Home

Viking Technology Technology Computer Drive viking User's Manual

image

Contents

1. F Fixed Word V Variable Default Value Description X Both General configuration bit significant i Goaan information Obsolete Number of logical cylinders 1 X 3FFFh 16383 2 V C837h Specific configuration 3 X 0010h Obsolete Number of logical heads 16 4 5 X 00000000h Retired Obsolete Number of logical sectors per i gt O0AFN logical track 63 Reserved for assignment by the Compact re H 00000000h Flash Association 9 X 0000h Retired 10 19 F Varies Serial number 20 ASCII characters 20 21 X 0000h Retired 22 X 0000h Obsolete 23 26 F Varies Firmware revision 8 ASCII characters 27 46 F Varies Model number xxxxxxxx 7 0 Maximum number of sectors transferred d F PEUN per interrupt on MULTIPLE commands 48 F 0000h Reserved 49 F 2F00h Capabilities 50 F 4000h Capabilities 51 52 X 000000000h Obsolete 53 F 0007h Words 88 and 70 64 valid Obsolete Number of logical cylinders 54 X 3FFFh 16383 55 X 0010h Obsolete Number of logical heads 16 56 X 003Fh sel Number of logical sectors per track 57 58 X OOFBFC10h Obsolete Current capacity in sectors Number of sectors transferred per interrupt on a3 j Oren MULTIPLE commands 60 61 F 8GB 128GB Total number of user addressable sectors 62 X 0000h Obsolete 63 F 0407h Multi word DMA modes supported selected 64 F 0003h PIO modes supported 65 F 0078h Minimum Multiword DMA transfer cycle time per
2. mSATA FULL SIZE VARIATION A Notes All dimensions are in millimeters Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 28 of 43 www vikingtechnology com viking TECHNOLOGY 3 1 mSATA SSD Weight The weight of the mSATA mini SATA MO 300 SSD is approximately 8 grams 4 Pin and Signal Descriptions 4 1 Signal and Power Description Tables Table 4 1 Mini PCle Connector Pin Signal Definitions Pin Type Description P1 Reserved No Connect P2 3 3V or 5 0V 3 3V or 5 0V Source P3 Reserved No Connect P4 GND Return Current Path P5 Reserved No Connect P6 Reserved No Connect P7 Reserved No Connect P8 Reserved No Connect P9 GND Return Current Path P10 Reserved No Connect P11 Reserved No Connect P12 Reserved No Connect P13 Reserved No Connect P14 Reserved No Connect P15 GND Return Current Path P16 Reserved No Connect P17 Reserved No Connect P18 GND Return Current Path P19 Reserved No Connect P20 Reserved No Connect P21 GND Return Current Path P22 Reserved No Connect P23 B Host Receiver Differential Signal Pair P24 3 3V or 5 0V 3 3V or 5 0V Source P25 B Host Receiver Differential Signal Pair P26 GND Return Current Path P27 GND Return Current Path P28 Reserved No Connect Manual 7 24 2014 PSFEM2xxxGRxxx Viking T
3. 00h Host write 64GB count 0 0 0 00h F2h 32h 00h 00h 00h Host read 64GB count 0 y 0 00h F3h oahi ooh 64h 64h Total internal copy ecc error count 9 0 00h F4h 02h 00h 64h 64h Total Average erase count 9 0 0 goti E5h 02h 00h 64h 64h Max eraseco nt 0 0 0 00h E6h 02h 00h 64h 64h Total Erase Count 0 00h EAh 02h 00h 64h 64h Read retry Count 0 00h EBh 02h 00h 64h 64h Cool down Count 0 00h Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 40 of 43 www vikingtechnology com viking TECHNOLOGY 0 1 2 3 4 5 6 7 8 9 10 11 ID Flag Flag Value Worse DATA Threshold ECh 02h 00h 64h 64h CRC write Count 0 00h Note 1 Formula MABN Maximum acceptable bad block number CBBN Current bad block number Value MABN CBBN MABN x 100 This formula calculates percentage of spare blocks Value will be from 100 to 1 Note 2 Average erase count MAX erase count SLC 100000 MLC 5000 100 percentage 5 1 2 2Off line Mode SSD s support the optional 28 bit S M A R T EXECUTION OFF LINE IMMEDIATE BOh D4h command per the ATA 8 specification This command causes the SSD to initiate the collection of S M A R T data in an off line mode and then preserves this data across power and reset events Supported subcommands include those shown in the table below Reference the ATA 8 specification for subcommand detail Table 5 7 Supported S M
4. 4 1 Temperature and Altitude Table 2 9 Temperature and Altitude Related Specifications Conditions Operating Shipping Storage Commercial O to 70 C 40 to 85 C 40 to 85 C Temperature 32 to 158 F 40 to 185 F 40 to 185 F Ambient Industrial 40 to 85 C 40 to 85 C 40 to 85 C Temperature 40 to 185 F 40 to 185 F 40 to 185 F Ambient Humidity non 95 under 55C 95 under 55C 95 under 55C condensing Notes 1 SLC flash based products may be available in the following temperature ranges a Commercial temperature range of 0 to 70 C 32 to 158 F b Industrial temperature range 40 to 85 C 40 to 185 F Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 15 of 43 www vikingtechnology com viking TECHNOLOGY 2 4 2 Shock and Vibration SSD products are tested in accordance with environmental specification for shock and vibration Table 2 10 Shock and Vibration Specifications Stimulus Description Shock 50g 11ms 3 shocks applied in each direction on 3 mutually perpendicular axes X Y Z Vibration 16 4g rms 10 2 000 Hz 3 axes 2 4 3 Electromagnetic Immunity mSATA is an embedded product for host systems and is designed not to impair with system functionality or hinder system EMI FCC compliance 2 5 Reliability Table 2 11 Reliability Specifications Parameter VRFEM2xxxGRxxx ECC 72 bit per 1KByte Read E
5. Extended SMART Attribute Actual Data Oih OBh 00h 64h 64h 0 0 ECC error 0 0 0 0 32h 05h 13h OOh 64h 64h 0 0 0 0 0 0 0 32h Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 39 of 43 www vikingtechnology com vikin g TECHNOLOGY 0 1 2 3 4 5 6 7 8 9 10 11 ID Flag Flag Value Worse DATA Threshold 09h 12h 00h 64h 64h Power on hour 0 0 0 0 0 00h OCh 12h 00h 64h 64h Power on off cycles 0 0 0 00h A8h 12h ooh 64h 64h SATA PHY error count 0 0 0 00h Later bad block AAh 03h 00h Note 1 Note 1 Early bad block NO 0 0 NO 0 OAh 12h ooh 64h 64h M x erase count wo 00 0 00h ADh MAX 65535 MAX 65535 Bih 00h 00h 00h 00h The value 0 0 0 00h B5h 12h 00h 00h 00h Total program bad blocks count 0 0 0 00h B6h 32h 00h 00h 00h Total erase bad blocks count 0 0 0 00h BBh 03h 00h 00h 00h Total ECC error count 0 0 0 00h Coh 12h 00h 64h 64h number of accidental power loss count 0 0 0 00h 22h 00h Value Max 00 00 00 0 00h C2h value C7h 12h 00h 64h 64h CRC Error Count R CRC W CRC 0 0 0 00h DA OBh 00h 64h 64h Number of CRC Error 0 0 0 32h Sti el eee pah SSD life remaining Note 2 i o o ooh E8h oe om i oan Total Read bad Block Count E 9 9 00h E9h oan 00h 64h Gah Flash write 64GB each count 0 0 0 oon Fih 32h 00h 00h
6. com viking TECHNOLOGY 1 Introduction Viking s rugged industrial designed SSD s offer the highest flash storage reliability and performance in harsh environments such as shock vibration humidity altitude ESD and extreme temperatures 1 1 Features The SSD delivers the following features e Offers seamless SATA Revision 3 0 interface support for SATA up to 6Gb s e Low overall SSD power consumption e Supports Native Command Queuing NCQ to 32 commands e Compatible with all major SLC MLC and eMLC flash technologies e S M A R T e Superior wear leveling algorithm e Efficient error recovery Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 10 of 43 www vikingtechnology com viking TECHNOLOGY 1 2 Block Diagram Figure 1 1 High Level Block Diagram 3 3V or 5 0V SATA Controller PHY and 8 Channel Flash Controller Notes 5V not supported on VRFEM2xxxGRxxxJx PN s Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 11 of 43 www vikingtechnology com viking TECHNOLOGY 1 3 SATA Interface e The Serial ATA SATA interface is compliant with the SATA IO Serial ATA specification revision 3 0 that supports SATA up to 6Gb s e The SATA interface connects the host computer to the SSD subsystem e The SATA interface runs at a maximum speed of 6 Gbps Giga bits per second If the host computer is una
7. device specific words Use the following list to define a variety of terms and acronyms ATA Advanced Technology Attachment ATAPI Advanced Technology Attachment Packet Interface Bit error rate or percentage of bits that have errors relative to the total number of bits BER received Device Initiated Link Power Management The ability of the device to request SATA link DIPM power state changes DMA Direct Memory Access eMLC Enterprise Multi Level Cell EXT Extended FP First Party GB Giga byte defined as 1x10 bytes HDD Hard Disk Drive A term used to describe the removal or insertion of a SATA storage drive when the Hot Plug system is powered on IOPS Input output operations per second LBA Logical Block Address MB Mega bytes defined as 1x10 bytes MLC Multi Level Cell MTBF Mean Time Between Failures Native Command Queuing The ability of the SATA hard drive to queue and re order NCQ commands to maximize execution efficiency NOP No Operation OS Operating System Port The point at which a SATA drive physically connects to the SATA controller RMS Root Mean Squared RPM Revolutions Per Minute SAS Serial Attached SCSI SATA Serial ATA SFF Small Form Factor SLC Single Level Cell Self Monitoring Analysis and Reporting Technology an open standard for developing hard drives and software systems that automatically monitors a hard drive s he
8. retry 21h Write multiple C5h Read sector s w retry 20h Write multiple Ext 39h Read sector s Ext 24h Write multiple FUA Ext CEh Read Verify Ext 42h Write sector s w o retry 31h Read verify sector s w o retry 4th Write sector s w retry 30h Read verify sector s w retry 40h Write sector s Ext 34h Recalibrate 10h Write uncorrectable 45h Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 31 of 43 www vikingtechnology com viking TECHNOLOGY 5 1 1 48 Bit Address Command Set SSD supports the 48 Bit Address command set consisting of e Flush Cache Ext Read DMA Ext Read native Max Address Ext Read Sector s Ext Set Max Address Ext Write DMA Ext Write Multiple Ext Write Sector s Ext 5 1 2 ATA General Feature Command Set SSD supports the ATA General Feature command set consisting of e Download Microcode Executive Device Diagnostics Flush Cache Identify Device NOP optional Read Buffer optional Read DMA Read Multiple Read Sector s Read Verify Sector s Seek Set Features Set Multiple Mode Write Buffer optional Write DMA Write Multiple Write Sector s 5 1 3 Device Configuration Overlay Command Set SSD supports the Device Configuration Overlay command set consisting of e Device Configuration Freeze Lock e Device Configuration Identity e Device Configuration Restore e Device Configuration Set 5 1 4 General Purpose Log Command Set SSD supports the Gen
9. word 66 F 0078h Manufacturer s recommended Multiword DMA transfer cycle time Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 34 of 43 www vikingtechnology com viking TECHNOLOGY F Fixed Word V Variable Default Value Description X Both 67 F 0078h Minimum PIO transfer cycle time without flow control Minimum PIO transfer cycle time with IORDY oe j da flow control Additional Supported support download 93 i eon microcode DMA ee 70 F 0000h Reserved 000000000000000 Reserved for the IDENTIFY PACKET DEVICE 71 74 F Oh command 75 F 001Fh Queue depth 76 F 0706h Serial SATA capabilities 77 F 0000h Reserved for future Serial ATA definition 78 F 0044h Serial ATA features supported 79 V 0040H Serial ATA features enabled 80 F 01F8h Major Version Number 81 F 0000h Minor Version Number 82 F 346Bh Command set supported 83 F 70D9h Command set supported 84 F 6023h Command set feature supported extension 85 V 3469h Command set feature enabled 86 V BCOth Command set feature enabled 87 V 6023h Command set feature default 88 V 003Fh Ultra DMA Modes Time required for security erase unit 8a i Ovien Ba 90 F 001Eh Time required for Enhanced security erase completion 91 V 0000h Current advanced power management value 92 V FFFEh Master Password Revision Code Hardware reset res
10. A R T EXECUTE OFF LINE IMMEDIATE Subcommands Value Description 00h Execute S M A R T off line routine immediately in off line mode 01h Execute S M A R T Short self test routine immediately in off line mode 02h Execute S M A R T Extended self test routine immediately in off line mode 04h Execute S M A R T Selective self test routine immediately in off line mode 7Fh Abort off line mode self test routine 81h Execute S M A R T Short self test routine immediately in captive mode 82h Execute S M A R T Extended self test routine immediately in captive mode 84h Execute S M A R T Selective self test routine immediately in captive mode 5 2 SATA Commands The SATA 2 6 specification is a super set of the ATA ATAPI 7 specification with regard to supported commands SSD s support the following features that are unique to the SATA specification Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 41 of 43 www vikingtechnology com VIKING 5 2 1 Native Command Queuing NCQ SSD s support the Native Command Queuing NCQ command set which consists of e READ FPDMA QUEUED e WRITE FPDMA QUEUED Note With a maximum queue depth less than or equal to 32 6 References e Serial ATA Specification Revision 3 Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 42 of 43 www vikingtechnology com viking TECHNOLOGY 7 Glossary This document incorporates many industry and
11. Command BSY DRDY DF na DRQ na na ERR Device Head Register DEV shall indicate the selected device Status Register BSY shall be cleared to zero indicating command completion DRDY shall be set to one DF Device Fault shall be cleared to zero DRQ shall be cleared to zero ERR shall be cleared to zero Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 23 of 43 www vikingtechnology com viking TECHNOLOGY 2 6 2 6 NISPOMSUP CHAP 8 SECT 8 501 Pattern 1 To fill the whole disk with fixed character pattern of 0x55 2 To fill the whole disk with fixed character pattern of OxAA 3 To fill the whole disk with random data Input Info of Executing NISPOMSUP chap 8 Sect 8 501 Command Register 7 6 5 4 3 2 1 0 Features 07h Sector Count 2Fh Sector Number na Cylinder High na Cylinder Low na Device Head AOh Command 6Fh Normal Output Info of Executing NISPOMSUP chap 8 Sect 8 501 Command Register 7 6 5 4 3 2 al 0 Features na Sector Count na Sector Number na Cylinder High na Cylinder Low na Device Head obs na obs DEV na na na na Command BSY DRDY DF na DRQ na na ERR Device Head Register DEV shall indicate the selected device Status Register BSY shall be cleared to zero indicating command completion DRDY shall be set to one DF Device Fault shall be cleared to zero DRQ shall be cleared to zero ERR shall be cleared to zero Manual 7 24 2014 PSFEM2xx
12. Manual 130 2 Command Register 7 6 5 4 3 2 1 0 Features 05h Sector Count 2Fh Sector Number na Cylinder High na Cylinder Low na Device Head AOh Command 6Fh Normal Output Info of Executing NSA Manual 130 2 Command Register 7i 6 5 4 3 2 al 0 Features na Sector Count na Sector Number na Cylinder High na Cylinder Low na Device Head obs na obs DEV na na na na Command BSY DRDY DF na DRQ na na ERR Device Head Register DEV shall indicate the selected device Status Register BSY shall be cleared to zero indicating command completion DRDY shall be set to one DF Device Fault shall be cleared to zero DRQ shall be cleared to zero ERR shall be cleared to zero Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 22 of 43 www vikingtechnology com viking TECHNOLOGY 2 6 2 5 USA ARMY 380 19 Pattern 1 To erase the whole disk 2 To fill the whole disk with random data 3 To fill the whole disk with fixed character pattern of 0x55 4 To fill the whole disk with fixed character pattern of OxAA Input Info of Executing USA Army 380 19 Command Register 7 6 5 4 3 2 1 0 Features 06h Sector Count 2Fh Sector Number na Cylinder High na Cylinder Low na Device Head AOh Command 6Fh Normal Output Info of Executing USA Army 380 19 Command Register 7 6 5 4 3 2 1 0 Features na Sector Count na Sector Number na Cylinder High na Cylinder Low na Device Head obs na obs DEV na na na na
13. SD s using Synchronous NAND devices ONFI or toggle mode i e 30GB 2 2 Timing Table 2 3 Timing Specifications Type Average Latency Power On to Ready POR 550 ms Command to DRQ 600 usec Time to Erase ATA Secure Erase 9 sec Notes 1 2 3 4 5 Device measured using Drivemaster Sector Read Write latency measured up to 2048 block transfers 512B sector 1 Block Queue depth set to 32 for NCQ Sequential IOPS cover the entire range of legal logical block addresses LBA s Measurements are performed on a full drive all LBA s have valid content DRQ Data Transfer Requested bit being asserted 2 2 1 STANDBY IMMEDIATE Command The Power On to Ready time assumes a proper shutdown power removal preceded by STANDBY IMMEDIATE command A STANDBY IMMEDIATE before power down always performs a graceful shutdown and does not require Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 13 of 43 www vikingtechnology com viking TECHNOLOGY the use of the hold up circuit Note that SMART attribute 174 Unexpected Power Loss records the number of non graceful power cycle events Table 2 4 STANDBY IMMEDIATE Timing Power Cycle Endurance Unit STANDBY IMMEDIATE to WE completed 72 9 ms Notes From Standby Immediate command to NAND Write Protect enable 2 3 Electrical Characteristics 2 3 1 Absolute Maximum Rati
14. alth and S M A R T reports potential problems SSD Solid State Drive Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 43 of 43 www vikingtechnology com
15. bd 3h 2 5 inch 168 F 4h 1 8 inch Device Nominal Form Factor 5h lt 1 8 inch DATA SET MANAGEMENT command is 169 F 0001h supported 170 173 F Oh Additional Product Identifier 174 175 Oh Reserve 176 205 V Oh Current media serial number 206 F Oh SCT Command Transport 207 208 F Oh Reserved 209 F 4000h PEN of logical blocks within a physical 210 211 V 0000h Write Read Verify Sector Count Mode 3 not supported Write Read Verify Sector Count Mode 2 not 212 213 F 0000h ae 214 216 0000h NV Cache relate not supported 217 F 0001h Non rotating media device 218 F Oh Reserved 219 F Oh NV Cache relate not supported 220 V Oh Write read verify feature set current mode 221 Oh Reserved 222 F 101Fh Transport major version number 223 F Oh Transport minor version number 224 229 Oh reserved 230 233 Oh Extend number of user addressable sectors Minimum number of 512 byte data blocks per 234 0001h DOWNLOAD MICROCODE command for mode 03h 235 OOFFh Maximum number of 512 byte data blocks per Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 36 of 43 www vikingtechnology com viking TECHNOLOGY DOWNLOAD MICROCODE command for mode 03h 236 254 F Oh Reserved XXA5h 255 X XX is variable Integrity word Checksum and Signature Table 5 3 Capacity specific Device Identification 32 tod tbd tbd tod 64 tod tod tod tod 128 tod tod tod tod 256 tod tod tbd tod 512 t
16. ble to negotiate a speed of 6 Gbps the SATA interface automatically renegotiates to a speed of 3 Gbps or 1 5 Gbps For a list of supported commands and other specifics please see Chapter 5 Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 12 of 43 www vikingtechnology com viking TECHNOLOGY 2 Product Specifications 2 1 Performance Table 2 1 Maximum Sustained Read and Write Bandwidth Access Type VRFEM2xxxGRxxx Sequential Read 256K Up to 508 MB s Sequential Write 256K Up to 364 MB s Notes 1 Performance measured using Ometer 06 with queue depth set to 32 2 Write Cache enabled with DDR cache 3 Refer to Application Note ANO006 for Viking SSD Benchmarking Methodology 4 Data is based on SSD s using Synchronous NAND devices ONFI or toggle mode Table 2 2 Random Read and Write Input Output Operations per Second IOPS Access Type VRFEM2xxxGRxxx Read 4K Up to 42 500 IOPS Write 4K Up to 1100 IOPS Notes 1 Performance measured using lometer 06 with queue depth set to 32 2 Write Cache enabled with DDR cache 3 Random IOPS cover the entire range of legal logical block addresses LBA s Measurements are performed on a full drive all LBA s have valid content Performance may vary by NAND type and host 4 5 Refer to Application Note ANO006 for Viking SSD Benchmarking Methodology 6 Data is based on S
17. e an unsolicited COMINIT when first mated with a powered connector to guarantee reliable detection by a host system without hardware device detection 5 Command Sets Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 30 of 43 www vikingtechnology com viking TECHNOLOGY 5 1 ATA Commands Table 5 1 Supported ATA Commands Description ce de Description ia de Check power mode E5h Security Disable Password F6h Data Set management 06h Security Erase Prepare F3h DCO Bih Security Erase Unit F4h Download Microcode PIO 92h Security Freeze Lock F5h Download Microcode DMA 93h Security Set Password Fih Execute drive diagnostic 90h Security Unlock F2h Flush cache E7h Seek 70h Flush cache Ext EAh Set features EFh Identify device ECh Set Max Address F9h Idle E3h Set Max Address Ext 37h Idle immediate Eth Set multiple mode C6h Initialize drive parameters 91h Sleep E6h Read buffer E4h Smart Boh Read DMA w o retry C9h Standby E2h Read DMA w retry C8h Standby immediate E0h Read DMA Ext 25h Write buffer E8h Read FPDMA QUEUED 60h Write DMA w o retry CBh Read Log Ext 2Fh Write DMA w retry CAh Read multiple C4h Write DMA Ext 35h Read multiple Ext 29h Write DMA FUA Ext 3Dh Read native max address F8h Write FPDMA QUEUED 61h Read native max Ext 27h Write Log Ext 3Fh Read sector s w o
18. echnology Revision A10 Page 29 of 43 www vikingtechnology com viking TECHNOLOGY Pin Type Description P29 GND Return Current Path P30 NC No Connect P31 A Host Transmitter Differential Signal Pair P32 NC No Connect P33 A Host Transmitter Differential Signal Pair P34 GND Return Current Path P35 GND Return Current Path P36 Reserved No Connect P37 GND Return Current Path P38 Reserved No Connect P39 3 3V or 5 0V 3 3V or 5 0V Source P40 GND Return Current Path P41 3 3V or 5 0V 3 3V or 5 0V Source P42 Reserved No Connect P43 GND Return Current Path P44 Reserved No Connect P45 Optional No Connect Vendor Specific Manufacturing Pin P46 Reserved No Connect P47 Optional No Connect Vendor Specific Manufacturing Pin Reserved No Connect Reserved P49 DA DSS Device Activity Signal Disable Staggered Spin up P50 GND Return Current Path P51 Presence Detection Shall be pulled to GND by device P52 3 3V or 5 0V 3 3V or 5 0V Source Notes 1 Presence detection pin provided for tamper proof functionality 2 No connect on the host side 3 5V not supported on VRFEM2xxxGRxxxJx PN s 4 2 Hot Plug Support Hot Plug insertion and removal are supported in the presence of a proper connector and appropriate operating system OS support as described in the SATA 2 6 specification This product supports Asynchronous Signal Recovery and will issu
19. eral Purpose Log command set consisting of e Read Log Ext e Write Log Ext Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 32 of 43 www vikingtechnology com viking TECHNOLOGY 5 1 5 Host Protected Area Command Set SSD supports the Host Protected Area command set consisting of e Read Native Max Address Read Native Max Address Ext Set Max Address Set Max Address Ext Set Max Freeze Lock optional Set Max Lock optional Set Max Set Password optional Set Max Unlock optional 5 1 6 Power Management Command Set SSD supports the Power Management command set consisting of e Check Power Mode Idle Idle Immediate Sleep Standby Standby Immediate Slumber Partial Mode 5 1 7 Security Mode Feature Set SSD supports the Security Mode command set consisting of e Security Set Password OPCODE Fth e Security Unlock OPCODE F2h e Security Erase Prepare OPCODE F3h e Security Erase Unit OPCODE F4h e Security Freeze Lock OPCODE F5h e Security Disable Password OPCODE F6h e Standby Immediate Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 33 of 43 www vikingtechnology com viking TECHNOLOGY 5 1 8 Identify Device Data The table below lists the sector data that will be returned by the SSD upon an IDENTIFY DEVICE command Table 5 2 List of Device Identification
20. et 38 5 2 SATA Commands 41 5 2 1 Native Command Queuing NCQ 42 6 REFERENCES 42 7 GLOSSARY 43 Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 8 of 43 www vikingtechnology com viking TECHNOLOGY Table of Tables Table 2 1 Maximum Sustained Read and Write Bandwidth Table 2 2 Random Read and Write Input Output Operations per Second IOPS Table 2 3 Timing Specifications Table 2 4 STANDBY IMMEDIATE Timing Table 2 5 Absolute Maximum Ratings Table 2 6 Operating Voltage Table 2 7 Current Draw Table 2 8 Typical Power Consumption Table 2 9 Temperature and Altitude Related Specifications Table 2 10 Shock and Vibration Specifications Table 2 11 Reliability Specifications Table 2 11 Military Secure Erase Sanitize Routines Table 4 1 Mini PCle Connector Pin Signal Definitions Table 5 1 Supported ATA Commands Table 5 2 List of Device Identification Table 5 3 Capacity specific Device Identification Table 5 4 S M A R T Command Set Table 5 5 Extended SMART Attribute Table Table 5 6 Extended SMART Attribute Actual Data Table 5 7 Supported S M A R T EXECUTE OFF LINE IMMEDIATE Subcommands Table of Figures Figure 1 1 High Level Block Diagram 11 Figure 3 1 Dimensions 27 Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 9 of 43 www vikingtechnology
21. firm that only the known pattern can be recovered NSA CSS 130 2 Erase the media and overwrite with random data 2 times Note 1 then erase and overwrite with a character DoD5220 22 M Erase the media and overwrite with single character then Note 1 erase again NISPOMSUP Erase the media and overwrite with single character then Note 1 Chap 8 Sect 8 501 erase again and overwrite with single character then erase again and overwrite with random character then erase again USA Army 380 19 Erase the media and overwrite with random data erase Note 1 and overwrite with a character then erase and overwrite with complement of the character Navy NAVSO P 5239 Erase the media and overwrite with random data then Note 1 26 erase again Air Force AFSSI 5020 Erase the media and overwrite with pattern repeat 3 times Note 1 Air Force AFSSI 8580 TBD Note 1 Notes 1 Enabled using ATA commands Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 18 of 43 www vikingtechnology com viking TECHNOLOGY 2 6 2 1 AFSSI 5020 Pattern 1 To erase the whole disk 2 To fill the whole disk with random data Input Info of Executing AFSSI 5020 Command Register 7 6 5 4 3 2 1 0 Features 02h Sector Count 2Fh Sector Number na Cylinder High na Cylinder Low na Device Head AOh Command 6Fh Normal Output Info of Executing AFSSI 5020 Command Register 7 6 5 4 3 2 1 0 Features na Sector Count na Sect
22. ge 20 of 43 www vikingtechnology com viking TECHNOLOGY 2 6 2 3 USA NAVY NAVSO P 5239 26 Pattern 1 To erase the whole disk 2 To fill the whole disk with random data 3 To erase the whole disk again Input Info of Executing USA Navy NAVSO P 5239 26 Command Register 7 6 5 Features Sector Count Sector Number Cylinder High Cylinder Low Device Head Command 04h 2Fh na na na AOh 6Fh Normal Output Info of Executing USA Navy NAVSO P 5239 26 Command Register i 6 5 Features Sector Count Sector Number Cylinder High Cylinder Low Device Head obs na obs Command BSY DRDY DF Device Head Register DEV shall indicate the selected device Status Register BSY shall be cleared to zero indicating command completion DRDY shall be set to one DF Device Fault shall be cleared to zero DRQ shall be cleared to zero ERR shall be cleared to zero 4 DEV na na na na na na 3 na DRQ 2 na na al na na 0 ERR Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 21 of 43 www vikingtechnology com viking TECHNOLOGY 2 6 2 4 NSAMANUAL 130 2 Pattern 1 To erase the whole disk 2 To fill the whole disk with random data 3 To fill the whole disk with random data one more time 4 To erase the whole disk again 5 To fill the whole disk with fixed character pattern of 0x55 Input Info of Executing NSA
23. n off cycles Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 38 of 43 www vikingtechnology com viking TECHNOLOGY SATA PHY Error Count only record from power on when power off this value will clear to zero this value include all PHY error count ex data FIS CRC code error disparity A8h error command FIS CRC Max Bad Block Count will show early bad and later bad AAh block count ADh Erase count average max erase count Wear Range delta most wear block average wear Bih block Max P E cycles x 100 B5h Program Fail Count B6h Erase Failure Block Count Reported Uncorrectable Errors ECC fail count 4bytes 01h BBh only 1 bytes CoOh Unexpected Power Loss Count C2h Temperature only Toshiba or thermo sensor embedded Number of accumulated CRC Error read write data FIS C7h CRC error CRC Error Count R CRC W CRC Number of accumulated CRC Error read write data FIS DAh CRC error Number of CRC Errors E7h SSD life remaining E8h Read Failure Block Count E9h Lifetime Writes to Flash GB Fih Lifetime Writes from Host each G F2h Lifetime Reads from Host each G F3h Total internal copy ecc error count F4h Average erase count 4bytes F5h Max erase count 4 bytes F6h Total Erase Count 6 bytes FAh Read retry count FBh Do wearleveling count FCh CRC error write count Notes Dummy is null and not used Table 5 6
24. ndurance Unlimited Write Endurance specified by the flash component Data retention gt 90 days at NAND expiration 2 6 Data Security Viking s mSATA SSD s are self encrypting drives SED with a bulk data encryption feature that provides automatic hardware based data security and enhanced secure erase capability A self encrypting drive scrambles data using a data encryption key as it is written to the drive and then descrambles it with the key as it is retrieved This gives the user the highest level of data protection available and provides a fast erase simply by deleting the encryption key eliminating the need for time consuming data overwrite Data on the drive is instantly rendered unreadable The mSATA SSD supports AES 128 encryption AES 256 encryption and ATA Secure Erase features to protect sensitive data The drive is also available with TCG security enhancements and support the following security features e AES 128 256 on the fly support e RSA 512 1024 2048 e SHA 160 256 512 Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 16 of 43 www vikingtechnology com viking TECHNOLOGY 2 6 1 Quick Erase Quick Erase has been designed to remove data under prompt and urgent situation and is triggered by sending an ATA Command Input Info of Executing Quick Erase Command Register 7 6 S 4 3 2 1 0 Features Oih Sector Count 2Fh Sector Number na Cylinder High na C
25. ngs Values shown are stress ratings only Functional operation outside normal operating values is not implied Extended exposure to absolute maximum ratings may affect reliability Table 2 5 Absolute Maximum Ratings Description Min Max Unit Maximum Voltage Range for Vin 0 2 6 V Maximum Temperature Range 40 85 c 2 3 2 Supply Voltage The operating voltage is 3 3V or 5 0v Table 2 6 Operating Voltage Description Min Max Unit Operating Voltage for 3 3 V or 5 0 5 3 135 5 25 V Notes 5V not supported on VRFEM2xxxGRxxxJx PN s Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 14 of 43 www vikingtechnology com viking TECHNOLOGY 2 3 3 Supply Current Table 2 7 Current Draw Voltage Mode Typical Unit Read Writes Average RMS 850 600 mA 3 3V Idle 80 mA Slumber 14 mA Read Writes Average RMS tbd mA 5 0V Idle tbd mA Slumber tbd mA Notes 1 Measured using 60GB MLC VRFEM2060GRCYMTJ 2 5V not supported on VRFEM2xxxGRxxxJx PN s 2 3 4 Power Consumption All onboard power requirements of the SSD are derived from the SATA 3 3V or 5 0V input rail Note 5V not supported on VRFEM2xxxGRxxxJx PN s Table 2 8 Typical Power Consumption Mode Typical Unit Active tod W Idle tod W 2 4 Environmental Conditions 2
26. od tod tbd tod 1000 tod tod tod tod 5 1 1 S M A R T Support Data storage drives capture a variety of information during operation that may be used to analyze drive health SATA drives provide Self Monitoring Analysis and Reporting Technology SMART features that include monitoring and storing critical performance and calibration parameters to attempt to predict the likelinood of near term degradation or fault conditions Drive manufacturers have adopted S M A R T to help warn system software a system administrator or a user of impending drive failure while time remains to take preventive action It provides the host system with the knowledge of a negative reliability condition to allow the host system to warn the user of the impending risk of data loss and advise the user of the appropriate action The technical documentation for S M A R T is captured in the AT Attachment ATA standard The standard defines the protocols for reporting errors and for invoking self tests to collect and analyze data on demand The ATA specification is flexible and provides for individual manufacturers to define their own unique vendor specific information This section describes the baseline supported S M A R T command attributes The information herein should be used in conjunction with the ATA standard and related documents which may serve as Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 37 of 43 w
27. or Number na Cylinder High na Cylinder Low na Device Head obs na obs DEV na na na na Command BSY DRDY DF na DRQ na na ERR Device Head Register DEV shall indicate the selected device Status Register BSY shall be cleared to zero indicating command completion DRDY shall be set to one DF Device Fault shall be cleared to zero DRQ shall be cleared to zero ERR shall be cleared to zero Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 19 of 43 www vikingtechnology com viking TECHNOLOGY 2 6 2 2 DOD 5220 22 M Pattern 1 To fill the whole disk with fixed character pattern of 0x55 2 To erase the whole disk Input Info of Executing DoD 5220 22 M Command Register 7 6 5 4 3 2 1 0 Features 03h Sector Count 2Fh Sector Number na Cylinder High na Cylinder Low na Device Head AOh Command 6Fh Normal Output Info of Executing DoD 5220 22 M Command Register 7 6 5 4 3 2 al 0 Features na Sector Count na Sector Number na Cylinder High na Cylinder Low na Device Head obs na obs DEV na na na na Command BSY DRDY DF na DRQ na na ERR Device Head Register DEV shall indicate the selected device Status Register BSY shall be cleared to zero indicating command completion DRDY shall be set to one DF Device Fault shall be cleared to zero DRQ shall be cleared to zero ERR shall be cleared to zero Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Pa
28. rmation Copyright 2014 Sanmina Corporation All rights reserved The information in this document is proprietary and confidential to Sanmina Corporation No part of this document may be reproduced in any form or by any means or used to make any derivative work such as translation transformation or adaptation without written permission from Sanmina Sanmina reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of Sanmina to provide notification of such revision or change Sanmina provides this documentation without warranty term or condition of any kind either expressed or implied including but not limited to expressed and implied warranties of merchantability fitness for a particular purpose and non infringement While the information contained herein is believed to be accurate such information is preliminary and should not be relied upon for accuracy or completeness and no representations or warranties of accuracy or completeness are made In no event will Sanmina be liable for damages arising directly or indirectly from any use of or reliance upon the information contained in this document Sanmina may make improvements or changes in the product s and or the program s described in this documentation at any time Sanmina Viking Technology Viking Modular Solutions and Element logo are trademarks of Sanmina Corporation Other company product or service name
29. s mentioned herein may be trademarks or service marks of their respective owners Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 3 of 43 www vikingtechnology com viking Ordering Information mSATA SSD Solid State Drive SATA ae Raw Useable Addressable NAND Part Numbers Interface Application Capacity Capacity Sectors in Technology Temperature GB GB LBA Mode Range VRFEM2030GRIWMxx 6Gbps Industrial 32 30 58 626 288 MLC 40 to 85c VRFEM2060GRIYMxx 6Gbps Industrial 64 60 117 231 408 MLC 40 to 85c VRFEM2120GRITMxx 6Gbps Industrial 128 120 234 441 648 MLC 40 to 85c VRFEM2030GRCWMxx 6Gbps Industrial 32 30 58 626 288 MLC 0 to 70c VRFEM2060GRCYMxx 6Gbps Industrial 64 60 117 231 408 MLC 0 to 70c VRFEM2120GRCTMxx 6Gbps Industrial 128 120 234 441 648 MLC 0 to 70c VRFEM2240GRCVMxx 6Gbps Industrial 256 240 468 862 128 MLC 0 to 70c VRFEM2030GRCWExx 6Gbps Industrial 32 30 58 593 750 eMLC 0 to 70c VRFEM2030GRCYExx 6Gbps Industrial 32 30 58 593 750 eMLC 0 to 70c VRFEM2060GRCYExx 6Gbps Industrial 64 60 117 231 408 eMLC 0 to 70c VRFEM2120GRCTExx 6Gbps Industrial 128 120 234 441 648 eMLC 0 to 70c VRFEM2240GRCVExx 6Gbps Industrial 256 240 468 862 128 eMLC 0 to 70c VRFEM2030GRCWSxx 6Gbps Industrial 32 30 58 626 288 SLC 0 to 70c VRFEM2060GRCYSxx 6Gbps Industrial 64 60 117 231 408 SLC 0 to 70c VRFEM2120GRCTSxx 6Gbps Indu
30. strial 128 120 234 441 648 SLC 0 to 70c VRFEM2030GRIWSxx 6Gbps Industrial 32 30 58 626 288 SLC 40 to 85c VRFEM2060GRIYSxx 6Gbps Industrial 64 60 117 231 408 SLC 40 to 85c VRFEM2120GRITSxx 6Gbps Industrial 128 120 234 441 648 SLC 40 to 85c N i e capacity based on a level of over provisioning applied to wear leveling bad sectors index tables etc 2 Higher capacity points may be available based on customer application Consult your local Viking Field Application Engineer 3 SSD s ship unformatted from the factory unless otherwise requested 4 1 GB 1 000 000 000 Byte 5 One Sector 512 Byte 6 xx is a wild card to indicate customer specific options Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 4 of 43 www vikingtechnology com viking TECHNOLOGY Product Picture s TECHNOLOGY mSATA Top View Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 5 of 43 www vikingtechnology com viking TECHNOLOGY Industrial SSD s Viking s Industrial SSD contains sophisticated provisions to protect firmware and data from corruption due to unexpected power loss However an Industrial SSD by industry definition does not contain on board capacitance Should power fail unexpectedly in flight write data may be lost Industrial SSD s are best used in designs that manage power fail events at the system level Manual 7 24 2014 PSFEM2x
31. ult The contents of the bits 93 F 0000h 12 0 of this word shall change only during the execution of s hardware reset 94 yV 0000h Vendor s recommended and actual acoustic management value 95 F 0000h Stream Minimum Request Size 96 V 0000h Streaming Transfer Time DMA 97 V 0000h Streaming Access Latency DMA and PIO 98 99 F 0000h Streaming Performance Granularity 100 103 y 8GB 256GB Me user LBA for 48 bit Address feature 104 V 0000h Streaming Transfer Time PIO Maximum number of 512 byte blocks per 105 i enon DATA SET MANAGEMENT command 106 F 4000h Physical sector size Logical sector size Inter seek delay for ISO 7779 acoustic testin 10 2 0000h in eee 9 Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 35 of 43 www vikingtechnology com viking TECHNOLOGY F Fixed Word V Variable Default Value Description X Both 108 111 F a Gita Unique ID 112 115 F ocak a Reserved 116 V 0000h Reserved 117 118 F 00000000h Words per logical Sector 119 F 4015h Supported settings 120 F 4015h Command set Feature Enabled Supported 121 126 F Oh Reserved 427 F Oh Removable Media Status Notification feature set support 128 V 0021h Security status 129 159 X Oh Vendor specific Compact Flash Association CFA power 160 F Oh aie PRAP 161 167 X Oh Reserved for assignment by the CFA T
32. ut Info of Executing AFSSI 8580 Command Register 7 6 5 4 3 2 1 0 Features na Sector Count na Sector Number na Cylinder High na Cylinder Low na Device Head obs na obs DEV na na na na Command BSY DRDY DF na DRQ na na ERR Device Head Register DEV shall indicate the selected device Status Register BSY shall be cleared to zero indicating command completion DRDY shall be set to one DF Device Fault shall be cleared to zero DRQ shall be cleared to zero ERR shall be cleared to zero 3 Mechanical Information Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 26 of 43 www vikingtechnology com viking TECHNOLOGY Min 29 70 50 65 Max 4 85 30 00 50 95 Figure 3 1 Dimensions See 83a 2 2 60 holes 2 8 23 8 OND NAN N N o o r PCB T 1 00 0 1 50 80 Uj UTIL A 98 88 max ee 98 88 max 48 05 s 45 00 45 00 45 00 BOTTOM SIDE TOP SIDE 4 20 Min i in Dee LE in 320 fnd 3 20 min Sool E 8 28 A i SAA Detail A c Detail B 25 70 Detail B Scale 2 1 2 0 25 Max 2 0 25 Max Detail A Scale 2 5 1 Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 27 of 43 www vikingtechnology com viking TECHNOLOGY Ug Aa J AAAI TL TT N 2 55 0 05 Pin 52 Pin 2 Detail C Scale 2 1 COMMON DIMENSION TABLE SYMBOL MIN NOM MAX NOTES E2
33. viking TECHNOLOGY SATA 6Gb s Industrial mSATA Manual mSATA mini SATA MO 300 is a non volatile solid state storage device delivering Serial ATA performance reliability and ruggedness for industrial and environmentally challenging applications Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 1 of 43 www vikingtechnology com viking TECHNOLOGY Revision History Date Revision Description Checked By 4 10 13 X1 Preliminary release 5 10 13 A Initial Release 6 26 13 A1 Fix PN s 7 11 13 A2 Add Power Consumption 7 24 13 A3 Seri SMART table Added AES Add product image to 1 page Create separate datasheets for 8 12 13 A4 6Gbps Revise extended SMART attributes Changed Client to Industrial Added SLC PN s Add 3 3V and 5v to block diagram SAANG As voltage table and pin out Revised performance s Revised PN table to avoid confusion on l 9 09 13 A6 temperature and commercial temperature PN s 40 22 13 A7 Revised product image 4 15 14 A8 Revise copyright date and product Bob Desmarais description Revise Pinout pin P45 and P47 to adat AS No Connect Add IOPS data 7 24 14 A10 Add Secure Erase and Military Purge information Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 2 of 43 www vikingtechnology com viking TECHNOLOGY Legal Information Legal Info
34. ww vikingtechnology com viking TECHNOLOGY references for topics and details not addressed here Further it is recommended to consult the list of public S M A R T attributes See the AT Attachment standard for implementation details 5 1 2 SATA 3 0 S M A R T Command Set The supported S M A R T command set is listed in the table below See the AT Attachment standard for implementation details Table 5 4 S M A R T Command Set Value hex Command 00 CF Reserved DO S M A R T read attributes D1 S M A R T read threshold D2 S M A R T enable disable attribute autosave D3 S M A R T save attribute values D4 S M A R T execute off line immediate D5 S M A R T read log sector D6 S M A R T write log sector D7 S M A R T write attribute threshold D8 S M A R T enable operations D9 S M A R T disable operations DA S M A R T return status DB S M A R T enable disable automatic off line DC FF Reserved Vendor Specific Note that D1 D3 and D7 have been made obsolete in the ATA 8 specification 5 1 2 1Extended SMART Attributes Table 5 5 Extended SMART Attribute Table SMART Attribute ID Description Number of accumulated Uncorrectable errors Range 0 Oih 255 Read Error Rate O5h Reallocated Sector Count 09h Power On hours Count Range 0 4294967295 Drive Power Cycle Count Number of accumulated power OCh o
35. xGRxxx Viking Technology Revision A10 Page 24 of 43 www vikingtechnology com viking TECHNOLOGY 2 6 2 7 NSA CSS 9 12 Pattern 1 To fill the whole disk with fixed character pattern of 0x55 Input Info of Executing NSA CSS 9 12 Command Register 7 6 5 4 3 2 1 0 Features 08h Sector Count 2Fh Sector Number na Cylinder High na Cylinder Low na Device Head AOh Command 6Fh Normal Output Info of Executing NSA CSS 9 12 Command Register 7 6 5 4 3 2 il 0 Features na Sector Count na Sector Number na Cylinder High na Cylinder Low na Device Head obs na obs DEV na na na na Command BSY DRDY DF na DRQ na na ERR Device Head Register DEV shall indicate the selected device Status Register BSY shall be cleared to zero indicating command completion DRDY shall be set to one DF Device Fault shall be cleared to zero DRQ shall be cleared to zero ERR shall be cleared to zero Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 25 of 43 www vikingtechnology com viking TECHNOLOGY 2 6 2 8 AFSSI 8580 Pattern 1 To fill the whole disk with fixed character pattern of 0x55 2 To fill the whole disk with fixed character pattern of OxAA 3 To fill the whole disk with random data Input Info of Executing AFSSI 8580 Command Register 7 6 5 4 3 2 1 0 Features 09h Sector Count 2Fh Sector Number na Cylinder High na Cylinder Low na Device Head AOh Command 6Fh Normal Outp
36. xxGRxxx Viking Technology Revision A10 Page 6 of 43 www vikingtechnology com viking Table of Contents 1 INTRODUCTION 10 1 1 Features 10 1 2 Block Diagram 11 1 3 SATA Interface 12 2 PRODUCT SPECIFICATIONS 13 2 1 Performance 13 2 2 Timing 13 2 2 1 STANDBY IMMEDIATE Command 13 2 3 Electrical Characteristics 14 2 3 1 Absolute Maximum Ratings 14 2 3 2 Supply Voltage 14 2 3 3 Supply Current 15 2 3 4 Power Consumption 15 2 4 Environmental Conditions 15 2 4 1 Temperature and Altitude 15 2 4 2 Shock and Vibration 16 2 4 3 Electromagnetic Immunity 16 2 5 Reliability 16 2 6 Data Security 16 2 6 1 Quick Erase 17 2 6 2 Military Secure Erase Sanitization Purge Routines 17 3 MECHANICAL INFORMATION 26 3 1 mSATA SSD Weight 29 4 PIN AND SIGNAL DESCRIPTIONS 29 4 1 Signal and Power Description Tables 29 4 2 Hot Plug Support 30 5 COMMAND SETS 30 Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 7 of 43 www vikingtechnology com viking TECHNOLOGY 5 1 ATA Commands 31 5 1 1 48 Bit Address Command Set 32 5 1 2 ATA General Feature Command Set 32 5 1 3 Device Configuration Overlay Command Set 32 5 1 4 General Purpose Log Command Set 32 5 1 5 Host Protected Area Command Set 33 5 1 6 Power Management Command Set 33 5 1 7 Security Mode Feature Set 33 5 1 8 Identify Device Data 34 5 1 1 S M A R T Support 37 5 1 2 SATA 3 0 S M A R T Command S
37. ylinder Low na Device Head AOh Command 6Fh Normal Output Info of Executing Quick Erase Command Register 7 6 5 4 3 2 1 0 Features na Sector Count na Sector Number na Cylinder High na Cylinder Low na Device Head obs na obs DEV na na na na Command BSY DRDY DF na DRQ na na ERR Device Head Register DEV shall indicate the selected device Status Register BSY shall be cleared to zero indicating command completion DRDY shall be set to one DF Device Fault shall be cleared to zero DRQ shall be cleared to zero ERR shall be cleared to zero 2 6 2 Military Secure Erase Sanitization Purge Routines Many government and military organizations such as NIST NSA define their own standard and procedures for performing a Military Secure Erase which overwrite Manual 7 24 2014 PSFEM2xxxGRxxx Viking Technology Revision A10 Page 17 of 43 www vikingtechnology com viking TECHNOLOGY different patterns to sanitize the flash media Some of the more common military or government purge routines are defined in the following table and the data security features of the drive comply with Department of Defense DoD and US military data security standards Table 2 12 Military Secure Erase Sanitize Routines NSA CSS 9 12 Erase and overwrite all locations with a known unclassified Note 1 pattern Verify the overwrite procedure by randomly rereading the overwritten information to con