RectorSeal LD92W Instructions / Assembly
Contents
1. 41 2 W x 31 4 D a LD 92 w Dual 3 4 Lineset BTU 36 000 Suction Lines 3 4 0D Insulation 3 8 Liquid Lines 3 8 0D Drain Line 3 4 PVC JE TN LD 92 w Single 3 4 Lineset BTU 42 000 Suction Line 3 4 OD Insulation 1 2 Liquid Line 3 8 0D Insulation 1 2 Drain Hose 7 8 OD LD 92 w Single 11 8 Lineset BTU 60 000 Suction Line 11 8 O0D Insulation 1 2 Liquid Line 1 2 OD Drain Line 3 4 PVC Lineset size may change on Seer Rating ECTO A SEAL www rectorseal com LD 122 w Dual 3 4 Lineset gt BTU 42 000 Suction Lines 3 4 OD Insulation 1 2 Liquid Lines 3 8 0D Insulation 1 2 Drain Hose 7 8 OD LD 122 w Single 11 8 Lineset BTU 60 000 Suction Line 11 8 OD Insulation 1 Liquid Line 1 2 0D Drain Line 3 4 PVC 4 LD 122 w Dual 3 4 Lineset BTU 36 000 Suction Lines 3 4 0D Insulation 1 2 Liquid Lines 3 8 0D Drain Line 3 4 PVC z ETN 2601 Spenwick Drive Houston TX 77055 713 263 8001 800 231 3345 713 263 7577 800 441 0051 741080 Specialty fitting installation instructions Flexible fitting INLINE COUPLING 1 Secure fitting and duct bases to wall 2 Cut LF duct to length and place in fitting 3 Secure LF duct with split Cap and two screws 4 Secure duct into coupler by fitting second part of cap F
2. ORTRESS Installation instructions 1 Determine the path which the line set will follow and strike a chalk line to mark the surface material Attach the base only of all fittings first ducting will be placed last along the marked path using fasteners of sufficient length not provided Predrill where necessary Duct must terminate with a fitting to prevent cover from sliding out of position 2 Once all fitting bases are se cured to the siding measure and cut LD Ducting to fit as needed Remember to account for some seasonal expansion and contrac tion Install and fasten LD Ducting bases Attach bases only to struc ture through provided punch outs using fasteners of sufficient length not provided Typical lineset capacity LD 92 31 2 W x 21 2 D 3 Position and twist in lineset duct clips Model LDC evenly spaced through out installation Nylon cable ties not included slip through lineset duct clips and fasten around lineset A 4 Run lineset drainhose wiring etc over the fitting and duct bases and secure to duct clips using tie wraps of sufficient size 5 Snap straight duct top over mating straight base pieces Seat fitting tops over mating fitting bases and secure with provided stainless screws Duct must terminate with a fitting to prevent cover from sliding out of position If duct is to be painted or duct is a dark color adhere cover to base with pvc cement LD 122
3. hat they are free from defects in material or workmanship If within one year of purchase this product shall prove to be defective it shall be repaired or replaced at RectorSeal s option subject to the terms and conditions set forth below Your original receipt of purchase is a requirement to determine warranty eligibility The limitations of lia ility set forth include body and all component parts as well as product itself as a whole Any purchaser or third party actions brought for any reason hereunder shall be brought in its entirety in Bristol County and no other jurisdiction and such actions shall be subject to the laws of the State of Massachusetts Any notice herein shall be sent to RectorS eal 2601 Spenwick Drive Houston TX 77055 General Terms and Conditions Purchaser must pay all labor and shipping charges necessary to ee product covered YY this warranty This warranty shall not apply to products which in the sole judgment of RectorS eal have been subject to negligence abuse accident tam er foreign materials in the system Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to RectorS eal as soon as possi but not limited to operational failures cause by corrosion rust or ot lea pening misapplication alteration nor due to improper installation operation or maintenance or storage nor to other than normal application use or service including er the discovery of an
4. itting List Ducting 8ft lengths P Coupler E gt Wall Inlet KS Soffit Inlet End Fitting Ki 90 Flat Ell qu 45 Flat Ell Limited Warranty and Limitation of Liability WALL CONNECTION 1 Seal and attach wall flange to wall 2 Place LF duct into fitting 3 Clamp LF duct with Cap and two screws LJ LW LP LEN LK a LKF D 90 Sweep Ell End fitting End fitting provides criti cal Support to the lineset duct cover Without this fitting the duct cover can Slide out of place To adjust the opening to Suit lineset size simply snip the end fitting along the desired groove and break off unwanted sections A coupling can also be utilized at the duct end for larger lineset fill GROOVES Available in WHITE IVORY BROWN and GRAY Sizes 3 1 2 92mm or 4 1 2 122mm lt 90 Inside Vertical Ell LCI 90 Outside Vertical Ell LCO 45 Inside Vertical Ell LCFI 45 Outside Vertical Ell LCFO Tee LT Reducer LDR LKS Wall Sleeve 1 Using a hole saw drill a hole at the desired point of penetration 2 Secure LW base over hole 3 Insert LWS sleeve into hole 4 Install lineset 5 Seal and attach LW cover SLEEVE 31 4 or 41 4 O D E Flexible Ell LF Flexible Adaptor LF N C Flexible Wall Flange LWF Wall Sleeve LWS lt gt Twistlock Linesetclips LDC RectorS eal aa warrants to the original consumer purchaser of its products t
5. or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state
6. y alleged defect RectorSeal will subsequently take corrective action as promptly as is reasonableThis warranty sets forthRectorS eal s sole obligation and the purchaser s exclusive remedy for defective products In all circumstances RectorSeal s maximum liability shall not exceed the actual purchase price paid for the product alone Warranty claims must be registered with Airtec within 30 days of damage or malfunction RectorSeal reserves the right to visit the site of the installation or to require documentation of the claim before assuming any responsibility under the provisions of this warranty Consumer agrees to inspect the product at the time of installation for any reasonable discernable defects and further agrees to inspect the product annually Any damages occurring which could have been avoided by proper inspection will not be the responsibility of Airtec RECTORSEAL SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER TO THE PURCHASER OR ANY THIRD PARTY THE FORRGOING WARRANTIES ARE EXLUSIVE AND IN LIEU OF ALL EXPRESS WARRANTIES IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN Some states do not allow the exclusion of limitation of incidental and consequential damages or limitations on how long and implied warranty lasts so the above limitations
Download Pdf Manuals
Related Search
Related Contents
Herpstat Intro + User`s Manual RT-PL 82 - Einhell 2 - Electrocomponents Emerson Y690VB Drawings & Schematics National Instruments CFP-RLY-421 User's Manual GLB 200 18 Li-Ion - Güde Slovakia sro Philips Electric shaver HQ914 dreamGEAR Silver Edition Rebel Manual 02-01 Windows & Mac Copyright © All rights reserved.