Whirlpool W10443041B-SP User's Manual
Contents
1. NOTE Do not overtighten Damage to the coupling can result 4 Attach long hose to Y connector and tighten couplings 1 G One end of the long hose has a wire mesh strainer inside the coupling Attach this end to the Y connector Attach washer cold inlet hose to other side of Y connector Screw on coupling by hand until it is seated on connector Using pliers tighten the couplings an additional two thirds turn NOTE Do not overtighten Damage to the coupling can result D Attach long hose to dryer fill valve and tighten coupling SN ai Attach other end of long hose to fill valve at bottom of dryer back panel Screw on coupling by hand until it is seated on fill valve connector Using pliers tighten the couplings an additional two thirds turn NOTE Do not overtighten Damage to the coupling can result 17 6 Turn on cold water faucet 2 Move dryer to final location Move dryer to final location Avoid crushing or kinking vent After dryer is in place remove cardboard from under dryer LEVEL DRYER Level Dryer Place level here Check for leaks around Y connector faucets and hoses CONNECT VENT Check levelness of dryer from side to side Repeat from front to back NOTE The dryer must be level for the moisture sensing system to operate correctly Using a 4 102 mm clamp connect vent to exhaust outlet Not Level LEVEL Not
2. ring or spade terminals and UL listed strain relief The 4 wire power supply cord at least 4 ft 1 22 m long must have 4 10 gauge solid copper wires and match a 4 wire receptacle of NEMA Type 14 30 R The ground wire ground 4 wire conductor may be either green or bare The receptacle neutral conductor must be identified by a 14 30R white cover If your outlet looks like this Then choose a 3 wire power supply cord with ring or spade terminals and UL listed strain relief The 3 wire power supply cord at least 4 ft 1 22 m long must have 3 10 gauge solid copper wires and match a 3 wire receptacle of NEMA Type 10 30R 3 wire receptacle 10 30R If connecting by direct wire Power supply cable must match power supply 4 wire or 3 wire and be m Flexible armored cable or nonmetallic sheathed copper cable with ground wire covered with flexible metallic conduit All current carrying wires must be insulated m 10 gauge solid copper wire do not use aluminum at least 5 ft 1 52 m long GROUNDING INSTRUCTIONS E For a grounded cord connected dryer This dryer must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accorda
3. Level in dryer If connecting to existing vent make sure vent is clean Dryer vent must fit over dryer exhaust outlet and inside exhaust hood Check that vent is secured to exhaust hood with a 4 102 mm clamp 18 2 Adjust leveling legs If dryer is not level prop up using a wood block use wrench to adjust legs up or down and check again for levelness Once legs are level make sure all four legs are snug against the ground before adjusting them COMPLETE INSTALLATION CHECKLIST Check that all parts are now installed If there is an extra part go back through steps to see what was skipped L Check that you have all of your tools LL Dispose of recycle all packaging materials LL Be sure the water faucets are on Check for leaks around Y connector faucet and hoses L Check dryer s final location Be sure vent is not crushed or kinked L Check that dryer is level See Level Dryer _ Remove film on console and any tape remaining on dryer _ Wipe dryer drum interior thoroughly with a damp cloth to remove any dust L Read Dryer Use in your Use and Care Guide _ For power supply cord installation plug into a grounded outlet For direct wire installation turn on power _ If you live in a hard water area use of a water softener is recommended to control the buildup of scale through the water system in the dryer Over time the buildup of lime scale may clog different p
4. Supply Cord Connection on page 10 4 WIRE POWER SUPPLY CORD CONNECTION IMPORTANT A 4 wire connection is required for moble homes and where local codes do not permit the use of 3 wire connections 4 wire receptacle NEMA type 14 30R Spade terminals with Ring terminals upturned ends 1 Prepare to connect neutral ground wire and neutral wire Remove center terminal block screw B Remove neutral ground wire E from external ground conductor screw A 2 Connect neutral ground wire and neutral wire Connect neutral ground wire E and neutral wire white or center C of power supply cord under center terminal block screw B Tighten screw 1 Remove center screw KA 3 Connect ground wire Connect ground wire F green or bare of power supply cord to external ground conductor screw A Tighten screw Connect neutral wire white or center C of power supply cord Connect remaining wires to outer terminal block screws to center terminal block screw B Tighten screw Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 3 Connect remaining wires KA 3 WIRE POWER SUPPLY CORD CONNECTION Use where local codes permit connecting cabinet ground conductor to neutral wire 3 wire receptacle NEMA 3 prong plug Connect remaining wires to outer terminal block screws type 10
5. exhaust installations Recommended exhaust installations YN W ARNING Typical installations vent the dryer from the rear of the dryer Other installations are possible Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructions can result in death or fire Alternate installations for close clearances Venting systems come in many varieties Select the type best If you prefer dryer may be converted to exhaust out right side for your installation Two close clearance installations are shown left side all models except WED9051Y or through bottom Refer to the manufacturer s instructions You must contact your local dealer to have dryer converted Use 4 Way Exhaust Kit Part Number W10470674 NOTE On Model WED9051Y only do not exhaust out the left side Special provisions for mobile homes Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home Terminate exhaust vent outside S A E A gt SEZ JEEZ a 2 gt a een ee A SAE lle gt ele HW HD Al HAF J A7 IYS SWN Bottom Exhaust installation AA ACCC g WY AN Periscope installation 15 Determine vent path NW Select route that will provide straightest and most direct path outdoors m Plan installation to use
6. fewest number of elbows and turns m When using elbows or making turns allow as much room as possible m Bend vent gradually to avoid kinking m Use as few 90 turns as possible Determine vent length and elbows needed for best drying performance m Use the following Vent System Charts to determine type of vent material and hood combinations acceptable to use NOTE Do not use vent runs longer than those specified in Vent System Charts Exhaust systems longer than those specified will m Shorten life of dryer m Reduce performance resulting in longer drying times and increased energy usage The Vent System Charts provide venting requirements that will help achieve best drying performance Standard Vent System Chart Number of Box louvered 90 elbows of vent hoods 54 ft 16 5 m 48 ft 14 6 m 2 Rig metat 44 ft 13 4 m 38 ft 11 6 m ES E 58 ft 17 7 m Rigid metal 35 ft 10 7 m 29 ft 8 8 m Rigid metal 27 ft 8 2 m 21 ft 6 4 m Long Vent System Chart Number of Angled 90 elbows of vent hoods hoods ES KA Rigid metal 106 ft 32 3 m 100 ft 30 5 m Rigid metal 98 ft 29 9 m 92 ft 28 0 m For Model WED9051Y only NOTE Bottom exhaust installations have a 90 turn inside the dryer To determine maximum exhaust length add one 90 turn to the chart 16 INSTALL VENT SYSTEM 1 Install exhaust hood Install exhaust hood and u
7. 30R Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements Spade terminals with Ring terminals upturned ends 10 DIRECT WIRE CONNECTION 4 WIRE DIRECT WIRE CONNECTION Direct wire strain relief IMPORTANT A 4 wire connection is required for mobile homes 1 Attach direct wire strain relief and where local codes do not permit 3 wire connections 1 Prepare your 4 wire cable for direct connection Unscrew the removable conduit connector A and any screws from a 3 4 19 mm UL listed strain relief UL marking Direct wire cable must have 5 ft 1 52 m of extra length so on strain relief Put the threaded section of the strain relief dryer may be moved if needed C through the hole below the terminal block opening B Reaching inside the terminal block opening screw the Strip 5 127 mm of outer covering from end of cable removable conduit connector A onto the strain relief threads leaving bare ground wire at 5 127 mm Cut 11 2 38 mm from remaining 3 wires Strip insulation back 1 25 mm Shape ends of wires into hooks 2 Attach direct wire cable to strain relief 2 Attach hooked wires to terminal block To connect wires to terminal block place hooked end of wire under terminal block screw facing to the right squeeze pm hooked end together and tighten screw Put direct wire cable t
8. Electric Dryer Installation Instructions Table of Contents DRYER SAFETY svcsisssssiccnssessttensssenasccsnstaduscanteccanensatsncssssesstaosenanss 2 INSTALLATION REQUIREMENTS ccssccesseccnsecensecenseonses 3 TOONS and Fe ANUS naaa 3 Location Requirements c ccssceesscessnseensecessenseenseenseensenes 4 Electrical Requirements cccsscesseessenseenseeesensseessenseeneeees 6 Install Leveling LeQS ooccconccccncconcononccconnconancnnanrnnannnnannnananmannns 7 Electrical Connection cessecessecensecnssecnseennseeennseenseeensens 8 Venting Requirements ccccsccesseseseeeseeeeseeesseeeaseeeasennseeeaes 14 Plan Vent SST Miranda 15 Install Vent System iii 16 Connect Inlet HOSES 00cooonccccnconnncconncnonncnnnaconnrnnanrnnanrnannnnnanes 17 COMMEGCE i i A incaico or E 18 Level APA 18 COMPLETE INSTALLATION CHECKLIST ccesecesseceees 19 DOOR REVERSAL c ssccnseecnsecensecessecesseeenseonsseensseensenenseees 19 STACKING WASHER AND DRYER ccsseceesecenseceseeeenees 19 TROUBLESHOOTING cccessecensecensecessecnseeenseceasesensesensesenees 19 INSTALLATION NOTES Date of purchase Date of installation Installer Model number Serial number Para obtener acceso al manual de uso y cuidado en espanol o para obtener informacion adicional acerca de su producto visite www whirlpool com Tenga listo su n mero de modelo completo Puede encontrar el n mero
9. Flexible metal vent Acceptable only if accessible to clean E Must be fully extended and supported in final dryer location m Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance m Do not install in enclosed walls ceilings or floors m The total length should not exceed 73 4 ft 2 4 m NOTE If using an existing vent system clean lint from entire length of the system and make sure exhaust hood is not plugged with lint Replace plastic or metal foil vents with rigid metal or flexible metal vents Review Vent System Charts and if necessary modify existing vent system to achieve best drying performance 14 Exhaust hoods E Must be at least 12 305 mm from ground or any object that may obstruct exhaust such as flowers rocks bushes or snow Recommended Styles al mM Louvered Hood Box Hood Acceptable Style Angled Hood Elbows m 45 elbows provide better airflow than 90 elbows Recommended Styles Clamps m Use clamps to seal all joints m Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint Do not use duct tape Improper venting can cause moisture and lint to collect indoors which may result in E Moisture damage to woodwork furniture paint wallpaper carpets etc E Housecleaning problems and health problems PLAN VENT SYSTEM Optional
10. Prepare your 3 wire cable for direct connection Direct wire cable must have 5 ft 1 52 m of extra length so dryer may be moved if needed Strip 3 2 89 mm of outer covering from end of cable Strip insulation back 1 25 mm If using 3 wire cable with ground wire cut bare wire even with outer covering Shape wire ends into hooks 2 Attach hooked wires to terminal block To connect wires to terminal block place hooked end of wire under terminal block screw facing to the right squeeze hooked end together and tighten screw 3 Remove center screw Remove center terminal block screw B 4 Connect neutral wire ESA DON cr GQ AN Place hooked end of neutral wire white or center C of direct wire cable under center terminal block screw B Squeeze hooked end together Tighten screw T NA Place hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together and tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements OPTIONAL EXTERNAL GROUND FOR 3 WIRE CONNECTION You must verify with a qualified electrician that this grounding method is acceptable before connecting 1 Prepare to connect neutral ground wire and neutral wire Remove center terminal block screw B Remove neutral ground wire E from e
11. Q Level Caulking gun and compound for installing new exhaust vent LOCATION REQUIREMENTS AWARNING Explosion Hazard Keep flammable materials and vapors such as gasoline away from dryer Place dryer at least 18 inches 460 mm above the floor for a garage installation Failure to do so can result in death explosion or fire You will need m A location allowing for proper exhaust installation See Venting Requirements m Aseparate 30 amp circuit m If using power supply cord a grounded electrical outlet located within 2 ft 610 mm of either side of dryer See Electrical Requirements m Floor must support dryer weight of 200 Ibs 90 7 kg Also consider weight of companion appliance m Cold water faucets located within 4 ft 1 2 m of the water fill valves and water pressure of 20 100 psi 137 9 689 6 kPa You may use the water supply for your washer using the Y connector and short hose if needed which are provided m 20 100 psi 138 690 kPa for best performance NW Level floor with maximum slope of 1 25 mm under entire dryer If slope is greater than 1 25 mm install Extended Dryer Feet Kit Part Number 279810 If not level clothes may not tumble properly and automatic sensor cycles may not operate correctly For each arrangement consider allowing more space for ease of installation and servicing spacing for companion appliances and clearances for walls doors and floor m
12. and to connect the exhaust vent ELECTRICAL CONNECTION Power Supply Cord A WARNING Fire Hazard Use a new UL listed 30 amp power supply cord Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock Electrical Connection Options 1 Choose electrical connection type Power supply cord 4 wire receptacle NEMA Type 14 30R Go to Power Supply Cord Connection Power supply cord 3 wire receptacle NEMA Type 10 30R Go to Power Supply Cord Connection 4 wire direct connection Go to Direct Wire Connection 3 wire direct connection Go to Direct Wire Connection NOTE If local codes do not permit connection of a cabinet ground conductor to neutral wire go to Optional External Ground for 3 wire connection This connection may be used with either a power supply cord or a direct wire connection Direct Wire A WARNING Fire Hazard Use 10 gauge copper wire Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wir
13. arts of the water system which will reduce product performance Excessive scale buildup may lead to the need for certain part replacement or repair __ Select a Time Dry heated cycle and start dryer Do not select Air Only Temperature setting If dryer will not start check the following e Controls are set in a running or On position e Start button has been pushed firmly e Dryer is plugged into an outlet and or electrical supply e Household fuse is intact and tight or circuit breaker has not tripped e Dryer door is closed This dryer automatically runs an installation diagnostic routine at the start of its first cycle NOTE You may notice an odor when dryer is first heated This odor is common when heating element is first used The odor will go away DOOR REVERSAL If you prefer to reverse the door swing on your dryer A door reversal kit Part Number W10277499 is available to order For further information see Assistance or Service section in your Use and Care Guide STACKING WASHER AND DRYER If you prefer to stack your washer and dryer A stack kit Part Number 8572546 is available to order For further information see Assistance or Service section in your Use and Care Guide TROUBLESHOOTING See your Use and Care Guide for troubleshooting information 19 W10443041B W10443042B SP 2012 02 12 All rights reserved Printed in U S A
14. ast twice as large as dryer exhaust opening ELECTRICAL REQUIREMENTS It is your responsibility To contact a qualified electrical installer To be sure that the electrical connection is adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances The National Electrical Code requires a 4 wire power supply connection for homes built after 1996 dryer circuits involved in remodeling after 1996 and all mobile home installations A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 To supply the required 3 or 4 wire single phase 120 240 volt 60 Hz AC only electrical supply or 3 or 4 wire 120 208 volt electrical supply if specified on the serial rating plate on a separate 30 amp circuit fused on both sides of the line Connect to an individual branch circuit Do not have a fuse in the neutral or grounding circuit Do not use an extension cord If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Electrical Connection To properly install your dryer you must determine the type of electrical connection you will be using and follow the instructions provided for it here This dryer is manufactured ready to install with a 3 wire electrical supply connection The neutral ground conducto
15. de modelo y de serie dentro de la cavidad superior de la puerta W10443041B W10443042B SP DRYER SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean You can be killed or seriously injured if you don t immediately 4 DANGER follow instructions You can be killed or seriously injured if you don t follow A WARN N G instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed A WARNING Risk of Fire Clothes dryer installation must be performed by a qualified installer Install the clothes dryer according to the manufacturer s instructions and local codes Do not install a clothes dryer with flexible plastic venting materials or flexible metal foil type duct If flexible metal duct is installed it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstr
16. e green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock 2 Remove terminal block cover Before you start disconnect power Remove hold down screw and terminal block cover POWER SUPPLY CORD CONNECTION Power supply cord strain relief 1 Attach power supply cord strain relief Remove the screws from a 3 4 19 mm UL listed strain relief UL marking on strain relief Put the tabs of the two clamp sections C into the hole below the terminal block opening B so that one tab is pointing up A and the other is pointing down D and hold in place Tighten strain relief screws just enough to hold the two clamp sections C together 2 Attach power supply cord to strain relief Put power supply cord through the strain relief Be sure that the wire insulation on the power supply cord is inside the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Do not further tighten strain relief screws at this point If your outlet looks like this Power supply cord 4 wire receptacle NEMA Type 14 30R Go to 4 Wire Power Supply Cord Connection on this page If your outlet looks like this Power supply cord 3 wire receptacle NEMA Type 10 30R Go to 3 Wire Power
17. hrough the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Tighten strain relief screw against the direct wire cable 3 Prepare to connect neutral ground wire and neutral wire If your wiring looks like this 4 wire direct connection KC Go to 4 Wire Direct Wire Connection on this page If your wiring looks like this 3 wire direct connection Ke Go to 3 Wire Direct Wire Connection on page 12 Remove center terminal block screw B Remove neutral ground wire E from external ground conductor screw A 11 4 Connect neutral ground wire and neutral wire Connect neutral ground wire E and place hooked end hook facing right of neutral wire white or center wire C of direct wire cable under center screw of terminal block B Squeeze hooked ends together and tighten screw BEA Connect ground wire green or bare F of direct wire cable to external ground conductor screw A Tighten screw Place hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together and tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 12 3 WIRE DIRECT WIRE CONNECTION Use where local codes permit connecting cabinet ground conductor to neutral wire 1
18. nce with all local codes and ordinances E For a permanently connected dryer This dryer must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the dryer WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded Do not modify the plug on the power supply cord if it will not fit the outlet have a proper outlet installed by a qualified electrician SAVE THESE INSTRUCTIONS INSTALL LEVELING LEGS 4 WARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury 1 Prepare dryer for leveling legs To avoid damaging floor use a large flat piece of cardboard from dryer carton place under entire back edge of dryer Firmly grasp dryer body not console panel and gently lay dryer down on cardboard diamond marking Examine leveling legs find diamond marking Screw legs into leg holes by hand use a wrench to finish turning legs until diamond marking is no longer visible Now stand the dryer on its feet Slide the dryer until it is close to its final location Leave enough room for electrical connection
19. oldings Space must be large enough to allow door to fully open Add spacing on all sides of dryer to reduce noise transfer If a closet door or louvered door is installed top and bottom air openings in door are required DRYER DIMENSIONS Front view i lt 4 27 686 mm AY 353 8 899 mm 1 nl 25 mm Side view Left or right side exhaust 174 mm Door open view z ___ _ 48 1 5 Bo re 238 mm 47118 1197 _ oS Back view 281 3 715 mm 31 2 89 mm 14 358 mm NOTE Most installations require a minimum of 5 127 mm clearance behind dryer for exhaust vent with elbow See Venting Requirements IMPORTANT Do not operate install or store dryer where it will be exposed to water weather or at temperatures below 45 F 7 C Lower temperatures may cause dryer not to shut off at end of automatic sensor cycles resulting in longer drying times Spacing for recessed area or closet installation All dimensions show recommended spacing allowed with tested spacing of 0 0 mm clearance on sides and rear m Additional spacing should be considered for ease of installation and servicing m Additional clearances might be required for wall door and floor moldings m Additional spacing should be considered on all sides of the dryer to reduce noise transfer E For closet installation with a door minimum ventilation Openings in the top and bot
20. r is permanently connected to the neutral conductor white wire within the dryer If the dryer is installed with a 4 wire electrical supply connection the neutral ground conductor must be removed from the external ground connector green screw and secured under the neutral terminal center or white wire of the terminal block When the neutral ground conductor is secured under the neutral terminal center or white wire of the terminal block the dryer cabinet is isolated from the neutral conductor If local codes do not permit the connection of a neutral ground wire to the neutral wire see Optional 3 wire connection section A 4 wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited Grounding through the neutral is prohibited for 1 new branch circuit installations 2 mobile homes 3 recreational vehicles and 4 areas where local codes prohibit grounding through the neutral conductors If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should contain A UL listed 30 amp power supply cord rated 120 240 volt minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends If your outlet looks like this Then choose a 4 wire power supply cord with
21. se caulking compound to seal exterior wall opening around exhaust hood Vent must fit over the exhaust hood Secure vent to exhaust hood with 4 102 mm clamp Run vent to dryer location using straightest path possible Avoid 90 turns Use clamps to seal all joints Do not use duct tape screws or other fastening devices that extend into interior of vent to secure vent because they can catch lint CONNECT INLET HOSES For non steam models skip to Connect Vent on page 18 The dryer must be connected to the cold water faucet using the new inlet hoses Do not use old hoses 1 Turn cold water off remove and replace rubber washer Turn cold water faucet off and remove washer inlet hose Check and see if rubber washer is in the Y connector Remove old rubber washer from inlet hose and replace with new rubber washer provided 2 Attach short hose and Y connector If space permits attach the brass female end of the Y connector to the cold water faucet See figure A If Y connector cannot be attached directly to the cold water faucet the short hose must be used See figure B Attach short hose to cold water faucet Screw on coupling by hand until it is seated on faucet Then attach Y connector to brass male end of the short hose Screw on coupling by hand until it is seated on connector 3 Tighten couplings Using pliers tighten the couplings with additional two thirds turn
22. tom of the door are required Louvered doors with equivalent ventilation openings are acceptable E Companion appliance spacing should also be considered m No fuel burning appliance may be installed in the same closet as the dryer Closet installation dryer only Pi 76 mm 864 mm 48 in 310 cm 18 min Co 24 in 155 cm a 76 mm er Sr 4 25 mm K 25 mm Cabinet installation dryer only 18 460 mm 4 f 102 mm YA S 25 mm Closet Installation stacked washer and dryer e 152 mi Y 3 76 mm 48 in 71 310 cm 1803 mm 25 mm A 39 min 990 mm NOTE Some models not recommended for undercounter installation Mobile home Additional installation requirements This dryer is suitable for mobile home installations The installation must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile home construction and Safety Title 24 HUD Part 280 or Standard CAN CSA Z240 MH Mobile home installations require Metal exhaust system hardware available for purchase from your dealer For further information see Assistance or Service section in your Use and Care Guide Special provisions must be made in mobile homes to introduce outside air into dryer Openings Such as a nearby window should be at le
23. uct clothes dryer airflow and increase the risk of fire To reduce the risk of severe injury or death follow all installation instructions Save these instructions IMPORTANT When discarding or storing your old clothes dryer remove the door INSTALLATION REQUIREMENTS TOOLS AND PARTS Gather the required tools and parts before starting installation Tools needed Parts supplied all models Flat blade screwdriver 2 Phillips screwdriver Leveling legs 4 Parts supplied steam models Wire stripper direct wire Tin snips new vent m installations installations lt e AS 1 4 nut driver Vent clamps recommended Long inlet hose Rubber washer Parts package is located in dryer drum Check that all parts A are included NOTE If installing dryer on pedestal do not use leveling legs Adjustable wrench that Utility knife Optional Equipment Not supplied with dryer opens to 1 25 mm or Refer to your Use and Care Guide for information about hex head socket wrench accessories available for your dryer Parts needed Not supplied with dryer Check local codes Check existing electrical supply and venting See Electrical Requirements and Venting Requirements before purchasing parts Check code requirements Some codes limit or do not permit installing dryer in garages closets mobile homes or sleeping quarters Contact your local building inspector Tape measure O
24. xternal ground conductor screw A 2 Connect neutral ground wire and neutral wire Connect neutral ground wire E and neutral wire white or center wire C of power supply cord or cable under center terminal block screw B Tighten screw Place hooked ends of remaining wires under outer terminal block screws hooks facing right Tighten screws Connect a separate copper ground wire G from the external ground conductor screw A to an adequate ground Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 13 VENTING VENTING REQUIREMENTS A WARNING Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructions can result in death or fire WARNING To reduce the risk of fire this dryer MUST BE EXHAUSTED OUTDOORS IMPORTANT Observe all governing codes and ordinances Dryer exhaust must not be connected into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building Only rigid or flexible metal vent shall be used for exhausting 4 102 mm AN 4 102 mm heavy metal exhaust vent m Only a 4 102 mm heavy metal exhaust vent and clamps may be used m Do not use plastic or metal foil vent Rigid metal vent m Recommended for best drying performance and to avoid crushing and kinking