1. Lamp Voltage Interface Installation and Oper ation Instr uctions Model No B003 001 SAFETY To ensure safe installation and use of your Lamp Volt Interface LVI please direct all users to read this technical sheet Turn off the power supply at its source before installing this unit or before performing any maintenance work ALLOW TIME FOR CAPACITORS TO DISCHARGE BEFORE WORKING ON ANY POWER SUPPLY DO NOT TOUCH EXPOSED POSITIVE OR NEGATIVE INTERFACE LEADS WHEN INSTALLING THIS DEVICE Keep flammable materials a minimum of three feet from any operating equipment Do not alter the wiring of this unit prior to during or following installation The LVI permits volt reading by a high impedance meter by reducing the actual reading to 1 100 of actual power Therefore an actual voltage of 2000V would be displayed as 20 00 INSTALLATION The Lamp Volt Interface must be installed parallel with the curing system s UV lamp wiring Therefore connector leads are to be installed directly over respective lamp leads connected to ballast and capacitor terminals 1 With electrical power shut off at the source open the power supply cabinet to expose your curing equipment s electrical components Allow enough time for capacitors to discharge all electrical energy before beginning any work 2 Loosen and remove the nut that secures the lamp lead to the ballast terminal Do not remove the lead from th
2. e terminal 3 Slip the round closed end LVI connector lead over the ballast terminal and secure 4 Locate the first capacitor that is wired directly to the first mercury relay Plug the stab on connector onto an available tab on the capacitor 5 Mount the LVI junction box to the inner side wall of the power supply cabinet This unit can be mounted by drilling two holes in the side of the cabinet and securing the junction box with two 6 8 or 10 screws Proper mounting will prevent excessive vibration and ensure consistent long term performance 6 Connect the interface leads into appropriate screw receptacles on a high impedance panel mount volt meter must be a true RMS volt meter available directly from UVPS 7 Close the power supply cabinet when assembly is complete Turn power on at its source idle totally ON Turn your curing system or machinery on 2 With the LVI integrated directly between your curing system s incoming power source and the capacitor the panel mount voltmeter will indicate via its LCD or LED display volt levels at 01 of actual power Therefore for units operating at 2450v the voltmeter will display a reading of 24 50v Lamp Voltage Interface 3 As volt level directly corresponds to lamp performance the meter s readout will provide a ready indicator of how the lamp is working a To set a baseline for lamp performance note in your production log the v
3. olt level after a new lamp achieves peak power following start up This is your baseline figure Installation and Oper ation Instructions Model No B003 001 Since a lamp s energy usage will fluctuate during its life span measure the volt readings against the baseline figure regularly As lamp cooling and degradation will reduce energy consumption and therefore lamp effectiveness the LVI will help guard against under curing by monitoring voltage constantly during the production cycle WARRANTY LIMITED WARRANTY This product is warranted by Con Trol Cure only to purchasers use in business or original equipment manufacture against defects in workmanship or materials under normal use for one year after date of purchase from Con Trol Cure unless otherwise stated in purchase agreement Any part which is determined by Con Trol Cure to be defective in materials or workmanship and returned to Con Trol Cure or authorized service location as Con Trol Cure designates shipping costs prepaid will be as the exclusive remedy repaired or replaced at Con Trol Cure s option DISCLAIMER OF WARRANTY Con Trol Cure has made a diligent effort to illustrate and describe the Lamp Volt Interface in it s product literature however such illustrations and descriptions are for the sole purpose of identification and do not express or imply a warranty that the product is merchantable or fit for a particular purpose or that the product will necessaril
4. y conform to the illustrations or descriptions No warranty or affirmation of fact express or implied other that as set forth in the limited warranty statement above is made or authorized by Con Trol Cure LIMITATION OF LIABILITY Any liability for consequential and incidental damages is expressly disclaimed Con Trol Cure s liability in all events is limited to and shall not exceed the purchase price paid PRODUCT SUITABILITY Many countries states and localities have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary from those in neighboring areas While Con Trol Cure attempts to assure that is products comply with such codes it cannot guarantee compliance and cannot be responsible for how the product is installed or used Before purchase and use of a product please review the product application and national and local codes and regulations and be sure that the product installation and use will comply with them The entire risk arising out of the use or performance of this program and documentation remains with you In no event will Con Trol Cure be liable for any lost profits lost savings incidental or direct damages or other economic consequential damages even if Con Trol Cure or its authorized agents have been advised of the possibility of such damages In addition Con Trol Cure and its suppliers will not be liable for any damages claimed by you based on an
5. y third party claim Copyright 1998 Con Trol Cure All Rights Reserved UV PROCESS SUPPLY INC 1229 W Cortland Street Chicago IL 60614 USA Phone 773 248 0099 Fax 773 880 6647 WwW uvprocess com