GE PVW7301EJES Instructions / Assembly

image

Contents

1. Screw 31 11007 Fit the recirculation duct with extensions over the vent exhaust outlet and push down to seat on outlet Attach the vertical duct work to the top of the hood Check that the recirculation duct is in the proper orientation hole facing towards the back of the hood NOTE Hole must be facing toward back r i of hood Recirculation Duct with Vent Exhaust Extensions Outlet 4 Go to Mount the Glass Range Hood section MOUNT THE GLASS RANGE HOOD NOTE If ductless recirculation installation follow steps 1 6 If ducted installation follow steps 1 3 Using 2 or more people lift the range hood and place on the hood mounting bracket Make sure the bracket fully engages the holes on the hood body Duct Cover Screw Hood Mounting Bracket Place a mounting screw into the duct cover anchor at the center slot provided on the bottom of the back side of the hood Securely tighten f 2 I 5 Y Y Fy Ny i V fof Mounting Screw Secure the hood to the mounting bracket by fastening a duct cover screw in hole B on both sides of bracket shown previously SNOILINYLSNI NOILVTIVLSNI Installation Instructions MOUNT THE GLASS RANGE HOOD Continued 4 Remove the top duct cover bracket from the wall 5 Align the top edge of the duct cover bracket with FINISH THE INSTALLATION 1 Ducted installation only Connect the house ducting to the
2. detenimiento IMPORTANTE Guarde estas instrucciones para el uso de inspectores locales IMPORTANTE Cumpla con todos los c digos y ordenanzas vigentes Nota al instalador Aseg rese de dejar estas instrucciones con el Consumidor Nota al consumidor Conserve estas instrucciones para referencia futura Nivel de capacidad La instalaci n de esta campana de ventilaci n requiere capacidades mec nicas y el ctricas b sicas Tiempo de finalizaci n Aproximadamente de 1a 3 horas El instalador tiene la responsabilidad de efectuar una instalaci n adecuada La Garant a no cubre las fallas del producto debido a una instalaci n incorrecta A PRECAUCION Debido al peso y tama o de estas campanas de ventilaci n y para reducir el riesgo de lesiones personales o da os al producto SE NECESITAN DOS PERSONAS PARA REALIZAR UNA INSTALACION CORRECTA PARA SU SEGURIDAD AADVE RTENCIA antes de comenzar la instalaci n desconecte la energ a del panel de servicio y bloquee los medios de desconexi n para evitar el accionamiento de la energ a de manera accidental Cuando los medios de desconexi n de servicio no pueden bloquearse coloque sobre el panel de servicio un dispositivo de advertencia bien visible como una etiqueta A ADVERTENCIA para REDUCIR EL RIESGO DE INCENDIO DESCARGA EL CTRICA O LESIONES A PERSONAS CUMPLA CON LOS SIGUIENTES PUNTOS A El trabajo de instalaci n y el cabl
3. 2 Max ESPACIO DE INSTALACI N Estas campanas de ventilaci n est n dise adas para ser instaladas en una pared sin gabinetes superiores e Instale estas campanas entre el m nimo requerido de 24 y el m ximo recomendado de 36 sobre la superficie de cocci n 24 Required Min 36 Recommended Max La campana de ventilaci n debe ser instalada entre el m nimo requerido de 24 y el m ximo recomendado de 36 sobre la superficie de cocci n La altura de instalaci n de la campana sobre la superficie de cocci n depende de la altura del cielorraso y las limitaciones de la cubierta del conducto La cubierta plegable oculta los conductos que van desde la parte superior de la campana hasta el cielorraso Para las alturas de cielorraso de las cubiertas de conductos consulte la tabla de la p gina 5 NOTA La altura de instalaci n debe medirse desde la superficie de cocci n hasta la parte m s baja de la campana Puede contar con ventilaci n hacia el exterior o puede ser instalada para un funcionamiento con recirculaci n Para un funcionamiento con recirculaci n consulte la Planificaci n para la Instalaci n con Recirculaci n 31 11007 Preparaci n para la instalaci n PLANIFICACI N PREVIA Planificaci n para la Instalaci n con Conducto e Esta campana est dise ada para ventilarse en forma vertical a trav s del cielorr
4. Montaje de la Base de la Campana Soportes de la Cubierta del Conducto Tornillos Autorroscantes para Pared Seca Para la Caja de Empalmes Soporte de Recirculaci n Extensiones del Conducto de Recirculaci n 31 11007 Preparaci n para la instalaci n DIMENSIONES DE INSTALACI N Las Campanas con Chimenea de Vidrio son ajustables y est n dise adas para adaptarse a diferentes alturas de cielorraso Las cubiertas de los conductos pueden ser ajustadas para cielorrasos de entre 7 4 1 4 y 9 3 1 4 dependiendo de la distancia entre la parte inferior de la campana y la superficie de cocci n distancia X Cubierta del Conducto Superior Ejemplos de Altura M nima Requerida y Altura M xima Recomendada de Cielorraso M n de 5 1 8 Max de 16 1 8 Cubierta del Conducto Inferior Para realizar instalaciones en cielorrasos m s altos el Kit de Cubiertas 18 1 2 X Distancia Desde la Campana Hasta la Superficie de Cocci n Varia dependiendo de la instalaci n M nimo Requerido 24 M ximo Requerido 36 tambi n consulte la recomendaci n del fabricante de cocinas Base del Gabinete de Conductos para Cielorrasos Altos UXDC71 incluye una nueva cubierta de conductos para reas inferiores de 29 1 8 que reemplaza la cubierta de conductos para reas inferiores de 21 3 8 incluida con la campana COMPONENTES DE LAS HERRAMIENTAS NOIDVIVLSNI V1 VA VA
5. agujero puede ser ubicado a 4 hacia la izquierda o derecha de la l nea central C mientras permanece a entre 4 y 13 del cielorraso Una vez marcado el centro del agujero haga un agujero de 1 Y4 de di metro Cielorraso 4 a 13 del Cielorraso 31 11007 Instrucciones de instalaci n PREPARE LA CAMPANA PARA SU INSTALACION Retire el filtro de grasa de la unidad y deje el mismo a un lado El filtro de grasa es retirado presionando la manija que se encuentra frente al filtro Al realizar el reemplazo aseg rese de que el filtro est correctamente posicionado con las manijas en el frente y visibles Instalaciones Ventiladas 1 De forma segura presione el regulador que se encuentra sobre la abertura del escape Controle que el regulador se pueda abrir libremente Retire y descarte de forma adecuada el envoltorio protector de pl stico de la campana y de los filtros de grasa Consulte la secci n de Montaje de la Campana Extractora de Vidrio Instalaciones sin ventilaci n sin conducto NOTA Incluidos con la campana se encuentran un conducto de recirculaci n extensiones y un soporte y todos son necesarios para la instalaci n con recirculaci n Un filtro de carb n no incluido tambi n es necesario para la instalaci n con recirculaci n El regulador no est instalado en la unidad con instalaci n con recirculaci n 1 Instale las extensiones del conducto con recirculaci n al
6. on the hood AWARN l N G The improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded NOI1Va4V4318Y4d NOILVTIVLSNI INSTALLATION PREPARATION Installation Preparation TOOLS AND MATERIALS REQUIRED NOT SUPPLIED On __ Pencil and tape measure Safety glasses EG Phillips screwdriver gt Wire cutter stripper Electric drill with 2 Phillips flat head and 9 32 drill bit Aluminized Duct tape O lt lt UL listed wire nuts Strain relief for junction box REMOVE THE PACKAGING ACAUTI ON wear gloves to protect against sharp edges e Remove the duct covers e Remove the hardware bag literature package and other boxed parts e Remove and properly discard the protective plastic wrapping and other packaging materials PLAN THE INSTALLATION ACAUTION To reduce risk of fire and to properly exhaust air be sure to duct the air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages PARTS SUPPLIED FOR INSTALLATION e 1 Hardware Package e 1 Literature Package PARTS NEEDED FOR INSTALLATION e 1 Strain Relief e Power Supply Cable e 1 Wall or Roof Cap for ducted venting only e All Metal Ductwork for ducted venting only e Recirculat
7. 8 min Required Min amp Recommended 16 1 8 max qe Max Ceiling Height Examples Lower Duct Cover Canopy 18 1 2 For higher ceiling installations the High Ceiling Duct Cover Kit JXDC71 includes a new 29 1 8 lower duct cover which would replace the 21 3 8 lower duct cover that came with the hood X Distance From Hood To Cooktop Varies depending on installation Required Min 24 Recommended Max 36 also consult cooktop manufacturer s recommendation v A Cabinet Base 36 HARDWARE COMPONENTS NOILWVadVdsdd NOILVTIVLSNI Installation Preparation PREPARE THE WALL Hood Body 1 Puta protective covering over the surface below Duct Covers and Power Supply 1 Place one of the duct cover brackets against the wall so that its top edge is 1 16 from the ceiling and level Align the center notches of INSTALLATION PREPARATION the location of the hood to protect from dirt and or damage Determine and mark the centerline on the wall draw line up to the ceiling where the range hood will be installed Based on the ceiling height determine the distance 24 required min 36 recommended max X needed between the cooking surface B and the bottom of the hood To this distance add 12 5 8 and draw a horizontal line A about 24 long centered on the vertical centerline C 24 to 36 Align the top edge of the mounting bracket with the horizontal li
8. Installation Instructions Glass Wall Chimney Vent Hoods PVW7301 PVW7361 If you have questions call 800 GE CARES 800 432 2737 or visit our website at GEAppliances com BEFORE YOU BEGIN Read these instructions completely and carefully s IM PO RTANT Save these instructions for local inspector s use e IMPORTANT observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the Consumer e Note to Consumer Keep these instructions for future reference Skill level Installation of this vent hood requires basic mechanical and electrical skills Completion time Approximately 1 to 3 hours Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty ACAUTION Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION FOR YOUR SAFETY AWARN ING Before beginning the installation switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel A WARNING To REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work a
9. N IDV JVYd3 d PREPARACION PARA LA INSTALACION Preparaci n para la instalaci n PREPARE LA PARED Cuerpo de la Campana 1 Coloque una cubierta protectora sobre la superficie debajo de la ubicaci n de la campana a fin de proteger de la suciedad y o da os Determine y marque la l nea central sobre la pared dibuje la l nea hacia arriba hasta el cielorraso donde la campana extractora ser instalada En base a la altura del cielorraso determine la distancia m nima requerida de 24 y la distancia m xima recomendada de 36 X necesarias entre la superficie de cocci n B y la parte inferior de la campana A esta distancia agregue 12 5 8 y dibuje una l nea horizontal A de aproximadamente 24 de longitud centrada sobre la l nea central vertical C 24 to 36 A E VE 3 Alinee el extremo superior del soporte de montaje con la l nea horizontal A Alinee las ranuras centrales del soporte con la l nea central C y marque el centro de los agujeros del soporte Retire el soporte para perforar los 2 sostenes de montaje de la base en la pared donde se encuentran las marcas Vuelva a colocar el soporte de montaje en la pared e instale los 2 tornillos de montaje con 2 arandelas en los sostenes Ajuste los tornillos Perfore Aqu A Soporte de Montaje de la Campana Tornillos y Arandelas de Montaje Dibuje una segunda linea horizontal D con 1 agregada desde la dist
10. STALACION e 1 Amortiguador de Refuerzo e Cable de Suministro de Corriente e Una Tapa de Pared o Techo para ventilaci n con conducto nicamente e Toda la Tuber a Met lica para ventilaci n con conducto nicamente e Conducto de Recirculaci n para instalaci n con recirculaci n nicamente A ADVERTENCIA RIESGO DE LESIONES PERSONALES Debido al peso y tama o de la base de la campana extractora Es recomendable que la campana extractora sea instalada por 2 personas Si la campana no es elevada de forma correcta se podr n producir da os sobre el producto o lesiones personales NOTA Esta campana puede ser instalada con conducto o con recirculaci n En una aplicaci n con conducto esta campana puede ser ventilada a trav s de la pared o del cielorraso Al ser instalada por recirculaci n la campana ventila hacia afuera los costados de la cubierta del conducto NOTA Antes de realizar cualquier corte o agujero para la instalaci n determine qu m todo de ventilaci n ser usado y con cuidado calcule todas las medidas 31 11007 COMPONENTES DE LA CAMPANA EXTRACTORA Secci n de la Base Cubierta del Conducto Superior Cubierta del Conducto Inferior Tornillos de Montaje Soportes de Montaje de la Cubierta del Conducto Regulador Tornillos de la Cubierta Conducto de Recirculaci n del Conducto Soporte de Montaje Arandelas Soportes de
11. TANTE Tenga a bien leer cuidadosamente AADVERTENCIA PARA SEGURIDAD PERSONAL ESTE APARATO DEBE CONECTARSE A TIERRA DE MANERA ADECUADA Quite el fusible o abra el interruptor de circuitos antes de comenzar la instalaci n No utilice un cable de extensi n o un enchufe adaptador con este artefacto Siga los C digos El ctricos Nacionales o c digos y ordenanzas locales vigentes Suministro el ctrico Estas campanas de ventilaci n deben contar con un suministro de 120V 60Hz deben estar conectadas a un circuito derivado individual con una adecuada conexi n a tierra y deben contar con la protecci n de un interruptor de circuitos o un fusible con retraso de 15 o 20 amperios e El cableado debe ser de 2 hilos con conexi n a tierra e Si el suministro el ctrico no cumple con los requisitos anteriores llame a un electricista con licencia antes de continuar e Dirija el cableado dom stico lo m s cerca posible a la ubicaci n de la instalaci n en el cielorraso o pared trasera Ver p gina 14 para m s detalles e Conecte el cableado al cableado dom stico en cumplimiento con los c digos locales Instrucciones de conexi n a tierra El conductor a tierra debe conectarse a un metal con conexi n a tierra un sistema de cableado permanente o una terminal o conductor de conexi n a tierra del equipamiento en la campana A ADVERTENCIA una conexi n inadecuada del conductor de conexi n a tierra del equipamie
12. ancia X Dibuje un agujero en la pared con una broca de 9 32 en la intersecci n de la l nea horizontal D y la linea central vertical C Inserte un sost n en la cubierta del conducto Cubiertas de Conductos y Suministro de Corriente 1 Coloque uno de los soportes de la cubierta del conducto contra la pared de modo que su extremo superior est a 1 16 del cielorraso y que quede nivelado Alinee las ranuras centrales del soporte con la linea central C y marque los centros de los agujeros del soporte Retire el soporte para perforar 2 agujeros para la instalaci n con una broca de 9 32 e inserte los sostenes de la cubierta del conducto Vuelva a colocar el soporte en la pared e instale los 2 tornillos de montaje en los sostenes Ajuste los tornillos Coloque el otro soporte de la cubierta del conducto contra la pared de modo que su extremo superior est a 15 1 2 del cielorraso y que quede nivelado Alinee las ranuras centrales del soporte con la l nea central C y marque los centros de los agujeros del soporte Retire el soporte para perforar 2 agujeros para la instalaci n con una broca de 9 32 e inserte los sostenes de la cubierta del conducto Vuelva a colocar el soporte en la pared e instale los 2 tornillos de montaje en los sostenes Ajuste los tornillos Determine y marque el lugar donde el agujero ser perforado para que el cable de suministro de corriente pueda pasar a trav s de la pared El centro del
13. aso Use un conducto circular de 6 Utilice codos suministrados en forma local para ventilaci n horizontal a trav s de la pared trasera Determine la ubicaci n exacta de la campana de ventilaci n Planifique el recorrido de la salida de ventilaci n hacia el exterior A fin de maximizar el rendimiento de la ventilaci n del sistema de ventilaci n 1 Minimice la longitud del conducto y el n mero de transiciones y codos 2 Mantenga un tama o de conducto constante 3 Selle todas las juntas con cinta para conductos a fin de evitar p rdidas 4 No utilice conductos flexibles de ning n tipo Instale una cubierta de pared o casquete de techo con un regulador de tiro en la abertura exterior Solicite por adelantado la cubierta de pared o el casquete de techo y cualquier transici n o longitud de conducto necesarios Cuando corresponda instale un sistema de reposici n reemplazo de aire de acuerdo con los requisitos del c digo local de construcci n Para acceder a soluciones de aire disponibles visite GEAppliances com Planificaci n de Instalaci n con Recirculaci n Un conducto de recirculaci n incluido y un filtro de carb n no incluido son necesarios para la instalaci n con recirculaci n Planificaci n del Suministro de Corriente La ubicaci n de la conexi n del suministro de corriente es indicada en la secci n de Preparaci n de la Pared en la p gina 6 31 11007 SUMINISTRO DE ENERG A IMPOR
14. conducto con recirculaci n gt 2 Adhiera el soporte de montaje de conductos con recirculaci n al conducto mismo utilizando el tornillo para cubiertas de conductos suministrado con el paquete de herramientas Adhiera el mismo Usando el Tornillo de la Cubierta del Conducto 31 11007 3 Inserte el conducto de recirculaci n con extensiones sobre la salida del escape de ventilaci n y empuje hacia abajo para que coincida con la salida Adhiera el conducto vertical a la parte superior de la campana Controle que el conducto de recirculaci n se encuentre en la orientaci n correcta con el agujero hacia la parte trasera de la campana NOTA El agujero debe estar enfrentado hacia Pa Zo ee la parte trasera E ena mpana Conducto de Nu Salida del Escape de la Ventilaci n Recirculaci n con Extensiones 4 Consulte la secci n de Montaje de la Campana Extractora de Vidrio MONTE LA CAMPANA EXTRACTORA DE VIDRIO NOTA Si se trata de una instalaci n sin conducto recirculaci n siga los pasos 1 a 6 Si se trata de una instalaci n con conducto siga los pasos 1 a 3 Entre 2 o m s personas levanten la campana extractora y coloquen el soporte de montaje de la campana Aseg rese de que el soporte se adhiera completamente al cuerpo de la campana Tornillo de la Cubierta os del Conducto Soporte de Montaje de la Campana Campana Coloque un t
15. ct cover Slightly spread the sides of the cover apart and hook them behind the duct cover mounting brackets Attach the cover to the brackets with 4 duct cover screws NOTE Depending on the ceiling height and hood install height the upper duct cover can be installed with the exhaust vents on the top towards the ceiling or flip the duct cover and hide the exhaust vents under the lower duct cover Install the lower duct cover Slightly spread the sides of the cover apart and hook them behind the upper duct cover and the wall Slide the lower duct cover down to fit securely into the top of the range hood Finish attaching the lower duct cover to the chimney of the vent hood with 2 duct cover screws into holes on both sides of the cover Ascrew hole is located on each side of the duct cover Reinstall the metal grease filter to the vent hood Turn the power supply on Turn on blower and light If the rangehood does not operate check that the circuit breaker is not tripped or the house fuse blown If the unit still does not operate disconnect the power supply and check that the wiring connections have been made properly 31 11007 Instrucciones de instalaci n Pared de Vidrio Campanas de Ventilaci n de la Chimenea PVW7301 PVW7361 Preguntas Llame al 800 GE CARES 800 432 2737 o visite nuestro sitio Web en GEAppliances com ANTES DE COMENZAR Lea estas instrucciones por completo y con
16. damper on the hood body Seal all connections with duct tape INSTALLATION INSTRUCTIONS the top edge of the recirculation duct mounting bracket that is attached to the recirculation duct Align the center notches of each bracket Place both brackets back onto the wall in the previous position Install the 2 mounting screws into the anchors and securely tighten Ceiling M Recirculation Duct Bracket Top Duct Cover Bracket Attach the EN CHARCOAL FILTER 2 not included VEEL ELECTRICAL CONNECTION 1 Remove the cover from the field wiring compartment Feed the Power Supply Cable through the hole in the compartment 2 Connect the Power Supply Cable to the range hood junction box through the hole that was drilled in the Preparing the Wall section on page 6 Attach the White lead of the power supply A to the White lead of the range hood D with a wire nut Attach the Black lead of the power supply B to the Black lead of the range hood C with a wire nut Connect the Green E Green and Yellow ground wire under the Green grounding screw E ye Secure junction Secure the DY box to the junction Te wall using box to the y e A oles wall using 2 dry wall self tapping screws into the two diagonal holes in the junction box Reattach the field wiring compartment cover For ducted and recirculation installation Install the upper du
17. e superior hacia el cielorraso o dar la vuelta a la cubierta del conducto y esconder las ventilaciones de escape debajo de la cubierta del conducto inferior nstale la cubierta del conducto inferior Lentamente separe los costados de la cubierta y enganche ambos detr s de la cubierta del conducto superior y de la pared Deslice la cubierta del conducto superior hacia abajo para hacer que la misma coincida de forma segura con a parte superior de la campana extractora Finalice adhiriendo la cubierta del conducto inferior a a chimenea de la campana de ventilaci n colocando 2 tornillos en la cubierta del conducto sobre los agujeros que se encuentran a ambos lados de la tapa La cubierta del conducto cuenta con un agujero para tornillo a cada lado de la misma Vuelva a instalar el filtro de grasa met lico a la campana de ventilaci n Encienda el suministro de corriente Encienda el calefactor y la luz Si la campana extractora no funciona controle que el disyuntor no se haya activado o que el fusible hogare o no est quemado Si la unidad a n no funciona desconecte el suministro de corriente y controle que las conexiones del cableado hayan sido realizadas de forma correcta 31 11007
18. e power supply cable to be run through the wall The center of the hole can be located 4 to the left or right of the centerline C while remaining between 4 and 13 down from the ceiling Once the center of the hole is marked drill a 1 Y diameter hole Ceiling 4to 13 from Ceiling 31 11007 Installation Instructions PREPARE HOOD FOR INSTALLATION Remove the grease filter from the unit and set aside The grease filter is removed by pressing the handle in front of the filter When replacing make sure that the filter is properly positioned with the handles in front and visible Vented Installations 1 Securely press the damper on top of the exhaust opening Check that the damper opens freely Remove and properly discard the protective plastic wrapping from the hood and grease filter 3 Go to Mount the Glass Range Hood section Non vented ductless Installations NOTE A recirculation duct extensions and bracket are all included with the hood and are necessary for recirculation installation A charcoal filter not included is also needed for recirculation installation The damper is not installed on the unit with recirculation installation 1 Install the recirculation duct extensions to the recirculation duct 2 Attach the recirculation duct mounting bracket to the recirculation duct using the duct cover screw supplied with the hardware package Attach Using Duct Cover
19. eado el ctrico deben ser realizados por una persona s calificada de acuerdo con todos los c digos y est ndares aplicables incluyendo construcciones resistentes al fuego Es necesario contar con suficiente cantidad de aire para una combusti n y salida de gases adecuadas a trav s del conducto chimenea del equipo de consumo de combustible a fin de evitar r fagas de aire Siga las pautas del fabricante del equipo de calefacci n y los est ndares de seguridad tales como aquellos publicados por la Asociaci n Nacional de Protecci n contra Incendios National Fire Protection Association NFPA la Sociedad Estadounidense para la Calefacci n American Society for Heating los Ingenieros de Refrigeraci n y Acondicionadores de Aire Refrigeration and Air Conditioning Engineers ASHRAE y las autoridades de los c digos locales Al cortar o perforar una pared o un cielorraso no da e el cableado el ctrico y de otros servicios ocultos Los ventiladores con conducto siempre deben contar con ventilaci n hacia el exterior Desconecte el disyuntor de habitaciones adyacentes mientras est trabajando ADVERTENCIA a FIN DE REDUCIR EL RIESGO DE INCENDIOS USE SOLO CONDUCTOS DE METAL 991 0364 613 rev 1 31 11007 04 15 GE NOIDVIVLSNI 30 SINOIDINILSNI s Ld Ld PREPARACION PARA LA INSTALACION Preparaci n para la instalaci n DIMENSIONES DEL PRODUCTO 26 1 2 Min 37 1
20. ion Duct for recirculation install only AWARNING PERSONAL INJURY HAZARD Because of the weight and size of the rangehood canopy It is recommended that 2 people are used to install the range hood Failure to properly lift rangehood could result in damage to the product or personal injury NOTE This rangehood can be installed as either ducted or recirculation In a ducted application this rangehood can be vented through the wall or ceiling When installed for recirculation the rangehood vents out the sides of the duct cover NOTE Before making any cuts or holes for installation determine which venting method will be used and carefully calculate all measurements 31 11007 Installation Preparation RANGE HOOD COMPONENTS Canopy Section Upper Duct Cover Lower Duct Cover Mounting Screws Duct Cover Mounting Brackets Damper Duct Cover Screws me Recirculation Duct E Recirculation Duct Extensions 31 11007 H J K L Mounting Bracket Washers Canopy Mounting Anchors Duct Cover Anchors Dry Wall Self Tapping Screws for Junction Box Recirculation Bracket INSTALLATION DIMENSIONS The Glass Chimney Hoods are adjustable and designed to meet varying ceiling heights The duct covers can be adjusted for ceilings between 7 4 1 4 and 9 3 1 4 depending on the distance between the bottom of the hood and the cooktop distance X Upper Duct Cover 5 1
21. keup replacement air system in accordance with local building code requirements Visit GEAppliances com for available makeup air solutions Recirculation Install Planning A recirculation duct included and one charcoal filter not included are necessary for recirculation installation Power Supply Planning The location of the power supply connection is called out in the Prepare the Wall section on page 6 31 11007 POWER SUPPLY IMPORTANT Please read carefully AWARNING FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED Remove house fuse or open circuit breaker before beginning installation Do not use an extension cord or adapter plug with this appliance Follow National Electrical Codes or prevailing local codes and ordinances Electrical supply These vent hoods must be supplied with 120V 60Hz and connected to an individual properly grounded branch circuit and protected by a 15 or 20 amp circuit breaker or time delay fuse e Wiring must be 2 wire with ground e If the electrical supply does not meet the above requirements call a licensed electrician before proceeding e Route house wiring as close to the installation location as possible in the ceiling or wall e Connect the wiring to the house wiring in accordance with local codes Grounding instructions The grounding conductor must be connected to a ground metal permanent wiring system or an equipment grounding terminal or lead
22. nd 36 recommended maximum above the cooking surface The hood installation height above the cooking surface depends upon ceiling height and duct cover limitations The telescopic duct cover conceals the ductwork running from the top of the hood to the ceiling For supplied duct cover ceiling heights see table on page 5 NOTE Installation height should be measured from the cooking surface to the lowest part of the hood This hood must be installed onto a wall It can be vented to the outdoors or it can be installed for recirculating operation For recirculation operation see Recirculation Install Planning 31 11007 Installation Preparation ADVANCE PLANNING Duct Install Planning e This hood is designed to be vented vertically through the ceiling Use a 6 round duct Use locally supplied elbows to vent horizontally through the rear wall e Use metal ductwork only e Determine the exact location of the vent hood e Plan the route for venting exhaust to the outdoors To maximize the ventilation performance of the vent system 1 Minimize the duct run length and number of transitions and elbows 2 Maintain a constant duct size 3 Seal all joints with duct tape to prevent any leaks 4 Do not use any type of flexible ducting e Install a wall cap or roof cap with damper at the exterior opening Purchase the wall or roof cap and any transition and length of duct needed in advance e When applicable install any ma
23. nd electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors Turn off breaker to adjacent rooms while working AWARNING to REDUCE THE RISK OF FIRE USE ONLY METAL DUCT WORK SNOILINYLSNI NOILVTIVLSNI 991 0364 613 rev 1 31 11007 04 15 GE INSTALLATION PREPARATION PRODUCT DIMENSIONS Installation Preparation 26 1 2 Min 37 1 2 Max INSTALLATION CLEARANCES These vent hoods are designed to be installed onto a wall with no above cabinets e Install these hoods between the 24 required minimum and 36 recommended maximum above the cooking surface 24 Required Min 36 Recommended Max The vent hood must be installed between the 24 required minimum a
24. ne A Align the center notches of the bracket with the centerline C and mark the center of the bracket holes Remove the bracket to drill the 2 canopy mounting anchors into the wall at the markings Place the mounting bracket back on the wall and install the 2 mounting screws with 2 washers into the anchors Tighten screws Drill Here A Hood Mounting Bracket Mounting Screws amp Washers Draw a second horizontal line D that is 1 added from the X distance Drill a hole into the wall with a 9 32 drill bit at the intersection of the horizontal line D and vertical centerline C Insert a duct cover anchor the bracket and the centerline C and mark the centers of the bracket holes Remove the bracket to drill the 2 holes for installation with a 9 32 drill bit and insert the duct cover anchors Place the bracket back on the wall and install the 2 mounting screws into the anchors Tighten screws Place the other duct cover bracket on the wall so that its top edge is 15 1 2 from the ceiling and level Align the center notches of the bracket and the centerline C and mark the centers of the bracket holes Remove the bracket to drill the 2 holes for installation with a 9 32 drill bit and insert the duct cover anchors Place the bracket back on the wall and install the 2 mounting screws into the anchors Tighten screws Determine and mark where the hole will be drilled for th
25. nto puede provocar un riesgo de descarga el ctrica Consulte a un electricista calificado o representante de servicio t cnico si tiene dudas sobre la correcta conexi n a tierra del artefacto NOIOWIWLSNI V1 VA VA N IDV JVYd3 d oe ed Ed Ed PREPARACION PARA LA INSTALACION Preparaci n para la instalaci n HERRAMIENTAS Y MATERIALES REQUERIDOS no suMINISTRADOS Oj MZ Gafas de seguridad 5D L piz y cinta m trica EG Destornillador de estrella 205 Alicate pelacables Broca el ctrica con Phillips Cinta N 2 de cabeza plana y aislante de broca de 9 32 aluminio G Tapones de alambre ee de aprobados por UL Alivio de tensi n para la caja de conexiones QUITE EL ENVOLTORIO A PRECAUCION se guantes para protegerse de los bordes afilados e Quite las cubiertas de los conductos e Quite la bolsa de piezas el paquete de instrucciones y otras piezas en cajas e Quite y descarte adecuadamente el envoltorio pl stico de protecci n y otros materiales de empaque PLAN DE INSTALACI N APRECAUCION A fin de reducir riesgos de incendios y para que el aire salga de forma apropiada aseg rese de que el aire sea conducido hacia fuera No ventile el aire de la salida hacia espacios dentro de paredes o cielorrasos o ticos espacios muy bajos o garajes PIEZAS PROVISTAS PARA LA INSTALACION e 1 Paquete de Herramientas e 1 Paquete Escrito PIEZAS NECESARIAS PARA LA IN
26. ornillo de montaje en el sost n de la cubierta del conducto sobre la ranura central provista en la parte inferior del lado trasero de la campana Ajuste de forma segura Mounting Screw Asegure la campana al soporte de montaje ajustando el tornillo de la cubierta del conducto en el agujero B a ambos lados del soporte mostrado previamente NOIDVIVLSNI 30 SINOIDINILSNI INSTRUCCIONES DE INSTALACION 6 Soporte de la Cu bierta del Conducto Superior Instrucciones de instalaci n MONTE LA CAMPANA EXTRACTORA DE VIDRIO contin a 4 Retire de la pared el soporte superior de la cubierta del conducto Alinee el extremo superior del soporte de la cubierta del conducto con el extremo superior del soporte de montaje del conducto de recirculaci n el cual est adherido al conducto de recirculaci n Alinee las ranuras centrales de cada soporte Vuelva a colocar ambos soportes en la pared en la posici n previa Instale los 2 tornillos de montaje en los sostenes y ajuste de forma segura Cielorraso Soporte del Conducto de Recirculaci n Adhiera el FILTRO DE E CERA CARBON no incluido ES Z CONEXI N EL CTRICA 1 Retire la cubierta del compartimiento del cableado de campo Alimente el Cable de Suministro de Corriente a trav s del agujero del compartimiento Conecte el Cable de Suministro de Corriente a la caja de empalmes de la campana ext
27. ractora a trav s del agujero que fue realizado en la secci n de Preparaci n de la Pared en la p gina 6 Adhiera el cable blanco del suministro de corriente A al cable blanco de la campana extractora D con una tuerca para cable Adhiera el cable negro del suministro de corriente B al cable negro de la campana extractora C con una tuerca para cable Conecte el cable a tierra verde E verde y amarillo debajo del tornillo de conexi n a tierra verde Asegure la caja de empalmes a la pared usando E 2 tornillos autorroscantes para pared seca en los dos agujeros diagonales de la caja de empalmes Vuelva a adherir la cubierta del compartimiento de cableado de campo Asegure la caja de empalmes a la pared usando estos agu jeros FINALICE LA INSTALACI N dl Instalaci n con conducto nicamente Conecte el conducto hogare o al regulador del cuerpo de la campana Selle todas las conexiones con cinta para conducto Para instalaciones de recirculaci n y con conducto Instale la cubierta del conducto superior Lentamente separe los costados de la cubierta y enganche ambos detr s de los soportes de montaje de la cubierta del conducto Adhiera la tapa a los soportes con 4 tornillos de la cubierta del conducto NOTA Dependiendo de la altura del cielorraso y de la altura de instalaci n de la campana la cubierta del conducto superior puede ser instalada con las ventilaciones de escape en la part