Home

Tripp Lite 6PLUS User's Manual

image

Contents

1. Battery Selection rN NOTE If the Line Fault indicator light illuminates carefully check the AC receptacle the Under Monitor Surge Suppressor is plugged into The receptacle must be tight and securely grounded A loose AC receptacle may cause the Line Fault indicator light to illuminate It must be understood that this Red LED indicates the presence of a wiring fault but does not indicate the exact nature of the fault Therefore a qualified electrician should be contacted to make necessary repairs NOTE If after inspection by a qualified electrician a wiring fault is not detected the Line Fault indicator light may be indicating that the surge suppression components have been compromised as a result of surge damage Even if the surge suppressor is providing AC power at all of the receptacles it may not provide its total rated surge suppression as outlined in the Specifications section Should you require service call Tripp Lite Customer Support at 773 869 1234 Explain fully the perceived problem to the cus tomer support person They will either remedy the problem over the phone or give you instructions about return repair or exchange e LINE OK Green Indicator Light all models except Power Center Indicates 120V AC power is present with no wiring faults detected When this LED is illu minated AC power is safe for connected equipment e LOW VOLTAGE Yellow Indicator Light all models except Powe
2. ENTIAL DAMAGES Some states do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This Warranty gives you specific legal rights and you may have other rights which vary from jurisdiction to jurisdiction TRIPP LITE 1111 W 35th Street Chicago IL 60609 WARNING The individual user should take care to determine prior to use whether this device is suitable adequate or safe for the use intended Since individual applications are subject to great variation the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application Policy of Tripp Lite is one of continuous improvement Specifications are subject to change without notice ULTIMATE LIFETIME INSURANCE POLICY Valid in U S and Canada ONLY VALID FOR ALL MODELS EXCEPT POWER CENTER PC5 TRIPP LITE warrants for the lifetime of the product to repair or replace at TRIPP LITE s option directly connected equipment that is damaged due to power transients while properly connected to TRIPP LITE products offering the ULTIMATE Insurance Policy Reimbursement or restoration for data lost is not included Power transients include spikes and surges on the AC power data or telephone lines that the TRIPP LITE products have been designed to protect against as recognized b
3. Owner s Manual TouchMaster MT 6 TouchMaster PLUS MT 6PLUS Command Console CCI 6 Command Console PLUS CCI6PLUS Command Console Compact CCC4 Power Center PC 5 Under Monitor Surge Suppressors Canadian National Standards c Certified by UL Your Tripp Lite Under Monitor Surge Suppressor protects your sensitive electronic equip ment from spikes surges and line noise on the AC power line It features convenient fin gertip control of AC power for your computer and various peripherals as well as advanced diagnostic indicators that display power protection status PLUS models include a set of RJ style phone jacks for protection against spikes surges and line noise on a single telephone line TouchMaster and Command Console models except Command Console Compact include premium ISOBAR surge suppression POSITIONING YOUR UNDER MONITOR SURGE SUPPRESSOR The Under Monitor Surge Suppressor is designed to be placed between your computer and monitor Place the unit on top of your computer and then place your monitor on top of the Under Monitor Surge Suppressor s housing Each Under Monitor Surge Suppressor is sturdy enough to support the weight of a computer monitor TRIPP LITE THE POWER PEOPLE 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com Copyright 2002 Tripp Lite PowerVerter is a registered trademark of Tripp Lite All rights reserved Intr
4. es do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically TRIPP LITE is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise To receive service under this warranty you must be the original purchaser user of the product in question You must obtain a Returned Material Authorization RMA number from TRIPP LITE Products must be returned to TRIPP LITE with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase
5. nt See Front and Rear Panel illustrations on page 5 for connection to your specific model After you have properly connected your Under Monitor Surge Suppressor to the AC line and telephone line Gif applicable you can connect the AC power cords of your equip ment to the surge suppressor DO NOT OVERLOAD the surge suppressor Connect loads having a total current draw of up to 15 amps Each outlet can handle up to 15 amps but do not exceed a total load of 15 amps for all outlets If the circuit breaker trips remove overload and depress circuit breaker button to reset NOTE The switched outlets are labelled COMPUTER MONITOR PRINTER and AUXILIARY only for your convenience For example it is not necessary to plug a computer into the COMPUTER outlet Any type of equipment as long as it does not exceed 15 amps can be plugged into any of the outlets TouchMaster TouchMaster PLUS Command Console Command Console PLUS Power Center Switched Outlets The five switched outlets on the rear of the unit can be controlled individually by their respective ON OFF switches located on the front of the unit Also all five outlets may be controlled simultaneously by the ON OFF switch labelled MASTER NOTE the outlet labelled COMPUTER on the rear of the TouchMaster and Command Console models can only be controlled by the MASTER switch The indicator lights or the switches themselves depending on the model will illuminate when the switches are
6. oduction CONNECTING YOUR UNDER MONITOR SURGE SUPPRESSOR Connection to AC Power Line all models The Under Monitor Surge Suppressor power cord should only be connected to a standard 3 wire grounded 120 Volt AC 60 Hz outlet A CAUTION A DO NOT connect to an ungrounded AC outlet DO NOT connect to 2 wire extension cords or adapters Lack of a proper ground connection will eliminate common mode protection and cause small leakage potential on the case However you can plug 2 wire devices into any of the surge suppressor s outlets Connection To Telephone Line PLUS models only Under Monitor PLUS models have two female RJ style phone jacks that accept connection of a wide range of equipment with male RJ style plugs PLUS models provide 2 wire single telephone line protection PLUS models MUST always be the FIRST item connected in line from the telephone jack PLUS models MUST always be plugged into a 3 wire grounded outlet for the telephone protection to work Connect the phone cord from the wall jack directly to the PLUS jack labelled IN or LINE Connect the phone cord from the device to be protected directly to the PLUS jack labelled OUT or EQUIP The connected equipment is now protected against spikes surges and line noise on the telephone line Introduction continued Ax CAUTION A DO NOT drill into any part of the housing DO NOT open as there are no user serviceable parts inside Connecting Your Equipme
7. on Present LED does not illuminate then some of the surge suppression components are not functioning and the unit should be returned for repair You may still use the unit However connected equipment will be protected from spikes and surges at a lesser level than normal e LINE FAULT Red Indicator Light all models except Power Center Indicates a wiring fault has been detected If this LED illuminates at anytime the unit is plugged in the fault should be repaired by a qualified electrician as soon as possible This LED indicates that phases are reversed ground is missing or some other sort of wiring error exists in the circuit the Under Monitor Surge Suppressor is plugged into The Line Fault detector circuitry will identify most common wiring faults but will not necessarily detect every possible type of fault Front Panels 1 6 5 4 3 2 FRONT PANEL FEATURES Switches l 1 Individual oo c 2 Master Indicator Lights ae 3 Protection Present 4 Line Fault 5 Line OK 6 Low Voltage TouchMaster TouchMaster PLUS 1 3 Fa PAN J NS was NX STS ea 2 DE Ladal Command Console Command Console PLUS CEN EY en _ Command Console Compact
8. p to prevent any possible damage When the circuit breaker trips the plunger will be extended Remove the overload and allow the breaker to cool for one minute before depressing the plunger to reset Static Discharge all models except Command Console Compact It is recommended that you touch your Under Monitor Surge Suppressor before starting work at your computer This will safely dissipate static that can damage sensitive electronic cir cuitry Follow the simple procedure outlined below for your model CTouchMaster TouchMaster PLUS touch the shiny metal plate on the right side of the front panel ower Center Command Console Command Console PLUS touch any metal part of the cabinet Diagnostic Indicator Lights There are up to four LEDs on the front panel that indicate various operating parameters when the unit is plugged into a live 120V AC 60 Hz outlet e PROTECTION PRESENT Green Indicator Light all models Indicates the surge suppression components are intact and providing full protection against spikes and surges This LED should be illuminated anytime the MASTER switch is turned ON and power is present as indicated by one of the following TouchMaster TouchMaster PLUS Green Indicator Light above the MASTER switch is illuminated Command Console Command Console PLUS Power Center MASTER switch is illuminated Command Console Compact Red Indicator Light below MASTER switch is illuminated If the Protecti
9. pushed ON and power is reaching the respectively labelled out lets on the rear of the unit The MASTER switch must be pushed ON for the other indi vidual switches to work Before turning the switches ON confirm that incoming AC power is safe for connected equipment according to the diagnostic indicators Both green indicator lights PRO TECTED and Line OK should be illuminated Unswitched Outlets not available on Power Center There is one surge protected unswitched outlet on the rear of the unit This outlet is con stantly powered regardless of the position of any of the other switches including the MASTER switch as long as the unit is plugged into a live 120V AC outlet The outlet is designed to provide power for a clock lamp etc Command Console Compact The four outlets on the rear of the Command Console Compact can be controlled by the two switches on the front panel labelled MASTER and AUXILIARY Power to ALL of the out lets can be turned ON and OFF using the MASTER switch Power to the outlets labelled AUXILIARY 1 and AUXILIARY 2 can be turned ON and OFF using the AUXILIARY switch The red indicator lights beneath the switches on the front panel will illuminate when the switches are ON and power is reaching the outlets on the rear of the unit Circuit Breaker ali models If the current draw of the equipment connected to the surge suppressor exceeds 15 amps for longer than a few seconds the circuit breaker will open tri
10. r Center and Command Console Compact Indicates that incoming line voltage has fallen below acceptable levels If this LED illuminates while you are using your Under Monitor Surge Suppressor you should turn off your equipment to prevent possible low voltage brownout damage When the line voltage reaches a safe level once again this light will turn OFE indicating brownout danger is over Specifications No of AC Line Cord No of Control AC Energy Surge Transient Ultimate AC Receptacles Length Switches Absorption Suppression Response Dimensions Lifetime Model NEMA 5 15R ft Master Aux joules amp spikes Time HxWxD in Insurance TOUCHMASTER 6 10 1 4 1280 96 000 Ons 15 8 x 131 4 x 121 2 25 000 MT 6 TOUCHMASTER PLUS 6 10 1 4 1790 132 000 Ons 15 8 x 131 4 x 121 2 25 000 MT 6 PLUS COMMAND CONSOLE 6 9 1 4 1110 84 000 Ons 2x 131 2 x 121 2 15 000 CCI 6 COMMAND CONSOLE PLUS 6 9 1 4 1450 108 000 Ons 2x 131 2 x 121 2 15 000 CCI 6 PLUS COMMAND CONSOLE COMPACT 4 8 14 900 72 000 Ons 2x 101 2 x 141 2 5 000 CCC 4 POWER CENTER PC 5 5 6 1 5 65 6 500 lt 1 ns 21 8 x 121 8 x 13 PC 5 ALL MODELS Rated Input Voltage 120V AC 50 or 60 Hz Rated Current and Load Handling 15 amps maximum 1800 watts 15 amps maximum per receptacle Circuit Breaker 15 amp resettable Exceeds IEEE 587 category A amp B specifications All line cords are 3 conductor grounded High voltage spike protection works between hot
11. rotection device is not provided including but not limited to lack of a proper safety ground Telephone service equipment must also include a properly installed and operating primary protection device at the telephone service entrance such devices are normally added during telephone line installation All above warranties are null and void if the TRIPP LITE product has been improperly installed tampered with or altered in any way or if the connected equipment was not used under normal operating conditions or in accordance with any labels or instructions All claims under this warranty must be submitted in writing to Tripp Lite within 30 days of the occurrence or the claim will not be considered This warranty does not include damage resulting from accident or misuse and applies to the domestic USA amp Canada use of these products only Tripp Lite reserves the right to determine whether the damage to the connected equipment is due to malfunction of the Tripp Lite product by requesting the equipment in question be sent to Tripp Lite for examination This policy is above and beyond only to the extent needed of that provided by any coverage of connected equipment provided by other sources including but not limited to any manufacturer s warranty and or any extended warranties EXCEPT AS PROVIDED ABOVE TRIPP LITE MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some stat
12. to neutral hot to ground and neutral to ground except PC5 hot to neutral TELEPHONE LINE SPECIFICATIONS PLUS MODELS ONLY Clamping Voltage 260V peak 10 Response Time lt 1 picosecond Peak Transient Input Voltage 6 Kv 10 microseconds Input Output Connectors two female RJ style modular jacks phone cable included 2 wire single line protection LIFETIME LIMITED WARRANTY VALID FOR ALL MODELS EXCEPT POWER CENTER PC5 WHICH HAS A 5 YEAR WARRANTY Seller warrants this product if used in accordance with all applicable instructions to be free from original defects in material and workmanship for its lifetime If the product should prove defective in material or workmanship within that period Seller will repair or replace the product in its sole discretion Service under this Warranty can only be obtained by your delivering or shipping the product with all shipping or delivery charges prepaid to Tripp Lite 1111 W 35th Street Chicago IL 60609 Seller will pay return shipping charges THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ALL IMPLIED WARRANTIES INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQU
13. y industry standards AC POWER LINE TRANSIENTS To claim damages the TRIPP LITE product must be plugged into a properly wired and grounded outlet No extension cords or other electrical connections may be used The installation must comply with all applicable electrical and safety codes set forth by the National Electrical Code NEC Except as provided above this warranty does not cover any damage to properly connected electronic equipment resulting from a cause other than an AC power transient If user meets all of the above requirements TRIPP LITE will repair or replace at TRIPP LITE S option equipment up to the specified value See ULTIMATE Insurance Policy Limits No coverage is allowed for damage entering from telephone or data lines unless they are separately protected as described below TELEPHONE AND DATA LINE TRANSIENTS Tripp Lite will repair or replace directly connected equipment that is damaged by transients on telephone and or data lines only when all such paths are protected by a Tripp Lite protection product s and the AC power utility line is simultaneously protected by a Tripp Lite power protection device UPS surge suppressor or line conditioner with ULTIMATE Insurance coverage This product protects one line therefore one directly connected piece of equipment Reimbursement dollar limits will be equal to that of the Tripp Lite power protection protector Coverage is excluded where a suitable environment for the p

Download Pdf Manuals

image

Related Search

Related Contents

Guide d`implantation  Frigidaire FFSS2314QE Product Specifications Sheet  GP370 Series - Pro-face America HMI Store  Anschlüsse am Gerät  WatchGuard XTM 25 -> XTM 26  Fujitsu LIFEBOOK AH552/SL  Règlement de consultation  Actualités - CClin Sud-Est  L` Art de vivre Outdoor Catalogue 2014 - 2015  Télécharger la fiche  

Copyright © All rights reserved.
Failed to retrieve file