Home
Tripp Lite SU6000RT3UHV User's Manual
Contents
1. Tripp Lite 1111 West 35th Street Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 E mail saleshelp tripplite com Model SU6000RT3UHV SmartOnline Expandable Rack Tower UPS System Online double conversion protection for mission critical applications Highlights e 6000VA online 6U rack tower UPS 3U Power Module 3U Battery Pack e Zero transfer time on line double conversion and economy mode operation supported e Enhanced serial communications ports SNMP Web card slot and EPO jack e Maintains 200 208 220 230 or 240V output 2 during brownouts to 156 and overvoltages to 276V e Fault tolerant manual and auto bypass modes e Expandable runtime with optional external battery packs e 250 000 Ultimate Lifetime Insurance USA Puerto Rico amp Canada only Description Tripp Lite 6kVA Smart Online RM UPS 6000VA The Smart Online SUBODORT3UHV double conversion UPS protects server networking or telecommunications equipment from blackouts voltage fluctuations and surges in a compact tower rackmount housing In a rack configuration the power module and battery pack occupy only 3 rack spaces each 6U total Upright tower placement of entire system supported with included tower stands Large capacity 6 000VA 4200 watt power module double conversion technology converts raw input AC to DC then resynthesizes it back to perfect sine wave AC output within 2 of user selectable 200 208 220 230 240V AC
2. e with separate purchase 2POSTRMKITWM 2 required e Includes RJ11 EPO emergency power off port and interconnection cable e 250 000 Ultimate Lifetime connected equipment insurance USA Puerto Rico amp Canada Only e 2 year manufacturers product warranty Specifications SYSTEM OVERVIEW Voltage 208V AC 200 208 220 230 240V compatibility Frequency 50 60Hz compatibility OUTPUT Output VA 6000 Output watts 4200 Output nominal 208V AC 200 208 220 230 240V voltage Output voltage Maintains pure sine wave output at all times regulated within 2 of selected nominal output voltage less than 5 total regulation harmonic distortion Output frequency Regulates line frequency to 50 60Hz 0 05Hz regulation Outlet quantity Hardwire type Overload protection Resettable 40A circuit breaker INPUT Maximum input 30A 4700 watts max amps Input connection Hardwire type Recommended 30A 208V Electrical Service BATTERY Full load runtime Included batteries 8 min 6000VA Half load runtime Included batteries 20 min 3000VA Expandable battery runtime DC system voltage Typical battery lifespan Supports extended runtime with optional external battery packs 240 VDC 3 6 years depending on usage Battery recharge rate Less than 8 hours to 90 included battery set only VOLTAGE REGULATION Voltage regulation description Overvoltage On line double conversion process give this UPS
3. for use with select Tripp Lite UPS Systems External battery pack for use with select Tripp Lite UPS Systems External battery pack for use with select Tripp Lite UPS Systems External battery pack for use with select Tripp Lite UPS Systems SU30ACORD Optional Input Cord for UPS System Universal 2 Post Rackmount Kit Supports 2U to 4U UPS systems and battery packs 3 year 5 year next day and on site warranty coverage available for select opportunities contact Tripp Lite Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional AS400CABLE KIT SNMP Accessories Power Management Tools UPS Communication Cable Kit for System i AS400 iSeries Servers Qty optional ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires SNMPWEBCARD or Qty optional switched PDU SNMPWEBCARD For remote monitoring and control via SNMP Web or telnet Qty optional Start Up Warranty Services W02 BW0O Regular business hours start up excludes on site warranty Qty optional W02 BW2 1BD Regular business hours start up and two year on site next business day break fix Qty optional warranty service for locations within 350 miles of a covered service area W02 BW2 247 Regular business hours start up and two year on site 24 by 7 break fix warranty service Qty optional for locations within 250 m
4. iles of a covered service area W02 BW3 1BD Regular business hours start up and three year on site next business day break fix Qty optional warranty service for locations within 350 miles of service area W02 BW3 247 Regular business hours start up and three year on site 24 by 7 break fix warranty service Qty optional for locations within 250 miles of service area W02 EWO Evening or weekend hours start up excludes on site warranty Qty optional W02 EW2 1BD Evening or weekend hours start up and two year on site next business day break fix Qty optional warranty service for locations within 350 miles of service area W02 EW2 247 Evening or weekend hours start up and two year on site 24 by 7 break fix warranty Qty optional service for locations within 250 miles of service area W02 EW3 1BD Evening or weekend hours start up and three year on site next business day break fix Qty optional warranty service for locations within 350 miles of service area W02 EW3 247 Evening or weekend hours start up and three year on site 24 by 7 break fix warranty Qty optional service for locations within 250 miles of service area W02 BW1 1BD Regular business hours start up and one year on site next business day break fix Qty optional warranty service for locations within 350 miles of a covered service area W02 BW 1 247 Regular business hours start up and one year on site 24 by 7 break fix warranty service Qty optional for locations w
5. ithin 250 miles of a covered service area W02 EW1 1BD Evening or weekend hours start up and one year on site next business day break fix Qty optional warranty service for locations within 350 miles of service area W02 EW1 247 Evening or weekend hours start up and one year on site 24 by 7 break fix warranty Qty optional service for locations within 250 miles of service area More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModellD 1972 2009 Tripp Lite All Rights Reserved
6. on manual Features e True on line double conversion UPS provides pure sine wave AC output at all times e World wide compatibility with Euro 50Hz and High Voltage North American 60Hz power e Maintains continuous operation through blackouts voltage fluctuations and surges with zero transfer time e Removes harmonic distortion electrical impulses frequency variations and other hard to solve power problems e 6000VA 4200 watt power capacity with hardwire input output connections e Accepts input voltages between 156 and 276 regulating output within 2 of selectable 200 208 220 230 240v AC output e Standard included 3U battery pack provides 20 minutes runtime at half load 3000VA and 8 minutes at full load 6000VA e Expandable runtime with multiple external battery packs e Innovative design makes unit adaptable for rackmount tower or stacking applications e Power module and battery pack require only 3 rack spaces each 6U total rack space usage e DB9 serial port for network interface SNMP compatible e Slot for optional SNMP web card part SNMPWEBCARD e PowerAlert unattended shutdown software and 6 ft network cable included e Fault tolerant auto bypass maintians continuous utility output to connected equipment even in cases where the UPS is overloaded or suffers an internal failure that requires service e Diagnostic LEDs e Mounting hardware included with each 3U module for 4 post rackmount installation 2 post telecom rack compatibl
7. ontinuous operation during overvoltages to 276VAC Above this point output is maintained utilizing battery transfer to battery reserves power SPECIAL FEATURES EPO port Includes dedicated EPO emergency power off interface and cabling Cold Start Yes inverter can be cold started to enable temporary AC output during a power failure Appearance Attractive black steel rackmount housing BATTERY PACK ACCESSORY optional Battery Pack BP240V10RT3U BP240V557C 1PH BP240V787C 1PH BP240V1037C 1PH BP240V1407C 1PH Accessory optional CERTIFICATIONS Certifications Tested to UL1778 USA cUL Canada CE Europe Class A emissions NOM Mexico GOST IRAM SASO WARRANTY Product Warranty 2 year product warranty Period Connected 250 000 connected equipment insurance USA Puerto Rico and Canada only Equipment Coverage Optional Coverage Related Items Backplates SUPDM11 Extended Warranties WEXT3 SU6000HV WEXT5 SU6000HV External Battery Packs BP240V10RT3U BP240V557C 1PH BP240V787C 1PH BP240V1407C 1PH BP240V1037C 1PH Power Cables SU30ACORD Rackmount Wallmount Kits 2POSTRMkKITWM Shutdown Cable Kits Corded UPS Backplate Outlet Kit Adds AC plug in connection and AC output receptacle to SU6000RT3UHV UPS 3 Year Extended Warranty For SU6000RT3UHV only 5 Year Extended Warranty For SU6000RT3UHV only External Battery Pack and Cable 3U Expandable Black 3 Point Connector External battery pack
8. output voltages Frequency regulation locks output power to 50 60Hz 0 2 Hz removing harmonic distortion fast electrical impulses and other hard to solve power problems not addressed by other UPS types Perfectly regulated continuous sine wave output with zero transfer time offers guaranteed uptime and compatibility with all equipment types Highly efficient operation in optional economy mode setting saving BTU heat output and energy costs Hardwire input and output connections support a variety of permanent or PDU style power connections Battery support can be extended through the addition of external battery packs Includes slot for internal SNMP WEB card plus DB9 contact closure and DB9 enhanced serial monitoring ports for unattended shutdown remote control and monitoring of UPS system and power data Applications e Ideal for protection of critical 200 208 220 230 240v equipment in server rooms internetworking closets and telecommunications systems in rackmount or tower applications Common applications include corporate or departmental servers workstations hubs routers bridges CAD CAM workstations concentrators IP telephony and traditional PBX switching systems Package Includes e SUGOOORT3UHV system includes 1 3U power module and 1 3U battery pack e PowerAlert UPS management software and complete cabling e Mounting hardware to support each 3U module in 4 post rack enclosures tower stands e Warranty information e Instructi
9. the ability to maintain output voltage within 2 of selected nominal voltage at all times Maintains continuous operation without using battery power during overvoltages to 276VAC regulating output within 2 correction of selected nominal Brownout Maintains continuous operation without using battery power during brownout undervoltage conditions to 156VAC correction regulating output within 2 of selected nominal LEDS ALARMS amp SWITCHES Front panel LEDs 6 LED DISPLAY line power bypass inverter charger output AC and battery operation SELECTABLE LCD DISPLAY input output voltage Hz battery voltage and charge level and detailed warnings regarding all major UPS functions LED LCD display panel easily rotates for viewing in rackmount or tower configurations Alarms Multi function audible alarm offers notification of UPS start backup operation low battery overload UPS fault inverter fault DC bus fault overtemperature remote shutdown shutdown imminent and shutdown complete Switches Includes main power off on switch plus 2 switches to set and execute scrollable LCD functions SURGE NOISE SUPPRESSION AC suppression Instantaneous response time EMI RFI AC noise Yes suppression PHYSICAL Shipping weight 323 Ibs Shipping weight 145 4 kg Unit weight Ibs Unit weight kg Unit Dimensions HWD in Unit Dimensions HWD cm Material of construction Form factors supported Cooling method Batter
10. y Access ENVIRONMENTAL Relative Humidity Storage Temperature Operating Temperature Line mode BTU hr Max COMMUNICATIONS Network monitoring port Software and cabling included SNMP compatibility Power Module 43 8 Ibs Battery Pack 139 Ibs Power Module 19 7 kg Battery Pack 61kg Power Module 5 25 x 17 5 x 26 Battery Pack 5 25 x 17 5 x 25 Power Module 13 3 x 44 5 x 66 Battery Pack 13 3 x 44 5 x 63 5 Steel Rack 6U Built in cooling fan User replaceable hot swappable external battery pack 0 to 95 non condensing 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 1418 Includes 2 built in DB9 monitoring ports 1 RS232 1 contact closure Includes PowerAlert UPS monitoring software for all common network and standalone operating systems Cabling included Built in accessory slot accommodates internal SNMP Web card and other network accessories LINE BATTERY TRANSFER Transfer time from ZERO online UPS continuously converts incoming AC to DC then back to AC When line power is interrupted UPS line power to maintains continuous output from battery reserves with absolutely no disruption in output AC power battery mode Low voltage Maintains continuous operation during undervoltages as low as 156VAC Below this point output is maintained utilizing transfer to battery battery reserves power High voltage Maintains c
Download Pdf Manuals
Related Search
Related Contents
Straight Knee Wrap Manual CR Comité Directeur du 30.05.08 ADSR Upgrade Builder`s Guide bizhub 501 / bizhub 421 / bizhub 361 / ineo 501 Window Air Conditioner SVC MANUAL(Exploded Mode d'emploi Propex II Sony XDR-S16DBP Service manual as a PDF-file here Massive Wall light 56280/48/10 Copyright © All rights reserved.