Home
ZyXEL MC100FX-SC2/30 User's Manual
Contents
1. Check that the Ethernet device supports auto negotiation at half full duplex and 100MBps speed If Link Fault Signaling is enabled DIP switch 5 is on then check if the fiber link is down thereby forcing the Ethernet link down The FDX COL Ethernet LED is off The RJ 45 port is operating in half duplex mode or the Ethernet link is down See above for possible causes and remedies 13 MC100FX SC2 30 A User s Guide PROBLEM POSSIBLE CAUSES AND REMEDIES The LNK ACT Fiber LED is off Check the fiber cable connection between the media converter and the remote device Check that the distance between them does not exceed limits for single mode MC100FX SC30 A or multi mode fiber MC100FX SC2 A Check for faulty cables Check what duplex mode the remote device supports and then set DIP switch 2 FD for full duplex and HD for half duplex If Link Loss Forwarding is enabled DIP switch 5 is on then check if the Ethernet link is down thereby forcing the fiber link down The FDX COL Fiber LED is off The fiber port is operating in half duplex mode or the fiber link is down See above for possible causes and remedies 14
2. 8 x 23 4 mm L x W x H Temperature Operating 0 C to 50 C Storage 20 C to 70 C Humidity Operating 10 to 90 RH Storage 5 to 90 RH EMC FCC Part 15 of Class A amp CE approved 12 MC100FX SC2 30 A User s Guide Chapter 5 Troubleshooting Use the LEDs to identify possible problems and then take corrective action PROBLEM POSSIBLE CAUSES AND REMEDIES The PWR LED Make sure you are using the supplied power adaptor and that it is is off plugged in to an appropriate power source Check that the power source is turned on If the problem persists you may have a hardware problem In this case you should contact your local vendor The 100M LED is off Check if the media converter has a connection with a 10Mbps Ethernet device Check the Ethernet cable connection between the media converter and the Ethernet device The distance between them should not be more than 100 meters Check for faulty Ethernet cables If the connected Ethernet device does not support auto negotiation turn on DIP switch 2 and 3 to force a 100 Mbps full duplex link If Link Fault Signaling is enabled DIP switch 5 is on then check if the fiber link is down thereby forcing the Ethernet link down The LNK ACT Ethernet LED is off Check the Ethernet cable connection between the media converter and the Ethernet device The distance between them should not be more than 100 meters Check for faulty Ethernet cables
3. can be used for distances of up to 30km Use the LEDs to quickly check the status and the DIP switches to set the transmission settings and Link Fault Signaling MC100FX SC2 30 A User s Guide Key Features Each media converter has the following key features e Automatic MDI MDI X selection on RJ 45 port e Link Fault Signaling e Store and forward at full wire speed e Auto negotiation NWay support e Half Full duplex mode selection e Remote and local Loop back Testing via DIP switch e Extends distances to up to 2km 6600 feet with multi mode fiber and up to 30km 99000 feet with long haul single mode fiber e Compatible with other 10Base T amp 100Base TX FX devices e FCC Class A amp CE approved MC100FX SC2 30 A User s Guide Chapter 2 Applications To effectively expand a Fast Ethernet network position two converters back to back as illustrated Application Diagram In the next figure the converter is functioning as a high speed bridge between switches creating increased capacity for each user node on the local area network Switch gt CONVERTER CONVERTER e Switch F ast Ethernet S witcn Fast Ellhernet Swilcn Half Duplex M ut moce 412m Multi mode 2Km Single Mode 30Km a 100M UTP Gams p Fiber Cable Enhane ed 1 01007X to OOF X Conve iter 8i Der 4 Enhanced 101 OUTX to 100FK Cowerer Application Diagram Il In the next figure the converte
4. warning notices and instructions Do NOT use this product near water for example in a wet basement or near a swimming pool Do NOT expose your device to dampness dust or corrosive liquids Do NOT store things on the device Do NOT install use or service this device during a thunderstorm There is a remote risk of electric shock from lightning Connect ONLY suitable accessories to the device Do NOT open the device or unit Opening or removing covers can expose you to dangerous high voltage points or other risks ONLY qualified service personnel should service or disassemble this device Please contact your vendor for further information Make sure to connect the cables to the correct ports Place connecting cables carefully so that no one will step on them or stumble over them Always disconnect all cables from this device before servicing or disassembling Use ONLY an appropriate power adaptor or cord for your device Connect the power adaptor or cord to the right supply voltage for example 110V AC in North America or 230V AC in Europe MC100FX SC2 30 A User s Guide Do NOT allow anything to rest on the power adaptor or cord and do NOT place the product where anyone can walk on the power adaptor or cord Do NOT use the device if the power adaptor or cord is damaged as it might cause electrocution If the power adaptor or cord is damaged remove it from the power outlet Do NOT attempt to repair the power adaptor or co
5. will adjust according to the end node device automatically The RJ 45 connector is suitable for UTP cable of Category 3 4 5 or better 100Base FX port The 100BASE FX port has a fiber Fast Ethernet link to your network device Compliant with IEEE 802 3u this port can transmits data at 100Mbps in full duplex mode across distances of up to 2km over multi mode fiber optic cable and 30km over single mode fiber optic cable The fiber port has SC fiber connectors LED Indicators This Converter has LED indicators located at the front of the device The LEDs have been designed to give at a glance readings of different conditions and provides real time connectivity information Below is an interpretation of their functions Port and Unit LEDs LED Condition Status 100 On Green The port is operating at 100Mbps Off The port is operating at 10Mbps On Green Illuminated when connectors are attached LNK ACT Flashing Green Data traffic passing through port Off No valid link established on port On Amber Port is operating at full duplex FDX COL Flashing Amber Indicates collisions Off Port is operating at half duplex On Green converter is receiving power PWR Off Power off or failure LFS On Red Disruption of connection in copper or fiber segment Off Copper fiber segment is normal MC100FX SC2 30 A User s Guide Link Fault Signaling LFS is a function that is extremely
6. 9 Web Site www zyxel kz Regular Mail ZyXEL Kazakhstan 43 Dostyk ave Office 414 Dostyk Business Centre 050010 Almaty Republic of Kazakhstan North America e Support E mail support zyxel com e Sales E mail sales zyxel com Telephone 1 800 255 4101 1 714 632 0882 Fax 1 714 632 0858 Web Site www us zyxel com FTP Site ftp us zyxel com Regular Mail ZyXEL Communications Inc 1130 N Miller St Anaheim CA 92806 2001 U S A Norway e Support E mail support 2 zyxel no e Sales E mail sales 9 zyxel no Telephone 47 22 80 61 80 Fax 47 22 80 61 81 Web Site www zyxel no Regular Mail ZyXEL Communications A S Nils Hansens vei 13 0667 Oslo Norway Poland E mail info pl zyxel com Telephone 48 22 333 8250 Fax 48 22 333 8251 Web Site www pl zyxel com viii MC100FX SC2 30 A User s Guide Regular Mail ZyXEL Communications ul Okrzei 1A 03 715 Warszawa Poland Russia e Support http zyxel ru support e Sales E mail sales 9 zyxel ru Telephone 7 095 542 89 29 Fax 7 095 542 89 25 Web Site www zyxel ru Regular Mail ZyXEL Russia Ostrovityanova 37a Str Moscow 117279 Russia Spain Support E mail support zyxel es e Sales E mail sales zyxel es Telephone 34 902 195 420 Fax 34 913 005 345 Web Site www zyxel es Regular Mail ZyXEL Communications Arte 21 5 planta 28033 Madrid Spain Sweden e Suppo
7. HD and full duplex FD modes Use DIP switch 3 to manually select between 10Mbps or 100Mbps speeds Set NWay DIP switch to OFF position when connecting to an auto sensing device that only supports 10 100Mbps detection Some older network switches only support the auto sensing of speed and NOT auto detection of speed and duplex mode auto negotiation Important A In order to configure DIP switches 2 duplex mode and 3 speed you must set DIP switch 1 NWay to the OFF position 10 MC100FX SC2 30 A User s Guide Note If you experience the following problems please check if the NWay switch is properly set The LNK link LED is not lit and the connection cannot be established The LNK LED is lit and the connection is good but cannot transmit or receive data 11 MC100FX SC2 30 A User s Guide Chapter 4 Specifications ITEM SPECIFICATION Ethernet and Fiber IEEE 802 3 10BASE T Ethernet IEEE 802 3u Standards 100BASE TX FX Fast Ethernet IEEE 802 3x Flow Control and Back pressure Fiber Transceiver with SC connector Wavelength 4340nm multi mode 1310nm single mode Fiber Distance Multi mode Fiber 2km Single mode Fiber 30km Ethernet Port CAT 5 100Mbps unshielded twisted pair cable Auto crossover MDI MDI X and auto negotiation support LEDs PWR 100 LFS FDX COL LNK ACT Power External adapter 12V DC at minimum 0 8A Dimensions 109 2 x 73
8. MC100FX SC2 A MC100FX SC30 A 100Base TX UTP to 100Base FX Fiber SC Media Converters User s Guide Version 1 0 10 2006 ZyXEL MC100FX SC2 30 A User s Guide Copyright Copyright 2006 by ZyXEL Communications Corporation The contents of this publication may not be reproduced in any part or as a whole transcribed stored in a retrieval system translated into any language or transmitted in any form or by any means electronic mechanical magnetic optical chemical photocopying manual or otherwise without the prior written permission of ZyXEL Communications Corporation Published by ZyXEL Communications Corporation All rights reserved Disclaimer ZyXEL does not assume any liability arising out of the application or use of any products or software described herein Neither does it convey any license under its patent rights nor the patent rights of others ZyXEL further reserves the right to make changes in any products described herein without notice This publication is subject to change without notice Certifications Federal Communications Commission FCC Interference Statement This device complies with Part 15 of FCC rules Operation is subject to the following two conditions This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operations FCC Warning This device has been tested and found to comply with t
9. beneficial in terms of network status monitoring The LFS LED will immediately light to indicate when a cable has been severed or when some other cause of disruption in service has occurred The LFS function monitors both copper and fiber segments giving a total connection status report Set LFS to ON position for normal operational use Set LFS to OFF position when installing cables or when testing the network connection Note The LFS feature influences both fiber and copper segments Therefore when disruption occurs on either segment the LFS feature will be activated and the LED will light to indicate that the entire connection is down Rear Panel The rear panel contains a power port a power LED and DIP Switches Connect the included power adapter 12V DC voltage with minimum 0 8A current to the port labeled 12VDC 800mA and connect the power adaptor to a power supply outlet MC100FX SC2 A OCD uuuuuuu 12V DC 800mA oco 12V DC 800mA MC100FX SC2 30 A User s Guide DIP Switches DIP 1 Enables disables auto negotiation RJ 45 DIP 2 Copper port RJ 45 duplex mode full or half duplex DIP 3 Copper port RJ 45 data bit rate 10Mbps or 100Mbps DIP 4 Fiber port duplex mode full duplex or half duplex DIP 5 Enables disables Link Fault Signaling LFS DIP 6 Enables disables Local Loop back LLB DIP 7 Enables disables Remote Loop back RLB Loop back Testing This Converter features DIP switche
10. ditions Note Repair or replacement as provided under this warranty is the exclusive remedy of the purchaser This warranty is in lieu of all other warranties express or implied including any implied warranty of merchantability or fitness for a particular use or purpose ZyXEL shall in no event be held liable for indirect or consequential damages of any kind to the purchaser To obtain the services of this warranty contact Zy XEL s Service Center for your Return Material Authorization number RMA Products must be returned Postage Prepaid It is recommended that the unit be insured when shipped Any returned products without proof of purchase or those with an out dated warranty will be repaired or replaced at the discretion of ZyXEL and the customer will be billed for parts and labor All repaired or replaced products will be shipped by ZyXEL to the corresponding return address Postage Paid This warranty gives you specific legal rights and you may also have other rights that vary from country to country Registration Register your product online to receive e mail notices of firmware upgrades and information at www zyxel com for global products or at www us zyxel com for North American products MC100FX SC2 30 A User s Guide Table of Contents Chapter 1 Introduction scscssssssscssessssssssssscescsssescsssnesssssscessessescessnessssnescessessssessnessssnessessossossossessoosoes 1 Key Features ione nter eee isasac
11. dransk 621 143 01 Praha 4 vi MC100FX SC2 30 A User s Guide Modrany Ceska Republika Denmark e Support E mail support zyxel dk e Sales E mail sales zyxel dk Telephone 45 39 55 07 00 Fax 45 39 55 07 07 Web Site www zyxel dk Regular Mail ZyXEL Communications A S Columbusvej 2860 Soeborg Denmark Finland e Support E mail support zyxel fi e Sales E mail sales 9 zyxel fi Telephone 358 9 4780 841 1 Fax 358 9 4780 8448 Web Site www zyxel fi Regular Mail ZyXEL Communications Oy Malminkaari 10 00700 Helsinki Finland France e E mail info zyxel fr Telephone 33 4 72 52 97 97 Fax 33 4 72 52 19 20 Web Site www zyxel fr Regular Mail ZyXEL France 1 rue des Vergers Bat 1 C 69760 Limonest France Germany Support E mail support zyxel de Sales E mail sales zyxel de Telephone 49 2405 6909 0 Fax 49 2405 6909 99 Web Site www zyxel de Regular Mail ZyXEL Deutschland GmbH Adenauerstr 20 A2 D 52146 Wuerselen Germany Hungary e Support E mail support zyxel hu vii MC100FX SC2 30 A User s Guide e Sales E mail info zyxel hu Telephone 36 1 3361649 Fax 36 1 3259100 Web Site www zyxel hu Regular Mail ZyXEL Hungary 48 Zoldlomb Str H 1025 Budapest Hungary Kazakhstan e Support http zyxel kz support e Sales E mail sales zyxel kz Telephone 7 3272 590 698 Fax 7 3272 590 68
12. ent it will then display a pass fail result Remote Loop back 1 Test Condition set up to produce an accurate result set switches according to the table below Test Condition DIP Switches 1 2 3 4 5 6 7 Converter A OFF FD 100 FD OFF OFF OFF Converter B OFF FD 100 FD OFF OFF ON MC100FX SC2 30 A User s Guide 2 Launch a loop back or diagnostics testing program and follow the instructions given Typically the instructions will be similar to the following H Enter the number of test messages frame packets to be sent between 1 and 1000 a Click on the START button H The program will send a testing message that will loop in the fiber segment it will then display a pass fail result Note Be sure to deactivate both local and remote loop back test functions for normal converter operations NWay DIP switch Setting Use the NWay DIP switch to activate NWay operations Factory Default NWay DIP switch set to ON position Check that the networking device that will be connected to the Converter supports NWay If YES Check that the NWay DIP switch is set to the ON position The Converter will automatically set the optimum speed and duplex mode on the copper segment Users can skip the settings for DIP switches 2 and 3 when NWay is activated If NO Set the NWay DIP switch to the OFF position Then use DIP switch 2 to manually select between half
13. he limits for a Class A digital switch pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a commercial environment This device generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Taiwanese BSMI Bureau of Standards Metrology and Inspection A Warning MC100FX SC2 30 A User s Guide EEFFERE jee ARRAY Balen Tee esate Ge AIS BASRA IS TEXSTETBIR P ES RSE Se SHS Notices Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada CLASS 1 LASER PRODUCT APPAREIL A LASER DE CLASS 1 PRODUCT COMPLIES WITH 21 CFR 1040 10 AND 1040 11 PRODUIT CONFORME SELON 21 CFR 1040 10 ET 1040 11 Safety Warnings For your safety be sure to read and follow all
14. r is functioning as a server aggregation for an enterprise configuration It is providing a 100Mbps full duplex link to workgroups of 10 100 switches located on separate floors within a single building Switch gt CONVERTER CONVERTER e Server MC100FX SC2 30 A User s Guide Fast Ethernet S witch Haf Duplex Muit mo 412m Server Multi mode 2Km Single Mode 30Km zx m 8I cJ zri v 100M UTP Fiber Ca ble LaL pod Enhanced 1 0100TX to Enhanced 10 100TX to 100F X C anv ener 100F X Cone ler MC100FX SC2 30 A User s Guide Chapter 3 Hardware The media converter can be placed on a desktop Make sure that there is proper heat dissipation from and adequate ventilation around the device Do not place heavy objects on the media converter Front Panel The front panel consists of an RJ 45 port for 100 Mbps UTP connections LED indicators and a built in fiber transceiver with SC connector MC100FX SC2 A LNK ACT LFS ma t E e FDX COL 100 10 100 MC100FX SC30 A LNK ACT LFS FDX COL 100 10 100 MC100FX SC2 30 A User s Guide 100Base TX port The 10 100BASE TX port supports network speeds of either 10Mbps or 100Mbps and can operate in half and full duplex transfer modes This port also offers automatic MDI MDI X crossover detection that gives the device true plug n play capability just plug the network cable into the port and the port
15. rd Contact your local vendor to order a new one Do not use the device outside and make sure all the connections are indoors There is a remote risk of electric shock from lightning Do NOT obstruct the device ventilation slots as insufficient airflow may harm your device This product is recyclable Dispose of it properly MC100FX SC2 30 A User s Guide Viewing Certifications 1 Go to http www zyxel com 2 Select your product on the ZyXEL home page to go to that product s page 3 Select the certification you wish to view from this page ZyXEL Limited Warranty ZyXEL warrants to the original end user purchaser that this product is free from any defects in materials or workmanship for a period of up to two years from the date of purchase During the warranty period and upon proof of purchase should the product have indications of failure due to faulty workmanship and or materials ZyXEL will at its discretion repair or replace the defective products or components without charge for either parts or labor and to whatever extent it shall deem necessary to restore the product or components to proper operating condition Any replacement will consist of a new or re manufactured functionally equivalent product of equal or higher value and will be solely at the discretion of ZyXEL This warranty shall not apply if the product has been modified misused tampered with damaged by an act of God or subjected to abnormal working con
16. rt E mail support zyxel se e Sales E mail sales zyxel se e Telephone 46 31 744 7700 Fax 46 31 744 7701 Web Site www zyxel se Regular Mail ZyXEL Communications A S Sj porten 4 41764 Goteborg Sweden Ukraine e Support E mail support ua zyxel com e Sales E mail salesQua zyxel com Telephone 380 44 247 69 78 Fax 380 44 494 49 32 Web Site www ua zyxel com Regular Mail ZyXEL Ukraine 13 Pimonenko Str Kiev 04050 Ukraine United Kingdom e Support E mail support zyxel co uk e Sales E mail sales zyxel co uk Telephone 44 1344 303044 08707 555779 UK only MC100FX SC2 30 A User s Guide Fax 44 1344 303034 Web Site www zyxel co uk FTP Site ftp zyxel co uk Regular Mail ZyXEL Communications UK Ltd 11 The Courtyard Eastern Road Bracknell Berkshire RG12 2XB United Kingdom UK 4 is the prefix number you dial to make an international telephone call MC100FX SC2 30 A User s Guide Chapter 1 Introduction The MC100FX SC2 30 A media converter allows seamless integration between a Fast Ethernet network using unshielded twisted pair UTP copper cabling and a fiber network The MC100FX SC2 A media converter comes with a built in multimode fiber transceiver module with SC connector that can be used for distances of up to 2km The MC100FX SC30 A media converter comes with a built in single mode fiber transceiver module with SC connector that
17. s for activating local and remote loop back diagnostic test functions Use local loop back to check if the copper segment is connected properly and use remote loop back to check if the fiber segment is connected properly Please see the figure below putt E ra B Copper ComenerA J Fiber COE a n i n TO a ji P E Local Loopback m Remote Loopback Dip Switch 6 ON enables local loop back function OFF disables local loop back function Dip Switch 7 ON enables remote loop back function OFF disables remote loop back function MC100FX SC2 30 A User s Guide Make sure that the cables are connected properly before getting started Conduct either the local or remote test not both at the same time Follow the steps below to perform the diagnostic tests Local Loop back 1 Test Condition set up for an accurate result be sure to set the DIP switches according to the table below Test Condition DIP Switches ES N w A a o N Converter A OFF FD 100 FD OFF ON OFF Converter B OFF FD 100 FD OFF OFF OFF 2 Launch a loop back or diagnostics testing program and follow the instructions given Typically the instructions will be similar to the following Enter the number of test messages frame packets to be sent between 1 and 1000 Click on the START button The program will send a testing message that will loop in the copper segm
18. sete sete stesse sse ease eaae eaae ena 10 Chapt r 4 Specifications T C M 12 Chapter 5 TroubleshoOtiNS 0reveeereoreooooeooooooonooooosoosooooonoooooouooooosooooosoonoooooonooooonoooooooonoooonoooooonoooooooonoooneonoone 13 MC100FX SC2 30 A User s Guide Customer Support Please have the following information ready when you contact customer support Required Information Product model and serial number Warranty Information Date on which you received your device Brief description of the problem and the steps you took to try and solve it Corporate Headquarters Worldwide e Support E mail support zyxel com tw e Sales E mail sales zyxel com tw Telephone 886 3 578 3942 Fax 886 3 578 2439 Web Site www zyxel com www europe zyxel com FTP Site ftp zyxel com ftp europe zyxel com Regular Mail ZyXEL Communications Corp 6 Innovation Road II Science Park Hsinchu 300 Taiwan Costa Rica e Support E mail soporte 2 zyxel co cr e Sales E mail sales zyxel co cr Telephone 506 2017878 Fax 506 2015098 Web Site www zyxel co cr FTP Site ftp zyxel co cr Regular Mail ZyXEL Costa Rica Plaza Roble Escaz Etapa El Patio Tercer Piso San Jos Costa Rica Czech Republic e E mail info cz zyxel com Telephone 420 241 091 350 Fax 420 241 091 359 Web Site www zyxel cz Regular Mail ZyXEL Communications Czech s r o Mo
19. tacuecenasiisn rO EE O OSa aiae EE STEED aeee 2 Chapter 2ApplicationS osise oseese e eoio aae 3 Application Diagram 1 ssscssscsssssssscsscsscescsssessessnessssnsscsssssescesenesessnessessescossessnssessnessessesssssnesessnesseseoss 3 Application Diagram II 0 00e0reteeoreoooooooonoooooouooooesoooooooonoooooonooooouoooooooonooooonoooooonooooosoooooooonooonoooooooonoooooonooo 3 Chapter 3 Hard ware eere eter creeiv certes aree eae ri oTi ae eeo VE rU rH E eee absan Eo Sorn URS o s v asosi sssosossossos pne ela 5 Front Panel 5 LOO BASE TX POV MEC eS 6 T00Base FX qon P R 6 LED Indic toEs 5 0 0 ou e bi au akou ok dou koka as ke oaea Ean Si kiy aka eU ape e av aa so aaa d done po kodak ETT 6 Link Fault Signaling sissies c H 7 Rear Panel e de n eO 7 DIPS Witches io iiit ue onde so padon kan oua do ko a diou anite s y sepe S so kou ea e a balucaves dp ei yon D pi rou ansan edad 8 LEoop back Testing einen iere hotte do po s tp etit eese 1 ol Ces d eaa rE be s soul bo sena d sayo RU bo ong ea Rab eade 8 Local LOOp Dack e 9 Remote Loop baCk dee M Q 9 NWay DIP switch Setting 4 cree eee eee eee eese eene eee ette essen setas etna etn setas etas eta