Home
Symmons 4305-STN Installation Guide
Contents
1. 10 Install mounting plate P2 Secure with two screws Q Replace cradle mount cover P1 13 Install showerhead D to shower arm E turning clockwise to tighten Note Mounting plate P2 center tabs must be horizontal for installation Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc www symmons com gethelp symmons com ZV 3055 REV 0 09 04 14 Operation Temperature Control Diverter Control 1 Turn shower handle counterclockwise approximately 1 Diverter handle facing straight down is for diverter 1 4 turn to put valve in cold position function 1 O eo O 2 4303 TRM amp 4305 TRM Turn diverter handle counterclockwise one full revolution for diverter 2 Turn shower handle counterclockwise approximately function 2 1 2 turn to put valve in warm position 4306 TRM Turn diverter handle counterclockwise 1 4 turn for diverter function 2 4305 TRM 4306 TRM DPV 3 Turn shower handle counterclockwise approximately 3 4 turn to put valve in hot position 3 4306 TRM Turn diverter handle counterclockwise 3 4 turn for diverter function 3 Ca
2. handle s with star washer G and screw J Attach plug button I to handles Notes Handles should be facing the 6 o clock position 6 Install tub spout W to pipe fitting Turn clockwise to secure Q 7 Install wall elbow B and flange C to recessed pipe fitting Turn elbow clockwise to tighten 8 Press tab to remove mounting plate P2 from cradle mount cover P1 Note Mounting plate P2 center tabs must be horizontal for removal Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc www symmons com gethelp symmons com ZV 3055 REV 0 09 04 14 Installation 9 Place mounting plate P2 in position mark and drill 1 8 pilot holes into stud 11 Attach cradle arm S and washer R to cradle mount P Secure with set screw 1 Option Place mounting plate P2 in position mark and drill 3 16 holes into wall Install anchors 12 Attach shower arm E and flange F to vertical shower pipe turning clockwise to tighten 14 Attach large end of hand shower hose X to hand shower V Attach small end of hand shower hose X and gasket to in line vacuum breaker A Connect in line vacuum breaker to wall elbow B Turn clockwise to tighten
3. 961 9621 2014 Symmons Industries Inc www symmons com gethelp symmons com ZV 3055 REV 0 09 04 14 Dimensions Measurements 2 1 4 57 mm 2 1 4 57 mm 0 O W gt m 6 152 mm 9 1 4 235 mm Female 1 2 IPS thread must be recessed 7 8 from finished wall xm om 6 152 mm right or left 7 178 mm 5 127 mm VELEN Floor Notes 1 All dimensions measured from nominal rough in see U as reference 77 1956 mm 4 3 4 121 mm 5 3 4 146 mm 9 1 4 235 mm Zi s rijxAsye O 10 254 mm 2 3 8 60 mm 32 813 mm 4306 TRM 42 1067 mm 4303 TRM 4305 TRM a i ALT EF l 2 Dimensions are subject to change without notice 12 305 mm 4 1 2 114 mm 3 1 4 83 mm 1 2 NPT 1 2 13 mm Rough in 2 3 8 1 2 60 mm 13 mm lt C ala DO V 8 1 2 216 mm Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc www symmons com gethelp symmons com ZV 3055 REV 0 09 04 14 Parts Breakdown Replacement Parts Item Description Part Number Vacuum Breaker 60 Hose Wall Elbow Flange EF 104 T 444 KIT Showerhead Shower
4. Arm Flange Star Washer Handle Plug Button Set Screw Lock Nut Dome Cover 300 T 19 20 PL Mounting Plate Mounting Screws Diverter Escutcheon Cradle Mount Cradle Mount Screws Washer Cradle Arm Set Screw Shower Escutcheon T249 Mounting Screws Hand Shower 432W Tub Spout 432TS Notes 1 Append STN to part number for satin nickel finish s lt xc anaon ovl OLZZ r xA o TLO amM ovliow x gt 2 Append 1 5 or 2 0 to showerhead or hand shower for low flow Required for Installation Adjustable wrench Phillips head screwdriver Plumber tape Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc www symmons com gethelp symmons com ZV 3055 REV 0 09 04 14 Installation Note Four valve body installation please see valve body installation guides 1 Install shower escutcheon U to shower valve Secure with two screws Y 4 Install shower and diverter dome covers L to valves Secure with lock nut K 2 Attach mounting plate O to diverter valve 4805 TRM and 4306 TRM only Secure with two screws M 3 Attach diverter escutcheon N to plastic mounting plate O Note Tabs should snap into place 5 Install diverter handle 4305 TRM and 4306 TRM only and shower handle H to valves Secure
5. EEA EEA 4303 TRM 4305 TRM 4306 TRM Sereno Trim Series Operation amp Maintenance Manual Model Numbers O 4303 TRM Hand Shower Trim O 4305 TRM Shower Trim with Hand Shower O 4306 TRM Tub Shower Trim with Hand Shower Specifications Tub shower trim with hand shower and lever handle includes wall connection cradle for hand shower mounting in line vacuum breaker flexible metal hose non diverter tub spout 1 mode hand shower and 1 mode showerhead with standard 2 5 gpm 9 5 L min flow restrictor Shower trim with hand shower and lever handle includes all of the above less non diverter tub spout Valve trim with hand shower and lever handle includes all of the above less non diverter tub spout and 3 mode showerhead Components made from metal and nonmetallic materials plated in standard polished chrome finish Modifications Warranty O 1 5 amp 1 5 gom 8 7 L min flow restrictor O 2 0 amp 2 0 gpm 7 6 L min flow restrictor O 432HSB 30 slide bar in place of wall cradle on hand shower units O SS Slip spout on any tub and shower unit O STN Satin nickel finish Note Append appropriate suffix to model number Limited Lifetime to the original end purchaser in consumer installations 5 Years for commercial installations Refer to www symmons com warranty for complete warranty information Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800
6. re and Cleaning 1 Clean finished trim area with a soft cloth using mild soap and water or a non abrasive cleaner and then quickly rinse with water Troubleshooting Chart Problem Solution Finish is spotting Elements in water supply may cause Clean finished trim area with a soft water staining on finish cloth using mild soap and water or a non abrasive cleaner and then quickly rinse with water Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 800 796 6667 Fax 800 961 9621 2014 Symmons Industries Inc www symmons com gethelp symmons com ZV 3055 REV 0 09 04 14