Home

Westinghouse Fallon Two-Light Indoor Semi-Flush Ceiling Fixture 6228700 Instruction Manual

image

Contents

1. colored wire to the grounding conductor of the supply circuit If your fixture is supplied with an SPT Cord connect the half of the SPT Cord that is ribbed surface to the white wire of the supply circuit Connect the smooth half of the wire the half with markings to the black wire of the supply circuit Use UL Listed wire connectors suitable for the size type and number of conductors No loose strands or loose wires should be present Secure wire connectors with ULL listed electrical tape FINAL ASSEMBLY 1 Spread the electrical splices so that the black wires are on one side of the outlet box and the white wires are on the other side 2 Place fixture against mounting surface allowing the threaded nipple or machine screws to pass through the coverplate Secure with mounting nut or acorn nuts For fixtures with channel shape mounting bracket Place the coverplate over the channel and secure with screws provided 3 If applicable place candle cover s over lampholder s before installing bulb s Install the light bulb s not provided CAUTION Refer to the relamping label located near the lampholder for recommended maximum wattage do not exceed recommended wattage 4 lf applicable attach the shade to the fixture some shades require the use of shade attachment screws Do not overtighten these screws too much pressure could cause glass brackage See Fig 3 for placement of fabric spacer not supplied on all models 5 Outdoor wall fixtures mu
2. es prove do en todos los modelos Westi n oh ou S e and Westinghouse are registered trademarks of Westinghouse Electric Corporation 5 Los montajes al aire libre de la pared deben ser rellenado con RTV conveniente o con el compuesto de silic n alrededor de la tapa y de los lados de la tapadera 5 wer Westinghouse sont des marques d pos es de Westinghouse Electric Corporation para reducir la imposici n del agua en el area de empalme Dejar el fondo libre permitiendo una via de escape para la humedad Made in China Fabriqu en Chine 6 Restablecer la electricidad y comprobar la operaci n de su nuevo artefacto de iluminaci n O 2010 WESTINGHOUSE LIGHTING CORP 3 4
3. 4 Before starting the installation disconnect the power by turning off the circuit breaker or by removing the fuse at the fuse box Turning the power off using the light switch is not sufficient to prevent electrical shock NOTE The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and care are factors which cannot be built into any product These factors must be supplied by the person s caring for and operating the fixture UNPACK THE FIXTURE Check the contents of the box You should receive e Mounting hardware package Lampholder assembly s Mounting bracket Shade s not provided on all models Shade attachment screws 3 for each shade not provided on all models PREPARE THE FIXTURE NOTE FIRST TURN OFF ELECTRICITY ADJUST THE CROSS BAR 1 If you are replacing an existing fixture disconnect and remove the old fixture Expose the supply wiring from the outlet box 2 Some fixtures are provided with a threaded nipple see Fig 1 or machine screws see Fig 2 and 2A for attaching the fixture to the mounting bracket If your fixture is supplied with a threaded nipple screw the nipple 3 complete turns into the mounting bracket and lock into place with a hexagon lock nut If your fixture is supplied with machine screws thread the machine screws into the opposite side of the mounting bracket from the gree
4. Westinghouse ea You can be sure did if its Westinghouse WARNING RISK OF FIRE MOST DWELLINGS BUILT BEFORE1985 HAVE SUPPLY WIRE RATED 60 C CONSULT A QUALIFIED ELECTRICIAN BEFORE INSTALLING Seeeesacsasaaassas CEN 7 3 A 2 3 4 3 A Y NAAA NOTE The above diagram illustrates the installa tion of your new lighting fixture This is a representative drawing and is not intended to match the style of your fixture READ amp SAVE THESE INSTRUCTIONS INSTALLATION OPERATION INSTRUCTIONS TOOLS amp MATERIALS REQUIRED Blade screw driver Adjustable wrench Step Ladder Wire cutters Wiring supplies as required by electrical code CAUTION Before assembling your lighting fixture refer to the section titled ELECTRICAL CONNECTIONS If you feel you do not have electrical wiring experience refer to a do it yourself wiring handbook or have your fixture installed by a qualified licensed electrician GENERAL 1 To ensure the success of the installation be sure to read these instructions and review the diagrams thoroughly before beginning 2 All electrical connections must be in accordance with local codes ordinances or the National Code If your are unfamiliar with methods of installing electrical wiring secure the services of a qualified licensed electrician 3 These fixtures are intended to be mounted to a 4 X 2 1 8 deep metal octagon outlet box The box must be directly supported by the building structure
5. etar alambre de tierra verde o cobre pelado desdel circuito de la fuente hasta el soporte de montaje con los tornillos verdes de tierra prove dos para fijaci n Algunos modelos tienen alambre de tierra sujetado al artefacto Para modelos que utilizan alambres de tierra verde o cobre pelado es necesario conectar el alambre de tierra verde or pelado al conductor de tierra del circuito de la fuente Sujetar los conductores de tierra al soporte de montaje con tornillos verdes de tierra de fijaci n 5 Hacer las conexiones el ctricas VEA ABAJO Figura 2 CONEXIONES EL CTRICAS Para hacer conexiones el ctricas Conectar alambre s blancos desde el artefaco con el alambre blanco del circuito de la fuente Conectar alambre s negros desde el artefaco con el alambre negro del circuito de la fuente Conectar el alambre de color verde o cobre pelado al conductor de tierra del ciruito de la fuente Si su artefacto es proporcionado con una cuerda de SPT conectar la mitad de la cuerda del SPT que es de superficie acanalada con el alambre blanco del circuito de la fuente Conectar la mitad lisa del alambre la mitad con las marcas con el alambre negro del circuito de la fuente Utilizar los conectadores enumerados U L de alambre convenientes para el tama o el tipo y el n mero de conductores No debe haber filamentos flojos de conexiones flojas Asegurar los conectadores del alambre con la cinta el ctrica enumerada U L ENSAMBLAJE FINAL 1 Separar
6. los empalmes el ctricos de modo que los alambres negros est n en un lado de la caja del enchufe y los alambres blancos est n en el otro lado 2 Colocar el artefacto contra la superficie de montaje permitiendo las entrerroscas roscadas o los tornillos de maquina pasar a traves de la tapadera Asegurar con tuerca de montaje o tuerca de la bellota Para artefactos con soporte de montaje en la forma de canal colocar la tapadera sobre el canal y asegurar con tornillos Figura 3A NAAA AAA DA NOTE IMPORTANTE el diagrama anterior ilustra la instalacion de su f nuevo artefacto de luz Este es un diagrama general y no es intentado Figura 1 para corresponder el estilo de su artefacto prove dos 3 Si fuera applicable colocar cubierto s de velas sobre portal mpara s antes de instalar bombilla s Instalar bombilla s no es prove do PRECAUCI N Referir a Westinghouse Lighting Corporation Philadelphia PA 19154 1029 U S A la etiqueta para reemplazar bombillas situada cerca de la portal mpara Para el vatiaje recomendado no exceder el vatiaje recomendado Westinghou g Corporation a Westinghouse Electric Corporation licensee 4 Si fuera applicable sujetar las cortinas al artefacto algunas cortinas requiren el uso de tornillos de fijaci n para cortinas No debe apretar estos tornillos www westinghouselighting com demasiado demasiada presi n podr a causar la fractura del cristal Vea figura 3 para colocaci n del espaciador de la tela no
7. n ground screw Lock the machine screws into place with lock nuts EXCEPTION Ceiling mounted fixtures with keyhole slots should have machine screws entering mounting bracket from same side as green grounding screw see Fig 2A 3 Fasten the mounting bracket to the outlet box using the two screws supplied with the outlet box If your fixture is supplied with a channel shape mounting bracket with keyhole slots for attachment to the mounting surface see Fig 3 it will be necessary to mark the location of the keyhole slots on the mounting surface and drill holes for fasteners not provided Use fasteners suitable for the mounting surface The narrow end of the keyhole slot should face up 4 Attach grounding wire green or bare copper from the supply circuit to the mounting bracket with the green grounding attachment screw provided Some models have a grounding wire attached to the fixture for models that employ a green or bare copper grounding wire it will be necessary to connect the green or bare grounding wire to the grounding conductor to the supply circuit Attach all grounding conductors to the mounting bracket with the green grounding attachment screw 5 Make electrical connections SEE BELOW ELECTRICAL CONNECTIONS To make electrical connections Connect the white wire s from the fixture to the white wire of the supply circuit Connect the black wire s from the fixture to the black wire of the supply circuit Connect the green or bare copper
8. on intentados para ser montados a una caja profunda octagonal de enchufe con medidas de 4 x 2 1 8 La caja debe ser soportada directamente por la estructura del edificio 4 Antes de comenzar la instalaci n debe desconectar la electricidad por medio de cortar la corriente de cortacircuitos o remover el fusible en la caja de enchufe Cortando la electricidad por medio del interruptor no es suficiente para prevenir ataque de electricidad Figura 1 Figura 1A CIIN IMPORTANTE Los dispositivos de seguridad y las instrucciones que aparece en este manual no es intentado para cubrir todas las posibles condiciones y situaciones que puedan ocurrir Debe ser comprendido que el sentido comun precaucion y cuidado son factores que no se pueden ser construidos dentro del producto Estos factores deben ser proporcionados por las personas que estan a cargo del producto o personas que utilizan el producto DESEMPACANDO EL ARTEFACTO Verifique el contenido del carton Debe recibir Paquete maquinaria del montaje Ensamblaje de Portal mparas Soporte de Montaje Cortinas no es proporcionado en todos los modelos Tornillos de montaje para las cortinas 3 para cada cortina no es proporcionado en todos los modelos 7 5 A A A Z y A Z 4 PREPARE EL ARTEFACTO IMPORTANTE PRIMERO CORTE LA ELECTRICIDAD Y AJUSTESE LA BARRA TRASVERSAL 1 Si Ud esta reemplazando un artefacto existente desconecte y remueva el artefacto existente Exponga los cable
9. s de la fuente desde la caja de enchufe Figura 2A 2 Algunos artefactos son proporcionados con una entrerrosca roscada vea Figura 1 or tornillos de la m quina vea Figura 2 y 2A para sujetar el artefacto al soporte de montaje Si su artefacto proporciona con una entrerrosca roscada atornille la entrerrosca con 3 vueltas completas dentro del soporte de montaje y trabar en lugar con una tuerca de fijaci n hexagonal Si su artefacto proporciona con tornillos de la m quina roscar los tornillos de la m quina en el lado opuesto del soporte de montaje desde los tornillos verdes de tierra Trabar los tornillos de la m quina en su lugar con tuercas de fijaci n EXCEPCION Artefactos montados en el techo con ranuras del ojo de cerradura debe tener los tornillos de la m quina entrando el soporte de montaje en el mismo lado como los tornillos verdes de tierra vea Figura 2A 3 Sujetar el soporte de montaje a la caja del enchufe usando los dos tornillos prove dos en la caja del enchufe Si su artefacto es proporcionado con un soporte de montaje en la forma de canal con ranuras de ojo de la cerradura para fijaci n en la superficie de montaje vea Figura 3 sera necesario marcar el lugar de las ranuras de ojo de la cerradura en la superficie de montaje y perforar agujeros para los sujetadores No es prove do Usar sujetadores apropiados para la superficie de montaje El extremo estrecho de la ranura del ojo de la cerradura debe ser de cara arriba 4 Suj
10. st be caulked with suitable RTV or Silicone compound around the top and sides of the coverplate to reduce the chance of water intruding into the splicing area Leave the bottom clear to allow moisture a means of escape 6 Restore electricity and check the operation of your new lighting fixture LEA Y GUARDE ESTAS INSTRUCCIONES ADVERTENCIA PELIGRO DE INCENDIO CASI TODAS LAS RESIDENCIAS FABRICADO ANTES DE 1985 INSTRUCCIONES DE INSTALACION V OPERACI N NA E oi LA FUENTE CLASIFICADO 60 C CONSULTAR A UN ELECTRICISTA CAPACITADO HERRAMIENTS Y MATERIALES REQUERIDOS Destornillador reversible Llave inglesa Escalera de mano Cortador de alambres e Cables de la fuente requeridos por c digos de electricidad ADVERTENCIA antes de instalar su artefacto de luz refiera a la secci n titulada CONEXIONES ELECTRICAS Si Ud siente que no tiene experiencia en la conexi n de cables refierase a un manual de conexi n de cables o solicite la instalacion de su artefacto por un electricista capacitado y acreditado GENERAL 1 Para asegurar una instalaci n exitosa asegurese de leer las instrucciones y repase los diagramas completamente antes de comenzar 2 Todas las conexiones electricas deben ser de acuerdo con los c digos locales ordinanzas or El C digo Nacional de Electricidad Si Ud no es familiarizado con los m todos de instalacion de conexiones electricas solicite el servicio de un electricista capacitado y acreditado 3 Estos artefactos s

Download Pdf Manuals

image

Related Search

Related Contents

Samsung Combi Micro-ondes  MU-Thermocouple1 CAN - User Manual  HYDR8 Skin Scanner User Manual  Circular nº 21/2015    Guida all`amministrazione di NDS eDirectory  5 - Computer Dynamics  RP-PB41 - V1 0 - USER MANUAL - EN  WARNING Indicates a hazardous situation  HP LaserJet P4010 and P4510 Series Printers User Guide  

Copyright © All rights reserved.
Failed to retrieve file