Home
Wolf IM15 User's Manual
Contents
1. CoE AMM op TI NIPPLE FLEXIBLE NIPPLE METAL CONNECTOR Multi Function Cooktop Installation Install the Cooktop COMPLETE THE INSTALLATION Once the multi function cooktop has been checked for gas leaks plug the power cord into the grounded electri cal outlet Place the burner head on the burner base and position the burner grate over the burner assembiv Read the entire Wolf multi function cooktop use amp care guide included with the unit It contains important safetv operation service and warrantv information Before operating clean the multi function cooktop thor oughiv with hot water and a mild detergent Rinse and drv with a soft cloth This removes any residual oil and grease left on the surface from the manufacturing process Refer to care recommendations in the use amp care guide 12 VERIFV OPERATION The burner of the gas multi function cooktop uses an electronic igniter in place of a standing pilot When the control knob is pushed in and turned to the HIGH position the svstem creates a spark to light the burner This sparking continues until the electronic ignition senses a flame To check operation of the burner push in and turn the control knob to the HIGH position The flame should light within four seconds If the burner does not light properlv turn the control knob to the OFF position Check that the burner head is in the proper position Make
2. Standard orifices are set for 5 12 5 mb WC water column LP Gas Standard orifices are set for 10 25 mb WC Gas Supply Pressure The maximum gas supply pressure to the regulator should never exceed 14 34 9 mb WC 5 psi 3 5 kPa for natural and LP gas The minimum line pressure is 7 17 5 mb WC for natural gas and 11 27 4 mb WC for LP gas Gas Pressure Regulator To control and maintain a uniform gas pressure in the gas manifold the unit must be used with a gas pressure regulator The burner orifices etc are sized for the gas pressure delivered bv the supplied regulator Do not remove the regulator wolfappliance com specs A CAUTION The maximum gas supply pressure to the regulator should never exceed 14 34 9 mb WC 5 psi 3 5 kPa Multi Function Cooktop Specifications Electrical Requirements ELECTRICAL SHOCK HAZARD Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Failure to follow these instructions can result in electric shock fire or death The Wolf multi function cooktop requires a 120 VAC 60 Hz 15 amp fused electrical supply A time delay fuse or circuit breaker is recommended It is recommended that a separate circuit serving only this appliance be provided A ground fault circuit interrupter GFCI is not recom mended and may cause interruption of operation ELECTRICAL GROUND The 6 1 8 m power cord is equipped with a 3 prong grounding plug
3. Using a pencil outline the rear edge of the cooktop frame on the countertop Remove the cooktop from the countertop opening IMPORTANT NOTE When repositioning the multi function cooktop in the countertop opening lift the entire cooktop up from the opening to prevent scratching the countertop Apply the foam strip included in the hardware package to the underside of the multi function cooktop frame Refer to the illustration below Reinsert the multi function cooktop into the countertop opening Align the rear edge of the cooktop frame with the pencil line and check that it is parallel to the front edge of the countertop Lift the entire cooktop to make adjust ments COUNTERTOP Sm BURNER BOX FOAM STRIP BURNER BOX BRACKET 31 2 89 CLAMPING SCREW CLIP Foam strip Installation brackets 10 Attach the brackets to the burner box by inserting the clips into the rectangular punchouts on the left and right side of the burner box Insert the 31 2 89 clamping screws into the brackets Use a screwdriver to tighten the clamping screws against the underside of the countertop Refer to the illustration below Do not overtighten screws IMPORTANT NOTE Do not seal the cooktop to the coun tertop It must be removed if service is necessary Multi Function Cooktop Installation Install the Cooktop GAS PRESSURE REGULATOR Install the gas pressure regulator with the arrow
4. countertop cut out width Dimensions include the filler strip When multiple cooktops are installed side bv side each unit must have its own separate recommended electrical circuit When multiple gas cooktops are installed next to one another thev can receive their gas supplv from a common line However each unit must have its own gas pressure regulator When two or more cooktops or modules are installed together an integrated module filler strip is recommended The filler strip and other accessories are available through vour authorized Wolf dealer For local dealer information visit the find a showroom section of our website wolfappliance com IMPORTANT NOTE Review specific installation instruc tions for product to product capabilities wolfappliance com specs Multiple Cooktops COUNTERTOP CUT OUT 2 Modules 3 Modules 4 Modules 30 762 Cooktop Module 30 762 Cooktop 2 Modules 36 914 Cooktop Module WIDTH 291 4 743 441 2 1130 593 4 1518 441 4 1124 591 2 1511 501 4 1276 Multi Function Cooktop Installation Install the Cooktop Remove the multi function cooktop and gas pressure regulator from its shipping carton and discard packing materials Lower the multi function cooktop into the countertop cut out opening Center the cooktop in the opening and check that the front edge of cooktop is parallel to the front edge of the countertop Check that all required clearances are met
5. for protection against shock hazard The power cord must be plugged into a mating 3 prong grounded outlet grounded to conform with the National Electrical Code ANSI NFPA 70 latest edition or Canadian Electrical Code CSA and all local codes and ordinances Refer to the illustration below IMPORTANT NOTE This appliance must be properly grounded to avoid electrical shock hazard Do not ground to a gas pipe GROUNDING GROUNDED ELECTRICAL OUTLET Electrical ground IMPORTANT NOTE Electronic ignition systems operate within wide voltage limits but proper ground and polarity are necessary In addition to checking that the electrical outlet provides 120 VAC power and is correctly grounded the outlet must be checked by a qualified electrician to see if it is wired with correct polarity WIRING DIAGRAM The wiring diagram below covers the control circuit for the Wolf multi function cooktop SAE WHITE CONDUCTOR MODULE ki WHITE POWER CORD N 1j1 IBLK A 2j2 GRN BLACK Wiring diagram Multi Function Cooktop Specifications 9 Installation Specifications MULTIPLE COOKTOP INSTALLATION If the multi function cooktop is to be used in combination with additional cooktops or modules with a filler strip refer to the chart below for the countertop cut out width The dimensions are derived bv adding an additional 11 a 82 for each additional unit to give vou the total
6. on the regulator pointing up toward the unit and in a position where you can reach the access cap Refer to the illustra tion below IMPORTANT NOTE All connections must be wrench tight ened Do not make connections to the regulator too tight as this may crack the regulator and cause a gas leak Do not allow the regulator to turn on the pipe when tightening fittings COOKTOP Gas pressure regulator 11 wolfappliance com specs GAS SUPPLY CONNECTION Assemble the flexible metal connector from the gas supply pipe to the gas pressure regulator You will need to deter mine the fittings required depending on the size of your gas supply line flexible metal connector and shut off valve Refer to the illustration below Use a pipe joint compound made for use with natural and LP gas If a flexible metal connector is used be sure the tubing is not kinked Open the gas shut off valve in the gas supply line Wait a few minutes for the gas to move through the line Refer to the illustration on page 6 GAS LEAK TESTING Use a brush and liquid detergent to test all gas connec tions for leaks Bubbles around connections will indicate a leak If a leak appears shut off the gas supply and adjust connections Then check connections again Clean the detergent solution from the cooktop A WARNING Never test for a gas leak with a match or other flame SHUT OFF GAS PRESSURE VALVE REGULATOR ADAPTER ADAPTER
7. plumber or gasfitter qualified or licensed by the state province or region where this appliance is being installed Only use gas shut off valves approved for use within the state province or region where this appliance is being installed A flexible gas connector when used must not exceed 3 9 m WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance e Do not touch any electrical switch e Do not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department Multi Function Cooktop Specifications Overall Dimensions MULTI FUNCTION COOKTOP 1 2 3 SIDES 1 25 FRONT BACK Installation Specifications A WARNING Failure to locate the multi function cooktop without the proper clearances will result in a fire hazard IMPORTANT NOTE Installation of the Wolf gas multi function cooktop must meet minimum clearance require ments shown in the installation specifications illustration on the following page The Wolf multi function cooktop is intended for indoor use An adequate supply of fresh air is required to assure proper combustion and ventilation It is designed to fit a standard 24 610 deep base cabinet with 25 635 deep countertop Before making the countertop cut out verify that the module will clear the side walls of the base cabinet There
8. should be at least 51 2 140 clearance between the countertop and any combustible surface directly below the multi function cooktop If the multi function cooktop is not installed above an oven the gas service may be supplied through the floor When an oven is installed below the cooktop unless you are using cabinets deeper than 24 610 it is recom mended that the electrical supply be placed in the base cabinet to the right of the oven Refer to the illustration on the following page for specifics on placement of the electrical and gas supply It is recommended that you use a Wolf cooktop ventilation hood downdraft pro hood or hood liner with the multi function cooktop Refer to the Wolf design guide Multi Function Cooktop Specifications Installation Specifications MULTI FUNCTION COOKTOP COUNTERTOP SIDE CABINET P 30 762 min 13 330 COUNTERTOP ESR TO COMBUSTIBLE MATERIALS 18 457 min SEE COUNTERTOP 7 178 TO lt 7 178 TO CUT OUT BELOW COMBUSTIBLE COMBUSTIBLE E TT 4 102 36 914 E 15 FLOOR TO 381 LOCATION OF GAS AND ELECTRICAL EXTENDS ON FLOOR lt 15 381 gt y p 127 SIDE VIEW FRONT VIEW Minimum clearance from cooktop cut out to combustible material
9. sure the power cord is plugged in and the circuit breaker or house fuse has not blown Check that the gas shut off valve is in the open position Check operation again if the burner does not light properly at this point contact Wolf factorv certified service IMPORTANT NOTE Initial lighting of the burner may take slightiv longer as air in the svstem must be purged before gas can be supplied to the burner Multi Function Cooktop Installation Cooktop Removal The multi function cooktop must be disconnected from the electrical and gas supplv prior to removal IMPORTANT NOTE Removal of the multi function cooktop should oniv be performed bv Wolf factorv certified service If removing the multi function cooktop is necessarv for cleaning or service shut off the gas supplv Disconnect the electrical and gas supplv Remove the mounting brackets on each side of cooktop and remove Reinstall in the reverse order and check gas connections for leaks 13 wolfappliance com specs Troubleshooting IMPORTANT NOTE If the multi function cooktop does not operate properly follow these troubleshooting steps e Verify that electrical power is being supplied to the cooktop e Check the gas supply and electrical connections to ensure that the installation has been completed correctly e Check that the gas supply shut off valve is in the open position e Check polarity of the electrical outlet if excessive igniter clicking occurs immedi
10. INSTALLATION GUIDE Multi Function Cooktop LUOLF Contents Wolf Multi Function Cooktop 3 Multi Function Cooktop Specifications 4 Multi Function Cooktop Installation 8 Service lnformation 10 Features and specifications are subject to change at any time without notice Visit wolfappliance com specs for the most up to date information IMPORTANT NOTE Throughout this guide dimensions in parentheses are millimeters unless otherwise specified Important Note To ensure the safe and efficient use of Wolf equipment please take note of the following types of highlighted information throughout this guide IMPORTANT NOTE highlights information that is especially important CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed WARNING states a hazard that may cause serious injury or death if precautions are not followed IIOLF Wolf Multi Function Cooktop Multi Function Cooktop Installation IMPORTANT NOTE Installation of the Wolf gas multi function cooktop must be completed bv a qualified installer Read this entire installation guide prior to installation and save for the local inspector s reference The homeowner should keep this installation guide for future reference This appliance must be installed in accordance with National Electrical Codes as well as all state municipal and loc
11. SUPPLY RATING PLATE Location of rating plate Gas shut off valve GAS SUPPLY LINE IMPORTANT NOTE The gas multi function cooktop must be connected to a regulated gas supply A gas supply line of 3 4 19 rigid pipe must be provided to the cooktop For LP gas piping or tubing size can be 1 2 13 minimum LP gas suppliers usually determine the size and materials used on the system If local codes permit a certified 1 2 13 or 3 4 19 ID flexible metal appliance connector is recommended to connect the cooktop to the gas supply line The gas pressure regulator on the cooktop has 1 2 13 female threads IMPORTANT NOTE The supply line must be equipped with an approved external gas shut off valve located near the cooktop in an accessible location Do not block access to the shut off valve Refer to the illustration below The Wolf natural gas multi function cooktop will function up to an altitude of 10 250 3124 m without any adjust ment LP gas cooktops will function up to 8 600 2621 m without adjustment If the installation exceeds these eleva tions contact your authorized Wolf dealer for a high altitude conversion kit A CAUTION Before connecting the gas supply make sure all valves are in a closed position Do not connect the gas supply to an appliance that shows anv sign of damage Multi Function Cooktop Specifications 7 Gas Supply Requirements GAS MANIFOLD PRESSURE Natural Gas
12. al codes The correct voltage frequency and amperage must be supplied to the appliance from a dedi cated grounded circuit which is protected by a properly sized circuit breaker or time delav fuse The proper voltage frequencv and amperage ratings are listed on the product rating plate The Wolf multi function cooktop is manufactured for use with natural gas or LP gas Check the product rating plate for tvpe of gas Record the model and serial numbers before installing the multi function cooktop Both numbers are listed on the product rating plate located on the underside of the module Refer to the illustration below Wolf Multi Function Cooktop Model Number IM15 S Serial Number RATING PLATE Location of rating plate 3 wolfappliance com specs IMPORTANT INSTRUCTIONS If the information in this guide is not followed exactiv a fire or explosion mav result causing propertv damage personal injurv or death e Installation and service must be performed by a qualified installer service agencv or the gas supplier e Warranty service must be performed by Wolf factory certified service e Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance e A ventilation hood or downdraft system is recom mended for use with the multi function cooktop e In Massachusetts Installations and repairs must be performed by a qualified or licensed contractor
13. ately after installation e Follow troubleshooting procedures outlined in the Wolf gas multi function cooktop use amp care guide e If the multi function cooktop still does not operate properly contact Wolf factory certified service Do not attempt to repair the cooktop yourself Wolf is not responsible for service required to correct a faulty installation Service Information Service Information If service is necessary maintain the quality built into your multi function cooktop by contacting Wolf factory certified service For the name and number of Wolf factory certified service nearest you check the contact amp support section of our website wolfappliance com or call Wolf customer care at 800 222 7820 When calling for service you will need the model and serial numbers of the multi function cooktop Both numbers are listed on the product rating plate located on the underside of the cooktop Refer to the illustration for the location of the rating plate IMPORTANT NOTE Installation and service must be performed by a qualified installer or service agency Warranty service must be performed by Wolf factory certified service 14 RATING PLATE Location of rating plate LUOLF The information and images in this guide are the copvright propertv of Wolf Appliance Inc Neither this guide nor anv information or images contained herein mav be copied or used in whole or in part without the express written pe
14. rmission of Wolf Appliance Inc OWolf Appliance Inc all rights reserved Wolf Wolf amp Design Wolf Gourmet W 8 Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance Inc Sub Zero Sub Zero amp Design Dual Refrigeration Constant Care and The Living Kitchen are registered trademarks and service marks of Sub Zero Inc collectively the Company Marks All other trademarks or registered trademarks are property of their respective owners in the United States and other countries LUOLF WOLF APPLIANCE INC P O BOX 44848 MADISON WI 53744 WOLFAPPLIANCE COM_ 800 222 7820
15. s up to 18 457 above countertop NOTE Application shown allows for installation of two 15 381 modules side by side gt 14 356 CUT OUT WIDTH 21 2 64 min FRONT A 191 4 489 CUT OUT DEPTH Y 21 2 64 min COUNTERTOP CUT OUT A 5 wolfappliance com specs Multi Function Cooktop Specifications Gas Supply Requirements EXPLOSION HAZARD Use a certified gas supply line and install a gas shut off valve Securelv tighten all gas connections Failure to follow these instructions can result in explosion fire or death IMPORTANT NOTE This installation must conform with local codes and ordinances In the absence of local codes installations must conform with American National Standard National Fuel Gas Code ANSI 2223 1 latest edition or CANI B149 1 or 2 The gas multi function cooktop is equipped for use with natural or LP gas It is design certified by the Canadian Standards Association CSA for natural or LP gases The product rating plate located on the underside of the cooktop has information on the type of gas that should be used Refer to the illustration below If this information does not agree with the type of gas available contact your authorized Wolf dealer or local gas supplier For local dealer information visit the find a showroom section of our website wolfappliance com SHUT OFF VALVE OPEN POSITION TO APPLIANCE GAS
Download Pdf Manuals
Related Search
Related Contents
Tischmischer MM-1, MM-2, MM-3 Manual de Usuario Istruzioni d`uso VAI6 mono 025 035 050 065 Dimensione 12202015-ft carbovet 製品安全データシート PSP-2000 TA-085 SM-PSP-3083E-01 BOARD SERVICE MANUAL ECE R44/04 富士メディカルドライレーザーイメージャ DRYPIX 4000 Betriebs- und Montageanleitung für Universalgebersystem U-ONE i-Power - CyberLink Copyright © All rights reserved.