSURE IS NECESSARY AWARNING DUE TO A REQUIRED CHANGE IN THE PRESSURE SWITCH SETTING FAILURE TO FOLLOW INSTRUCTION MANUAL CAN CAUSE A RUPTURE OR EXPLOSION POSSIBLY CAUSING SERIOUS OR FATAL INJURY AND OR PROPERTY DAMAGE DO NOT ADJUST THE PRE CHARGE PRESSURE IF THERE HAS BEEN A REDUCTION OF THE PUMP CYCLE TIME OR THE PRE CHARGE PRESSURE COMPARED TO ITS INITIAL SETTING THIS IS BECAUSE REDUCTION IN PUMP CYCLE TIME CAN RESULT FROM LOSS OF TANK AIR PRESSURE WHICH IN TURN CAN MEAN THERE MAY BE INTERNAL CORROSION AND ANY RE PRESSURIZATION OR ADDITIONAL PRESSURE COULD RESULT IN RUPTURE OR EXPLOSION AND OR PROPERTY DAMAGE MAXIMUM WORKING PRESSURES Every well WARNING tank is air tested to 125 psig the maximum working pressure for the well tank line Should pressures exceed 125 psig proper selection and sizing of an ASME constructed well tank should be made RELIEF VALVE REQUIRED A relief valve should be installed which is set to open at excessive pressures 75 psig or more This will protect the
8. de WATER WORKER despu s de los 30 d as del per odo de tiempo de vigencia de la garant a descrita aqu e Esta garant a tampoco cubre los costos de reparaci n ni reemplazo no autorizados con anterioridad por WATER WORKER Limitaciones adicionales de la garant a TODAS LAS GARANTIAS IMPLICITAS INCLUIDAS TODAS LAS GARANTIAS IMPLICITAS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN PARTICULAR QUEDAN ESPECIFICAMENTE EXCLUIDAS Limitaciones de soluciones LAS SOLUCIONES CONTENIDAS EN ESTA GARANTIA SON LOS RECURSOS EXCLUSIVOS DEL COMPRADOR O PRIMER USUARIO EN NINGUN CASO WATER WORKER SERA RESPONSABLE DE NINGUN MONTO MAYOR AL PRECIO PAGADO POR EL PRODUCTO Y LOS RECURSOS DEL COMPRADOR PRIMER USUARIO NO LO DEBERAN EXCEDER EN NINGUN CASO WATER WORKER SERA RESPONSABLE DE NINGUN DANO ESPECIAL INDIRECTO CASUAL O RESULTANTE YA SEA QUE DERIVE DE LA FALTA DE ENTREGA O DEL USO MAL USO O INCAPACIDAD DE USAR EL PRODUCTO O DE DEFECTOS EN EL PRODUCTO O DE LA PROPIA NEGLIGENCIA DE WATER WORKER U OTRO AGRAVIO Esta exclusi n se aplica independientemente de si dichos da os son buscados para incumplir la garant a incumplir el contrato por negligencia responsabilidad absoluta agravio o de acuerdo a cualquier otra teor a legal Dichos da os incluyen aunque no de forma excluyente inconvenientes p rdidas o da os materiales moho p rdida de beneficios p rdida de ahorros o de ingresos p rdida del uso de los productos o cualquier equipo asociado instalac
9. from the factory Release or add air to adjust the pressure properly If the charge is too high release some air by pressing down on the pin inside the air valve If the charge is too low pump it up using a bicycle tire pump or air compressor Alternatively you can adjust the pressure switch to match the pressure in the tank See instructions on the inside of the cap to the pressure switch for how to do this Step V Turn the power back on The pump will fill the tank The system is now ready to use 1 Open the gate valve to let water flow back into the tank This is the valve that you closed in Step 1 3 See Step 13 for a photo of the gate valve Fig 18 2 Turn on the faucet that is the highest in the house and farthest from the tank This will allow air to exit the system as water enters 3 Turnthe power back on The pump will start and fill the tank Watch for any leaks in the system If you do see a leak turn the power off immediately and repair the leak at the joint It should take 30 seconds to a minute for the pump to prime if itis ajet pump If the pump does not fill the tank and shut off in one minute or so check the pressure gauge If the gauge is moving let the pump continue to run If the gauge is not moving turn the power off This means that the pressure switch is either installed improperly or is defective Check the manufacturer s instructions Replace it if necessary and t
10. neas de vac o y conexiones Luego tape los orificios donde estaban colocados estos dispositivos consulte el manual del usuario para verificar la ubicaci n de los dispositivos Estos dispositivos no son necesarios para los tanques precargados y si no los quita y tapa los orificios puede entrar aire en el sistema de pozo crear sobretensi n da ar el sistema y afectar el rendimiento d Si tiene una bomba de chorro quite los accesorios y tape las aperturas donde las l neas de vac o o aire y los controles del volumen de aire se conectan con la bomba o la tuber a Si no los quita y tapa los orificios puede entrar aire a las tuber as y da ar el sistema de pozo y afectar el rendimiento e Adem s de lo anteriormente mencionado siga los pasos al V 3 Si va a reemplazar un tanque de diafragma o flexible por este tanque de diafragma Water Worker a Silos dos tanques tienen el mismo tama o siga los pasos a V b Si tienen distintos tama os siga los pasos l a V y tambi n ajuste la tuber a seg n corresponda para adaptarla al nuevo tama o 4 Es una buena pr ctica reemplazar el man metro y el interruptor de presi n siempre que reemplace un tanque viejo Por supuesto que puede volver a usar el ensamblaje cruzado del tanque si reemplaza un tanque de diafragma por otro tanque de diafragma incluido el cruce del tanque el man metro el interruptor de presi n la v lvula disipadora la boquilla de la tuber a y el drenaj
11. performance d Si vous avez une pompe jet enlevez les raccords et bouchez les ouvertures l ou la tuyauterie vide ou air comprim et la o les commandes de volume d air se raccordent la pompe ou la tuyauterie S ils ne sont pas enlev s et les trous bouch s cela pourrait permettre l air d entrer dans les tuyaux ce qui pourrait endommager le syst me pour puits et nuire la performance e En plus de ce qui pr c de suivez les tapes V 3 Si vous remplacez un vase d expansion a membrane ou un r servoir vessie avec ce vase d expansion membrane Water Worker a Siles deux r servoirs sont de la m me dimension suivez les tapes V b S ils ne sont pas de la m me dimension suivez les tapes V et ajustez galement la tuyauterie au besoin afin qu elle s adapte la nouvelle dimension 4 C est une bonne pratique de remplacer le manom tre et le manostat lorsque vous remplacez un vieux r servoir Vous pouvez videmment r utiliser le bloc croisillon du r servoir si vous remplacez un vase d expansion membrane avec un autre y compris la croix de r servoir le manometre le manostat la soupape de retour le mamelon pour tuyau et le tuyau d vacuation a Si vous r utilisez le bloc croisillon du r servoir passez l tape Il Dans ce cas assurez vous que le r servoir est install aussi pr s que possible du manostat Cela permettra au syst me de fonctionner aussi effi
12. servoir pour puits de fabrication ASME devrait tre effectu SOUPAPE DE SURPRESSION REQUISE Une soupape de surpression doit tre install e laquelle est configur e pour s ouvrir lors de pressions excessives 75 psi manom triques ou plus Cela prot gera le r servoir pour puits et les autres composants du syst me dans l ventualit d une d fectuosit du manostat laquelle oreviendrait l arr t de la pompe La soupape de surpression doit tre install e au raccord du r servoir pour puits et la tuyauterie et avoir un coulement quivalant la capacit de la pompe 75 psi manom triques Au moins une fois tous les 3 ans ou s il y a pr sence d coulement un entrepreneur licenci devrait v rifier la temp rature et inspecter la soupape de surpression et la remplacer s il y a une pr sence vidente de corrosion ou si elle ne fonctionne pas OMETTRE L INSPECTION DE CETTE SOUPAPE COMME INDIQU POURRAIT R SULTER EN UNE TEMP RATURE D EAU NON S CURITAIRE O UNE ACCUMULATION DE PRESSION CE QUI POURRAIT PROVOQUER LA D FAILLANCE DU PRODUIT DES BLESSURES GRAVES OU LA MORT ET OU DES DOMMAGES MAT RIELS IMPORTANTS ET ANNULERA LA GARANTIE DU PRODUIT Pour votre s curit les informations qui se trouvent WARNING dans ce manuel doivent tre suivies pour r duire le risque de chocs lectriques de dommages mat riels ou de blessures Assurez vous d avoir une mise la terre ad quate et conforme aux codes et aux ord
13. ATER WORKER Productos cubiertos todos los productos fabricados por WATER WORKER WATER WORKER Esta garant a no puede ser transferida se extiende solo al primer usuario o al comprador original del producto Al aceptar y quedarse con este producto usted est de acuerdo con todos los t rminos de la garant a y las limitaciones de responsabilidad descritas a continuaci n ADVERTENCIA IMPORTANTE LEA DETENIDAMENTE EL MANUAL DE INSTALACI N FUNCIONAMIENTO Y MANTENIMIENTO MANUAL para evitar lesiones personales graves o da os materiales y garantizar el uso seguro y el cuidado adecuado del producto Env e por correo su tarjeta de registro del producto dentro de los 30 d as de compra para asegurarse la cobertura de la garant a o se le solicitar un comprobante de compra para todos los reclamos en garant a Qui n recibe la garant a de producto de WATER WORKER Todos los compradores o primeros usuarios del producto nuevo La garant a no es transferible Qu cubre esta garant a WATER WORKER garantiza al comprador o primer usuario del producto nuevo que al momento de la fabricaci n el producto no presenta defectos en el material ni de mano de obra Todo reclamo en garant a se debe realizar dentro de un 1 a o a menos que el manual indique otro per odo de tiempo contado desde el momento en que se compr el producto Qu har WATER WORKER si usted tiene un reclamo que cubre la garant a En caso de incumplimiento de
14. CTRIC CODE AS APPLICABLE TO POTENTIAL PERSONAL INJURY AND OTHER HAZARDS OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL INJURY AS WELL AS PROPERTY DAMAGE THIS IS THE SAFETY ALERT SYMBOL IT IS USED TO ALERT YOU IMPORTANT GENERAL SAFETY INFORMATION ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS AWARNING Failure to utilize a properly sized well tank will result in excessive strain on the pump and may ultimately lead to product failure leaking or flooding or property damage AWARNING For your safety the information in this manual must be followed to minimize the rise of electric shock property damage or personal injury Properly ground to conform with all governing codes and ordinances 1 If you are installing an entirely new well system follow Steps Il Ill IV and V Skip Step since you are not removing an existing tank However make sure that the power is turned off before you hook up the pressure switch to the household wiring If you are in any doubt about working with electricity call a licensed electrician 2 If you are replacing a plain steel tank with this Water Worker diaphragm tank a A diaphragm tank is pressurized with air at the factory at a pressure close to that of a car tire For this reason it will be smaller than the plain steel tank even though both tanks deliver the same amounts of pressurized water Because of this you may have to
15. DE PRESI N O DE TEMPERATURA PELIGROSO QUE PODR A OCASIONAR LA FALLA DEL PRODUCTO LESIONES GRAVES O INCLUSO LA MUERTE O DA OS MATERIALES GRAVES E INVALIDAR LA GARANT A DEL PRODUCTO WARNING Para su seguridad debe seguir la informacion en este manual para minimizar el riesgo de descargas el ctricas lesiones personales o da os materiales Realice la conexi n a tierra adecuada para cumplir con todos los c digos y las normas gubernamentales No use este tanque para qu micos solventes derivados del petr leo cidos ni ning n otro fluido que no sea agua potable Esto puede causar fallas prematuras debido a la corrosi n Aseg rese de que el interruptor de presi n en el sistema de pozo se configure lo suficientemente bajo como para apagar la bomba Si todas las canillas y las v lvulas est n cerradas en el sistema de tuber as y el par metro del interruptor de presi n es muy alto la bomba puede funcionar sin interrupci n sin agua en el sistema Esto puede da ar o quemar la bomba AWARNING ADVERTENCIA PROPOSICI N 65 DE CALIFORNIA Este producto contiene un qu mico que el Estado de California reconoce que es cancer geno y que causa defectos de nacimiento u otros da os reproductivos Instalador contratista de California la ley de California exige que se notifique al consumidor usuario final de este producto Para obtener m s informaci n www waterworkerdiy com prop65 htm 14 GARANTIA LIMITADA DEL PRODUCTO W
16. G una bandeja colectora a un drenaje adecuado en caso M de que la filtraci n o el desbordamiento puedan causar da os materiales al rea adyacente al artefacto o a pisos inferiores de la estructura 6 Instale la v lvula disipadora en la otra apertura roscada hembra en el frente de la barra del tanque Fig 14 Siempre aseg rese IMPORTANT de equipar el sistema de pozo con una v lvula disipadora de presi n adecuada Paso Ill Instale el nuevo ensamblaje cruzado del tanque en el tanque nuevo 1 Quite el tap n pl stico del codo en la parte inferior del tanque Deseche el tap n 2 Instale el ensamblaje cruzado del tanque en el tanque Ya sea que use el ensamblaje cruzado del tanque nuevo o que vuelva a usar el ensamblaje cruzado del tanque viejo col quelo seg n el paso ll antes mencionado Si Aplique cinta Teflon en las roscas en la parte inferior del v stago del cruce del tanque Inserte el v stago en el adaptador roscado hembra en la parte inferior del tanque Ajuste a mano luego con una llave Fig 14 15 12 Paso V Vuelva a encender el suministro el ctrico La bomba llenar el tanque Ahora el sistema est listo para su uso Paso IV Instale el tanque nuevo 1 Instale el tanque nuevo Col quelo donde estaba el tanque viejo o sost ngalo en una posici n para lograr que las tuber as encajen con el cruce del tanque De ser necesario coloque el tanque sobre ladrillo
17. O DE CICLO DE LA BOMBA O EN LA PRESION DE PRECARGA COMPARADA CON EL PAR METRO INICIAL ESTO SE DEBE A QUE LA REDUCCI N EN EL TIEMPO DE CICLO DE LA BOMBA SE PUEDE DEBER A LA P RDIDA DE PRESI N DE AIRE DEL TANQUE QUE A SU VEZ PUEDE SIGNIFICAR QUE EXISTE UNA CORROSI N INTERNA Y TODA REPRESURIZACI N O PRESI N ADICIONAL PUEDE OCASIONAR UNA ROTURA O UNA EXPLOSI N O DA OS MATERIALES AWARNING PRESIONES MAXIMAS DE TRABAJO Cada tanque de pozo se prueba con aire a 125 psig la presi n maxima de trabajo para la linea del tanque de pozo Si las presiones exceden los 125 psig se debe realizar la selecci n adecuada y la calibraci n de un tanque de pozo construido bajo las normas ASME AWARNING VALVULA DISIPADORA REQUERIDA Se debe instalar una valvula disipadora y debe estar configurada para abrirse cuando haya presiones excesivas 75 psig o m s Esto proteger el tanque del pozo y otros componentes del sistema en caso de que el interruptor de presi n funcione mal y no se pueda apagar la bomba La v lvula disipadora se debe instalar en la conexi n del tanque del pozo a la tuber a del sistema y debe tener una descarga igual a la capacidad de la bomba de 75 psig Al menos una vez cada 3 a os o cuando se descargue un contratista autorizado debe inspeccionar la v lvula disipadora de presi n y temperatura y reemplazarla si hubiera corrosi n o no funcionara SI NO SE INSPECCIONA ESTA V LVULA COMO SE INDICA PODR A PRODUCIRSE UN INCREMENTO
18. R WORKER se r serve le droit d apporter des changements la conception la fabrication ou au mat riel du produit ou du composant de remplacement lesquels seront assujettis toutes les conditions et restrictions de cette garantie hormis que la p riode de garantie applicable sera r duite proportionnellement la dur e pendant laquelle le demandeur poss dait le produit avant de soumettre une notification de la r clamation sous garantie WATER WORKER 1400 Division Road West Warwick RI 02893 T l phone 401 884 6300 T l copieur 401 885 2567 www waterworkerdiy com WATERO6 WORKER MANUAL DE INSTALACION PARA LOS TANQUES VERTICALES DEL SISTEMA DE POZO Modelos HT14B HT20B HT30B HT32B HT44B HT62B HT86B y HT119B Guarde este manual con el tanque para referencia en el futuro Lo que necesitara Herramientas recomendadas Llave inglesa Destornillador Pinzas regulables Cinta m trica Llave para tuberias Medidor de presi n de neumaticos Sierra para metales Antes de comenzar Siempre aseg rese de equipar el sistema de pozo con una v lvula disipadora de presi n adecuada Con esto deber a ser posible descargar todo el caudal de la bomba a o por debajo de la presi n de trabajo m xima del componente nominal m s bajo del sistema Consulte el manual del usuario para obtener informaci n sobre el caudal de la bomba Esto es fundamental para el funcionamiento seguro del sistema de pozo Este produc
19. R plus de 30 jours apr s l expiration de la p riode de garantie d crite dans la pr sente garantie e La pr sente garantie ne couvre pas les co ts de r paration ou de remplacement non autoris s l avance par WATER WORKER Restrictions suppl mentaires de garantie TOUTES LES GARANTIES EXPLICITES Y COMPRIS LES GARANTIES EXPLICITES DE QUALITE MARCHANDE ET D APTITUDE POUR UN USAGE PARTICULIER SONT EXPRESSEMENT EXCLUES Restrictions des recours LES RECOURS CONTENUS DANS CETTE GARANTIE SONT LES RECOURS EXCLUSIFS DE L ACHETEUR OU DU PREMIER UTILISATEUR WATER WORKER NE SERA EN AUCUN CAS TENU RESPONSABLE POUR UNE SOMME SUP RIEURE AU PRIX PAY POUR LE PRODUIT ET LES MONTANTS AFF RENTS AUX RECOURS DE L ACHETEUR OU DU PREMIER UTILISATEUR NE POURRONT TRE SUP RIEURS AU PRIX PAY POUR LE PRODUIT WATER WORKER NE SERA EN AUCUN CAS TENU RESPONSABLE POUR TOUT DOMMAGE PARTICULIER INDIRECT ACCESSOIRE OU CONS CUTIF R SULTANT SOIT DE LA NON LIVRAISON DE L UTILISATION DE LA MAUVAISE UTILISATION DU PRODUIT DE L INCAPACIT UTILISER LE PRODUIT DE D FAUTS DANS LE PRODUIT DE LA N GLIGENCE DE WATER WORKER OU DE TOUT AUTRE D LIT Cette exclusion s applique ind pendamment du fait que de tels dommages soient recherch s pour violation de la garantie rupture de contrat n gligence responsabilit sans faute d lit ou en vertu de toute autre th orie juridique De tels dommages comprennent sans y tre limit s les inconv nients la perte
20. SSEMENTS QUI SE TROUVENT DANS LE MANUEL POURRAIT CAUSER DES BLESSURES GRAVES OU LA MORT ET OU DES DOMMAGES MATERIELS ET ANNULERA LA GARANTIE DU PRODUIT CE PRODUIT DOIT ETRE INSTALLE PAR UN PROFESSIONNEL QUALIFI SUIVEZ TOUS LES CODES ET REGLEMENTS LOCAUX ET PROVINCIAUX APPLICABLES EN L ABSENCE DE TELS CODES SUIVEZ L EDITION COURANTE DU CODE NATIONAL ELECTRIQUE ET DE LA PLOMBERIE SI APPLICABLE VAN CELA EST LE SYMBOLE D ALERTE DE S CURIT IL EST UTILIS POUR VOUS AVISER DES DANGERS POTENTIELS DE BLESSURES ET AUTRES RESPECTEZ TOUS LES MESSAGES DE SECURITE INDIQUES APRES CE SYMBOLE POUR REDUIRE LE RISQUE DE BLESSURES ET DE DOMMAGES MATERIELS INFORMATIONS IMPORTANTES DE S CURIT G N RALE DES AVERTISSEMENTS SUPPL MENTAIRES PR CIS APPARAISSENT DANS LES INSTRUCTIONS SUIVANTES WARNING Omettre d utiliser Un r servoir pour puits de bonne dimension provoquera une contrainte excessive sur la pompe et pourrait ventuellement provoquer une d faillance une fuite ou une inondation ou des dommages mat riels WARNING Pour votre s curit les informations qui se trouvent dans ce manuel doivent tre suivies pour r duire le risque de chocs lectriques de dommages mat riels ou de blessures Assurez vous d avoir une mise la terre ad quate et conforme aux codes et aux ordonnances 1 Si vous installez un tout nouveau syst me suivez les tapes Il Ill IV et V Sautez l tape puisque vous n enlevez pas un r servoir
21. WATERO6 WORKER INSTALLATION MANUAL FOR VERTICAL WELL SYSTEM TANKS Models HT14B HT20B HT30B HT32B HT44B HT62B HT86B and HT119B Keep this manual with the tank for future reference What You ll Need Recommended Tools Adjustable Wrench Adjustable Pliers Pipe Wrench Additional Parts Required Not Included Tank Water Connection Size 1 NPTF Pressure Gauge Relief Valve Check Valve Screwdriver Drain Valve Pressure Switch Tank Cross 10 Lx1 NPTM Teflon Tape Tape Measure Tire Pressure Gauge Hacksaw Before You Start Always be sure to equip your well system with a proper Pressure Relief Valve This should be capable of discharging the full output of the pump at or below the maximum working pressure of the lowest rated component in the system See the owner s manual for your pump for output information This is vital for safe operation of the well system THIS PRODUCT COMES WITH A 5 YEAR WARRANTY SEE WATER WORKER LIMITED WARRANTY FOR DETAILS AWARNING READ CAREFULLY THE PRODUCT INSTALLATION OPERATING AND MAINTENANCE MANUAL FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE MANUAL MAY RESULT IN SERIOUS OR FATAL INJURY AND OR PROPERTY DAMAGE AND WILL VOID THE PRODUCT WARRANTY THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED PROFESSIONAL FOLLOW ALL APPLICABLE LOCAL AND STATE CODES AND REGULATIONS IN THE ABSENCE OF SUCH CODES FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND NATIONAL ELE
22. a 5 Quite la tapa de pl stico de la v lvula en un minuto m s o menos controle de aire en la parte superior del tanque Controle la carga de aire en el tanque con el medidor de presi n de neum ticos Ajuste la presi n de precarga en el tanque para que est entre 1 y 2 psi por debajo del par metro de reducci n de la bomba del interruptor de presi n Primero mire dentro de la tapa hacia el interruptor de presi n para determinar el par metro de reducci n de la bomba Deber a decir 20 40 o 30 50 o similar La presi n del tanque se debe ajustar a 2 psi por debajo de la presi n inferior de estos dos n meros Es decir la presi n del tanque debe configurarse aproximadamente a 18 psi si la tapa indica un par metro de reducci n de 20 40 o a 28 si la tapa indica un par metro de 30 50 La tabla Muestra A indica la carga de aire en el tanque cuando el tanque se env a de f brica Libere o agregue aire para ajustar la presi n de forma adecuada Si la carga es demasiado alta libere una parte del aire presionando hacia abajo el perno dentro de la v lvula de aire Si la carga es demasiado baja cargue el tanque con una bomba para neum ticos de bicicleta o un compresor de aire Tambi n puede ajustar el interruptor de presi n para que coincida con la presi n en el tanque Lea las instrucciones dentro de la tapa del interruptor de presi n para saber c mo hacer esto 13 el man met
23. ada Ya sea que vuelva a usar el ensamblaje cruzado del tanque o haya montando uno nuevo aseg rese de que el ensamblaje incluya una v lvula disipadora que pueda descargar todo el caudal de la bomba a o por debajo de la presi n de trabajo m xima del componente nominal m s bajo en el sistema Consulte el manual del usuario para obtener informaci n sobre el caudal de la bomba Esto es fundamental para el funcionamiento seguro del sistema Como instalar el tanque Paso Desconecte y retire el tanque existente despu s de apagar el suministro el ctrico y de drenar el sistema 1 Encuentre el panel del disyuntor o de la caja de fusibles de su casa Apague el suministro el ctrico de la bomba del pozo Para su seguridad A WARNING debe seguir la informacion en este manual para minimizar el riesgo de descargas el ctricas lesiones personales o da os materiales Realice la conexi n a tierra adecuada para cumplir con todos los c digos y las normas gubernamentales Abra una canilla dentro la casa Drene el sistema todo lo que sea posible dejando correr el agua hasta que se termine Cierre la v lvula de bola o esclusa esta es la v lvula que controla el flujo de agua del tanque hacia el sistema de tuber as de la casa Fig 1 Drene el agua restante del tanque con una manguera de jard n en un balde o en el drenaje del suelo Coloque una manguera de jard n en la canilla al frente del cruce del tanque Coloque el
24. bordement d eau chaude dans un syst me de chauffage eau chaude Consultez le manuel du propri taire de votre pompe pour l information de sortie WARNING RISQUE D EXPLOSION OU DE RUPTURE Une soupape de surpression doit tre install e pour pr venir un exc s de pression conform ment au code local ou selon la pression de service maximale d sign e dans le manuel du produit celui qui est le moins lev N exposez pas le produit des temp ratures de gel ou sup rieures 93 33 C 200 F N ajustez pas la pr charge ou ne repressurisez pas ce produit moins d avoir besoin d effectuer des ajustements lors de l installation initiale et surtout si le produit est corrod endommag ou pr sente une int grit r duite Les ajustements la pr charge doivent tre faits uniquement a la temp rature ambiante Omettre d avoir la bonne dimension de produit ou de suivre ces instructions pourrait provoquer une contrainte excessive sur le syst me et pourrait provoquer une d faillance du produit des blessures graves ou la mort une fuite et ou des dommages mat riels WARNING Ce produit comme la plupart des produits sous pression peut se corroder avec le temps II peut s affaiblir et clater ou exploser causant des blessures graves ou la mort une fuite et ou des dommages mat riels Pour r duire ce risque un professionnel qualifi doit installer inspecter et effectuer l entretien p riodique du produit Un bac r cepteur
25. butor or retailer more than 30 days after expiration of the applicable warranty time period described in this Warranty e this Warranty also does not cover repair or replacement costs not authorized in advance by WATER WORKER Additional Warranty Limitations ALL IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE SPECIFICALLY DISCLAIMED Limitations of Remedies THE REMEDIES CONTAINED IN THIS WARRANTY ARE THE PURCHASER S OR FIRST USER S EXCLUSIVE REMEDIES IN NO CIRCUMSTANCES WILL WATER WORKER BE LIABLE FOR MORE THAN AND PURCHASER FIRST USER S REMEDIES SHALL NOT EXCEED THE PRICE PAID FOR THE PRODUCT IN NO CASE SHALL WATER WORKER BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER RESULTING FROM NON DELIVERY OR FROM THE USE MISUSE OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM WATER WORKER S OWN NEGLIGENCE OR OTHER TORT This exclusion applies regardless of whether such damages are sought for breach of warranty breach of contract negligence strict liability in tort or under any other legal theory Such damages include but are not limited to inconvenience loss or damage to property mold loss of profits loss of savings or revenue loss of use of the Products or any associated equipment facilities buildings or services downtime and the claims of third parties including customers What To Do If You Have a Problem Covere
26. cace que possible b Si vous remplacez le bloc croisillon du r servoir avec de nouvelles pi ces lors de l installation du nouveau r servoir effectuez toutes les tapes dans ces instructions tapes V WARNING SOUPAPE DE SURPRESSION REQUISE Une soupape de surpression doit tre install e laquelle est configur e pour s ouvrir lors de pressions excessives 75 psi manom triques ou plus Cela protegera le r servoir pour puits et les autres composants du syst me dans l ventualit d une d fectuosit du manostat laquelle pr viendrait l arr t de la pompe La soupape de surpression doit tre install e au raccord du r servoir pour puits et la tuyauterie et avoir un coulement quivalant la capacit de la pompe 75 psi manom triques Au moins une fois tous les 3 ans ou s il y a pr sence d coulement un entrepreneur licenci devrait v rifier la temp rature et inspecter la soupape de surpression et la remplacer s il y a une pr sence vidente de corrosion ou si elle ne fonctionne pas OMETTRE L INSPECTION DE CETTE SOUPAPE COMME INDIQUE POURRAIT RESULTER EN UNE TEMPERATURE D EAU NON S CURITAIRE OU UNE ACCUMULATION DE PRESSION CE QUI POURRAIT PROVOQUER LA D FAILLANCE DU PRODUIT DES BLESSURES GRAVES O LA MORT ET OU DES DOMMAGES MAT RIELS IMPORTANTS ET ANNULERA LA GARANTIE DU PRODUIT 5 Assurez vous de toujours quiper ad quatement votre syst me pour puits avec une bonne soupape de surpression Que
27. connect a un drain ad quat doit tre install s il y a un risque qu une fuite ou qu une inondation cause des dommages mat riels N effectuez pas cette installation dans un endroit ou une fuite du systeme ou des raccords pourraient causer des dommages mat riels a la zone adjacente a l appareil ou aux tages inf rieurs de l immeuble Chlore et eau agressive la qualit de l eau peut WARNING influencer de mani re importante la dur e de vie de ce produit Vous devriez la tester afin d y d tecter la pr sence possible d l ments corrosifs d acidit de mati res solides totales et d autres contaminants pertinents y compris le chlore et traitez votre eau ad quatement pour vous assurer d un rendement satisfaisant et pour pr venir une d faillance pr matur e Remarque inspectez l appareil pour des dommages encourus lors de l exp dition Si vous constatez des dommages avisez imm diatement le transporteur ou le magasin o l achat a t effectu Si le produit pr sente des signes de d fectuosit ou de corrosion veuillez appeler imm diatement un professionnel qualifi afin d viter tout risque de blessures et de dommages mat riels Des exemplaires courants du manuel du produit peuvent tre visualis s au www waterworkerdiy com Utilisez un quipement de s curit appropri lors de l installation Comme avec tous les produits de plomberie et de A CAUTION reservoirs de stockage d eau les bact ries peuvent y p
28. d By This Warranty Any covered Warranty service must be authorized by WATER WORKER Contact the person from whom you purchased the Product who must receive authorization from a WATER WORKER distributor or WATER WORKER If you do not receive a prompt response call WATER WORKER directly at 877 324 8863 Notice of a Warranty claim should be submitted by the authorized distributor for WATER WORKER at the following address WATER WORKER Warranty Claim Dept 1400 Division Road West Warwick RI 02893 Before WATER WORKER determines to provide any replacement part or Product it may as a pre condition to making such a determination require that the warranty claimant ship the Product postage prepaid to an authorized WATER WORKER distributor or to WATER WORKER and provide proof of purchase evidenced by the original sales receipt or Product registration Replacement Product Warranty In case of replacement of a Product or any component part WATER WORKER reserves the right to make changes in the design construction or material of the substitute components or products which shall be subject to all of the terms and limitations of this Warranty except that the applicable warranty periods shall be reduced by the amount of time the warranty claimant owned the product prior to submitting notification of the warranty claim WATER b WORKER 1400 Division Road West Warwick RI 02893 T 401 884 6300 F 401 885 2567 www waterworkerdiy com B Part
29. e a Si vuelve a usar el ensamblaje cruzado del tanque omita el paso ll En este caso aseg rese de que el tanque se instale lo m s cerca posible del interruptor de presi n Esto har que el sistema funcione con la mayor eficacia posible b Si reemplaza el ensamblaje cruzado del tanque con piezas nuevas cuando instala el tanque nuevo complete todos los pasos de las instrucciones pasos al V AWARNING VALVULA DISIPADORA REQUERIDA Se debe instalar una v lvula disipadora y debe estar configurada para abrirse cuando haya presiones excesivas 75 psig o m s Esto proteger el tanque del pozo y otros componentes del sistema en caso de que el interruptor de presi n funcione mal y no se pueda apagar la bomba La v lvula disipadora se debe instalar en la conexi n del tanque del pozo a la tuber a del sistema y debe tener una descarga igual a la capacidad de la bomba de 75 psig Al menos una vez cada 3 a os o cuando se descargue un contratista autorizado debe inspeccionar la v lvula disipadora de presi n y temperatura y reemplazarla si hubiera corrosi n o no funcionara SI NO SE INSPECCIONA ESTA V LVULA COMO SE INDICA PODR A PRODUCIRSE UN INCREMENTO DE PRESI N O DE TEMPERATURA PELIGROSO QUE PODR A OCASIONAR LA FALLA DEL PRODUCTO LESIONES GRAVES O INCLUSO LA MUERTE O DA OS MATERIALES GRAVES E INVALIDAR LA GARANT A DEL PRODUCTO 5 Siempre aseg rese de equipar el sistema de pozo con una v lvula disipadora de presi n adecu
30. e the pipes meet the tank cross If necessary place the tank on garden bricks or cinder blocks to make sure that it stands at the right height Connect the tank to the pump supply lines using piping to fit Follow all applicable local and state codes and ordinances Note Do not place the tank where it or the controls on it will freeze This can damage the system 2 Screw the pipe unions hand tight first then tighten wrench tight using the pipe wrench a 3 Re install the wires in the pressure switch Attach the leads to the connections as you marked them Fig 16 4 Replace the cover to the pressure switch Check to make sure that the standard drain boiler drain valve is closed Fig 17 5 Remove the plastic cap on the air valve on top of the tank Check the air charge in the tank using the tire pressure gauge Adjust the precharge pressure in the tank to be 1 to 2 psi below the pressure switch pump cut in setting First look inside the cap to the pressure switch to determine gf the pump cut in setting It should zh say 20 40 or 30 50 or the like W The pressure in the tank should be adjusted to be 2 psi below the lower of these two numbers That is the tank pressure should be set hi at about 18 psi if the cap indicates a cut in setting of 20 40 or set at about 28 if the cap indicates a setting of 30 50 The table Exhibit A indicates the air charge in the tank when the tank is shipped
31. est the system again to see that it is installed properly 4 Turn a faucet on nearby to check that the system is working correctly EXHIBIT A VERTICAL TANKS MODEL NO PRECHARGE PRESSURE HT14B HT20B HT30B HT32B HT44B 38 psi HT62B 38psi HT86B 38psi J HTN9B 38 psi r EVORA AA AAA 17 18 IMPORTANT Safety Instructions Be sure to read This tank is designed for use with potable AA IMPORTANT water limited to a maximum pressure of 100 psi and a maximum working temperature of 130 F Please note a hot water heater or a boiler in a hydronic heating system will heat water hotter than 130 F routinely Use a thermal expansion tank for hot water overflow from a hot water heater or use an expansion tank for hot water overflow in a hydronic heating system See the owner s manual for your pump for output information EXPLOSION OR RUPTURE HAZARD A relief WARNING valve must be installed to prevent pressure in excess of local code requirement or maximum working pressure designated in the Product Manual whichever is less Do not expose Product to freezing temperatures or temperatures in excess Of 200 F Do not adjust the pre charge or re pressure this Product except for any adjustments required at the time of initial installation especially if Product corroded damaged or with diminished integrity Adjustments to pre charge must be done at ambient temperature only Fai
32. existant Cependant assurez vous que l alimentation lectrique est coup e avant de brancher le manostat au c blage lectrique de votre maison Si vous avez des doutes travailler avec l lectricit appelez un lectricien qualifi 2 Si vous remplacez un r servoir en acier noir avec ce vase d expansion membrane Water Worker a Un vase d expansion membrane est pressuris avec de l air en usine une pression similaire celle utilis e dans un pneu d automobile C est la raison pour laquelle il sera plus petit qu un r servoir en acier noir et ce m me si les deux r servoirs distribuent la m me quantit d eau sous pression Pour cette raison vous aurez peut tre modifier la tuyauterie de fa on rejoindre les nouvelles connexions b Installez une soupape de surpression au niveau de la connexion du r servoir afin d assurer la s curit du syst me c Si vous avez une pompe submersible pour puits profond retirez tous les dispositifs d alimentation en air du syst me pour puits reniflards valves prise de gaz tuyauterie vide et connexions Puis bouchez les trous o ces dispositifs se trouvaient consultez votre manuel du propri taire pour leur emplacement Ces dispositifs ne sont pas n cessaires pour les 6 r servoirs pr charg s et s ils ne sont pas enlev s et les trous bouch s l air pourrait s infiltrer dans le syst me et causer des surpressions des dommages au syst me et nuire sa
33. iones edificaciones o servicios tiempo de inactividad y los reclamos de terceros incluidos los clientes Qu hacer si tiene un problema que cubre esta garant a Todo servicio cubierto por la garant a debe ser autorizado por WATER WORKER Comun quese con el vendedor del producto quien debe recibir autorizaci n de un distribuidor de WATER WORKER o de WATER WORKER Si no recibe una pronta respuesta llame directamente a WATER WORKER al 877 324 8863 El distribuidor autorizado de WATER WORKER debe enviar el aviso de reclamo en garant a a WATER WORKER al siguiente domicilio WATER WORKER Warranty Claim Dept 1400 Division Road West Warwick RI 02893 Antes de que WATER WORKER determine si proporciona la pieza de repuesto o el producto puede como precondici n para tomar dicha determinaci n solicitar que el demandante de la garant a env e el producto con franqueo postal pagado a un distribuidor de WATER WORKER autorizado o a WATER WORKER y proporcione un comprobante de compra ya sea el recibo de venta original o el registro del producto Garant a de reemplazo del producto En caso de que se reemplace el producto o cualquier componente WATER WORKER se reserva el derecho de realizar cambios en el dise o construcci n o material de los componentes o productos sustitutos que estar n sujetos a todos los t rminos y las limitaciones de esta garant a excepto que los per odos de la garant a vigente fueran reducidos a la cantidad de tiem
34. ions de responsabilit s indiqu es ci dessous AVERTISSEMENT IMPORTANT VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS DU MANUEL D INSTALLATION DE FONCTIONNEMENT ET D ENTRETIEN MANUEL pour viter des blessures graves et ou des dommages mat riels et pour vous assurer d une utilisation s curitaire et du bon entretien de ce produit Postez votre carte d enregistrement du produit dans les 30 jours suivant l achat pour assurer votre couverture de garantie Dans le cas contraire une preuve d achat sera requise pour chaque r clamation sous garantie Qui re oit la garantie du produit WATER WORKER Tous les acheteurs ou les premiers utilisateurs du nouveau produit Cette garantie n est pas transf rable Qu est ce qui est couvert par cette garantie WATER WORKER garantit l acheteur ou au premier utilisateur du nouveau produit qu au moment de la fabrication le produit est sans d fectuosit mat rielle ou de main d oeuvre Toute r clamation sous garantie doit tre soumise dans un d lai d un 1 an moins qu une autre p riode de temps soit nonc e dans le manuel partir de la date laquelle le produit a t achet Ce que WATER WORKER fera si vous avez une r clamation couverte sous garantie Dans l ventualit du non respect de la pr sente garantie WATER WORKER va sa discr tion soit effectuer des r parations pour corriger toute d fectuosit mat rielle ou de main d oeuvre soit fournir et livrer des pi ces ou de
35. l known by the State of California to cause cancer and to cause birth defects or other reproductive harm California Installer Contractor California law requires that this notice be given to consumer end user of this product For more information www waterworkerdiy com prop65 htm WATER WORKER LIMITED PRODUCT WARRANTY Products covered all Products manufactured by WATER WORKER WATER WORKER This warranty cannot be transferred it is extended only to the original Purchaser or First User of the Product By accepting and keeping this Product you agree to all of the warranty terms and limitations of liability described below IMPORTANT WARNING READ CAREFULLY THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL MANUAL to avoid serious personal injury and or property damage and to ensure safe use and proper care of this product Mail Your Product Registration Card Within 30 Days of Purchase to Ensure Your Warranty Coverage or Proof of Purchase Will Be Required for All Warranty Claims Who Receives WATER WORKER s Product Warranty All purchasers or first users of the new Product The Warranty is non transferable What is covered by this Warranty WATER WORKER warrants to the purchaser or first user of the new Product that at the time of manufacture the Product is free from defects in material and workmanship Any warranty claim must be made within one 1 year unless another time period is set forth in the Ma
36. la presente garant a WATER WORKER si lo desea puede hacer reparaciones para corregir cualquier defecto en el material o de la mano de obra o suministrar y enviar ya sean piezas de repuesto o productos nuevos o usados WATER WORKER no aceptar ning n reclamo por mano de obra u otros costos Qu no cubre este garant a exclusiones y limitaciones Esta garant a no cubre ninguna falla o problema a menos que haya sido causado por un defecto en el material o en la mano de obra Adem s esta garant a no tendr validez e Si el producto no est bien instalado operado reparado o mantenido seg n las indicaciones del Manual provisto con el producto e Para ninguna falla o disfunci n causada por el uso incorrecto incluido el congelamiento inadecuado o negligente manipulaci n transporte que no sea por WATER WORKER almacenamiento uso funcionamiento accidente o alteraci n rayo inundaci n o cualquier otra condici n ambiental e Para ninguna falla o problema causado por el uso del producto para un fin que no sea el especificado en el Manual correspondiente o por la alteraci n de cualquiera de las partes del producto e Esta garant a no cubre costos de mano de obra cargos por transporte cargos por servicio t cnico gastos de entrega pagos administrativos ni ning n costo correspondiente a la remoci n o reinstalaci n del producto e Esta garant a no cubre ning n reclamo enviado a WATER WORKER un minorista o un distribuidor autorizado
37. lure to properly size the Product or follow these instructions may result in excessive strain on the system lead to Product failure serious or fatal personal injury leakage and or property damage This Product like most Products under WARNING pressure may over time corrode Weaken and burst or explode causing serious or fatal injury leaking or flooding and or property damage To minimize risk a licensed professional must install and periodically inspect and service the Product A drip pan connected to an adequate drain must be installed if leaking or flooding could cause property damage Do not locate in an area where leakage of the tank or connections could cause property damage to the area adjacent to the appliance or to lower floors of the structure Chlorine amp Aggressive Water The water WARNING quality can significantly influence the life of this Product You should test for corrosive elements acidity total solids and other relevant contaminants including chlorine and treat your Water appropriately to insure satisfactory performance and prevent premature failure Note Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present To avoid risk of personal injury and property damage if the product appears to be malfunctioning or shows signs of corrosion call a qualified professional immediately Current copies of the Product manual can be viewed at www waterworkerdiy
38. mblez le nouveau bloc croisillon du r servoir REMARQUE si vous r utilisez le bloc croisillon de l ancien r servoir passez l tape Ill 1 Si vous utilisez de nouvelles pi ces pour le bloc croisillon du nouveau r servoir d ballez la croix du r servoir le manom tre le manostat la soupape de surpression et le mamelon pour tuyau de leur emballage Assemblez le bloc croisillon du r servoir Appliquez DU RUBAN Teflon au filetage m le sur le manometre de la croix du r servoir et aux deux extr mit s du mamelon pour tuyau Fig 10 Appliquez dans le sens des aiguilles d une montre c est dire le bas vers le haut et vers vous Appliquez 3 tours complets 2 Ins rez le mamelon pour tuyau dans l un des trous sur le dessus du croisillon de la croix du r servoir Peu importe lequel vous s lectionnez Serrez en utilisant la cl tuyau Fig 11 3 Ins rez le manom tre dans l autre trou sur le dessus du croisillon Serrez avec la cl ajustable sur les crous en laiton carr s Serrez manuellement puis avec la cl Ne serrez pas trop Le ruban Teflon assurera une tanch it suffisante Une fois serr ne desserrez pas Si vous le faites le joint est plus susceptible de fuir Fig 12 4 Installez le manostat sur le dessus du mamelon pour tuyau Serrez avec la cl ajustable sur l crou en laiton hexagonal Serrez manuellement Puis avec la cl 5 Installezletuyaud vacuation
39. mplir con todos los c digos y las normas gubernamentales 1 Si va a instalar un sistema de pozo completamente nuevo siga los pasos Ill Ill IV y V Omita el paso ya que no va retirar un tanque existente Sin embargo aseg rese de que el suministro el ctrico est apagado antes de conectar el interruptor de presi n a las conexiones el ctricas de la casa Si tiene alguna duda sobre el trabajo con la electricidad llame a un profesional autorizado 2 Si va a reemplazar un tanque de acero plano por un tanque de diafragma Water Worker a Un tanque de diafragma est presurizado con aire desde f brica a una presi n similar a la de la de un neum tico de auto Es por esto que ser menor al tanque de acero plano aunque ambos tanques proporcionen la misma cantidad de agua presurizada Por eso es posible que tenga que ajustar la tuber a para alcanzar las conexiones nuevas b Instale una v lvula disipadora en la conexi n del tanque para garantizar la seguridad del sistema c Si tiene una bomba sumergible de pozo profundo quite todos los dispositivos de carga de aire desde el sistema de pozo v lvulas de 11 Piezas adicionales requeridas no incluidas Tama o de conexi n del tanque de agua de 1 NPTF rosca para tubos V lvula de drenaje Interruptor de presi n Cruce del tanque 10 Lx1 NPTM Cinta Teflon Man metro V lvula disipadora V lvula de retenci n descarga orificios divisores de tensi n l
40. n the drain tighten using the adjustable valve and drain the water out of wrench on the hexagonal brass the tank It may be necessary nut Tighten hand tight Then to vent the tank through the wrench alt air valve to allow the tank to Sue A 2 5 Install drain on the arm of the R bar of the tank cross Tighten 5 Disconnect the wiring to the ee pressure switch Check first to using pipe wrench Fig 13 be sure that the power to the A die sl pump is turned off AWARNING ee to an adequate drain must be a sear a R ead pes installed if leaking or flooding adjustable Senco De by could cause property damage to hand Fig 3 the area adjacent to the appliance O or to lower floors of the structure D the cap to the pressure 6 Install the pressure relief valve in the other female threaded opening on the front of the cross c Unscrew the connections for the bar of the tank Fig 14 wires Always be sure d Mark which wire goes to which AX IMPORTANT to equip your screw on the pressure switch i e well system with a proper note that the green wire connects pressure relief valve to the front screw mark using masking tape if necessary Fig 4 Step lll Install the new tank cross assembly on the new tank e Unscrew the clamp connector holding the wiring to the pressure 1 Remove the plastic plug from the switch Fig 5 elbow at the bottom of the tank Discard the plug f Pull the wires out of the pressure id switch Fig 6 2
41. nk with another diaphragm tank Cincluding the tank cross pressure gauge pressure switch pressure relief valve pipe nipple and drain a If you do re use a tank cross assembly skip Step Il In this case make sure that the tank is installed as closely as possible to the oressure switch This will make the system operate as efficiently as possible b If you replace the tank cross assembly with new parts when you install the new tank complete all of the steps in these instructions Steps through V RELIEF VALVE REQUIRED A relief valve should WARNING be installed which is set to open at excessive pressures 75 psig or more This will protect the well tank and other system components should the pressure switch malfunction and fail to shut the pump off The relief valve should be installed at the connection of the well tank to the system piping and have a discharge equal to the pump s capacity at 75 psig At least once every 3 years or if discharge is present a licensed contractor should inspect the temperature and pressure relief valve and replace if corrosion is evident or the valve does not function FAILURE TO INSPECT THIS VALVE AS DIRECTED COULD RESULT IN UNSAFE TEMPERATURE OR PRESSURE BUILD UP WHICH CAN RESULT IN PRODUCT FAILURE SERIOUS INJURY OR DEATH AND OR SEVERE PROPERTY DAMAGE AND VOID THE PRODUCT WARRANTY 5 Always make sure that you equip your well system with an appropriate pressure relief valve Whether you are re
42. nual measured from the time the Product was purchased What WATER WORKER Will Do If You Have a Covered Warranty Claim In the event of a breach of the foregoing warranty WATER WORKER will at its option either make repairs to correct any defect in material or workmanship or supply and ship either new or used replacement parts or products WATER WORKER will not accept any claims for labor or other costs What This Warranty Does Not Cover Exclusions and Limitations This Warranty does not cover any failure or problem unless it was caused by a defect in material or workmanship In addition this Warranty shall not apply e if the Product is not correctly installed operated repaired or maintained as described in the Manual provided with the Product e to any failure or malfunction resulting from abuse including freezing improper or negligent handling shipping by anyone other than WATER WORKER storage use operation accident or alteration lightning flood or any other environmental condition e to any failure or problem resulting from the use of the Product for any purpose other than those specified in the accompanying Manual or alteration of any part of the product e this Warranty does not cover labor costs shipping charges service charges delivery expenses administrative fees or any costs incurred in removing or reinstalling the Product e this Warranty does not cover any claims submitted to WATER WORKER or a WATER WORKER authorized distri
43. o del tanque viejo vaya al paso Ill 1 Si usa piezas nuevas para el ensamblaje cruzado del tanque saque el cruce del tanque el man metro el interruptor de presi n la v lvula disipadora y la boquilla de la tuber a nueva de sus embalajes Monte la unidad cruzada del tanque nuevo Aplique cinta Teflon a las roscas macho en el man metro del cruce del tanque y en ambos extremos de la boquilla de la tuber a Fig 10 Apl quela en el sentido de las agujas del reloj es decir parte inferior hacia arriba y hacia usted Aplique 3 vueltas completas 2 Inserte la boquilla de la tuberia en uno de los orificios en la parte superior de la barra del cruce del tanque No importa cu l Ajuste con la llave inglesa Fig 11 3 Inserte el man metro en el otro orificio en la parte superior de la barra Ajuste la tuerca de lat n cuadrada con la llave inglesa Ajuste a mano luego con una llave No ajuste demasiado La cinta Teflon garantizar un sellado suficiente Una vez ajustado no lo afloje Si lo hace es m s probable que haya filtraciones en las juntas Fig 12 4 Instale el interruptor de presi n en la parte superior de la boquilla de la tuber a Una vez m s ajuste la tuerca de lat n hexagonal con la llave inglesa Aj stela a mano Luego ajuste con la llave 5 Instale un drenaje en el brazo de la barra del cruce del tanque Aj stelo con la llave inglesa Fig 13 Se debe instalar WARNIN
44. onnances N utilisez pas ce r servoir pour des produits chimiques des solvants des produits p troliers des acides ou tout liquide autre que l eau potable Cela pourrait entra ner une d faillance pr matur e due la corrosion Assurez vous que le manostat l int rieur de votre syst me pour puits soit r gl assez bas pour arr ter la pompe Si tous les robinets et les soupapes de votre plomberie sont ferm s et que le r glage du manostat est trop lev la pompe peut fonctionner continuellement sans faire passer l eau dans le syst me Cela pourrait endommager o griller la pompe WARNING AVERTISSEMENT AFF RENTE LA PROPOSITION 65 DE LA CALIFORNIE D apr s l tat de la Californie ce produit contient des substances chimiques susceptibles d tre canc rig nes de causer des anomalies cong nitales ou d autres probl mes reproductifs Installateur entrepreneur de la Californie la loi de la Californie exige que cet avis soit donn aux consommateurs utilisateurs de ce produit Pour de plus amples renseignement www waterworkerdiy com prop65 htm GARANTIE LIMITEE DU PRODUIT WATER WORKER Produits couverts tous les produits fabriqu s par WATER WORKER WATER WORKER Cette garantie ne peut pas tre transf r e elle s applique uniquement au premier acheteur ou le premier utilisateur du produit En acceptant et en gardant ce produit vous acceptez toutes les conditions de la garantie et les restrict
45. os acidez s lidos totales y otros contaminantes relevantes incluido el cloro y tratar el agua de manera adecuada para garantizar un rendimiento satisfactorio y prevenir las fallas prematuras Nota Inspeccione si hay da os debidos al transporte de ser as notifique al transportista o al comercio donde lo compr de inmediato Para evitar el riesgo de lesiones personales y da os materiales si el producto parece funcionar mal o muestra signos de corrosi n llame a un profesional calificado de inmediato Las copias actualizadas del Manual del producto se pueden encontrar en www waterworkerdiy ccom Use el equipo de seguridad adecuado cuando realice la instalaci n CAUTION Como en todos los productos de plomeria y en los contenedores para el almacenamiento de agua pueden crecer bacterias en este producto en especial mientras no esta en uso Consulte a su plomero profesional local acerca de los pasos que puede tomar para desinfectar de forma segura el sistema de tuberias de su hogar PELIGRO PELIGRO DE EXPLOSION SI SE HA WARNING REALIZADO EL SERVICIO T CNICO AL TANQUE DE POZO Y ES NECESARIO CAMBIAR A UNA PRESION DE PRECARGA MAS ALTA DEBIDO A UN CAMBIO REQUERIDO EN EL PARAMETRO DEL INTERRUPTOR DE PRESION SI NO SIGUE EL MANUAL DE INSTRUCCIONES PUEDE OCASIONAR UNA ROTURA O UNA EXPLOSION QUE POSIBLEMENTE CAUSEN LESIONES GRAVES O MORTALES O DANOS MATERIALES NO AJUSTE LA PRESION DE PRECARGA SI HUBO UNA REDUCCION EN EL TIEMP
46. otro extremo de la manguera en un balde para que est a un nivel inferior que la canilla Abra la v lvula de drenaje y drene el agua hacia afuera del tanque Puede ser necesario ventilar el tanque con la v lvula de aire para dejar que se drene por completo Fig 2 Desconecte la conexi n el ctrica del interruptor de presi n Primero aseg rese de que el suministro el ctrico a la bomba este apagado Afloje la tuerca hexagonal en la parte superior de la tapa con pinzas o con la llave inglesa Desenrosque a mano Fig 3 Quite la tapa del interruptor de presi n Desenrosque las conexiones de los cables Marque qu cable va con qu tornillo en el interruptor de presi n es decir tenga en cuenta que el cable verde se conecta al tornillo frontal de ser necesario m rquelo con cinta de enmascarar Fig 4 Desenrosque el conector de la abrazadera que sostiene la conexi n el ctrica al interruptor de presi n Fig 5 Saque los cables del interruptor de presi n Fig 6 Afloje y desenrosque las conexiones de uni n que sostienen el tanque y el conjunto del cruce del tanque man metro interruptor de presi n en su lugar Fig 7 8 Coloque el tanque de costado con el cruce del tanque apuntando hacia arriba Quite el ensamblaje cruzado del tanque desenrosc ndolo con la llave para tuber as Fig 9 Paso Il Monte la unidad cruzada del tanque nuevo NOTA Si vuelve a usar el ensamblaje cruzad
47. ou les dommages la propri t la moisissure la perte de profits la perte d pargne ou de revenu la perte de l utilisation des produits ou tout autre quipement associ d installations de b timents ou services les temps d arr t et les r clamations des tierces parties y compris les clients Que faire si vous avez un probl me couvert par cette garantie Tout service couvert par la garantie doit tre autoris par WATER WORKER Contactez la personne qui vous avez achet le produit lequel doit recevoir l autorisation d un distributeur WATER WORKER ou de WATER WORKER Si vous n obtenez pas une r ponse rapide veuillez contacter directement WATER WORKER au 877 324 8863 Un avis de r clamation sous garantie devrait tre soumis par le distributeur autoris WATER WORKER l adresse suivante WATER WORKER d partement de r clamation sous garantie 1400 Division Road West Warwick RI 02893 Avant que WATER WORKER prenne une d cision quant fournir tout pi ce ou produit de remplacement il peut en tant que condition pr alable la prise d une telle d cision exiger que le demandeur de la r clamation sous garantie exp die le produit par port pr pay un distributeur autoris WATER WORKER ou a WATER WORKER et de fournir la preuve d achat attest e par la facture de vente d origine ou par l enregistrement du produit Garantie de remplacement du produit En cas de remplacement d un produit ou de tout composant WATE
48. ouvoir joindre les Maintenant pret tre utilis tuyaux la croix du r servoir Si n cessaire placez le r servoir sur des briques ou des blocs de b ton de machefer pour vous assurer qu il soit la bonne hauteur Branchez le r servoir la conduite d alimentation de la pompe en utilisant une tuyauterie ad quate Suivez tous les codes et ordonnances locales et provinciales Remarque ne placez pas le r servoir dans un endroit o il y a risque de gel du r servoir ou des commandes Cela peut endommager le syst me 2 Vissez en premier les raccords de tuyauterie manuellement puis serrez les avec la cl tuyau 5 R installez le c blage au manostat Fixez les conducteurs aux connexions en suivant vos indications Fig 16 4 Remettez le couvercle au manostat Assurez vous que le robinet de vidange standard de vidange de la chaudi re soit ferm Fig 17 5 Enlevez le capuchon de plastique du robinet d admission d air sur le dessus du r servoir Avec le manom tre pneus v rifiez la charge d air du r servoir Ajustez la pression de pr charge dans le r servoir de 1 2 psi en dessous du r glage de l amor age du manostat de la pompe Regardez tout d abord l int rieur du capuchon au manostat pour d terminer le r glage de l amor age du manostat de la pompe Il devrait indiquer 20 40 ou 30 50 o un r glage similaire La pression dans le r servoir devrait tre ajust e pour
49. po que el demandante de la garant a tuvo el producto antes de enviar la notificaci n del reclamo de la garant a WATI ER66 WORKER 1400 Division Road West Warwick RI 02893 Tel 401 884 6300 Fax 401 885 2567 www waterworkerdiy com 15 16
50. ro Si el medidor se mueve deje que la bomba siga funcionando Si el medidor no se mueve apague el suministro el ctrico Esto significa que el interruptor de presi n est mal instalado o es defectuoso Verifique las instrucciones del fabricante De ser necesario reempl celo y vuelva a probar el sistema para ver que se haya instalado correctamente Abra una canilla cercana para ver si el sistema funciona correctamente MUESTRA A TANQUES VERTICALES N DE PRESI N DE MODELO PRECARGA IMPORTANTE Instrucciones de seguridad Aseg rese de leerlas IMPORTANT Este tanque esta dise ado para ser usado con agua potable est limitado a una presi n m xima de 100 psi y a una temperatura m xima de trabajo de 54 C 130 P Tenga en cuenta que un calentador de agua o una caldera en un sistema hidr nico de calefacci n habitualmente calentar el agua a m s de 54 C 130 F Use un tanque de expansi n termal para el desbordamiento de agua caliente de un calentador de agua o use un tanque de expansi n para el desbordamiento de agua caliente de un sistema hidr nico de calefacci n Consulte el manual del usuario para obtener informaci n sobre el caudal de la bomba AWARNING PELIGRO DE EXPLOSI N O ROTURA Se debe instalar una v lvula de alivio para evitar que la presi n exceda los requisitos del c digo local o la presi n de trabajo m xima designada en el Manual del producto la que sea menor No exponga el prod
51. rolif rer et ce particulierement pendant les p riodes de non utilisation Consultez votre professionnel local en plomberie concernant la d marche suivre pour d sinfecter s curitairement votre plomberie r sidentielle WARNING DANGER RISQUE D EXPLOSION LORSQUE LE RESERVOIR POUR PUITS A ETE EN SERVICE ET QU UN CHANGEMENT UNE PRESSION DE PR CHARGE SUP RIEURE A WARNING EST N CESSAIRE EN RAISON D UNE MODIFICATION REQUISE AU R GLAGE DU MANOSTAT OMETTRE DE SUIVRE LES INSTRUCTIONS DU MANUEL POURRAIT CAUSER UNE RUPTURE OU UNE EXPLOSION POSSIBLEMENT CAUSER DES BLESSURES GRAVES OU LA MORT ET OU DES DOMMAGES MATERIELS N AJUSTEZ PAS LA PRESSION DE PRECHARGE S IL Y A EU UNE REDUCTION DU TEMPS DE LA FREQUENCE DE POMPAGE OU LA PRESSION DE PRECHARGE COMPAREE A SON REGLAGE INITIAL LA RAISON EST QUE LA REDUCTION EN TEMPS DE LA FREQUENCE DE POMPAGE PEUT SURVENIR D UNE PERTE DE PRESSION D AIR DANS LE RESERVOIR QUI A SON TOUR PEUT INDIQUER QU IL Y A PEUT TRE DE LA CORROSION INTERNE ET TOUTE REPRESSURISATION OU PRESSION ADDITIONNELLE POURRAIT PROVOQUER UNE RUPTURE OU UNE EXPLOSION ET OU DES DOMMAGES MATERIELS PRESSION DE SERVICE MAXIMALE Chaque r servoir WARNING pour puits est test pour sont tanch it l air 125 psi manom triques la pression de service maximale pour la conduite du r servoir pour puits S il s av rait que la pression surpasse 125 psi manom triques une bonne s lection et un bon format de r
52. s de jard n o bloques de hormig n para asegurarse de que est a la altura adecuada Conecte el tanque a las l neas de suministro de la bomba usando tuber as para que encajen Siga todos los c digos y las regulaciones estatales y locales vigentes Nota No coloque el tanque donde este o los controles se puedan congelar Esto puede da ar el sistema Abra la v lvula de esclusa para dejar correr el agua de nuevo hacia el tanque Esta es la v lvula que cerr en el paso 1 3 consulte el paso 1 3 para ver la foto de la v lvula de esclusa Fig 18 Abra la canilla de la casa que est m s alta y m s lejos del tanque Esto permitir que el aire salga del sistema 2 Primero enrosque las uniones de las a medida que entra el agua tuber as a mano luego ajuste con la llave inglesa Vuelva a encender el suministro 3 Vuelva a instalar los cables en el el ctrico La bomba arrancar interruptor de presi n Coloque los y llenar el tanque Controle que no cables en las conexiones seg n lo que haya filtraciones en el sistema Si ve haya marcado Fig 16 una filtraci n apague el suministro el ctrico de inmediato y repare la 4 Vuelva a colocar la tapa del interruptor filtraci n en la junta Le tomar de To e de presi n Aseg rese de que la v lvula 30 segundos a 1 minuto a la bomba de drenaje de la caldera del drenaje cebar si es una bomba a chorro Si la est ndar est cerrada Fig 17 bomba no llena el tanque y se apag
53. s produits de remplacement neufs ou usag s WATER WORKER n acceptera pas toutes r clamations pour des co ts de main d oeuvre ou pour tout autre co t Ce que cette garantie ne couvre pas Exclusions et restrictions Cette garantie ne couvre pas toute d faillance ou tout probl me moins qu il n ait t caus par une d fectuosit mat rielle ou de main d oeuvre De plus cette garantie ne s appliquera pas e Si le produit n est pas correctement install utilis r par ou entretenu tel qu indiqu dans le manuel fourni avec le produit e Pour toute d faillance ou d fectuosit encourue lors d abus y compris le gel n gligent et inad quat manutention exp dition par quiconque autre que WATER WORKER entreposage utilisation fonctionnement accident ou modification foudre inondation ou toute autre condition environnementale e Pour toute d faillance ou tout probl me r sultant de l utilisation du produit a des fins autres que celles sp cifi es dans le manuel du produit ou la modification de toute pi ce du produit e La pr sente garantie ne couvre pas les co ts de main d oeuvre les frais d exp dition les frais de services les d penses aff rentes la livraison les frais administratifs ou tout co t engendr lors de la d sinstallation ou de l installation du produit e La pr sente garantie ne couvre pas les r clamations soumises WATER WORKER un distributeur ou a un d taillant autoris WATER WORKE
54. surlebrasdu croisillon de la croix du r servoir Serrez en utilisant la cl tuyau Fig 13 Un bac r cepteur WARNING connect un drain ad quat doit tre install s il y a un risque qu une fuite et qu une inondation cause des dommages mat riels la zone adjacente l appareil ou aux tages inf rieurs de l immeuble 6 Installez la soupape de surpression dans l ouverture du filetage femelle sur l avant de la croix du r servoir Fig 14 Assurez vous de IMPORTANT toujours quiper ad quatement votre syst me pour puits avec une bonne soupape de surpression tape Ill installez le bloc croisillon sur le nouveau r servoir 1 Enlevez le bouchon en plastique du coude au bas du r servoir Jetez le bouchon 2 Installez le bloc croisillon au r servoir Utilisez soit le nouveau bloc croisillon du r servoir assembl selon l tape ll ci dessus ou r utilisez le bloc de l ancien r servoir 3 Appliquez du ruban Teflon au filetage au bas de la tige de la croix du r servoir Ins rez la tige dans le raccord du filetage femelle au bas du r servoir Serrez manuellement puis avec la cl Fig 14 15 Etape IV installez le nouveau r servoir tape V r tablissez l alimentation lectrique 1 Installez le nouveau r servoir Placez le l endroit o se trouvait l ancien La pompe remplira le reservoir Le syst me est r servoir ou positionnez le verticalement afin de p
55. to cuenta con una garant a de 5 a os Consultar la Garant a Limitada de WATER WORKER para mas detalles AWARNING LEA DETENIDAMENTE EL MANUAL DE INSTALACI N FUNCIONAMIENTO Y MANTENIMIENTO DEL PRODUCTO SI NO SIGUE LAS INSTRUCCIONES Y LAS ADVERTENCIAS EN EL MANUAL PODR AN PRODUCIRSE LESIONES GRAVES O MORTALES O DA OS MATERIALES E INVALIDAR LA GARANT A DEL PRODUCTO ESTE PRODUCTO DEBE SER INSTALADO POR UN PROFESIONAL CALIFICADO SIGA TODAS LAS NORMATIVAS Y LOS C DIGOS ESTATALES Y LOCALES VIGENTES EN CASO DE NO TENER DICHOS C DIGOS SIGA LAS EDICIONES ACTUALES DEL C DIGO DE PLOMER A NACIONAL Y DEL C DIGO DE ELECTRICIDAD NACIONAL SEG N CORRESPONDA PARA ALERTAR SOBRE POSIBLES LESIONES PERSONALES Y OTROS PELIGROS OBEDEZCA TODOS LOS MENSAJES DE SEGURIDAD QUE SIGAN ESTE S MBOLO PARA DISMINUIR EL RIESGO DE LESIONES PERSONALES Y DA OS MATERIALES A ESTE ES EL S MBOLO DE LAS ALERTAS DE SEGURIDAD SE USA INFORMACI N DE SEGURIDAD GENERAL IMPORTANTE EN LAS SIGUIENTES INSTRUCCIONES APARECEN ALERTAS DE SEGURIDAD ESPECIFICAS ADICIONALES AWARNING Si no se usa uN tama o de tanque de pozo adecuado esto implicara una tension excesiva y podria producir fallas en el producto filtraciones desbordamientos o da os materiales AWARNING Para su seguridad debe seguir la informacion en este manual para minimizar el riesgo de descargas el ctricas lesiones personales o da os materiales Realice la conexi n a tierra adecuada para cu
56. ucto a temperaturas de congelaci n o que excedan los 93 C 200 F No ajuste la precarga ni vuelva a aplicar presi n a este producto excepto en los ajustes requeridos al momento de la instalaci n inicial en especial si el producto se corroe se da a o disminuye su integridad Los ajustes de precarga se deben realizar solo a temperatura ambiente Si no se calibra el producto de manera adecuada o no sigue estas instrucciones causar una tensi n excesiva en el sistema que llevar a la falla del producto a lesiones personales graves o mortales a filtraciones o a da os materiales AWARNING Este producto como la mayor a de los productos a presi n se puede corroer con el paso del tiempo Se puede debilitar y estallar o explotar causando lesiones graves o mortales filtraci n o desbordamiento o da os materiales Para minimizar el riesgo un profesional autorizado debe instalar el producto e inspeccionarlo y realizar el servicio t cnico peri dicamente Se debe instalar una bandeja colectora a un drenaje adecuado en caso de que la filtraci n o el desbordamiento puedan causar da os materiales No lo coloque en un rea donde la filtraci n del tanque o las conexiones puedan causar da os materiales al rea adyacente al artefacto o a pisos inferiores de la estructura A Cloro y agua agresiva la calidad del agua puede WARNING influenciar de forma significativa la vida til de este producto Debe hacer una prueba para elementos corrosiv
57. using a tank cross assembly or assembling a new one check to make sure that the assembly includes a pressure relief valve that is capable of discharging the full output of the pump at or below the maximum working pressure of the lowest rated component in the system See the owner s manual for your pump for output information This is vital for safe operation of the system Step Il Assemble the new tank cross unit NOTE If you are re using the tank cross assembly from the old tank skip to Step Ill How to Install the Tank Step I Disconnect and remove the exist ing tank after turning the power off and 1 If you are using new parts for draining the system 1 2 Insert the pipe nipple into one 2 Open a faucet inside the house ee O oe cee ts tae oa caer oe dk doesn t matter which one Tah ane GUE ae using the pipe wrench 3 Close the ball or gate valve this 3 Insert the pressure gauge in the fl the valve that controls the other hole on top of the crossbar ow of water from une tank into Tighten using the adjustable the plumbing system inside the wrench on the square brass nut house Fig 1 Tighten hand tight then wrench 4 Drain the remaining water from coe oe alk Ra the tank ue garden hose ahs sufficient seal Once tightened i Le R RE do not loosen If you do the joint the front of the tank cross Place ESMAS 12 the other end of the hose in a bucket so that it is at a level lower 4 ee re ae ae than the faucet Ope
58. vous r utilisiez le bloc croisillon du r servoir ou que vous en assembliez Un nouveau assurez vous que le bloc comprenne une soupape de surpression en mesure d vacuer le d bit complet de la pompe ou en dessous de la pression maximale de fonctionnement du composant pr sentant la plus faible pression dans le syst me Consultez le manuel du propri taire de votre pompe pour l information de sortie Cela est primordial pour le fonctionnement s curitaire du syst me pour puits Comment installer le reservoir tape lorsque vous aurez ferm l alimen tation lectrique et vid le syst me d bran chez et enlevez le r ser voir existant 1 Trouvez la bo te fusibles ou le panneau des disjoncteurs de votre maison Coupez le courant la pompe pour puits AW ARNIN G Pour votre s curit les informations qui se trouvent dans ce manuel doivent tre suivies pour r duire le risque de chocs lectriques de dommages mat riels ou de blessures Assurez vous d avoir une mise la terre ad quate et conforme aux codes et aux ordonnances Ouvrez un robinet l int rieur de la maison Videz l eau du syst me jusqu ce qu elle cesse de couler Fermez le robinet tournant sph rique ou le robinet vanne il s agit du robinet qui contr le le d bit d eau entre le r servoir et la plomberie qui se trouve l int rieur de la maison Fig 1 Videz ce qui reste d eau dans le r servoir avec un tuyau d arrosage
59. well tank and other system components should the pressure switch malfunction and fail to shut the pump off The relief valve should be installed at the connection of the well tank to the system piping and have a discharge equal to the pump s capacity at 75 psig At least once every 3 years or if discharge is present a licensed contractor should inspect the temperature and pressure relief valve and replace if corrosion is evident or the valve does not function FAILURE TO INSPECT THIS VALVE AS DIRECTED COULD RESULT IN UNSAFE TEMPERATURE OR PRESSURE BUILD UP WHICH CAN RESULT IN PRODUCT FAILURE SERIOUS INJURY OR DEATH AND OR SEVERE PROPERTY DAMAGE AND VOID THE PRODUCT WARRANTY For your safety the information in this manual WARNING must be followed to minimize the rise of electric shock property damage or personal injury Properly ground to conform with all governing codes and ordinances Do not use this tank for chemicals solvents petroleum products acids or any fluids other than potable water This can cause oremature failure due to corrosion Make sure that the pressure switch in your well system is set low enough to shut off the pump If all of the faucets and valves are closed in your plumbing system and the pressure switch setting is too high the pump can run continuously without moving water through the system This could damage or burn out the pump CALIFORNIA PROPOSITION 65 WARNING WARNING This product contains a chemica

Download Pdf Manuals

image

Related Search

Related Contents

Hypertec N11018AHY User's Manual    エーエムディ トライアクトロック 取扱説明書(PDF)      Philips AQ6345/14 User's Manual  Quantum FastStor 22 Quick Start Guide  PowerPak for PowerPoint  Mode d`emploi e  superintendência de água e esgoto  

Copyright © All rights reserved.
Failed to retrieve file