White Rodgers 30A46-105 Installation Instructions

image

Contents

1. as taken by thermocouples attached to the surface of the automatic pilot and pilot burner at the points shown below must not exceed the following Tip of pilot burner 1200 F Tip of thermal element 1400 F Orifice fitting 475 F Capilllary 500 F Terminal pins on switch 175 SPDT Timing Normally open contacts close approximately 60 sec onds after the pilot is ignited Contacts open approximately 40 seconds after the flame is extinguished Switch Action Terminal Designations 2 Normally open 3 Normally closed 1 amp 4 Common 2 The automatic pilot must be mounted near enough to the main gas burner so it is easily ignited by the pilot ignition flame even when the pilot flame is reduced to the point where it is just sufficient to keep the pilot switch contacts closed 3 Proper functioning of the automatic pilot requires that the flame from the main gas burner not touch any part of the automatic pilot 4 The pilot burner must be positioned so as to receive incoming secondary air and not the products of combus tion 5 Unless protected from strong drafts of secondary air which tend to carry the flame away from the bulb the automatic pilot may not be supplied with sufficient heat for proper operation 6 It is recommended that on installations burning manufac tured gas an approved filter of sufficient capacity be connected into the pilot gas line to prevent formation of gu
2. automatiquement lorsque la flamme est rallum e ou lorsque la pression de gaz est revenue la normale DESCRIPTION Si vous n tes pas certain de la tension du c blage de votre syst me soit en millivolts basse tension ou la tension du r seau faites inspecter celui ci par un lectricien un entre preneur agr en chauffage et climatisation ou une personne qui a des connaissances de base en lectricit et en c blage Ne d passez pas les charges nominales Tout le c blage doit tre conforme aux codes et r glements locaux et nationaux qui r gissent les installations lectriques Cette commande est un instrument de pr cision qui doit tre manipul avec soin Elle peut se d traquer si elle est manipul e de fa on n gligente ou si des composantes sont d form es ADVERTISSEMENT N installez pas cet appareil sur des circuits qui d passent la tension nominale Une tension trop lev e peut endommager la commande et poser des risques de chocs lectriques et d incendie Afin de pr venir les chocs lectriques et les dommages mat riels coupez l alimentation du syst me au panneau de distribution lectrique principal pendant toute la dur e de l installation Coupez pendant toute la dur e de l installation le gaz qui alimente le syst me de chauffage Lorsque vous r visez une commande tiquetez tous les fils avant de les d brancher Les erreurs de c blage peu
3. handled carefully Rough handling or distorting components could cause the control to malfunction To prevent electrical shock and or equipment damage disconnect electric power to system at main fuse or circuit breaker box until installation is complete DESCRIPTION PRECAUTIONS CAUTION Shut off main gas to heating system until installation is complete Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dan gerous operation Following installation or replacement follow appliance manufacturer s recommended installation and or ser vice instructions to insure proper operation ATTENTION This product contains mercury There will not be any exposure to mercury under normal conditions of use This product may replace a unit which contains mercury Do not open mercury cells If a cell becomes damaged do not touch any spilled mercury Wearing non absorbent gloves take up the spilled mercury with sand or other absorbent material and place into a container which can be sealed If a cell becomes damaged the unit should be discarded Mercury must not be discarded in household trash When this unit or the unit it is replacing is to be discarded place in a suitable container and return to us En WHITE RODGERS DIVISION EMERSON ELECTRIC CO 9797 REAVIS RD ST LOUIS MO 63123 314 577 1300 Fax 314 577 1517 9999 HWY 48 MARKHAM ONT L3P 3J3 EMIERSON 905 47
4. 5 4653 FAX 905 475 4625 PART NO 37 5551B Printed in U S A Replaces 37 5551A 9623 SPECIFICATIONS These Pilots can be used with either A B or E series pilot burners Pilot Burners are available in 14 port arrangements Bunsen and Non linting and with a wide choice of mounting facilities Orifice fittings offer three different styles of connections each available for the most used gases INSTALLATION To avoid personal injury and or property damage shut off gas and electric to heating system until installation is complete Uncoil the capillary carefully making certain that it is not bent sharply at any place Be particularly careful with that part of the capillary connected to the diaphragm The thermal element of the automatic pilot may be attached to the pilot burner either before or after the pilot burner is mounted to the main burner To attach the thermal element to the pilot burner remove nut and lockwasher slip thermal element into bracket of pilot burner so that screw on element extends through the hole in bracket Then fasten with nut and lockwasher The orifice fitting should then be screwed into the pilot burner and the tubing connected to the orifice fitting The proper location of an automatic pilot with respect to the main burner should be determined by the manufacturer of the burner according to the requirements of the AGA CGA and the local gas utility 1 The operating temperatures
5. WHITE RODGERS 30A46 PLUG IN AUTOMATIC PILOT INSTALLATION INSTRUCTIONS Operator Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND OR PROPERTY DAMAGE These automatic pilots are designed for use with the White Rodgers gas valves having plug in receptacle The pilots are simply plugged in with no additional electrical connections or mounting devices required When used with these valves they prevent the flow of gas to the main burner if the pilot flame is not burning or is insufficient to properly ignite the main burner These plug in pilots may be used with natural manufactured or mixed gases and with L P gases where means are provided for obtaining a 100 shutoff system The pilot burner should be equipped with the recommended size orifice fitting These pilots are automatic reset automatic recycling needing merely relighting or possibly only the resumption of proper gas pressure to put back in operation If in doubt about whether your wiring is millivolt line or low voltage have it inspected by a qualified heating and air condi tioning contractor electrician or someone familiar with basic electricity and wiring Do not exceed the specification ratings All wiring must conform to local and national electrical codes and ordinances This control is a precision instrument and should be
6. euse automatique et du br leur de veilleuse aux endroits indiqu s en l illustration ne doivent pas d passer les valeurs suivantes Au bout du br leur de veilleuse 1200 F Au bout du capteur thermique 1400 F Sur le raccord d entr e 475 F Sur le capillaire 500 F Broches du commutateur 80 C 175 F Commutateur Unipolaire bidirectionnel SPDT D lais Les contacts sont ferm s environ 60 secondes apr s l allumage dela veilleuse Les contacts sont ouverts environ 40 secondes apr s que la flamme se soit teinte Identification des bornes 2 Normalement ouverte 3 Normalement ferm e 1 amp 4 Neutres 2 La veilleuse automatique doit tre install e assez pr s du br leur gaz principal pour assurer que celui ci soit allum par la flamme de la veilleuse m me lorsque cette flamme a t r duite au point o elle suffit tout juste maintenir ferm s les contacts du commutateur de veilleuse 3 Pourquelaveilleuse automatique fonctionne correctement la flamme du br leur principal ne doit en toucher aucune composante 4 Le br leur de veilleuse doit tre orient de fa on br ler de lair secondaire et non des produits de combustion 5 Si elle n est pas prot g e des puissants courants d air secondaire qui ont tendance loigner la flamme de la cuvette la veilleuse automatique risque de ne pas tre chauff e suffisamment pour fonctionner ad quate
7. he thermostat the circuit is completed to the gas valve TESTING THE PILOT After a wait of about five minutes relight the pilot according to the instructions listed under Lighting the Pilot Within 90 seconds another slight sound will be heard indicating that the gas valve supplying gas to the main burner is energized Open the main gas cock once again WHITE RODGERS 30A46 Veilleuse automatique enfichable INSTRUCTIONS D INSTALLATION Utilisateur conservez ces instructions pour vous y r f rer au besoin SI VOUS NE LISEZ PAS ATTENTIVEMENT CES INSTRUCTIONS AVANT D INSTALLER ET D UTILISER LA COMMANDE VOUS RISQUEZ DE CAUSER DES BLESSURES ET DES DOMMAGES MATERIELS La veilleuse automatique est congue pour fonctionner avec un robinet a gaz White Rodgers dot d un prise convenable Elle peut tout simplement tre branch e sans qu aucun autre raccordement ni montage ne soit n cessaire Utilis e avec ce type de robinet la veilleuse coupe le d bit de gaz au br leur principal si la flamme est teinte ou encore si elle ne suffit pas allumer correctement le br leur principal La veilleuse enfichable peut servir avec des syst mes gaz naturel manufactur ou mixte ou encore lorsque la fermeture compl te est assur e avec des syst mes gaz de p trole liquide Veuillez doter le br leur de veilleuse d un raccord d entr e du calibre recommand La veilleuse automatique estremise en marche
8. ltre avec diverses options de montage Les raccords d entr e sont offerts avec trois styles de raccor dement disponibles pour les types de gaz les plus communs INSTALLATION Afin de pr venir les blessures et les dommages mat riels coupez le gaz et l lectricit qui alimentent le syst me de chauffage jusqu a ce que l installation soit termin e c 9 dite c UT a qu il n est pli en aucun endroit Faites particuli rement atten tion lorsque vous manipulez la partie du capillaire qui est raccord e sur la membrane Le capteur thermique de la commande automatique peut tre fix au br leur de veilleuse soit avant soit apr s que la veilleuse ait t install e sur le br leur principal Pour monter le capteur thermique sur le br leur de veilleuse retirez d abord l crou et la rondelle de blocage puis glissez le capteur dans le support du br leur de veilleuse en passant la vis du capteur dans le trou du support Fixez le capteur l aide de l crou et de la rondelle de blocage Vissez ensuite le raccord d entr e dans le br leur de veilleuse puis raccordez le tube au raccord L emplacement id al d une veilleuse automatique par rapport au br leur principal doit tre d termin par le fabricant du br leur conform ment aux exigences de l AGA du CGA et du distributeur de gaz local 1 Les temp ratures d exploitation mesur es par des ther mocouples fix s la surface de la veill
9. m at the orifice 7 Bleed tubes are available for attaching to the bracket of the pilot burner This tube is for burning the bleed gas from the diaphragm gas valve and from the pressure regulator and should be connected accordingly Bleed Burners are available for vertical or horizontal pilots OO Horizontal Vertical The following procedure should be closely followed when light ing the Automatic Pilot 1 2 Set the room thermostat to the lowest setting on the dial Make certain that the main gas supply cock and the pilot gas cock have been closed for at least five minutes to permit the combustion chamber to vent itself Open the pilot gas cock While the main burner is operating close the pilot gas cock and the main gas cock shutting off the gas to both the pilot and the main burner Within 60 seconds a slight sound should be noted which will indicate that the gas valve supplying the main burner is closed The thermostat and limit control contacts must be closed during this test 3 LIGHTING THE PILOT Light the pilot with a match supported on the end of a wire or stick long enough to avoid putting your arm or hand inside the combustion chamber After the pilot flame is burning open the main gas supply cock The main burner ignites when the room thermostat is set to a temperature above that which exists in the room at that particular instant As doing this closes the contacts of t
10. ment 6 Dans le cas d installations qui br lent du gaz manufactur il est recommand de raccorder la conduite de gaz de veilleuse un filtre homologu et de capacit suffisante afin de pr venir la formation de gomme l entr e 7 Des tubes de purge sont disponibles qui peuvent tre mont s sur le support du br leur de veilleuse Ces tubes servent br ler les gaz de purge du robinet de gaz membrane et du r gulateur de pression et ils doivent tre raccord s en cons quence Des br leurs de gaz de purge sont disponibles pour les veilleuses horizontales et verticales OO Horizontal Vertical Pour allumer la veilleuse automatique suivez exactement la d marche suivante 1 2 R glez le thermostat d ambiance au point de consigne le plus bas Assurez vous que le robinet a gaz principal et le robinet a gaz de la veilleuse ont t ferm s depuis au moins cing minutes afin de laisser a rer la chambre de combustion Ouvrez le robinet d alimentation de gaz de la veilleuse Alors que le br leur principal est en marche fermez le robinet de la veilleuse et le robinet principal coupant ainsi le gaz qui alimente la veilleuse et le br leur principal Apr s moins de 60 secondes vous devriez entendre un l ger bruit qui repr sente la fermeture du robinet gaz qui alimente le br leur principal Lors des v rifications les contacts du thermostat et des limiteurs doiven
11. t tre ferm s 6 ALLUMAGE DE LA VEILLEUSE Allumez la veilleuse en vous servant d une allumette fix e au bout d un fil de fer ou d une tige de longueur suffisante pour vous viter d ins rer le bras ou la main dans la chambre de combustion Une fois que la veilleuse est allum e ouvrez le robinet principal d alimentation de gaz Lorsque le point de consigne du thermostat est sup rieur a la temp rature de la pi ce les contacts du thermostat sont ferm s ce qui ferme le circuit du robinet a gaz et allume le br leur principal VERIFICATION DE LA VEILLEUSE Attendez environ cing minutes puis rallumez la veilleuse conform ment aux directives de la section Allumage de la veilleuse Apr s moins de 90 secondes vous devriez encore une fois entendre un l ger bruit qui signifie que le br leur principal a t mis sous tension Ouvrez ensuite le robinet principal
12. vent entra ner un fonctionnement incorrect et dangereux de l quipement Pour assurer un fonctionnement ad quat de l quipe ment apr s l installation ou le remplacement veuillez vous r f rer aux directives d installation ou de r vision du fabricant ATTENTION Cet appareil contient du mercure Il n y a aucun risque d exposition lorsque l appareil est utilis normalement N ouvrez pas les cellules de mercure Si une cellule est endommag e ne touchez pas au mercure qui s en chappe Enfilez des gants tanches et nettoyez le mercure avec du sable ou une autre substance absorbante puis placez le mat riel contamin dans un contenant qui peut tre ferm herm tiquement Si une cellule est endommag e l appareil en entier doit tre jet Ne pas jeter de mercure avec les ordures m nag res Si vous devez jeter cet appareil ou celui qu il remplace placez le dans un contenant convenable et faites le nous parvenir WHITE RODGERS DIVISION EMERSON ELECTRIC CO 9797 REAVIS RD ST LOUIS MO 63123 314 577 1300 T l copieur 314 577 1517 9999 HWY 48 MARKHAM ONT L3P 3J3 905 475 4653 T l copieur 905 475 4625 aN Imprim aux Etats Unis PIECE NO 37 5551B Remplace 37 5551A 9623 SPECIFICATIONS Ces veilleuses peuvent servir avec les br leurs de veilleuse des s ries A Bet E Les br leurs de veilleuse sont disponibles avec 14 disposi tions de buses diff rentes de type Bunsen ou fi