1. When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade To reduce the risk of fire electric shock or personal injury this fan must be mounted to an outlet box marked suitable for fan support and use the mounting screws provided with the outlet box Mounting must support at least 35 Ibs WARNING Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box Fan is only to be mounted to an outlet box marked Acceptable for Fan Support WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrige
2. para asegurar la esfera a la varilla vertical Nota Algunas varillas verticales m s largas tienen un agujero previamente perforado para el tornillo Si la varilla vertical m s larga tiene un agujero previamente perforado ajuste el tornillo en el agujero previamente perforado de la varilla vertical m s larga Si la varilla vertical m s larga no tiene un agujero previamente perforado ajuste el tornillo sobre la varilla vertical para asegurar la esfera de la misma PROCEDA AL PASO 8 J ETL ES Panorama WHO8 Carefully lift fan assembly onto mounting bracket E Rotate fan until notch on downrod ball F engages the ridge on the mounting bracket E This will allow for hands free wiring With bracket holding fan assembly make electrical connections using the following step for wiring instructions Make sure that 7 2 all exposed wiring is secured inside wire nuts Z Levante con cuidado el conjunto del ventilador hasta el soporte de montaje E Gire el ventilador hasta que la muesca de la bola de la varilla vertical F calce sobre la saliente del soporte de montaje E De este modo tendr las dos manos libres para hacer el cableado Con la pieza de montaje sujetando el conjunto del ventilador haga las conexiones el ctricas de acuerdo a las siguientes instrucciones de cableado Aseg rese de que todos los cables expuestos est n asegurados dentro de los conectores tipo tuerca para cables Z PULL CHAIN WIRING OPTION
3. EL VENTILADOR EN UNA CAJA DE EMBUTIR ROTULADA ADECUADA PARA VENTILADORES Y UTILICE LOS TORNILLOS DE MONTAJE INCLUIDOS CON LA CAJA DE EMBUTIR LA MAYOR A DE LAS CAJAS DE EMBUTIR UTILIZADAS NORMALMENTE PARA ARTEFACTOS DE ILUMINACI N NO SON ADECUADAS PARA VENTILADORES Y DEBER AN SER REEMPLAZADAS SI TIENE PREGUNTAS CONSULTE A UN ELECTRICISTA CERTIFICADO 1 2 3 Qin 10 11 12 13 14 16 17 12 13 14 16 17 Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer After making the wire connections gently push connections into outlet box with wire nuts pointing up The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious Read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams
4. WALL CONTROL WIRING OPTION wall control switch not included From Fan From House From Fan From House White common 3 connect White common White common 3 connect White common Well Control Black hot mm connect 28888 Black hot Black hot mm connect gt I Fan Switch hot Blue hot mi Blue hot com connect m Light Switch hot Main ground kxxx3 connect gt Green ground Main ground Ex connect E232 Green ground Attach blue wire only if attaching light kit with fan Attach blue wire only if attaching light kit with fan Follow diagram above to make wiring Follow diagram above to make wiring connections for wall control connections for fan pull chain control operation NOTE A professional electrician is recommended for this type of installation OPCION DE CABLEADO PARA CADENILLA DE TIRO OPCION DE CABLEADO PARA CONTROL DE PARED no est incluido el interruptor de pared 13 Del Ventilador De La Casa Del Ventilador De La Casa Blanco com n E conectar Blanco com n Blanco com n 3 conectar C Blanco com n Control de pared Negro vivo mms conector gt Negro vivo Negro vivo mums conectar Interruptor del ventilador vivo Azul vivo mm Azul vivo tam conectar s tnmi Interruptor de la luz vivo i Principal tierra 53 coneciar s EXX2I Verde de tierra Principal tierra zzzz conectar gt Exz Verde
5. blade holder to the motor are tight Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period If fan wobbles Check that all blades are screwed firmly into blade holders Check that all blade holders are tightened securely to motor Make sure that canopy and mounting bracket are tightened securely to ceiling joist If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation If light does not work 1 Check to see that the wire connections in the switch housing are connected 2 Check for faulty light bulbs 3 If light kit will still not operate contact a qualified electrician for assistance 14 ETL ES Panorama WHO8 Operacion Encienda el ventilador y verifique su funcionamiento La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera 1 jal n r pida 2 jalones mediana 3 jalones lenta 4 jalones apagado Las velocidades para clima c lido o fr o dependen de factores como el tama o de la habitaci n la altura del ventilador el n mero de ventiladores etc A El conmutador de tipo deslizante controla la direcci n hacia adelante o hacia atr s tH NI Clima c lido Adelante El ventilador gira en sentid
6. de tierra CTI TT Conecte el cable azul s lo si conecta un juego de luces al ventilador Conecte el cable azul s lo si conecta un juego de luces al ventilador Siga las instrucciones del diagrama anterior Siga las instrucciones del diagrama anterior para hacer las conexiones para hacer las conexiones de cableado para el de cableado para el ventilador con control de pared NOTA Se ventilador controlado con cadenilla de tiro recomienda que use los servicios de un electricista profesional para este tipo de instalaci n The canopy H has two mating slots and two mating holes Position both slots on canopy directly under and in line with two screws U in the mounting bracket E Lift the canopy allowing the two screws to slide into the mating slots Rotate the canopy until both screws from the mounting bracket drop into the slot recesses Tighten screws securely Install two screws U into the mating holes of the canopy and tighten to secure the canopy to the mounting bracket 1 4 EI dosel H tiene dos ranuras coincidentes y dos orificios coincidentes Coloque ambas ranuras del dosel directamente abajo y en l nea con los dos tornillos U del soporte de montaje E Eleve el dosel permitiendo que los dos tornillos se deslicen dentro de las ranuras Gire el dosel hasta que ambos tornillos del soporte de montaje caigandentro de las ranuras Apriete los tornillos asegur ndolos Instale los dos tornillos U en los orificios coincidentes del
7. dosel y aj stelos para asegurar el dosel al soporte de montaje ETL ES Panorama WH08 9 15 16 17 Attach blade brackets C to blades D using the blade bracket screws V Fije los soportes para paletas C a las paletas D con los tornillos V Check the motor for plastic shipping stabilizer tabs and remove them if they are present Remove the motor screws W from the motor and save for later use Attach the blade assembly to the motor using the motor screws W provided Revise el motor buscando las lenguetas pl sticas estabilizadoras que se colocan para el embalaje y ret relas si las hay Retire los tornillos del motor W y gu rdelos para usarlos posteriormente Fije el conjunto de las aspas al motor usando los tornillos del motor W que se incluyen Remove one of the screws Y on the switch housing plate B and loosen do not remove the other two Retire uno de los tornillos Y de la placa de la estructura del interruptor B y afloje sin retirarlos los otros dos ETL ES Panorama WHO8 Insert the wires from the motor A through the hole in the switch housing J and connect the wires in switch housing to the wires from motor 7 8 using the 9 pin molex plug Inserte los alambres del motor A a trav s del orificio en la estructura del interruptor J y conecte los alambres en el interruptor con los alambres del motor usando el enchufe molex de 9 espigas Attach the switch housi
8. 72559 Panorama by Westinghouse Table of Contents ndice SAEY INONT ON terra kein pie A JI 2 imrormaciomae SCO 1d 06 MOOD s tay o COI MA 2 i f 0 fa qa E E E E O PEA 2 Po o E T A ES N e O EE O EAS 2 i A MTA 3 Bo 918 o E OPORTO 3 Pa Re e E a E sce cee ccee cee cee eee catateceee aes ecesectaeh ieee eect teenies 4 ista de piezas con lecas ae COG toca 4 ars cass E A 6 a A PP A rete ieee een 6 A A o IA 14 05 21 6 al 6 y TA GA 15 BVI INN NPAT E EEA A A EO oi o do 14 MO te ET Ott E A Terr rn reer aaan aio errr errr aa 15 Toue NOO rra 14 OTTO de PrODIEMIOS sereine reiner N EE ata var EEEE A 15 Please write model number Net Weight 20 57 LBS 41 NOW ku here for future reference Peso Neto 9 33 KGS ES S UY Por favor incluya el n mero del modelo aqu para futura referencia ETL ES Panorama WH08 SAFETY TIPS CONSEJOS DE SEGURIDAD OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS HAGA LO SIGUIENTE LEA Y GUARDE ESTAS INSTRUCCIONES WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT AND USE THE OUTLET SCREWS PROVIDED WITH THE OUTLET BOX MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF f LIGHTING FIXTURES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAV NEED TO BE REPLACED CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA ELECTRICA O LESIONES PERSONALES MONTE
9. A Para reducir el riesgo de incendios o choques el ctricos no use este ventilador con un dispositivo de control de velocidad de estado s lido para ventilador o un control de velocidad variable Si esta unidad se instalar sobre una ba era o una ducha debe estar identificada como adecuada para ese tipo de aplicaci n NUNCA coloque un interruptor donde se pueda alcanzar desde una ba era o una ducha Es posible que la operaci n de esta unidad afecte el flujo de aire de combusti n necesario para la operaci n segura de equipo que quema combustible Siga la directrices de seguridad del fabricante de equipo de calefacci n como las publicadas por la Asociaci n Nacional de Protecci n Contra Incendios National Fire Protection Association NFPA y la Sociedad Americana para Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las autoridades del c digo local Antes de efectuar tareas de servicio o limpieza en la unidad apague la alimentaci n en el panel de servicio y bloquee el medio de desconexi n del servicio para evitar que se encienda accidentalmente Cuando no se puede bloquear el medio de desconexi n del servicio el ctrico fije de manera segura y un dispositivo de advertencia prominente como un r tulo al panel de servicio Antes de realizar la instalaci n es importante comprobar y volver a ajustar todos los tornillos seg n correspo
10. N NORMAL DOWNROD INSTALLATION If installing downrod supplied with fan proceed to step 8 EXTENDED DOWNROD INSTALLATION If installing with longer downrod than supplied with fan proceed to page 8 step 10 OPCI N DE INSTALACI N AL RAS Si elige la opci n de montaje al ras proceda al paso 6 NORMAL Si instala la varilla vertical incluida con el ventilador proceda al paso 8 OPCI N DE NORMAL OPCI N CON OPCI N CON VARILLA VERTICAL M S LARGA Si INSTALACI N VARILLA VERTICAL instala una varilla vertical m s larga que la que se incluye AL RAS M S LARGA con el ventilador proceda a la p gina 8 paso 10 Remove three flush mount screws R from the top of the motor Remove canopy hole cover I by pressing out on the inner edges of the cover ring till it releases from the canopy H Guide motor wires through the base of the canopy H as shown Attach canopy to motor housing using three flush mount screws R included in the hardware bag and three flush mount screws previously removed Tighten screws securely Quite tres tornillos de montaje al ras R de la parte superior del acoplamiento del motor Quite la cubierta del orificio del dosel I presionando hacia fuera sobre los bordes internos del anillo de la cubierta hasta que se separe del dosel H Deslice los cables del motor a trav s de la base del dosel H como se indica Fije el dosel al alojamiento del motor con los tres tornillos de montaje al ras R in
11. Tornillo para madera en la bolsa de herrajes Arandela de metal para tornillos para madera Arandela de presi n para tornillos para madera Accesorio para nivelar paletas Bombilla Questions or problems installing your fan Please contact your local electrician Hay piezas faltantes o da adas Por favor visite www westinghouselighting com support Tiene preguntas o problemas con la instalaci n de su ventilador Por favor comun quese con su electricista local ETL ES Panorama WHO8 The reference list below assigns a letter to each part referenced in the assembiv instructions Use this reference as both a descriptive listing as well as designation of the parts final location La siguiente lista asocia una letra de referencia con cada pieza que se menciona en las instrucciones de montaje Ademds de ser un listado Quantitv K mel oo CW Hb NNN A WW W Cantidad ETL ES Panorama WHO8 INSTALLATION INSTALACION Unpack and inspect fan carefully to be certain all contents are included Quite el envoltorio e inspeccione detenidamente el ventilador para verifi car que todas las piezas est n incluidas Turn off power at fuse box to avoid possible y electrical shock Apague la alimentaci n en la caja de fusibles para evitar la posibilidad de descarga el ctrica Use metal outlet box suitable for fan support must support 35 Ibs Before attachi
12. ador de vara K Afloje los tornillos prisioneros S en el acoplador K Inserte la vara G en el acoplador de vara K Aseg rese de alinear el orificio de la vara G con el orificio del acoplador K Instale el pasador transversal del acoplador P a trav s del acoplador y la vara Inserte el pasador tipo prensa O en el pasador transversal hasta que trabe en su lugar Apriete los tornillos prisioneros S en el acoplador PROCEDA AL PASO 12 Loosen downrod ball F from downrod G by removing set screw T Slide downrod ball F off of downrod and remove pin Q Afloje la esfera de la varilla vertical F de la varilla vertical G quitando el tornillo T Deslice la esfera de la varilla vertical F hasta separarla de la varilla vertical y quite el pasador 0 Re install pin Q into extended downrod and slide downrod ball F up to the top of the downrod Re install set screw U to secure ball to downrod Note Some extended downrods have a pre drilled set screw hole If a pre drilled hole is present in the extended downrod tighten the set screw into the pre drilled hole in the extended downrod If no pre drilled hole exists in the extended downrod tighten the set screw against the downrod to secure the downrod ball PROCEED TO STEP 8 Vuelva a instalar el pasador Q en la varilla vertical m s larga y deslice la esfera de la varilla F hasta el extremo superior de la misma Vuelva a insertar el tornillo de fijaci n T
13. ara Vara Dosel Aro de la cubierta del dosel fijo al dosel Juego de luces estructura del interruptor Acoplador fijo al motor Tapa de la estructura del interruptor Vidrio Cadenilla de tiro y remate en la bolsa de herrajes Pasador tipo prensa fijo al acoplador Pasador transversal fijo al acoplador Pasador transversal en la esfera de la vara Tornillo para instalaci n a ras en el motor y la bolsa de herrajes Quantity 1 1 5 5 1 1 1 1 1 1 1 1 4 2 1 1 1 6 2 Cantidad Part U V W X Y Z AA BB CC DD EE Pieza Un SAS EA DD EE Parts missing or damaged Please visit www westinghouselighting com support Description Set Screw attached to downrod ball Screw attached to mounting bracket Blade Bracket Screw in hardware bag Motor Screw in motor and hardware bag Screw attached to Switch Housing Cap Screw attached to switch housing plate Wire Nut Wood Screw in hardware bag Metal Washer for wood screws Lock Washer for wood screws Blade Balance Kit Bulb Descripci n Tornillo prisionero en el acoplador Tornillo prisionero en la esfera de la vara Tornillo fijo a la abrazadera de montaje Tornillo para la abrazadera de aspa en la bolsa de herrajes Tornillo para el motor en el motor y la bolsa de herrajes Tornillo fijo a la tapa de la estructura del interruptor Tornillo fijo a la placa de la estructura de interruptor Conector de alambres
14. cluidas en la bolsa de torniller a y los tres tornillos de montaje al ras que extrajo previamente Apriete los tornillos asegur ndolos SSS SSS H A KI SI For flush mount option raise fan assembly and place onto hook from mounting bracket E into a closed hole on the canopy H This will allow for hands free wiring PROCEED DIRECTLY TO PAGE 9 STEP 13 FOR WIRING OPTIONS Para la opci n de montaje al ras levante el montaje del ventilador col quelo sobre el gancho de la placa de montaje E y cu lguelo en uno de los agujeros cerrados del dosel H De este modo tendr las dos manos libres para hacer el cableado PARA LAS OPCIONES DE CABLEADO PROCEDA DIRECTAMENTE A LA P GINA 9 PASO 13 ETL ES Panorama WH08 7 11 Place downrod assembly into canopy H Feed motor lead wires through downrod canopy assembly Coloque la vara en el dosel H Pase los alambres del motor a trav s del con junto de vara dosel Remove clamp pin O and cross pin P from downrod coupling K Loosen set screws S in downrod coupling K Insert downrod G into downrod coupling K Make sure to align hole in downrod G with the hole in downrod coupling K Install coupling cross pin P through coupling and downrod Insert clamp pin O into cross pin until it snaps into place Tighten set screws S in coupling PROCEED TO STEP 12 Quite el pasador tipo prensa O desde el pasador transversal P del acopl
15. high quality finishes on one blade Select the one that best complements your decor or change the style with just a flip of the blade NOTE Combo Blade finishes vary depending upon model Las aspas del rotor de doble cara presentan dos superficies con un acabado de alta calidad Invirtiendo las aspas puede Ud producir un efecto decorativo adaptado a su ambiente o crear una decoraci n completamente nueva Observaci n las superficies de las aspas de doble cara son distintas en funci n del modelo ETL ES Panorama WH08 3 PARTS REFERENCE LIST LISTA DE PIEZAS CON LETRAS DE REFERENCIA A TO jed or NXWZOVOZZETATIOQOTMONOW gt Pieza BO woe Sry KF TOOTH on wes NOTE NOTA descriptivo este recurso indica tambi n la ubicacion final de las piezas Description Motor Switch Housing Plate attached to motor Blade Bracket Blade Mounting Bracket attached to canopy Downrod Ball Downrod Canopy Canopy Cover Ring attached to canopy Light Kit Switch Housing Coupling attached to motor Switch Housing Cap Glass Pull Chain amp Fob in hardware bag Clamp Pin attached to coupling Cross Pin attached to coupling Cross Pin in downrod ball Flush Mount Screw in motor and hardware bag Set Screw in coupling Descripci n Motor estructura del interruptor Placa de la estructura de interruptor fijo al motor Abrazadera para aspa Aspa Abrazadera de montaje fija al dosel Esfera de la v
16. l interruptor J Attach the switch housing cap L to the switch housing J Secure tightly with small side screws X Note Insert the fan control pull chain through the side hole of the switch housing cap L Fije la tapa de la estructura del interruptor L nuevamente a la estructura L Aj stela firmemente con los tornillos laterales peque os X Nota Inserte la cadenilla de control del ventilador a trav s del orificio lateral de la tapa de la estructura del interruptor L Install E26 base CFL bulbs EE max 14W bulbs included Instale las bombillas fluorescentes compactas EE de base E26 de un m ximo de 14 vatios se incluyen G ETL ES Panorama WHO8 WARNING Lamps included in this ceiling fan should not be used with any dimming system To reduce the risk of fire electric shock or personal injury do not use dimmers jADVERTENCIA Las lamparas que se incluyen con este ventilador de techo no deben ser usadas con ningun sistema de conmutacion de intensidad Para reducir el riesgo de incendios descargas el ctricas o lesiones personales no utilice conmutadores de intensidad Attach the glass M to the socket cap and twist the glass Secure the glass by tightening the side screw on the socket cup Do not overtighten screws Repeat for each glass 24 Acople el vidrio M al casquillo del portal mpara y gire el vidrio Fije el vidrio apretando el tornillo lateral en la base del po
17. nda ADVERTENCIA Las l mparas que se incluyen con este ventilador de techo no deben ser usadas con ning n sistema de conmutaci n de intensidad Para reducir el riesgo de incendios descargas el ctricas o lesiones personales no utilice conmutadores de intensidad PREPARATION PREPARACI N Before beginning assembly installation or operation of product make sure all parts are present Compare parts with the Parts Reference List Estimated Assembly Time 35 minutes standard installation Tools Required for Assembly Phillips Screwdriver Step Ladder not included Antes de comenzar el montaje la instalaci n o la operaci n de este producto compruebe que contenga todas las piezas requeridas Aseg rese de que las piezas corresponden a la Lista de piezas con letras de referencia Tiempo estimado de montaje 35 minutos instalaci n est ndar Herramientas necesarias para el montaje Destornillador Phillips y escalera de mano no incluidos 2 ETL ES Panorama WH08 FEATURES CARACTER STICAS VAULTED CEILING INSTALLATION FLUSH MOUNT INSTALLATION DOWNROD INSTALLATION INSTALACI N PARA INSTALACI N AL RAS INSTALACI N CON VARILLA VERTICAL CIELORRASOS ABOVEDADOS For low ceilings For normal ceilings May require a longer downrod sold separately Para cielorrasos bajos Para cielorrasos normales Podr a requerir una varilla vertical m s larga se vende por separado COMBO BLADE ASPAS DE DOBLE CARA Combo Blades feature two
18. ng fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Use una caja de embutir de metal adecuada para soportar un ventilador debe soportar 35 libras Antes de fijar el ventilador a la caja de embutir aseg rese de que la misma est fijada de manera segura en por lo menos dos puntos a un miembro estructural del cielo raso una caja suelta har a que el ventilador oscile Remove the screws U from the two mating holes on the canopy H Save these for use in Step 14 Loosen do not remove the screws U in the mating slots on the canopy H Rotate the mounting bracket E and remove 3 from the canopy H Quite los tornillos U de los dos orificios coincidentes del dosel H Gu rdelos para usarlos en el paso 14 Afloje no quite los tornillos U de las ranuras coincidentes del dosel H Gire el soporte de montaje E y sep relo del dosel H Install mounting bracket E to outlet box in ceiling using the screws and washers provided with the outlet box 4 Instale el soporte de montaje E a la caja de embutir del cielorraso con la torniller a suministrada con la caja de embutir 6 ETL ES Panorama WHO8 Choose a mounting option Elija una opcion de montaje l NORMAL FLUSH MOUNT INSTALLATION If flush t opt EXTENDED is selected proceed to step 6 eee cee orn DOWNROD DOWNROD INSTALLATION INSTALLATION INSTALLATIO
19. ng to the switch housing plate B by placing the keyslot holes from the switch housing J onto the two protruding screw heads Y on the switch housing plate Twist the switch housing until the screw J 9 heads engage the keyslots Fije la estructura del interruptor a la placa de la estructura del interruptor B insertando las ranuras de la estructura del interruptor J en las cabezas de los dos tornillos Y que sobresalen de la placa de la estructura Gire la estructura del interruptor hasta que las cabezas penetren en la parte m s estrecha de las ranuras Install screw Y removed from switch housing plate step 17 into the closed hole in the switch housing J Tighten all screws to complete attachment of the switch housing 20 Instale el tornillo Y de la placa de la estructura del interruptor retirado anteriormente paso 17 en el orificio cerrado de la estructura del interruptor J Apriete todos los tornillos para terminar de fijar la estructura del interruptor ETL ES Panorama WH08 21 22 Remove the three side screws X from the switch housing cap L Connect the two single wire plugs from the switch housing cap L to the two single wire plugs from the switch housing J Retire los tres tornillos laterales X de la tapa de la estructura del interruptor L Conecte los dos enchufes de alambre individual de la estructura del interruptor L a los dos enchufes de alambre individual de la tapa de la estructura de
20. ntalmente Cuando no se puede bloquear el medio de desconexi n del servicio el ctrico fije de manera segura y un dispositivo de advertencia prominente como un r tulo al panel de servicio Tenga cuidado Lea todas las instrucciones y la informaci n de seguridad antes de instalar su ventilador nuevo Revise los diagramas de montaje incluidos Al cortar o perforar una pared o el cielo raso no da e el cableado el ctrico y otras instalaciones de servicios p blicos ocultos Aseg rese de que el sitio para la instalaci n que escoja permita que el ventilador gire libremente sin obstrucciones Deje un espacio m nimo de 7 pies desde le piso hasta el borde posterior de la paleta Para reducir el riesgo de incendios choques el ctricos o lesiones personales este ventilador se debe montar sobre una caja de embutir que tenga una marca que indique que es adecuada para soportar un ventilador Adem s debe utilizar los tornillos correspondientes incluidos con la caja de embutir El montaje debe soportar por lo menos 15 87 kgs ADVERTENCIA No doble los soportes para las paletas durante la instalaci n al motor al balancear o durante la limpieza No inserte objetos extra os entre las paletas mientras giran Fije el soporte de montaje usando s lo la torniller a suministrada con la caja de embutir El ventilador s lo se debe montar en una caja de embutir marcada Acceptable for Fan Support Aceptable para soportar ventiladores ADVERTENCI
21. o contrahorario Una corriente de aire descendente crea un efecto refrescante como lo indica la ilustraci n A Esto le permite ajustar el aire acondicionado a una temperatura Y N m s alta sin que afecte su comodidad B Clima fr o Atr s El ventilador gira en sentido de las agujas del reloj Una corriente de aire ascendente aleja el aire caliente del rea del ventilador de techo como lo indica la ilustraci n B Esto le permite ajustar la calefacci n a un g 7 nivel m s bajo sin que afecte su comodidad De todos modos por favor consulte el punto 10 de las Sugerencias de y 7 seguridad cuando utilice el ventilador en esta posicion NOTA Apague el ventilador y espere a que se detenga antes de cambiar la direcci n de adelante atrds con el conmutador de tipo deslizante Mantenimiento 1 El movimiento natural del ventilador podr a hacer que se aflojen algunas conexiones Verifique las conexiones de soporte las piezas de fijaci n y los accesorios de las paletas dos veces al a o Cerci rese de que est n aseguradas 2 Limpie el ventilador peri dicamente para ayudar a mantener su apariencia nueva con el correr de los a os No use agua para limpiarlo ya que podr a da ar el motor o la madera o causar descarga el ctrica 3 Use s lo un cepillo blando o un trapo sin pelusa para no rayar el acabado El enchapado est sellado con una capa de laca para minimizar la decoloraci n o p rdida del brillo 4 No hay necesidad de aceitar el ven
22. o point 10 in Safety Tips when operating g 7 in this position C 7 NOTE Turn off and wait for fan to stop before changing the setting of the forward reverse slide switch Maintenance 1 Because of the fan s natural movement some connections may become loose Check the support connections brackets and blade attachments twice a year Make sure they are secure 2 Clean your fan periodically to help maintain its new appearance over the years Do not use water when cleaning This could damage the motor or the wood or possibly cause electrical shock 3 Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer coating to minimize discoloration or tarnishing 4 There is no need to oil your fan The motor has permanently lubricated bearings Troubleshooting Guide PROBLEM SUGGESTED REMEDY If fan does not start Check main and branch circuit fuses or circuit breakers Check wire connections as performed in step 14 of installation CAUTION Make sure main power is turned off Make sure forward reverse switch is firmly to one side or the other Fan will not operate when switch is in the middle If the fan still will not start contact a qualified electrician Do not attempt to troubleshoot internal electrical connections yourself If fan sounds noisy Check to make sure all screws in motor housing are snug not over tightened Check to make sure the screws which attach the fan
23. ration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel All set screws must be checked and re tightened where necessary before installation WARNING Lamps included in this ceiling fan should not be used with any dimming system To reduce the risk of fire electric shock or personal injury do not use dimmers El trabajo de instalaci n y el cableado el ctrico los deben efectuar personas calificadas cumpliendo con todos los c digos y las normas aplicables ANSI NFPA 70 1999 incluyendo las de incendio Use esta unidad s lo de la manera en que el fabricante quiere que se haga Si tiene dudas llame al fabricante Despu s de hacer las conexiones empuje con cuidado las conexiones dentro de la caja de empalmes con los conectores de cables mirando hacia arriba Se deben separar los cables el conductor de puesta a tierra y el conductor de puesta a tierra del equipo a un lado de la caja de embutir y el conductor que no tiene puesta a tierra del otro lado de la misma Antes de comenzar a instalar el ventilador apague la alimentaci n en el panel de servicio y bloquee el medio de desconexi n del servicio para evitar que se encienda accide
24. rtal mparas No apriete demasiado los tornillos Repita esto para cada vidrio Assemble decorative fob and extension chains N from hardware bag to fan pull chains by inserting end of chain into chain coupling Confirm chains are held by lightly pulling both chains 25 in coupling Sujetar las cadenas largas de tiro N con las piezas finales correspondientes a las cadenas del ventilador introduciendo el extremo de la cadena larga en la pieza de union Asegurese de que las cadenas est n bien sujetas tirando ligeramente de ambas cadenas en la pieza de union ETL ES Panorama WH08 13 Operation Turn on the power and check operation of fan The pull chain controls the fan speeds as follows 1 pull high 2 pulls medium 3 pulls low 4 pulls off Speed settings for warm or cool weather depend on factors such as room size ceiling height number of fans and so on The slide switch controls direction forward or reverse A Warm weather Forward Fan turns counterclockwise direction A downward air flow creates a U W cooling effect as shown in illustration A This allows you to set your air conditioner on a higher temperature setting without affecting your comfort Y N Cool weather Reverse Fan turns clockwise direction An upward airflow moves warm air off the B ceiling area as shown in illustration B This allows you to set your heating unit on a lower setting without affecting your comfort Please however refer t
25. s a los soportes de las paletas Verifique que todos los soportes de las paletas est n firmemente aseguradas al motor Aseg rese de que el dosel y el soporte de montaje est n firmemente asegurados a la viga del cielorraso Sila oscilaci n de la paleta sigue siendo visible es posible que al intercambiar dos paletas adyacentes lado a lado se redistribuya el peso y el funcionamiento sea m s suave Sila luz no funciona Verifique que el conector molex del alojamiento del interruptor est conectado Compruebe si hay l mparas defectuosas Si el conjunto de luces no funciona p ngase en contacto con un electricista calificado ETL ES Panorama WH08 15 Westinghouse Lighting Corporation a Westinghouse Electric Corporation licensee Y is a registered trademark of Westinghouse Electric Corporation Made in China O 2008 Westinghouse Lighting Corporation Westinghouse Lighting Corporation titular de la licencia de Westinghouse Electric Corporation es una marca registrada de Westinghouse Electric Corporation Fabricado en China O 2008 Westinghouse Lighting Corporation ETL ES Panorama WHO8
26. tilador El motor tiene cojinetes de lubricaci n permanente Gu a para solucionar problemas PROBLEMA SOLUCI N SUGERIDA Si el ventilador no Compruebe los fusibles o disyuntores principales y del circuito derivado arranca Compruebe el cableado del bloque de terminales como lo hizo en el paso No 14 de la instalaci n ADVERTENCIA Aseg rese de que la alimentaci n principal est apagada Aseg rese de que el interruptor de tipo deslizante est firmemente situado en una de sus dos posiciones El ventilador no funcionar si el interruptor de tipo deslizante est situado en el medio Si el ventilador no arranca p ngase en contacto con un electricista calificado No intente reparar conexiones el ctricas internas Si el ventilador es rui Compruebe para asegurarse de que todos los tornillos del alojamiento del motor est n ajustados doso no los apriete demasiado Compruebe para asegurarse de que los tornillos que fijan el soporte de la paleta del ventilador al motor est n apretados Algunos motores de ventilador son sensibles a las se ales de los controles de velocidad variable de estado s lido para motores NO USE un control de velocidad variable de estado s lido 4 Permita el rodaje del ventilador durante un per odo de 24 horas La mayor a de los ruidos asociados con el ventilador nuevo desaparecer n despu s de este per odo Si el ventilador oscila Verifique que todas las paletas est n firmemente atornillada