1. Note End of bay bow installation instructions Continuous air seal RELIABILITY for real life pa A JELD WEN WINDOWS amp DOORS INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin 11023 8 PREPARE SILL FOR GARDEN WINDOW Note The sill lip is the garden window s only source of support inside the rough opening It is very important that the sill be level and flat 1 Measure the length of the sill and cut a piece of flashing the exact length of the sill 2 Measure and draw a line 1 2 from the exterior edge of the sill this is where the flashing will sit 3 Remove foam backing and release tape under foam backing Ey INSTALL GARDEN WINDOW Warning To avoid injury use at least two people to install Temporarily support the window until fully installed 1 Place window sill onto the drain mat and tilt into the rough opening The window sill must rest on and be fully supported by the rough opening framing 2 Fasten window with a galvanized roofing nail through the nailing fin between 3 7 from one lower corner Width of rough opening 4 Press the adhesive section of the flashing onto outside section of sill 5 Pull release tape on remaining section of the flashing 6 Fold the flashing down onto the house wrap 7 Staple flashing to the wall and seal the corner edges 3 Inspect window for square level and p
2. 11023 11 COMPLETE GARDEN WINDOW IN Garden windows AFTER INSTALLATION are rated fora weight handling 1 Adjust window load of 8 Ibs for best per square foot operation Although it is 2 Install exterior not required wall surface the installer may within provide extra seven days support to the of window garden window installation with L brackets 3 Maintain Build seat board gap of 3 8 bracing under the between mull joints of the window frame unit To reduce and final heat loss the exterior wall bottom of the surface siding window may be stucco etc insulated Check local building code requirements 4 Ensure weep COMPLETE INSTALLATION holes channels are clear of debris for proper water drainage do not seal weep holes channels if present 5 Protect recently installed units from damage from plaster paint etc by covering the unit with plastic 1 Release the building wrap from above the header previously taped up and overlap the header flashing Seal the ends with self adhesive flashing or building wrap tape 2 Seal the top corners of the window with a 1 4 bead of sealant Tool into a fillet shape 3 Create a continuous air seal around the entire interior perimeter of the window with a bead of sealant where the window contacts the structure Please visit www jeld wen com for warranty and care and maintenance information
3. JELD WEN s recommended installation instructions for vinyl bay bow and garden windows which incorporate an integral nailing fin While the use of these installation instructions is recommended installation in strict compliance with AAMA specifications 2400 02 is an alternate method of window installation Use of the AAMA specifications 2400 02 will not affect application of the JELD WEN limited warranty Newer construction methods have led to an increase in air and water tightness in buildings This frequently leads to negative air pressure inside the home which can draw water through very small openings Our installation method integrates the window with the weather barrier typically building wrap GLOSSARY Mull Joint The joint where two or more window units are structurally joined together Mulled Unit Two or more window units structurally joined together Shiplap The layering method in which each layer overlaps the layer below it so that water runs down the outside Weep Hole weep channel The visible exit or entry part of a water drainage system used to drain water out of a window First Time 2 hrs Estimated Install Time for New Construction Experienced 1 5 hrs Professional 1 hr OPEN STUD CONSTRUCTION The wall framing needs to be covered by backing support before the window can be installed The window will be mounted with the nailing fin flush against
4. Protect from exposure to direct sunlight during storage e Install only when conditions and sheathing are dry IF INJURY OCCURS IMMEDIATELY SEEK MEDICAL ATTENTION MATERIALS e Backer rod 1 8 larger than the widest portion of the gap used in conjunction with sealant bead Note Follow all material manufacturers instructions for proper use and compatibility e Polyurethane low expansion Window and Door foam We recommend 1 e 1 3 4 galvanized roofing nails Nails must penetrate at least 1 into OSI QUAD Foam or equivalent framing or as required by local code e Non water degradable or compressible shims e 10 x 3 1 2 corrosion resistant pan head screws Screws must TOOLS penetrate at least 1 into framing or as required by local code e Tape measure e Caulking gun e Non water degradable or compressible shims to level the sill e Utility knife e Drill with 1 8 tapered bit and e 4 6 or 9 as required by local code and window configuration Level 4 minimum 3 8 countersink wide self adhesive flashing We recommend OSI QUAD Butyl recommended e Construction stapler with 3 8 Flashing Tape or equivalent e J roller staples e Spray adhesive primer for self adhesive flashing Such as Loctite 300 e Hammer or equivalent e Sealant We recommend OSI QUAD Max Sealant or equivalent This can be used in any application and can be painted or ordered in a color matched product if desired
5. Thank you for choosing JELD WEN WINDOWS amp DOORS 2014 JELD WEN inc This publication and its contents are owned by JELD WEN inc and are protected under the U S Copyright Act and other intellectual property laws All trademarks service marks logos and the like whether registered or unregistered are owned or controlled by JELD WEN inc or others Unauthorized use or duplication of JELD WEN intellectual property is prohibited JELD WEN reserves the right to change product specifications without notice Please check our website jeld wen com for current information 05 14 8 RELIABILITY for real life pa A
6. a REMOVE PACKAGING AND INSPECT WINDOW REMOVE PACKAGING e Splits cracks holes missing sections or other damage to the nailing fin longer than 6 and or within 1 2 of window frame Remove shipping materials such as corner covers shipping blocks or pads If there is a protective film on the glass do not remove it until e For units with integral head and seat boards ensure the top of the installation and construction are complete mull joints are covered and sealed with silicone INSPECT YOUR WINDOW If any of the above conditions represent a concern or if you expect environmental conditions to exceed the window s performance rating e Cosmetic damage do not install the window Contact your dealer or distributor for e Product squareness diagonal measurements not more than 1 8 recommendations different e Correct product size color grid pattern handing glazing energy efficiency requirements etc e Cracked frame welds 2 RELIABILITY for real life pa A JELD WEN WINDOWS amp DOORS a INSPECT ROUGH OPENING e Verify the width and height of the bay or bow window are each 1 2 smaller than the rough opening width and height The rough opening for the garden window should be the same size as the window frame E PREPARE ROUGH OPENING FOR RETROFIT INSTALLATIONS 1 Remove sufficient siding to expose enough intact building wrap to properly seal the window to the opening 2 Remove t
7. fillet shape 6 The head and seat boards should be protected and insulated with a structure designed and built as required by local code Bracing Under the Mull Joints Ww APPLY THE SELF ADHESIVE FLASHING Note Keep the edge of the self adhesive flashing as close to the window frame as possible 3 Fold the head board piece lengthwise into L shape Center and apply one leg to head board and the other to the wall above the rough opening header Cut the corners to allow the flashing to lay flat against the wall 4 Starting 2 above the header apply the side pieces 5 Center and apply the header piece above the header 6 Press the flashing down with a J roller 7 Inspect self adhesive flashing for gaps or bubbles remove and replace if necessary 7 Create a continuous air seal on the interior jambs and head between the rough opening and the window frame with low expansion polyurethane foam or backer rod and sealant On the sill run a continuous bead of sealant opening along the foam wedge where it meets the window frame or seat board AFTER INSTALLATION 1 Adjust window for best operation 2 Install exterior wall surface within 30 days of window installation 3 Maintain gap of 3 8 between window frame and final exterior wall surface siding stucco etc 4 Protect recently installed units from damage from plaster paint etc by covering the unit with plastic
8. JELD WEN WINDOWS amp DOORS INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin 11023 Ed IMPORTANT INFORMATION AND GLOSSARY Not all window types can be installed into every wall condition in all areas Consult your local building code official for applicable building codes and regulations Local building code requirements supersede recommended installation instructions Note Installations where the sill is higher than 35 feet above ground level or any product installation into a wall condition not specifically addressed in these instructions must be designed by an architect or structural engineer Failure to install windows into square level and plumb openings could result in denial of warranty claims for operational or performance problems Note to Installer Provide a copy of these instructions to the building owner By installing this product you acknowledge the terms and conditions of the limited warranty as part of the terms of sale E ROUGH OPENINGS This installation guide specifically addresses sheathed wall and open stud construction Windows without an integral head and seat board must be placed on a structure that provides continuous support to the sill FULLY SHEATHED WALL CONSTRUCTION The wall framing is covered by sheathing and the window will be mounted with the nailing fin flush against the sheathing Thank you for selecting JELD WEN products Attached are
9. he old window If building wrap is damaged apply new building wrap in shiplap manner Verify trimmer studs header are structurally sound Continue with the instructions 3 Trim the sides sufficiently to allow the nailing fin to be mounted against the sheathing INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin J11023 e Verify the rough opening is square The A and B measurements above should be the same Maximum allowable deviation from square is 1 8 for windows 20 sq ft and smaller and 1 4 for windows larger than 20 sq ft e Verify the rough opening is level and plumb C The maximum allowable deviation is 1 16 for every 2 of rough opening not to exceed 1 8 e The rough opening sill must not be crowned or sagged D A 5 degree sloped sill is recommended e Verify the exterior face of the rough opening is a single plane E with less than 1 8 twist from corner to corner e Verify the header is supported by trimmer studs PREPARE BUILDING WRAP i ssi iti izi s s CC zd BUILDING WRAP Note Check with the building wrap manufacturer to verify the following steps will not void their product warranty Follow manufacturers instructions 1 Trim building wrap flush with the rough opening 2 At the head cut building wrap at 45 and tape up as shown 3 Trim the sides sufficiently to allow the nailing fin to be mounted against the s
10. heathing Note If installing a bay or bow window proceed with section 4 PREPARE SILL FOR BAY BOW WINDOW If installing a garden window skip to section 8 PREPARE SILL FOR GARDEN WINDOW RELIABILITY for real life pa A JELD WEN WINDOWS amp DOORS PREPARE SHIM THE SILL 1 Use self adhesive flashing to waterproof the sill 2 Flashing must have at least 2 of visible material below nail fin Flashing width must be at least measurement 1424 13 4 3 Measure the width of the ot frame from the interior to the nail fin measurement 1 and subtract 1 4 Transfer this measurement from the outside Width of rough opening edge of the rough opening sill and draw a line all along the rough opening sill This is where the back of the flashing will sit 4 Cut a piece of flashing the length of the sill plus 12 5 Place flashing on rough opening sill wrapping the flashing up 6 on each jamb as shown 6 Pull release tape and set flashing into place 7 Fold the flashing down onto the sheathing Staple flashing to the wall and seal the corner edges as shown 5 INSTALL BAY BOW WINDOW Warning To avoid injury use at least two people to install Temporarily support the window until fully installed Note Window should be pre drilled and countersunk before placing inside the rough opening 1 Pilot holes should be spaced 1 1 2 from interior edges 4 from each corner and then evenly s
11. lumb Test for proper operation remove and reinstall if necessary Note Fastener heads must be flush Do not dent nailing fin Always use pre punched holes or pre drill with a 3 16 bit 4 Fasten window through nailing fin holes 3 7 from the corners and 8 apart all the way around the window RELIABILITY for real life pa A Release corners JELD WEN INSTALLATION INSTRUCTIONS WINDOWS amp DOORS for Vinyl Projecting Windows with Integral Nailing Fin J11023 10 FLASH GARDEN WINDOW PREPARE FLASHING APPLY THE SELF ADHESIVE FLASHING 1 Cut three pieces of self adhesive flashing as follows Note Keep the edge of the self adhesive flashing as close to the e One header piece 12 longer than the header window frame as possible e Two side pieces 7 longer than each side 3 Apply the side pieces starting SPRAY ADHESIVE PRIMER 2 above the Note Protect window from overspray header 2 Apply spray 4 el nag adhesive een e primer as be eT m instructed to i oe the nailing fin eaaer sheathing and m building wrap iis at the sides and p head as shown kka 5 Press the flashing down with a J roller 6 Do not allow gaps or bubbles beneath self adhesive flashing remove and replace if necessary 7 RELIABILITY for real life pa A JELD WEN INSTALLATION INSTRUCTIONS WINDOWS amp DOORS for Vinyl Projecting Windows with Integral Nailing Fin
12. paced no more than 12 around the inside perimeter Drill 1 8 pilot holes and countersink 2 Place window onto the drain mat in the rough opening The window sill must rest on and be fully supported by the rough opening framing 4 PREPARE SILL FOR BAY BOW WINDOW INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin 11023 8 Smooth out any bubbles or creases with a J roller Remove and replace if necessary 9 Install the continuous shim as follows Depth of Note The continuous shim must Ae be 1 2 shorter than the width Cont of the window frame be 1 4 eee narrower than the depth of the window frame sill should level the rough opening sill and be no more than 1 4 thick Align the shim on the sill flush with the exterior and centered between the side jambs If installing a mulled unit leave gaps at the mull joint s so they don t sit on the shim and tack into place or secure with sealant age min Nail fin position 3 Fasten window with a galvanized roofing nail through the nailing fin between 3 and 7 from one lower corner 4 Align side jamb shims with the pre drilled holes so fasteners will penetrate shims Shims must be set back at least 1 4 from the interior of the jamb Secure shims with sealant 5 Inspect window for square level and plumb Test for proper operation remove and reinstall if necessary 6 Using 10 x 3 1 2 pan head screw
13. s fasten the jambs head and seat board through the pre drilled and countersunk pilot holes Screws should penetrate the previously installed shims RELIABILITY for real life pa A JELD WEN WINDOWS amp DOORS INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin J11023 Gg FLASH BAY BOW WIND PREPARE FLASHING 1 Cut four pieces of self adhesive flashing as follows e One head board piece 6 longer than the head board e One header piece 12 longer than the header e Two side pieces 7 longer than each side SPRAY ADHESIVE PRIMER Note Protect window from overspray 2 Apply spray adhesive primer as instructed to nailing fin sheathing and building wrap at the sides and head as shown COMPLETE BAY BOW WINDOW INSTALLATION 1 If the window has a pre installed cable support system follow the instructions provided by the manufacturer 2 If the cable support system is not used build seat board bracing to support at least 750 Ibs of total weight window plus window contents Primary support should be provided under the mull joints of the unit Remove temporary support after full support is installed 4 Release the building wrap from above the header previously taped up and overlap the header flashing Seal the ends with self adhesive flashing or building wrap tape 5 Seal all four corners of the window with a 1 4 bead of sealant Tool into a
14. the applied backing support This backing support should be a non water degradable thin max 1 8 thick sheet material such as vinyl sheeting Completely surround the rough opening with the backing support as shown Backing support must be applied before building wrap RELIABILITY for real life pa A JELD WEN INSTALLATION INSTRUCTIONS WINDOWS amp DOORS for Vinyl Projecting Windows with Integral Nailing Fin 11023 SAFETY WINDOW AND MATERIALS HANDLING SY AND MATERIALS HANDLING e Read and fully understand ALL manufacturers instructions before e Make sure operable windows are closed and locked prior to beginning installation e Do not work alone Two or more people are required Use safe lifting e Heed material manufacturers handling and application instructions techniques e Protect adhesive surfaces from dirt moisture direct sunlight and e Use caution when handling glass Broken or cracked glass can cause folding over onto themselves serous INJULY Handle in vertical position do not carry flat or drag on floor e Wear protective gear e g safety glasses gloves ear protection etc Do not put stress on joints corners or frames e Operate hand power tools safely and follow manufacturer s operating i e Store window in dry well ventilated area in vertical leaning position instructions to allow air circulation do not stack horizontally e Use caution when working at elevated heights e