Home
Vista 20SE User's Manual
Contents
1. For Acct 1234 enter 112 34 leading 0 in the subscriber account number and do For Acct B234 enter 11 2 3 4 not use digits A F anywhere in the number Some paging systems provide voice mail capability which For Acct 123 enter see en eS i is activated by a leading 0 in the message PHONE SYSTEM SELECT REPORT FORMAT tp If Cent Sta S NOT on a WATS line O Pulse Dial 1 Tone Dial if Cent Sta S on a WATS line 2 Pulse Dial 3 Tone Dial 7 0 Primary Secondary 0 3 1 4 1 ADEMCO L S STANDARD 6 or undefined 4 2 ADEMCO EXPRESS 1 3 1 4 1 RADIONICS STANDARD 7 ADEMCO CONTACT ID REPORTING 2 4 2 ADEMCO L S STANDARD 8 3 1 4 1 ADEMCO L S EXPANDED 3 4 2 RADIONICS STANDARD 9 3 1 4 1 RADIONICS EXPANDED T Entry of a number other than one specified will give unpredictable results 49 SPLIT DUAL REPORTING 0 0 Disable Backup report only TO PRIMARY PHONE No TO SECONDARY PHONE No 1 Alarms Restore Cancel Others 2 All except Open Close Test Open Close Test 3 Alarms Restore Cancel All 4 All except Open Close Test All 5 All All TO PRIMARY PHONE No TO PAGING No Secondary A 10 digit code is sent to the pager consisting 6 All except Open Close Alarms Open Close Troubles of a 4 digit subscriber number a 3 digit event code 7 All reports Alar
2. 0 if using 4285 Voice Module INITIALIZES DOWNLOAD ID SUBSCRIBER ACCOUNT No FOR INITIAL DOWNLOAD No data entry required SETS ALL PROGRAM FIELDS TO DEFAULT VALUES No data entry required Exits programming mode and prevents re entry by Installer Code 8 0 0 If 98 is used to exit programming mode system must be powered down and method 1 above used to enter the programming mode Exits programming mode and allows re entry by Installer Code 8 0 0 or Power up then press and within 50 seconds of power up OUTPUT RELAYS POWERLINE CARRIER DEVICES WORKSHEET FOR 80 and 81 Applicable only if Relays and or Powerline Carrier Devicess are to be used 80 OUTPUT DEVICES This is an interactive menu mode Fill in the required data on the worksheet on below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence Notes 1 For Relays field 25 must be programmed for a 4229 Relays 01 and 02 OR for a 4204 Relays 01 to 04 2 For Powerline Carrier devices field 27 must be programmed with a House Code 3 Tampers of expansion units cannot be used to operate devices START STOP either or both either or both ZONE ZONE TYPE PART N RESTORE of ZONE TYPE PART N DEVICE ACTION EVENT LIST SYST OP N No ZONE LIST SYST OP N No X 10 NUMBER A EV ZL ZT P ZL ZT P SELECT OUTPUT
3. 0 A 1 0 J K __ 00 Partition 1 only 1st digit enter 1 9 2nd digit enter 11 for or 12 for Entering 0 for either digit disables code 0 0 disable enable Trouble code 1 9 B 11 C 12 D 13 E 14 or F 15 The 2nd digit of Trouble Dialer Report is automatically entered from field 60 0 for UL installations Wwe t 0 1 yes 0 no 0 for UL installations T 0 0 timeout 1 no timeout tp 0 none 1 4 min 2 8 min 3 12 min 4 16 min 1 4 min minimum for UL __ 70 70 Part 1f Part 2T 00 99 exit delay time for each partition __ 80 80 Part 1T Part 2T 00 99 entry delay 1 time for each partition 20 seconds max for UL installations T Entry of a number other than one specified will give unpredictable results ae ENTRY DELAY 2 zone type 02 AUDIBLE EXIT WARNING CONFIRMATION OF ARMING DING POWER UP IN PREVIOUS STATE DIALER PROGRAMMING 40 53 In fields 40 41 42 enter up to the number of digits shown Do not fill unused spaces Enter 0 9 11 for 12 for 13 for a pause 40 PABX ACCESS CODE PRIMARY PHONE No SECONDAR
4. CT O ONT w oA Wired Zone 4 CIJ O LLtittl w L Wired Zone 5 C O OIN w Cy Wired Zone 6 C Cl ONN mwv Cy wreazone7 OAO CL OG ONIN w O Wired Zone 8 LT O LLtittl w L Expansion Module Both LLL z Supervision Duress 19 2 E Both I T Console Panic 1 amp orA 9 5 Both CICI Console Panic 3 amp or C CI Both CI TT NE Console Panic amp or B Both LLL _ Zone 1 can be used as a 2 wire Fire zone Zone 8 can be used as a Glassbreak zone 4 EXPANSION ZONES Assign zone numbers Zn 10 17 to 4219 4229 Auxiliary Wired Loops A H if used ENTER FOR Nr RF zones can use zone numbers Zn 10 31 RF ONEN ZONE ZONE ZONE PART N ALARM RPT CODE INPUT LEARNED DESCRIPTION No TYPE No Hex TYPE RF INPUT 4219 4229 Loop A 1st Exp n Zone CT opto H or RF Zones B TTI O OANT CI A C CIJ O OANT A A D LT O COATT LI CLI z LT O OTTI CLI CLI F CIJ O OATI A A G LTT O CLIT CI A H LT LI OTTI CJ Ci RF Zones LT O ATTI LI CLI LTT LI OANT CI Cu Ee O OANT ay A TTI O ATTI CI A CIJ O COATT LI CLI LT O COTTI CLI CLI LT O COTTI CLI CLI LT O LCLLItI CLI CLI RF Zones LT LI CLItt UO Cu a O eee ES FF A A EE beak ata Sie al TE slol CIT O COI TTI A EEA Ca ECE E E EA S SEa A ee LT O OATI LI CLI EXPLANATION OF ZONE ASSIGNMENT TABLE HEADINGS Zn ZONE No Zone Nos are from 01 to 31 92 95 96 99 Some are pre assigned With Field 25 set
5. RELAY OR P L C D 01 OUTPUT RELAY OR P L C D 02 OUTPUT RELAY OR P L C D 03 OUTPUT RELAY OR P L C D 04 vo of Of OO oo O o joo Oyo P L C D 06 P L C D 07 P L C D Powerline Carrier Device X 10 Where X 10 SELECT Powerline Carrier Device Enter 1 if Powerline Carrier Device is being used enter 0 if relay is being used A DEVICE ACTION 0 No Response 1 Close for 2 sec 2 Close and stay closed 3 Pulse on and off EV EVENT 0 Not used 1 Alarm 2 Fault 3 Trouble ZL ZONE LIST 1 2 or 3 from Field 81 or 0 Not Used START ZONE LIST Upon alarm fault or trouble of ANY zone on this list device action will START STOP RESTORE of ZONE LIST Upon restore of ALL zones on this list device action will STOP It need not be same list as used for START NOTE Do not use input type BR transmitters in a zone list to STOP a relay action since these transmitters do not send restores ZT ZONE TYPE SYSTEM OPERATION Choices for Zone Types are 00 Not Used 06 24 Hr Silent Note A TFT Going 01 Entry Exit 1 07 24 Hr Audible ote f K Zoe aac into a 02 Entry Exit 2 08 24 Hr Aux ault or trouble will actuate relay 03 Perimeter 09 Fire Trouble Any zone of that type that restores 04 Interior Follower 10 Interior w Delay will stop relay action 05 Trouble Day Alarm Night 24 Silent Burglary Choices for System Operation are 20 Armin
6. for auxiliary wired loops 4219 or 4229 use Zone Nos 10 17 for loops A H With Field 22 set for RF 5800 use Zone Nos 10 31 ZT ZONE TYPE 00 Not Used 05 Trouble Day Alarm Night 20 Arm Stay DEFAULT VALUE 01 Entry Exit 1 06 24 Hr Silent 21 Arm Away Zn O1 O M 02 Entry Exit 2 07 24 Hr Audible 22 Disarm ZT 09 01 03 03 03 Perimeter 08 24 Hr Aux 23 No Alarm Response n 06 07 08 04 Interior Follower 09 Fire 24 Silent Burglary ZT 03 03 03 03 06 10 Interior w Delay P PARTITION No 1or2 Default Values for zones 01 08 1 RC ALARM REPORT CODE Two Hex Digits For each Hex Digit enter 00 09 for 0 9 10 for A 11 for B 12 for C 13 for D 14 for E 15 for F If 00 is entered as the first digit there will be no report for that zone For contact ID reporting this is enabling code only Enter any hex digit other than 00 in the first pair of boxes The second pair of boxes is ignored In LOOP INPUT TYPE HW Hard Wire Enter 2 for AW Auxiliary wired Hard wire zone input AW Aux Wire 4219 or 4229 Enter 3 for RF Supervised RF types are automatically Enter 4 for UR Unsupervised RF assigned Enter 5 for BR Button Type RF RT RESPONSE TIME 0 10msec 1 350 msec 2 700 msec Default Values for zones 01 08 1 350 msec L LEARNED RF INPUT Used with 5800 RF Loop Input Devices Record transmitter input number aye TO PROGRAM SYSTEM STATUS amp RE
7. CODE Part 1 tt AWAY STAY Part 2 tt AWAY STAY T 2nd digit is automatically sent as the 2nd digit of the zone alarm report code programmed in 56 if expanded or 4 2 reporting is selected 2nd digit is automatically sent as the user number if expanded or 4 2 reporting is selected 67 RF XMTR LOW BAT REPORT CODE 68 CANCEL REPORT CODE RESTORE REPORT CODES 70 76 Default for all restore report codes 00 ALARM RESTORE RPT CODE 2nd digit is automatically sent as the 2nd digit of the zone alarm report code programmed in 56 if expanded or 4 2 reporting is selected 70 71 TROUBLE RESTORE RPT CODE 72 BYPASS RESTORE RPT CODE 73 AC RESTORE RPT CODE t 74 LOW BAT RESTORE RPT CODE t t Reports with Partition 1 Subscriber No 91 OPTION SELECTION AAV 92 93 94 95 98 99 75 RF XMTR LO BAT RST RPT CODE 76 TEST RESTORE RPT CODE OUTPUT AND SYSTEM SETUP 80 93 80 OUTPUT RELAYS AND POWERLINE CARRIER DEVICES Program only if Relays and or Powerline Carrier devices are to be ZONE LISTS FOR OUTPUT used See next page DEVICES 82 CUSTOM ALPHA EDITING Also entered from field 56 See procedure in instructions 83 SEQUENTIAL LEARN MODE Also entered from field 56 See procedure in instructions 89 EVENT LOG 80 FULL RPT CODE 90 EVENT LOGGING 3 0 N
8. Features Q E D programming for quick PreviousMens enrollment of devices VIS TA 20SE 2 PARTITIONED SECURITY SYSTEM PROGRAMMING FORM ADEMCO Principal changes between the VISTA 20SE and the former VISTA 20 are indicated by margin lines VISTA 20PRV4 8 97 See Instructions N7526V4 Field Local programming requires the use of a 2 line Alpha keypad connected to partition 1 keypad terminals on the control NOTE For UL installations the system may be configured as a single partition only Function SYSTEM SETUP 20 29 20 21 INSTALLER CODE QUICK ARM ENABLE RF SYSTEM FORCED BYPASS RF HOUSE ID CODE WIRED ZONE EXPANSION CHIME BY ZONE X 10 HOUSE CODE PHONE MODULE ACCESS CODE OUTPUT TO LONG RANGE RADIO ZONE SOUNDS AND TIMING 31 39 31 32 SINGLE ALARM SOUNDING ZONE FIRE SOUNDER TIMEOUT ALARM BELL TIMEOUT EXIT DELAY ENTRY DELAY 1 zone type 01 Programmed Values Default Value Enter 4 digits 0 9 0 Part 1t Part 2t 0 no 1 yes 0 0 none 1 5800 5881 5882 0 0 Par 1t Part 2t 0 none 1 bypass open zones 0 for UL installations 0 0 00 disable all wireless keypad usage 01 31 using 5827 keypad Partition 2 RF House ID Partition 1 House ID 1 t o 0 none 1 4219 2 4229 3 4204 T o 0 no 1 yes program zones to chime on zone list 3
9. STORE REPORT CODES 59 76 amp 89 With a 3 1 or 4 1 Standard Format Enter a code in the first box 1 9 0 B C D E or F Enter 10 for 0 11 for B 12 for C 13 for D 14 for E 415 for F A 0 not 10 in the first box will disable a report A 0 not 10 in the second box will result in auto matic advance to the next field when programming With an Expanded or 4 2 Format Enter codes in both boxes 1st and 2nd digits for 1 9 0 or B F as described above A 0 not 10 in the second box will eliminate the ex panded message for that report A 0 not 10 in both boxes will disable the report With Ademco Contact ID Reporting Enter any digit other than 0 in the first box to enable zone to report entries in the second boxes will be ignored A 0 not 10 in the first box will disable the report Examples For Code 3 single digit enter 3 0 3 2 411 2 For Code 3 2 two digits enter For Code B 2 Hexadecimal enter SYSTEM STATUS REPORT CODES 59 68 Default for all report codes 00 EXIT ERROR REPORT CODE TROUBLE REPORT CODE 61 BYPASS REPORT CODE 59 60 62 AC LOSS REPORT CODE t 63 LOW BAT REPORT CODE t 64 TEST REPORT CODE 65 OPEN REPORT CODE Part 1 tt Part 2 TT 66 ARM AWAY STAY RPT
10. Y PHONE No PRIMARY SUBS ACCT Part 1 SECONDARY SUBS ACCT Part 1 PRIMARY SUBS ACCT Part 2 SECONDARY SUBS ACCT Part 2 NOTE If using the paging feature do not enter a __ 60 60 Part 1T Part 2T 00 99 entry delay 2 time for each partition 50 seconds max for UL installations 1 1 Part 17 Part 2T 0 no 1 yes 0 0 Part 1T Part 2T 0 no 1 yes wired keypads and RF 2 yes RF only to 0 no 1 yes 1 for UL installations Enter 6 digits If fewer than 6 digits are entered exit by pressing and press 41 if entering next field To clear entries from field press 40 Enter up to 16 digits Do not fill unused spaces If fewer than 16 digits entered exit by pressing and press 42 if entering next field To clear entries from field press 41 Enter up to 16 digits Do not fill unused spaces If fewer than 16 digits entered exit by pressing and press 43 if entering next field To clear entries from field press 42 For fields 43 46 Enter 0 9 11 for B 12 for C 413 for D 14 for E 15 for F Enter as 4th digit if 3 1 dialer reporting is to be used If only 3 digits used exit by pressing fat te 24 and press next field To clear entries from field press 43 44 45 or 46 Examples
11. g Stay 38 Chime 52 Kissoff 21 Arming Away 39 Any Fire Alarm 58 Duress 22 Disarming Code OFF 40 Bypassing 31 End of Exit Time 41 AC Power Failure 32 Start of Entry Time 42 System Battery Low 33 Any Burglary Alarm 43 Communication Failure 36 At Bell Timeout Note In normal operation mode Use 0 Any for Partition No P entry Code 7 N Key Entry starts Device N Or at Disarming whichever occurs earlier Code 8 N Key Entry stops Device N P PARTITION No 1 2 or 0 for Any 81 ZONE LISTS FOR OUTPUT DEVICES This is an interactive mode Fill in the required data on the worksheet below and follow the procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence Note Record desired zone numbers below More or fewer boxes than shown may be needed since any list may include any or all of system s zone numbers alien Eimi TIT TC CIC FI 5 mi 5 mi 7 N alan Or TIP colo Fn 5 Bl 7 Bl 7 4 N Zone List 3 Started or stopped by zone numbers AND OR assignment of Chime zones enter 00 to end entries OO OC OO OO OOC OO OO OL OL Ue Zone List 4 Assignment of common lobby zones enter 00 to end entries OO OO OO OL OC OLI mia LILI OL Lee SPECIAL MESSAGES OC OPEN CIRCUIT no communication between Console and Control EE or ENTRY ERROR ERROR invalid field number entered re enter
12. ms Troubles and a 3 digit user or zone number 8 All reports Alarms Open Close Troubles See Installation Instructions for an explanation 9 All except Open Close Alarms Open Close for of the 10 digit code users 5 25 users 5 16 or wireless button zones 10 25 Troubles Can only be used if primary reporting format is Ademco Contact ID 50 15 SEC DIALER DELAY BURG T 0 0 no 1 yes 0 for UL installations 51 PERIODIC TEST REPORT T 0 0 none 1 24 hours 2 weekly 3 30 days Enter Test Code in field 64 Reports with Partition 1 subscriber No 52 TEST REPORT OFFSET t 2 0 24 hour 1 6 hours 2 12 hours 3 18 hours Time to 1st report from programming or downloading 53 SESCOA RADIONICS SELECT 0 0 Radionics 0 9 B F reporting 1 SESCOA 0 9 only reporting Select 0 for all other formats T Entry of a number other than one specified will give unpredictable results 56 ZONE ASSIGNMENT ALARM REPORT CODES This field is an interactive mode Fill in the required data on the worksheet below and on next page and follow the programming procedure in the installation arena See explanation of headings on next page ZONE ZONE ZONE PART N ALARM RPT CODE INPUT RESPONSE DESCRIPTION No TYPE No Hex TYPE TIME Zn ZT P RC In RT Wired Zone 1 CIJ CLI OATI w CL wreazone2 EA CLI Cl ON w GO wiedzores OA
13. one 1 Alarm Alarm Restore 2 Trouble Trouble Restore 4 Bypass Bypass Restore 8 Open Close Example To select Alarm Alarm Restore and Open Close enter 9 1 8 To select all enter 15 Note System messages are logged when any non zero selection is made 0 0 None 4 AAV 0 for UL installations PHONE LINE MONITOR ENABLE 0 Not used 1 Keypad display when line is faulted 2 Keypad display plus keypad trouble sound 3 Same as 2 plus Device 2 STARTS If either partition is armed external sounder activates also Note Device 2 must either be programmed to be STOPPED in field 80 or STOPPED by Code 8 2 No OF REPORTS IN ARMED PERIOD 0 0 10 Alarm Alarm Restore Reports 1 Unlimited 1 for UL installations DOWNLOAD INFORMATION 94 95 DOWNLOAD PHONE No 0 Enter up to 16 digits 0 9 4 11 for 12 for 413 for a pause Do not fill unused spaces If fewer than 16 digits entered exit field by pressing and press 95 if entering next field To clear entries from field press 94 Note In UL installations down loading may only be performed if a technician is at the site RING DET COUNT FOR DOWNLOADING O 0 Disable Station Initiated Download 1 14 number of rings 1 9 10 10 411 11 12 12 13 13 14 14 15 answering machine defeat 15 15 Note Do not enter
14. valid field number After powering up AC dl disabled or Busy Standby and NOT READY will be displayed after approximately 4 seconds This will revert to READY in appx 1 minute which allows PIRS etc to stabilize To bypass this delay press 0 lf E4 or E8 appears more zones than the expansion units can handle have been programmed Correct the programming and then completely de power and re power the control to clear this indication and remove the disable indication TO ENTER PROGRAMMING MODE 1 POWER UP then depress and both at once within 50 seconds of powering up OR 2 Initially key Installer Code 4 1 1 2 plus8 0 0 OR 3 If different Installer Code is programmed key New Installer Code 8 0 0 if 98 was used to exit previously method 1 above must be used to enter the program mode again TO EXIT PROGRAMMING MODE 98 Exits programming mode and prevents re entry by Installer Code 8 0 0 If 98 is used to exit programming mode system must be powered down and method 1 above used to enter the programming mode 99 Exits programming mode and allows re entry by Installer Code 8 0 0 or Power up then press and within 50 seconds of power up ADEMCO ALARM DEVICE MANUFACTURING CO A DIVISION OF PITTWAY CORPORATION 165 Eileen Way Syosset New York 11791 Copyright 1997 PITTWAY CORPORATION