White Rodgers UV100 Instruction Sheet
Contents
1. Multi Voltage Electronic Ballast 120 240V e Straight and Angle Mount Brackets e Power Switch and External Fuse e 5 Year Warranty 1 Year Bulb Warranty e Meets UL Safety Standards See back for detailed agency listings VV U J N gt va J C Uj J U pj UV100 UV200 The UV100 single lamp emits light at 253 7 In homes that place higher demands on air nanometers the optimum light frequency in conditioning units the UV200 dual lamp offers double combating the bacteria that commonly infest air the intensity and twice the power to neutralize air conditioners Placed directly above the unit s coils the pollutants And because this unit features increased UV100 halts existing growth and prevents recurrence area coverage it s a smart choice for homes and Sizing Suitable for slab coil applications of three tons businesses that employ larger cooling systems and 1200 CFM or less or where space permits only a Sizing Suitable for slab coil A coil and return air single lamp applications or where space allows dual lamps Model UV100 67 3 L x11 1 s W x 2 16 H 120V 240V 50 60Hz 1PH 3 amp 250V fuse 45 F 150 F outside of duct Ti a Ibs Model UV200 67 3 L x143 16 W x 2 16 H 6 3 4 Ibs 120V 240V 50 60Hz 1PH 3 amp 250V fuse 45 F 150 F outside of duct 4 amp EMERSON Climate Technologies Specifications subject to change without notice The Emerson logo is a
2. trademark and a service mark of Emerson Electric Co Germicidal UV Light UV Series Lamp Replacement Annually Replacement Parts PartNo It is recommended to replace lamps annually even if they appear to UV C Lamp UVP 06207 be operating normally because UV C energy production diminishes Electronic Ballast UVP100 UVP 06212 over time Electronic Ballast UVP200 UVP 06213 Lamp Disposal Power Cord 120V UVP 212261 00 Spent UV lamps can be disposed of at local recycling centers or can Power Cord 240V UVP 212107 00 be sent back to White Rodgers using the same containers that the Power Cord Receptacle UVP 212106 00 replacement lamps came in Send to the following address Cover Interlock Switch UVP 212108 00 hie Redigees ainp Recreation Lighted On Off Switch UVP 750 0026 001 1112 Industrial Park Drive Fuseholder UVP 212225 00 Royse City TX 75189 Fuse UVP 750 0108 001 Lamp Placement im Lamp insertion depth into duct 70 143 32 143 32 Exclusive Tilt Bracket Design e Allows customer to place bulbs up in tight spaces 110 e Allows the bulb to be placed down over the coil to get a better angle over the coil e Inreturn air applications tilting one bulb up and the other down enables more of the air stream to be covered Installation UV lights are installed within the HVAC system Select a mounting location that will allow enough clearance for the lamp to be installed and replaced easil
3. White y Rodgers Germicidal UV Light UV Series Stop Summer Colds Before They Start In some homes comfort comes with side effects especially during warmer times of the year Many people find that when they use their air conditioning systems allergies headaches and cold symptoms seem to worsen Unfortunately air conditioning coils are dark and damp offering the perfect environment for the growth of harmful bacteria fungi and molds So in establishing a comfortable temperature homeowners can unwittingly create unhealthy air The White Rodgers UV Light is a remarkably effective means of arresting this bacterial growth The unit emits a germicidal ultraviolet frequency that penetrates the cell walls of detrimental microbes permanently neutralizing any ill effects And better health isn t the sole benefit When mold or similar microbes have been reduced air conditioner efficiency often improves saving the homeowner on operating costs Our multi purpose UV lights have been designed to give you complete market coverage with only two models single lamp and dual lamp lowering your inventory costs Each unit features a universal electronic power supply making it compatible with 120 240 volt applications And our exclusive tilt bracket design allows each unit to adapt to specific application needs by angling the bulb placement when needed Plus both units also use the same UV C lamps Features e High Output Long Life UV C Lamps e
4. y The light may be mounted vertically or horizontally within the HVAC system For 240V electrical outlets an optional power cord must be purchased Any modification to the supplied power cord will void UL safety listing and White Rodgers warranty Installation Package Listings e Germicidal ultraviolet light system e Sheet metal screws FIFRA File 73316 Federal Insecticide Fungicide Rodenticide Act e UV lamp s e Installation amp operation manual UL Safety Agency File E213952 e Power cord e UV warning label for duct White y St Louis Missouri Markham Ontario 314 553 3600 905 201 4701 RO d g gt rs www white rodgers com The Emerson logo is a trademark and E M E RSO N E E Climate Technologies WR 9135 1
Download Pdf Manuals
Related Search
Related Contents
HP Z 420 Betriebsanleitung Operating Instructions L`autodiagnostic stratégique 取扱説明書 - 山田照明 Update on the Asia/Pacific Interim AMHS Database and AMS EDUCATION SANS FRONTIERES General Guidelines & Precautions Important American Standard SYMPHONY 4501 User's Manual 取扱説明書 - 瀧住電機工業株式会社 Copyright © All rights reserved.
Failed to retrieve file