Tripp Lite SU12000RT4U User's Manual
Contents
1. LINE BATTERY TRANSFER Transfer time Low voltage transfer to battery power setpoint No transfer time 0 ms in online double conversion mode 65V L1 N L2 N High voltage transfer to battery power setpoint 140V L1 N L2 N SPECIAL FEATURES Cold Start startup in battery mode during a power failure Cold start operation supported High availability UPS Automatic inverter bypass Manual bypass switch Detachable hot swap PDU Hot swappable UPS power module features Hot swappable batteries Green amp high High efficiency economy mode operation Schedulable daily hours of economy mode operation efficiency features CERTIFICATIONS UPS Certifications WARRANTY Product Warranty Period Worldwide Connected Equipment Insurance U S Canada amp Puerto Rico Related Items Optional Products Related Model 2 year limited warranty 250 000 Ultimate Lifetime Insurance Description Tested to UL1778 USA Tested to CSA Canada Tested to NOM Mexico Meets FCC Part 15 Category A EMI SNMPWEBCARD For remote monitoring and control via SNMP Web or Telnet 1 ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires SNUPWEBCARD 1 or switched PDU SRSWITCH Magnetic Door Switch Kit for front and rear doors requires ENVIROSENSE 1 WEXT3 SU12000 WEXT5 SU12000 3 Year Extended Warranty For SU12000 High Low Voltage UPS Models 5 Year Extended Warranty For SU12000 High
2. Tripp Lite 1111 West 35th Street Chicago IL 60609 USA Telephone 773 869 1234 E mail saleshelp tripplite com Model Number SU12000RT4U SmartOnline 12kVA On Line Double Conversion UPS 8U Rack Tower 208 120V or 240 120V Hardwire amp NEMA outputs Split phase input Highlights e 12kVA 12 000VA 8400W on line double conversion UPS e 208 120V or 240 120V 3 output at 60Hz e 8U Rack Tower compatible Hot swappable power and battery modules e USB RS232 amp EPO ports support for SNMP WEB card options e Front panel LEDs with detailed LCD monitoring and control screen e Expandable runtime with optional external battery packs e Hardwire input 4 wire split phase L6 30R C19 amp 5 15 20R outlets Description Tripp Lite 12kVA SmartOnline Hot Swappable Modular Rack Tower UPS offers 12 000 VA on line double conversion UPS support for server network and telecommunications equipment Maintains battery derived AC output during blackouts with active full time power conditioning Fault tolerant auto bypass prevents unexpected service interruptions during overload or internal fault conditions 4U power module and 4U external battery pack installs in 8 rack spaces 8U Upright tower installation supported with optional accessories Maintains full time sine wave output within 3 of selectable 208 120 or 240 120V AC Corrects brownouts and overvoltages from 65V to 140V L N Expandable runtime with optional external battery pack
3. full load levels runtime is further expandable with optional external BP192V18 4U battery packs e Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual e Network interfaces support simultaneous communications via DB9 port USB port and SNMPWEBCARD slot DB9 port supports RS 232 and dry contact messaging HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Included PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected servers plus any number of additional servers over IP e Communications ports support on battery low battery power restored AC voltage DC voltage output current monitoring battery charge current battery capacity AC line frequency timed inverter shutoff activate self test and output power control e Built in Emergency Power Off EPO interface with cable e Includes 13 output receptacles 2 L6 30R 6 C19 5 NEMA 5 15 20R plus hardwire output all of which are available for simultaneous use e Split phase 4 conductor hardwire input connection featured on included detachable PDU e Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS functions and current site electrical conditions e Front panel switches enable power on off control self test and alarm cancel functions e Included
4. Low UPS Voltage UPS Models BP192V18 4U BP192V18 4U External Battery Pack for UPS System 1 2 9USTAND Enables Tower Placement of Rackmount UPS Systems 1 2POSTRMKITHD Enables 2 Post Rackmount Installation of 3U and Larger UPS Transformer and Battery 1 Pack Components PDUMV20 Single Phase Metered PDU 20A 120V OU Vertical Rackmount NEMA 5 15 20R outlets 1 NEMA L5 20P input with 5 20P adapter PDUMV20HV Single Phase Metered PDU 20A 200 240V OU Vertical Rackmount C19 amp C13 outlets 1 C20 inlet with NEMA L6 20P input cable PDUMV30HV Single Phase Metered PDU 30A 208 240V OU Vertical Rackmount C19 amp C13 outlets 1 NEMA L6 30P input plug PDUMNV20 Single Phase Monitored PDU 20A 120V OU Vertical Rackmount NEMA 5 15 20R 1 outlets NEMA L5 20P input with 5 20P adapter PDUMNV20HV Single Phase Monitored PDU 20A 200 240V OU Vertical Rackmount C13 amp C19 1 outlets C20 inlet with NEMA L6 20P input cable PDUMNV30HV Single Phase Monitored PDU 30A 208 240V OU Vertical Rackmount C13 amp C19 1 outlets NEMA L6 30P input plug PDUMV20HVNET Single Phase Switched PDU 20A 200 240V OU Vertical Rackmount C13 amp C19 outlets 1 C20 inlet and NEMA L6 20P cable PDUMV30HVNET Single Phase Switched PDU 30A 208 240V OU Vertical Rackmount C13 amp C19 outlets 1 NEMA L6 30P input plug AS400CABLE KIT Power Management Tools UPS Communication Cable Kit for System i AS400 1 iSeries Servers MODBUSCARD For remote monitoring and con
5. adjustable mounting rails support installation in 4 post 19 inch rack enclosures e Optional 2 9USTAND set of tower stands supports upright tower installation e Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions e 250 000 Ultimate Lifetime Insurance USA Puerto Rico and Canada only Specifications OUTPUT Output Volt Amp 12000 Capacity VA Output kVA capacity 12 kVA Output Watt Capacity 8400 watts Output kW capacity 8 4 Output power factor 0 7 Output Capacity 12 000 VA 240V 10 395 VA 208V 8400 watts 208 240V Details Crest Factor Sul Nominal Output 120V 208V 240V Voltage s Supported Nominal Voltage 240 120V or 208 120V split phase output details Frequency 60 Hz compatibility Output voltage 3 regulation line mode Output voltage 10 regulation Economy line mode Output voltage 3 regulation Battery mode Built in UPS output 5 5 15 20R outlet s 2 L6 30R outlet s 6 C19 outlet s Hardwire receptacles Output circuit breaker Output AC waveform AC mode Output AC waveform battery mode INPUT Rated input current at maximum load Nominal Input Voltage s Supported UPS input connection type UPS input connection description Recommended Electrical Service Phase BATTERY Full load runtime minutes Half load runtime minutes Expandable battery runtime External battery pack compatibi
6. ions see manual Alarm cancel switch Switches 2 Switches control off on power status and alarm cancel self test operation 2 additional switches support set and execute scrolling LCD functions bundled PDU includes bypass switch to enable hot swap UPS power module replacement SURGE NOISE SUPPRESSION UPS AC suppression response time EMI RFI AC noise suppression PHYSICAL Installation form factors supported with included accessories Included mounting accessory description Installation form factors supported with optional accessories Optional mounting accessory notes Primary form factor UPS Power Module dimensions in primary form factor height x width x depth inches UPS Power Module dimensions in primary form factor height x width x depth cm Installed whole system maximum rack depth inches Installed whole system maximum rack depth cm Rack Height Secondary form factor UPS Power Module weight Ibs UPS Power Module weight kg UPS dimensions details Included battery pack dimensions height x width x depth inches Included battery pack dimensions height x width x depth cm Included battery pack weight Ibs Instantaneous Yes 4 post 19 inch rackmount mounting rail kit included 2 sets of adjustable 4 post rack rails included 2 post rackmount 2POSTRMKITWM Tower 2 9USTAND 2 sets of 2POSTRMKITWM required for 2 post rackmount installati
7. lity DC system voltage VDC Battery recharge rate included batteries Battery replacement description VOLTAGE REGULATION Voltage regulation description Overvoltage correction Undervoltage correction 20A branch rated double pole breakers x3 protect 2 C19 and 1 5 15 20R outlets each 30A branch rated double pole breakers x2 protect 1 L6 30R outlet each 20A single pole breakers x2 protect one 5 15 20R outlet each Sine wave Pure Sine wave 50A 208V AC 120V AC 4 wire split single phase 240V AC 120V AC 4 wire split single phase Hardwire 4 wire split phase input L1 L2 N G 50A 208 240 120 Split Phase Single Phase 7 min 8400w 20 min 4200w Supports extended runtime with optional external battery packs BP192V18 4U BP192V557C 16K BP192V787C 16K BP192V1037C 16K BP192V1407C 16K 192 Less than 6 hours from 10 to 80 Hot swappable user replaceable batteries Online double conversion power conditioning 3 output voltage regulation during overvoltages to 140 measured L1 N L2 N 3 output voltage regulation during undervoltages to 65 measured L1 N L2 N LEDS ALARMS amp SWITCHES LED Indicators Alarms Alarm cancel operation 6 LEDs indicate line power online mode economy bypass mode on battery charger and AC output status LCD screen offers additional information and control options Unique audible alarms for all major UPS environmental and power condit
8. on Rackmount 7 x 17 5 x 40 5 17 8 x 44 4 x 102 9 40 5 102 9 8U Tower requires 2 9USTAND 86 39 Includes 4U power module and 4U battery pack 7 x 17 5 x 27 8 17 7 x 44 4 x 70 6 239 Included battery pack weight kg UPS Shipping dimensions height x width x depth inches UPS Shipping dimensions height x width x depth cm Shipping weight Ibs Shipping weight kg Cooling method UPS housing material ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity AC mode BTU hr full load Battery mode BTU hr full load AC mode efficiency rating 100 load AC economy mode efficiency rating 100 load Operating Elevation ft Audible Noise Operating Elevation m COMMUNICATIONS Communications interface Network monitoring port description PowerAlert software Communications cable 108 5 45 5 x 23 5 x 34 3 115 6 x 59 7 x 87 1 448 8 203 8 Fan Steel 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 0 to 95 non condensing 4286 3187 87 94 0 3000m 0 to 10 000 ft 60 dBA at front side 1 meter 0 3000 m USB HID enabled DB9 Serial Contact closure EPO emergency power off Slot for SNMP Web interface RS232 and contact closure communications are supported on one DB9 port Included USB and DB9 cabling included
9. pable Attractive all black color scheme 250 000 connected equipment insurance Package Includes e SU12000RT4UPM 4u UPS Power Module e BP192V18 4U External battery pack e SUPDMB16K Detachable PDU with manual bypass switch e 4 post rackmount installation brackets Features e True online double conversion UPS provides pure full time sine wave AC output free of surges voltage fluctuations and line noise e 12 000 VA 8400 watt output power capacity with dual voltage output of 208 120 or 240 120V e 4U high power density power module and 4U external battery pack supports rackmount installation in 8 rack spaces e Dual conversion UPS actively converts raw input from AC to DC then back to perfect sine wave AC output with enhanced protection from harmonic distortion fast electrical impulses and other hard to solve power problems not addressed by other UPS types e Hardwire input terminals and output receptacles are mounted on a detachable back plate with manual bypass switch to enable hot swappable UPS replacement without powering off connected equipment e Provides perfectly regulated sine wave output power free of line noise transient surges and frequency variation for the most efficient operation of critical servers networking and telecommunications equipment e Maintains output within 3 of selected 208 120 or 240 120V nominal voltage during brownouts and overvoltages e Supports connected equipment during blackouts for 20 7 minutes at half
10. s Converts raw input from AC to DC then resynthesizes output power back to perfect sine wave AC output with enhanced protection from harmonic distortion fast electrical impulses and other hard to solve power problems not addressed by other UPS types Highly efficient operation in optional economy mode setting saving BTU heat output and energy costs Network grade AC surge and noise suppression Network management interfaces include combination DB9 RS 232 enabled and dry contact serial port enhanced USB port and SNMPWEBCARD slot HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Supports simultaneous detailed monitoring of equipment load levels self test data and utility power conditions via all 3 network interfaces Includes PowerAlert monitoring software and complete cabling Supports Emergency Power Off EPO via built in interface Front panel LEDs and LCD readout with scroll controls support visual monitoring of all major UPS functions LED LCD display panel easily rotates for viewing in rackmount or tower configurations Split phase 4 conductor hardwire input and output supported UPS supported outlets include two L6 30R six C19 and 5 low voltage 5 15 20R Output connections are mounted on a detachable backplate with manual bypass switch to enable hot swappable UPS replacement without powering off connected equipment External battery packs are field replaceable and hot swap
11. trol via MODBUS protocol 1 P036 006 6 ft 12AWG Heavy Duty Power cord IEC 320 C19 to IEC 320 C20 1 P041 001 2 1 ft 1OAWG Heavy Duty Power Splitter Cable NEMA L6 30P to 2x NEMA L6 30R 1 More information including related products owner s manuals and additional technical specifications can be found online at http www tripplite com sku SU12000RT4U Copyright 2014 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products