1. the box and the rough opening Apply caulk to any holes in the box around wires etc Step 3 When installing siding cut a hole just large enough for the Rough In box opening Caution Too large of a hole can cause plate misalignment and compromise the gasket seal Note When mounting to 4 inch or less horizontal lap siding the unit can be mounted horizontally flush against siding or a siding mounting block can be used recommended with vinyl siding Contact siding installer for the correct mounting block B Old Work Remodel Flush Mounting Recommended Rough In box Allied Molded 9331 Step 1 Make sure mounting location is free of wall studs wires etc Step 2 Place Rough In box LEVEL against siding Trace outline of box onto siding Note When mounting to 4 inch or less horizontal lap siding the unit can be mounted horizontally flush against siding or a siding mounting block can be used Contact your siding Installer for the correct mounting block part number Note A siding mounting block is recommended when mounting to vinyl siding Step 3 Cut a hole through the siding and wall sheathing just large enough for the rough in box Caution Too large of a hole can cause plate misalignment and compromise the gasket seal Step 4 The front surface of the Rough In box can be mounted flush against wood siding or can be recessed and mounted flush against wall sheathing when mounting on aluminum steel or vinyl siding Step 5 When mountin
2. A INSTALLATION INSTRUCTIONS DCSS DCCBB Doorbell Communicator DESCRIPTION The DCSS DCCBB is a Doorbell Communicator that is used with the DCH4 to provide keyless entry control with the MRC88CTL The DCSS is a stainless steel version The DCCBB is a cool bronzed black version Both DCSS and DCCBB mount into a single gang box SPECIFICATIONS Power Telephone line powered 18VDC 20mA minimum Dimensions o Faceplate 123 8mm x 79 4mm x 4 6mm 4 875 x 3 125 x 0 18 o Phone 71mm x 46mm x 42mm 2 8 x 1 8 x 1 65 Shipping Weight 0 45 kg 1 0 Ibs Environmental 32C to 54C 25F to 130F with 5 to 95 non condensing humidity Speaker Volume Approximately 62dB maximum 1m Ring Voltage 25VAC RMS minimum for auto answer CPC Disconnect Time 300ms minimum REN 0 8A Connections 2 gel filled butt connectors 08905108C 1 INSTRUCTIONS The DCSS DCCBB is designed to be flush mounted into a standard single gang Rough In box with a minimum inside dimension of 1 70 deep x 2 00 wide x 2 84 tall A New Construction Flush Mounting Step 1 Front of box should stick out approximately 1 2 from front surface of wall stud this may vary depending on the walls sheathing and siding thickness Caution Rough In box must be mounted LEVEL and must NOT stick out beyond the front surface of siding Step 2 To maintain a vapor barrier on outside wall applications caulk around the box filling any gaps between
3. dures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make the necessary modifications to maintain uninterrupted service If trouble is experienced with the DCSS DCCBB for repair or warranty information please contact XANTECH CORPORATION 13100 TELFAIR AVE SYLMAR CA 91342 818 362 0353 If the equipment is causing harm to the telephone network the telephone company may request that you disconnect the equipment until the problem is resolved Connection to Party Line Service is subject to State Tariffs Contact the state public utility commission public service commission or corporation commission for information WHEN PROGRAMMING EMERGENCY NUMBERS AND OR MAKING TEST CALLS TO EMERGENCY NUMBERS Remain on the line and briefly explain to the dispatcher the reason for the call Perform such activities in the off peak hours such as early morning or late evenings It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected This is to avoid damaging the equipment caused by local lightning strikes and other electrical surges PART 15 LIMITATIONS This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commerc
4. g to 5 8 inch thick or less wall sheathing the two attached screws with wing brackets can be used to secure the rough in box When mounting to surfaces thicker than 5 8 inch four standard flat head dry wall screws can be used to secure the Rough In box through its mounting ears Step 6 To maintain a vapor barrier on outside wall applications caulk around the box filling any gaps between the box and the rough opening Apply caulk to any holes in the box around wires etc WARNING Do not use a Wet Location Box 08905108C SOs n 325 Z Opeonal Canticrad Wing Mounting Ears T Braes z bi OOS la lO g _ a ua o E zx 2 Gel Filled a Butt Gonrmacbhoers Fa h jine lugded i j i ee Rad eoo d 4 875 a pan ne mps a g a a e ere re ee ee a E S E is is Se ne i EFE oe oF H Gphanal Dry aia an Aaa ores parE a prat i h al Old Work Rough 4in Box st nshesed pep Sze 4 4 Thick Foam Facplate Se ree fireciud add Allied Molded 331 box Mounting Plate Sas iad Faceplate Gasket included shown not inchuced included fincluded A Adjusting Speaker Volume The speaker volume pot can be adjusted to increase Microphone or decrease the speaker volume to the level desired Soumi see section B Speaker Volume see section A B Adjusting the Microphone Volume 4 J 22J52 Eh annn pennn In certain noisy locations background traffic i Bs P machinery or wind the microph
5. ial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense xantecn Xantech Corporation 13100 Telfair Avenue 2 F Sylmar CA 91342 Installation Instructions DCSS DCCBB 2007 Xantech Corporation Document 089051 08C This document is copyright protected No part of this manual may be copied or reproduced in any form without prior written consent from Xantech Corporation Xantech Corporation shall not be liable for operational technical or editorial errors omissions made in this document 08905108C 4
6. not ringing in response to an incoming call In most but not all areas the sum of the REN s should not exceed five 5 0 To be certain of the number of devices that may be connected to a line as determined by the total REN s contact the local telephone company For products approved after July 23 2001 the REN for this product is part of the product identifier that has the format US AAAEQ TXXXxX The digits represented by are the REN without a decimal point e g 03 is a REN of 0 3 For earlier products the REN is separately shown on the label The plug used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA If your home has specially wired alarm equipment connected to the telephone line ensure the installation of this DCSS DCCBB does not disable your alarm equipment If you have questions about what will disable alarm equipment consult your telephone company or a qualified installer If the DCSS DCCBB causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment operations or proce
7. one volume may e ree need to be decreased A symptom of this is one way gt talk path in which the distant party cannot be heard e T cH over the speaker A microphone volume pot is EPA EA provided for increasing or decreasing the m microphone volume Note If the microphone volume is set too high or too low one way talk path may occur b a TEN ETEIRUEI aan ecoooof C Call Length Time Out This feature limits the maximum length of time that calls can be connected to 5 minutes D Silence Time Out This feature limits the length of time that calls will remain connected without voice activity to 40 seconds OPERATIONS When the push button is pressed the DCSS DCCBB phone goes off hook much like a standard speaker phone In the event that the line is busy the DOSS DCCBB will hang up The DCSS DCCBB will also automatically hang up on CPC silence busy signal return to dial tone or time out The DCSS DCCBB will also answer any incoming call 08905108C 3 FCC REQUIREMENTS This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA On the side of this equipment is a label that contains among other information a product identifier in the format US AAAEQ TXXXxX If requested this number must be provided to the telephone company The REN is used to determine the number of devices that may be connected to a telephone line Excessive REN s on a telephone line may result in the devices