Home
Winegard RA-7296 User's Manual
Contents
1. ONNECTIONS Non Amplified Antenna Outdoor Receptacle WA 1010 TV Outlet Cable Input Antenna Input Cable Input ON OFF Switch Set 1 Example 1 WARNING Do not connect high current devices such as hair dryers to 12 volt receptacle on wall plate amplifier Maximum currentratings of this receptacle is 7 5 amps at 12 VDC Non Amplified Outdoor Receptacle Antenna WA 1010 a e Antenna Input TG 7221 ON OFF Switch Set 1 Example 2 Non Amplified Antenna Outdoor Receptacle WA 1010 TV 1030 Splitter TG 7221 ON OFF Switch Set Example 3 INSTRUCTIONS STEP 1 Select location for wall plate and outdoor receptacle Run two coax cables RG 59 type between locations and install connectors on each end Mark cables so cable input and TV output may be identified Antenna downlead and 12 VDC will also be needed at inside wall plate amplifier location STEP 2 Refer to outdoor receptacle instruction sheet on how to install cables and receptacle Make sure jack on outdoor receptacle marked CABLE INPUT is attached to cable going to jack marked CABLE on indoor wall plate ampilifier STEP 3 The wall plate amplifier assembly may be flush mounted in most standard electrical boxes To flush mount cut a hole in wall to fit the box Run 2 12 wires between wall plate amplifier and 12 VDC source and route downlead cable to this location Install cable between set 2 outlet a
2. R PERIOD OF THIS WARRANTY In states that do not allow limitations on implied warranties or the exclusion of limitation of incidental or consequential damages the above limitations or exclu sions do not apply Some states do not allow limitations on how long an implied warranty lasts or the exclusion of limitation of incidental or consequential damages so the above limita tions or exclusions may not apply to you This warranty gives Customer specific legal rights Customer may also have oth er rights that may vary from state to state SATELLITE RECEIVER WARRANTY See manufacturer s limited warranty policy WS MOBWARREV2 Rev 1 10 Printed in U S A 2451489 Rev 1 10 INSTRUCTIONS v WINEGARD MODEL RA 7296 Made in U S A RV WALL PLATE AMPLIFIER DESCRIPTION Wall plate amplifier amplifies VHF UHF TV signals received by non amplified Winegard RV antennas with outdoor receptacle for TV set and cable input Wall plate amplifier provides a 12 Volt receptacle as well as antenna signals to two TV sets Cable input from outdoor receptacle connects to wall plate and may be switched so either antenna or cable signals may be watched See applications Available in white only NOTE THIS UNIT IS AN AMPLIFIER USE ONLY WITH NON AMPLIFIED RV ANTENNAS WINEGARD COMPANY 3000 KIRKWOOD ST BURLINGTON IA 52601 2000 WARNING Use this amplifier switch with only non amplified RV antennas APPLICATIONS AND ALTERNATE C
3. STEP 5 Install connectors on downlead and set 2 cable as shown in Figure 5 Attach downlead cable to jack on wallplate amplifier marked antenna as shown in Figure 4 Attach cable going to set 2 outlet to jack on power supply marked SET 2 Attach cable coming from cable input to jack on power supply marked CABLE Antenna FIGURE 4 Cable STEP 6 Mount wall plate amplifier in wall with screws provided and attach TV set cable to jack on front Connect TV set cable to input jack on TV Press switch on front of outlet and check that light is on OPERATION To receive cable signals from outdoor receptacle Press switch to OFF position Light on wallplate will go OFF showing that power is no longer connected to the amplifier and that both TV sets are receiving signals from outdoor receptacle To receive signals from antenna Press switch to ON position Light on wallplate will come ON showing that power is connected to the amplifier and both TV sets are receiving signals from the antenna NOTE Make sure the antennais in the operating position up and pointed at the station desired INSTALLING FC 5910 CONNECTORS ON COAX CABLE 1 2 e 1 Inner Insulation Outer Cover a gt jews 2 Center Conductor Crimp Here FIGURE 5 Step 1 Strip outer cover back 1 2 from end of cable Fray braid back as far as outer cover will allow S
4. fication of the product as originally manufactured by Winegard in any manner whatsoever removing or defacing any serial number usage not in accordance with product instructions or acts of nature such as damage caused by wind lightning ice or corrosive environments such as salt spray and acid rain This Limited Warranty also does not apply if the product becomes unable to perform its intended function in any way as a result of the television signal provider making any changes in technology or service RETURN AUTHORIZATION POLICY A Return Material Authorization RMA is required prior to returning any product to Winegard Company or Winegard Warranty Services under this warranty policy Please call our Technical Services Department at 800 788 4417 or send an e mail to warranty winegard com to obtain the RMA number Please furnish the date of purchase when requesting an RMA number Enclose the product in a prepaid package and write the RMA number in large clear letters on the outside of the package To avoid confusion or misunderstanding a shipment s without an RMA number s or an unauthorized return s will be refused and returned to Customer freight collect WINEGARD COMPANY DOES NOT ASSUME ANY LIABILITIES FOR ANY OTHER WARRANTIES EXPRESS OR IMPLIED MADE BY ANY OTHER PER SON ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STATUTO RY INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY ARE LIMITED TO THE TWO YEA
5. nd power supply location at this time WHEN CONNECTING CABLE OR WIRES BE SURE SWITCH IS IN OFF POSITION STEP 4 Install terminals on wires from 12 VDC source as shown in Figure 1 Crimp terminals with Craftsman type 4 crimping tool or equivalent See Figure 1 Push wires onto tabs on terminal board as shown in Figure 2 If in doubt as to the polarity of the wires connect them temporarily to tabs on circuit board and press switch on front of outlet If light comes on polarity is correct See Figure 3 Crimp Here Connector Ferrule eres aot Connector a Remove 1 4 of Insulation insulation from 12 wire FIGURE 1 12 VDC TE Ground Ke aN AD Ns FIGURE 2 ee WARNING DO NOT connect high current devices such as hair dryers to this receptacle Maximum current rating of this receptacle is 7 5 amps at WINEGARD 12 VDC FIGURE 3
6. te of manufacture If a defect in material or workmanship is discovered Customer may take the product to an authorized Winegard dealer for service Customer must provide proof of purchase to verify the product is under warranty If the product is brought to an authorized Winegard dealer for service prior to expiration of year one 1 of the warranty period and a defect in material or workmanship is verified by Winegard Technical Services Winegard Company will cover the Winegard dealer s labor charges for warranty service The Winegard dealer must contact Winegard Tech nical Services in advance for pre approval of the service Approval of the service is at the sole discretion of Winegard Company Alternatively Customer may ship the product prepaid to Winegard Technical Ser vices located at 3111 Kirkwood Street Burlington lowa 52601 Telephone 800 788 4417 Customer must return the product along with a brief description of the problem and provide Winegard Technical Services with Customer s name ad dress and phone number Customer must also provide proof of purchase to verify the product is under warranty If the product is returned before the expiration of the warranty period Winegard Company will at its option either repair or replace the product This Limited Warranty does not apply if the product has been damaged deterio rates malfunctions or fails from improper installation misuse abuse neglect ac cident tampering modi
7. tep 2 Trim braid close to outer cover and remove 1 4 of inner insulation being careful not to nick center conductor Make sure no foil or braid can touch center conductor Step 3 Slide connector tip between braid and inner insulation braid and foil on foil shield cable and push connector on cable as far as it will go Crimp built in ferrule with proper crimping tool Hex connector requires hex crimping tool Do Not crush cable out of round If installing in very hot weather increase dimensions 1 8 WINEGARD MOBILE PRODUCTS LIMITED WARRANTY 2 YEARS PARTS 1 YEAR LABOR Winegard Company warrants this product against defects in materials or workmanship for a period of two 2 years from the date of original purchase During year one 1 of such warranty Winegard Company will also pay authorized labor costs to an authorized Winegard dealer to repair or replace defective products No warranty claim will be honored unless at the time the claim is made Customer presents proof of purchase to an authorized Winegard dealer to locate the nearest authorized Winegard dealer contact Winegard Company 3000 Kirkwood Street Burlington lowa 52601 Telephone 800 288 8094 or visit www winegard com Customer must provide proof of purchase with a dated sales receipt for the Winegard product to verify the product is under warranty If the date of purchase cannot be verified the warranty period shall be considered to begin thirty 30 days after the da
Download Pdf Manuals
Related Search
Related Contents
29 août - 6 décembre 2014 - États généraux du Parti Socialiste USER`S MANUAL User manual - Waterproof TV hallucinations auditives - Collège National d`Audioprothèse Copyright © All rights reserved.
Failed to retrieve file